Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Physically interpretable approximations of many-body spectral functions

The rational function approximation provides a natural and interpretable representation of response functions such as the many-body spectral functions. We apply the vector fitting (VFIT) algorithm to fit a variety of spectral functions calculated from the Holstein model of electron-phonon interactions. We show that the resulting rational functions are highly efficient in their fitting of sharp features in the spectral functions, and could provide a means to infer physically relevant information from a spectral data set. The position of the peaks in the approximated spectral function are determined by the location of poles in the complex plane. Additionally, we developed a variant of VFIT that incorporates regularization to improve the quality of fits. With this procedure, we demonstrate it is possible to achieve accurate spectral function fits that vary smoothly as a function of physical conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Gas Sensors for Enhanced Reliability of SOFC Operation

GE Research, in partnership with SUNY Polytechnic Institute (SUNY Poly), designed, built, and tested gas sensors for in situ monitoring of H 2 and CO anode tail gases produced with on-site steam reforming in solid oxide fuel cell (SOFC) systems. The knowledge of the H 2 /CO ratio of these anode tail gases should allow accurate determination and control of the efficiency of the reforming process in the SOFC system and should deliver a lower operating cost for SOFC customers. The project objectives were to achieve multi-gas monitoring capability with a single multivariable sensor, and to sustain this performance in the presence of gaseous interferences and a potential poison for the sensor. The duration of the project was 24 months with the project structure that included three technical tasks such as (1) development of design rules of photonic nanostructures for H 2 and CO gas detection, (2) laboratory validation of photonic nanostructures for selective H 2 and CO gas detection, and (3) validation of photonic nanostructures for initial stability and poison-resistance against H 2 S. To build multivariable sensors for selective H 2 and CO gas detection in the presence of interferences, we expanded our earlier knowledge of multi-gas sensors into new fabrication and functionalization methodologies as well as into new methodologies for the spectral data analysis of multi-gas responses. We have advanced our design rules of the three-dimensional (3D) photonic nanostructures that allowed detection of H 2 and CO at high temperatures as individual gases and as their mixtures and rejection of interferences such as CO 2 , H 2 O, CH 4 , and other hydrocarbons for SOFC applications. Our advanced design rules should be attractive for building the new generation of cost-effective industrial sensors. Stability and poison resistance of our 3D photonic nanostructures was tested in the laboratory conditions. While initially we utilized conventional machine learning data analysis tools, we have found that they were unable to correct for the sensor drift. Thus, we have implemented new methods of machine learning for the analysis of our spectral data. These learnings pave the way to move the future studies into advanced testing of effects of interferences, aging and field tests. In future, our work will continue to advance our sensing designs to operate in conditions with known and unknown interferences by implementing nanostructures with enhanced spectral diversity of responses to gaseous species of interest and interferences. Our systematic reduction of technical risks in this completed project and in future studies will ensure transition of this sensing technology to commercialization.

03 NATURAL GAS↗

Spectral-based analysis of thin film luminescent solar concentrators

We present a method to evaluate the parameters defining the efficiency of luminescent solar concentrators (LSCs). The light harvesting and self-absorption properties of thin film LSCs on glass substrates are determined by optical spectroscopy and the resulting optical efficiency is consistent with the directly measured photon flux gain. (author)

14 SOLAR ENERGY↗

Machine Learning for Challenging EELS and EDS Spectral Decomposition

Scanning transmission electron microscopy (STEM) is one of the primary methods of characterizing heterogenous catalysts due to its unprecedented spatial resolution and the ability to perform imaging and chemical analysis simultaneously at the atomic scale. Here the characterization of heterogenous catalysts that are composed of metal and oxide support, the atomic configurations are often probed by Z-contrast imaging while the chemical distributions can be revealed by using either electron energy loss spectroscopy (EELS) or energy dispersive X-ray spectroscopy (EDS).

47 OTHER INSTRUMENTATION↗

Investigation of the spatiotemporal characteristics of the electric field in the Ne-H{sub 2} plasma of a beam-type high-voltage pulsed discharge

In the present work, the spatiotemporal dynamics of the electric field E(x, t) of plasma produced by a beam-type high-voltage pulsed discharge is investigated. The electric field strength E(x, t) in an accelerating gap and in a plasma flare was determined from the measured Stark splitting of the H{sub β} hydrogen line. The obtained dependence E(x, t) was used to calculate the electron distribution function and the spectral line intensities in the accelerating gap and in the plasma flare by the method of statistical modeling. The calculated population of He atomic states excited by electron impact and their comparison with the measured spectral line intensities I(λ, x, t) demonstrate that a reverse electric field retarding the electron motion and leading to electron beam degradation must be present in the plasma flare near the grid. Measurement of the field strength from the Stark splitting of the H{sub β} line demonstrates that it can reach considerable values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonrelativistic structure calculations of two-electron ions in a strongly coupled plasma environment

In this work, the controversy between the interpretations of recent measurements on dense aluminum plasma created with the Linac coherent light source (LCLS) x-ray free electron laser (FEL) and the Orion laser has been addressed. In both kinds of experiments, heliumlike and hydrogenlike spectral lines are used for plasma diagnostics. However, there exist no precise theoretical calculations for He-like ions within a dense plasma environment. The strong need for an accurate theoretical estimate for spectral properties of He-like ions in a strongly coupled plasma environment leads us to perform ab initio calculations in the framework of the Rayleigh-Ritz variation principle in Hylleraas coordinates where an ion-sphere potential is used. An approach to resolve the long-drawn problem of numerical instability for evaluating two-electron integrals with an extended basis inside a finite domain is presented here. The present values of electron densities corresponding to the disappearance of different spectral lines obtained within the framework of an ion-sphere potential show excellent agreement with Orion laser experiments in Al plasma and with recent theories. Moreover, this method is extended to predict the critical plasma densities at which the spectral lines of H-like and He-like carbon and argon ions disappear. Incidental degeneracy and level-crossing phenomena are being reported for two-electron ions embedded in strongly coupled plasma. Thermodynamic pressure experienced by the ions in their respective ground states inside the ion spheres is also reported.

Bhattacharyya, S.↗

Machine learning reveals cyclic changes in seismic source spectra in Geysers geothermal field

The earthquake rupture process comprises complex interactions of stress, fracture, and frictional properties. New machine learning methods demonstrate great potential to reveal patterns in time-dependent spectral properties of seismic signals and enable identification of changes in faulting processes. Clustering of 46,000 earthquakes of 0.3 < ML < 1.5 from the Geysers geothermal field (CA) yields groupings that have no reservoir-scale spatial patterns but clear temporal patterns. Events with similar spectral properties repeat on annual cycles within each cluster and track changes in the water injection rates into the Geysers reservoir, indicating that changes in acoustic properties and faulting processes accompany changes in thermomechanical state. The methods open new means to identify and characterize subtle changes in seismic source properties, with applications to tectonic and geothermal seismicity.

15 GEOTHERMAL ENERGY↗

Estimation of the potential efficiency of a multijunction solar cell at a limit balance of photogenerated currents

A method is proposed for estimating the potential efficiency which can be achieved in an initially unbalanced multijunction solar cell by the mutual convergence of photogenerated currents: to extract this current from a relatively narrow band-gap cell and to add it to a relatively wide-gap cell. It is already known that the properties facilitating relative convergence are inherent to such objects as bound excitons, quantum dots, donor-acceptor pairs, and others located in relatively wide-gap cells. In fact, the proposed method is reduced to the problem of obtaining such a required light current-voltage (I–V) characteristic which corresponds to the equality of all photogenerated short-circuit currents. Two methods for obtaining the required light I–V characteristic are used. The first one is selection of the spectral composition of the radiation incident on the multijunction solar cell from an illuminator. The second method is a double shift of the dark I–V characteristic: a current shift J{sub g} (common set photogenerated current) and a voltage shift (−J{sub g}R{sub s}), where R{sub s} is the series resistance. For the light and dark I–V characteristics, a general analytical expression is derived, which considers the effect of so-called luminescence coupling in multijunction solar cells. The experimental I–V characteristics are compared with the calculated ones for a three-junction InGaP/GaAs/Ge solar cell with R{sub s} = 0.019 Ω cm{sup 2} and a maximum factual efficiency of 36.9%. Its maximum potential efficiency is estimated as 41.2%.

36 MATERIALS SCIENCE↗

Scalable waveplate for ultraviolet applications using laser-imprinted birefringence in silica

A method for fabrication of large-aperture waveplate suitable for operation in the near-ultraviolet spectral region is demonstrated. The waveplate was fabricated using femtosecond direct laser writing of bulk fused silica. This method enables the precise control of the induced birefringence, which is introduced via the generation of nanopores with geometrical features that are controlled by the laser processing parameters. The resulting structures also introduce a small loss of transmission that is on the order of 4% at 351 nm. The laser-induced–damage threshold in the nanosecond regime was found to approach that of the native fused-silica substrate, which makes it a suitable candidate for polarization control in laser fusion research applications.

Shevtsov, S. I. [Univ. of Southampton (United King↗

Efficient calculation of 1-D periodic Green's functions for leaky-wave applications.

In this paper an approach is described for the efficient computation of the mixed-potential scalar and dyadic Green's functions for a one-dimensional periodic (periodic along x direction) array of point sources embedded in a planar stratified structure. Suitable asymptotic extractions are performed on the slowly converging spectral series. The extracted terms are summed back through the Ewald method, modified and optimized to efficiently deal with all the different terms. The accelerated Green's functions allow for complex wavenumbers, and are thus suitable for application to leaky-wave antennas analysis. Suitable choices of the spectral integration paths are made in order to account for leakage effects and the proper/improper nature of the various space harmonics that form the 1-D periodic Green's function.

99 GENERAL AND MISCELLANEOUS↗

Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

Laser Ablation↗

Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions

A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5–3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion in the spectral response with decreasing detector element size. If not corrected for, this caused a large bias in estimating tissue density parameters for material decomposition. It was also observed that degradation of the spectral response due to characteristic x-rays caused worsening precision in the estimation of tissue density parameters. It was observed that characteristic x-rays do cause some degradation in the spatial and spectral resolution of thin CZT detectors operating under breast CT conditions. These degradations should be manageable with careful selection of the detector element size. Even with the observed spectral distortion from characteristic x-rays, it is still possible to correctly estimate tissue parameters for material decomposition using spectral CT if accurate modeling is used.

36 MATERIALS SCIENCE↗

A fluorescence-based method for rapid and direct determination of polybrominated diphenyl ethers in water

A new method was developed for rapid and direct measurement of polybrominated diphenyl ethers (PBDEs) in aqueous samples using fluorescence spectroscopy. The fluorescence spectra of tri- to deca-BDE (BDE 28, 47, 99, 153, 190, and 209) commonly found in environment were measured at variable emission and excitation wavelengths. The results revealed that the PBDEs have distinct fluorescence spectral profiles and peak positions that can be exploited to identify these species and determine their concentrations in aqueous solutions. The detection limits as determined in deionized water spiked with PBDEs are 1.71-5.82 ng/L for BDE 28, BDE 47, BDE 190, and BDE 209 and 45.55–69.95 ng/L for BDE 99 and BDE 153. The effects of environmental variables including pH, humic substance, and groundwater chemical composition on PBDEs measurements were also investigated. These environmental variables affected fluorescence intensity, but their effect can be corrected through linear additivity and separation of spectral signal contribution. Compared with conventional GC-based analytical methods, the fluorescence spectroscopy method is more efficient as it only uses a small amount of samples (2-4 mL), avoids lengthy complicated concentration and extraction steps, and has a low detection limit of a few ng/L.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Open Cluster IC 1369 and Its Vicinity: Multicolor Photometry and Gaia DR2 Astrometry

The open cluster IC 1369, located in Cygnus close to the galactic equator at the 89.°6 longitude, and its vicinity are investigated by applying two-dimensional photometric classification of stars down to V = 19 mag measured in the Vilnius seven-color photometric system. Employing the Gaia DR2 coordinates, parallaxes, and proper motions, 143 cluster members are found having cluster membership probabilities ≥0.75. The hottest stars of the evolved main sequence are of spectral class B9. Distances to the cluster, determined by two methods based on the Gaia parallaxes, are 3280 and 3370 pc with an uncertainty of 400–500 pc. Employing the physical HR diagram with the coordinates logL/L{sub ⊙} versus logT{sub eff} and the Padova isochrones, the cluster age is found to be between 300 and 350 Myr. Among the cluster members we identified six red giants of spectral classes G5–G8 and luminosities II–III, 17 Am stars, one Ap star, and one B5 blue straggler. The extinction shows a steep rise up to ∼2.0 mag at 300–700 pc, caused by the extensions of the dust cloud LDN 970 and the Great Cygnus Rift, and up to ∼2.5 mag at the edge of the Perseus arm at 3.0 kpc. The extinction is almost constant between 0.9 and 2.5 kpc from the Sun. The average extinction of the cluster members is 2.54 mag. A systematic error of color excesses found in the Argonaut calculator results is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral Mesh-Free Quadrature for Planar Regions Bounded by Rational Parametric Curves

This article presents spectral, mesh-free, Green’s theorem-based numerical quadrature schemes for integrating functions over planar regions bounded by rational parametric curves. Our algorithm proceeds in two steps: (1) We first find intermediate quadrature rules for line integrals along the region’s boundary curves corresponding to Green’s theorem. (2) We then use a high-order quadrature rule to compute the numerical antiderivative of the integrand along a coordinate axis, which is used to evaluate the Green’s theorem line integral. We present two methods to compute the intermediate quadrature rule. The first is spectrally accurate (it converges faster than any algebraic order with respect to number of quadrature points) and is relatively easy to implement, but has no guarantee of polynomial exactness. The second guarantees exactness for polynomial integrands up to a pre-specified degree with an a priori-known number of quadrature points and retains the convergence properties of the first, but is slightly more complicated. The quadrature schemes have applications to computation of geometric moments, immersogeometric analysis, conservative field transfer between high-order meshes, and initialization of multi-material simulations with rational geometry. We compare the quadrature schemes produced using our method to other methods in the literature and show that they are much more efficient both in terms of number of quadrature points and computational time. We provide an open-source implementation of the algorithm in MATLAB.

97 MATHEMATICS AND COMPUTING↗

A method of improving sensitivity of carbon/oxygen well logging for low porosity formation

Carbon/Oxygen (C/O) spectral logging technique has been widely used to determine residual oil saturation and the evaluation of water flooded layer. In order to improve the sensitivity of the technique for low – porosity formation, Gaussian and linear models are applied to fit the peaks of measured spectra to obtain the characteristic coefficients. Standard spectra of carbon and oxygen are combined to establish a new carbon /oxygen value calculation method, and the robustness of the new method is cross – validated with known mixed gamma ray spectrum. Formation models for different porosities and saturations are built using Monte Carlo method. The responses of carbon/oxygen which are calculated by conventional energy window method, and the new method is applied to oil saturation under low porosity conditions. The results show the new method can reduce the effects of gamma rays contaminated by the interaction between neutrons and other elements on carbon/oxygen ratio, and therefore can significantly improve the response sensitivity of carbon/oxygen well logging to oil saturation. The new method improves greatly carbon/oxygen well logging in low porosity conditions.

02 PETROLEUM↗

Improved reconstruction stability for chemical shift encoded hyperpolarized 13 C magnetic resonance spectroscopic imaging using k‐t spiral acquisitions

Purpose A multiecho, field of view (FOV)‐oversampled k‐t spiral acquisition and direct iterative decomposition of water and fat with echo asymmetry and least‐squares estimation reconstruction is demonstrated to improve the stability of hyperpolarized 13 C magnetic resonance spectroscopic imaging (MRSI) in the presence of signal ambiguities attributed to low‐SNR (signal‐to‐noise‐ratio) species, local uncertainties in metabolite peaks, and echo‐to‐echo signal inconsistencies. Theory k‐t spiral acquisitions redistribute readout points to be more densely spaced radially in k‐space by acquiring an FOV and matrix that are oversampled by η . These more densely spaced spiral turns constitute effective intraspiral echoes and can supplement conventional interspiral echoes to improve spectral separation and reduce spectral cross‐talk to better resolve 13 C‐labeled species for spectroscopic imaging. Methods Digital simulations and imaging phantom experiments were performed for a range of interspiral echo spacings and η using multiecho, k‐t spiral acquisitions. Image spectral cross‐talk artifacts were evaluated both qualitatively and quantitatively as the percent error in measured metabolite ratios. In vivo murine experiments evaluated the feasibility of multiecho, k‐t spiral [1‐ 13 C]pyruvate MRSI to reduce spectral cross‐talk for 3 scenarios of different expected reconstruction stability. Results Digital simulations and imaging phantom experiments both demonstrated reduced or comparable image spectral cross‐talk and percent errors in measured metabolite ratios with increasing η and better choices of echo spacings. In vivo images displayed markedly reduced spectral cross‐talk in lactate images acquired with η = 7 versus η = 1. Conclusion The precision of hyperpolarized 13 C metabolic imaging and quantification in the presence of low‐SNR species, local uncertainties in metabolite resonances, and echo‐to‐echo signal inconsistencies can be improved with the use of FOV‐oversampled k‐t spiral acquisitions.

Macdonald, Erin B.↗