Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stream Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

A high fidelity and user-friendly equation-oriented optimization model for carbon capture using a novel water-lean solvent

Research Triangle Institute (RTI) International and SLB have developed a novel water-lean solvent technology for carbon capture, demonstrating low specific reboiler duty (SRD) values at capture rates exceeding 90%. At the Technology Centre Mongstad (TCM) pilot plant, the technology achieved an SRD of 2.55 GJ/t-CO2 at 95% capture, utilizing an intercooler and a 5°C temperature approach in the lean/rich solvent cross exchanger. To meet varying carbon capture targets for Front End Engineering and Design (FEED) studies and to enable real-time optimization and advanced process control, an efficient optimization model is required. This model needs to minimize energy demand for a given capture rate and determine optimal operating parameters in response to fluctuating flue gas conditions. While an existing Aspen Plus simulation model, developed by RTI and SLB, accurately matches TCM plant data, its sequential modular (SM) strategy is too slow for real-time applications due to recycle streams and tight heat integration inherent in solvent-based carbon capture processes. Although an equation-oriented (EO) modeling strategy is more suitable for optimizing these processes, its adoption has been limited by several factors: feature limitations in Aspen Plus EO mode (e.g., lack of balance block support), a less user-friendly interface for variable identification and loop solving, complex troubleshooting of convergence issues, and the necessity for accurate initial values.

carbon capture↗

Organic-matter decomposition along a temperature gradient in a forested headwater stream

Here, we used a natural temperature gradient in Walker Branch, a spring-fed forested stream in eastern Tennessee, USA, to examine the influence of temperature on organic-matter decomposition. These upstream sites are warmer than downstream sites in winter and are cooler than downstream sites in summer. We used a cotton-strip assay to examine breakdown of a substrate of uniform quality (95% cellulose) along the temperature gradient monthly for 2 y and litter bags to examine the interactive effects of leaf-litter quality (labile red maple [Acer rubrum] and tulip poplar [Liriodendron tulipifera], and less labile white oak [Quercus alba]), invertebrates, and temperature on breakdown rates along the downstream temperature gradient for 90 d in winter. Cotton-strip tensile loss and leaf-litter breakdown rates were highly variable. Tensile-loss rates likely were driven by a combination of daily and diel temperature, discharge, streamwater nutrients that varied seasonally and spatially along the temperature gradient. Leaf litter breakdown rates tended to be faster in warmer upstream sites (red maple = 0.0452/d, tulip poplar = 0.0376/d, white oak = 0.0142/d) and slower in cooler downstream sites (red maple = 0.0312/d, tulip poplar = 0.0236/d, white oak = 0.0107/d), and breakdown rates were positively correlated with total invertebrate density. Furthermore, temperature sensitivity of decomposition was similar among the 3 litter types. These results highlight the high degree of spatial and temporal heterogeneity that can exist for ecosystem processes and their drivers. Quantifying this heterogeneity is important when scaling functional metrics to stream and watershed scales and for understanding how organic-matter processing will respond to the warmer streamwater temperatures expected as a result of global climate change.

59 BASIC BIOLOGICAL SCIENCES↗

Processing and properties of a solid energy fuel from municipal solid waste (MSW) and recycled plastics

Highlights: • Briquetting was used to produce solid fuels from municipal solid waste and recycled plastics. • Optimal drying, processing temperature and pressure were found to produce stable briquettes. • Addition of waste plastics yielded heating values comparable with typical coal feedstocks. • This processing method improves utilization of paper and plastic diverted from landfills. - Abstract: Diversion of waste streams such as plastics, woods, papers and other solid trash from municipal landfills and extraction of useful materials from landfills is an area of increasing interest especially in densely populated areas. One promising technology for recycling municipal solid waste (MSW) is to burn the high-energy-content components in standard coal power plant. This research aims to reform wastes into briquettes that are compatible with typical coal combustion processes. In order to comply with the standards of coal-fired power plants, the feedstock must be mechanically robust, free of hazardous contaminants, and moisture resistant, while retaining high fuel value. This study aims to investigate the effects of processing conditions and added recyclable plastics on the properties of MSW solid fuels. A well-sorted waste stream high in paper and fiber content was combined with controlled levels of recyclable plastics PE, PP, PET and PS and formed into briquettes using a compression molding technique. The effect of added plastics and moisture content on binding attraction and energy efficiency were investigated. The stability of the briquettes to moisture exposure, the fuel composition by proximate analysis, briquette mechanical strength, and burning efficiency were evaluated. It was found that high processing temperature ensures better properties of the product addition of milled mixed plastic waste leads to better encapsulation as well as to greater calorific value. Also some moisture removal (but not complete) improves the compacting process and results in higher heating value. Analysis of the post-processing water uptake and compressive strength showed a correlation between density and stability to both mechanical stress and humid environment. Proximate analysis indicated heating values comparable to coal. The results showed that mechanical and moisture uptake stability were improved when the moisture and air contents were optimized. Moreover, the briquette sample composition was similar to biomass fuels but had significant advantages due to addition of waste plastics that have high energy content compared to other waste types. Addition of PP and HDPE presented better benefits than addition of PET due to lower softening temperature and lower oxygen content. It should be noted that while harmful emissions such as dioxins, furans and mercury can result from burning plastics, WTE facilities have been able to control these emissions to meet US EPA standards. This research provides a drop-in coal replacement that reduces demand on landfill space and replaces a significant fraction of fossil-derived fuel with a renewable alternative.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Relationship between isotope ratios in precipitation and stream water across watersheds of the National Ecological Observation Network

The timescales associated with precipitation moving through watersheds reveal processes that are critical to understanding many hydrologic systems. Measurements of environmental stable water isotope ratios (δ 2 H and δ 18 O) have been used as tracers to study hydrologic timescales by examining how long it takes for incoming precipitation tracers become stream discharge, yet limited measurements both spatially and temporally have bounded macroscale evaluations so far. Here in this observation driven study across North American biomes within the National Ecological Observation Network (NEON), we examined δ 18 O and δ 2 H stable water isotope in precipitation (δP) and stream water (δQ) at 26 co-located sites. With an average 54 precipitation samples and 139 stream water samples per site collected over 2014–2022, assessment of local meteoric water lines and local stream water lines showed geographic variation across North America. Taking the ratio of estimated seasonal amplitudes of δP and δQ to calculate young water fractions (F yw ), showed a Fyw range from 1% to 93% with most sites having F yw below 20%. Calculate d mean transit times (MTT) based on a gamma convolution model showed a MTT range from 0.10 to 13.2 years, with half of the sites having MTT estimates lower than 2 years. Significant correlations were found between the F yw and watershed area, longest flow length, and the longest flow length/slope. Significant correlations were found between MTT and site latitude, longitude, slope, clay fraction, temperature, precipitation magnitude, and precipitation frequency. The significant correlations between water timescale metrics and the environmental characteristics we report share some similarities with those reported in prior studies, demonstrating that these quantities are primarily driven by site or area specific factors. The analysis of isotope data presented here provides important constraints on isotope variation in North American biomes and the timescales of water movement through NEON study sites.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Scoping Tests Of Decontamination Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of glass waste. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task seeks to examine the potential treatment of this stream to remove radionuclides and subsequently disposition the decontaminated stream elsewhere, such as the Effluent Treatment Facility (ETF), for example. The treatment process envisioned is very similar to that used for the Actinide Removal Process (ARP) that has been operating for years at the Savannah River Site (SRS), and focuses on using mature radionuclide removal technologies that are also compatible with longterm tank storage and immobilization methods. For this new application, testing is needed to demonstrate acceptable treatment sorbents and precipitating agents and measure decontamination factors for additional radionuclides in this unique waste stream. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet and will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. One of the radionuclides that is volatile and expected to be in high concentration in this LAW Off-Gas Condensate stream is Technetium-99 ( 99 Tc). Technetium will not be removed from the aqueous waste in the Hanford WTP, and will primarily end up immobilized in the LAW glass by repeated recycle of the off-gas condensate into the LAW melter. Other radionuclides that are also expected to be in appreciable concentration in the LAW Off-Gas Condensate are 129 I, 90 Sr, 137 Cs, and {sup 241}Am. This report discusses results of preliminary radionuclide decontamination testing of the simulant. Testing examined use of Monosodium Titanate (MST) to remove 90 Sr and actinides, inorganic reducing agents for 99 Tc, and zeolites for 137 Cs. Test results indicate that excellent removal of 99 Tc was achieved using Sn(II)Cl 2 as a reductant, coupled with sorption onto hydroxyapatite, even in the presence of air and at room temperature. This process was very effective at neutral pH, with a Decontamination Factor (DF) >577 in two hours. It was less effective at alkaline pH. Conversely, removal of the cesium was more effective at alkaline pH, with a DF of 17.9. As anticipated, ammonium ion probably interfered with the Ionsiv®a IE-95 zeolite uptake of 137 Cs. Although this DF of 137 Cs was moderate, additional testing is expected to identify more effective conditions. Similarly, Monosodium Titanate (MST) was more effective at alkaline pH at removing Sr, Pu, and U, with a DF of 319, 11.6, and 10.5, respectively, within 24 hours. Actually, the Ionsiv® IE-95, which was targeting removal of Cs, was also moderately effective for Sr, and highly effective for Pu and U at alkaline pH. The only deleterious effect observed was that the chromium co-precipitates with the {sup 99}Tc during the SnCl 2 reduction. This effect was anticipated, and would have to be considered when managing disposition paths of this stream. Results of this separation testing indicate that sorption/precipitation was a viable concept and has the potential to decontaminate the stream. All radionuclides were at least partially removed by one or more of the materials tested. Based on the results, a possible treatment scenario could involve the use of a reductive precipitation agent (SnCl 2 ) and sorbent at neutral pH to remove the Tc, followed by pH adjustment and the addition of zeolite (Ionsiv® IE-95) to remove the Cs, Sr, and actinides. Addition of MST to remove Sr and actinides may not be needed. Since this was an initial phase of testing, additional tasks to improve separation methods were expected to be identified. Primarily, further testing is needed to identify the conditions for the decontamination process. Once these conditions are established, follow-on tasks likely include evaluation and testing of applicable solid-liquid separation technologies, slurry rheology measurements, composition variability testing and evaluations, corrosion and erosion testing, slurry storage and immobilization investigations, and decontaminated LAW Off-Gas Condensate evaporation and solidification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cooling process and system for dry cooling power plants

A seasonal process that captures stores and uses water in an ambient temperature-dependent manner to improve the efficiency of a natural gas power plant, comprising: (a) providing a natural gas power plant, the natural gas power plant having a flue gas stream, a cooling tower, and a gas turbine; (b) providing a water collection system; (c) providing a water storage facility; wherein the flue gas stream comprises uncondensed water vapor; wherein the water collection system is operably connected to the flue gas stream and the flue gas stream is directed to flow, at least in part, into the water collection system; wherein the water collection system is operably connected to the water storage facility; wherein the water storage facility is operably connected to the cooling tower and the water storage facility is operably connected to the gas turbine; wherein the process comprises the following steps of condensing flue gas water or using water that has been condensed from the flue gas stream based on outdoor ambient dry bulb temperature: (I) Only condensing water from the flue gas stream to produce a condensed water stream if outdoor ambient dry bulb temperature is less than 85° F.; (II) Only using condensed water to spray cool the cooling tower if outdoor ambient dry bulb temperature is at least 85° F.; (III) Only using condensed water to fog cool the gas turbine if outdoor ambient dry bulb temperature is at least 55° F.; wherein condensed water that is not immediately used to cool the cooling tower or to fog cool the gas turbine is stored in the water storage facility; and wherein the process uses a total amount of water on an annual basis to cool the cooling tower and to fog cool the gas turbine that does not exceed the annual amount of water condensed from the flue gas stream. Optionally, the process has a cooling tower that is a dry cooling tower and condensed water is used to spray cool the dry cooling tower, or the cooling tower is a wet cooling tower, or the cooling tower is a hybrid wet-dry cooling tower. The process may further comprise a water collection system having a three stage desiccant cycle and a calcium chloride desiccant that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condensing column that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condenser and a rotating wheel heat exchanger that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure, or further comprises plastic piping or plastic vessels. The coefficient of performance for the cooling process is optionally at least 2.0.

Srinivas, Girish↗

A Remote Absorption Process for Disposal of Evaporate and Reverse Osmosis Concentrates

Many commercial nuclear plants and DOE facilities generate secondary waste streams consisting of evaporator bottoms and reverse osmosis (RO) concentrate. Since liquids are not permitted in disposal facilities, these waste streams must be converted to dry solids, either by evaporation to dried solids or by solidification to liquid-free solids. Evaporation of the liquid wastes reduces their volume, but requires costly energy and capital equipment. In some cases, concentration of the contaminants during drying can cause the waste to exceed Class A waste for nuclear utilities or exceed DOE transuranic limits. This means that disposal costs will be increased, or that, when the Barnwell, SC disposal site closes to waste outside of the Atlantic Compact in July 2008, the waste will be precluded from disposal for the foreseeable future). Solidification with cement agents requires less energy and equipment than drying, but results in a volume increase of 50-100%. The doubling or tripling of waste weight, along with the increased volume, sharply increases shipping and disposal costs. Confronted with these unattractive alternatives, Diversified Technologies Services (DTS), in conjunction with selected nuclear utilities and D and D operations at Rocky Flats, undertook an exploratory effort to convert this liquid wastewater to a solid without using cement. This would avoid the bulking effect of cement, and permit the waste to be disposed of the Energy Solutions facility in Utah as well as some DOE facilities. To address the need for an attractive alternative to drying and cement solidification, a test program was developed using a polymer absorbent media to convert the concentrate streams to a liquid-free waste form that meets the waste acceptance criteria of the pertinent burial sites. Two approaches for mixing the polymer with the liquid were tested: mechanical mixing and in-situ incorporation. As part of this test program, a process control program (PCP) was developed that is 100% scalable from a concentrate test sample as small as 50 grams to full-scale processing of 100 cubic foot containers or larger. In summary: The absorption process offers utilities a viable and less costly alternative to on-site drying or solidification of concentrates. The absorption process can be completed by site personnel or by a vendor as a turnkey service. The process is suitable for multiple types of waste, including RO and evaporator concentrates, sludges, and other difficult to process waters and wet solids. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of Process Intensification of Water-Gas Shift Reaction Using a Microreactor with Integrated Cooling

Hydrogen is an increasingly attractive low-carbon energy carrier for a variety of stationary and mobile applications. The water-gas shift (WGS) reaction is a key processing step used for large-scale hydrogen production via the steam methane reforming process. However, the thermodynamics and kinetics of the reaction are such that standard two-stage adiabatic reactors used in these systems are large, increasing catalyst volume and cost. To intensify the process and realize the economical distributed production of hydrogen, adiabatic WGS microreactors with integrated cooling directly regulate the reaction temperature via integrated coolant channels to promote higher conversion within a smaller reactor volume. This study investigates the conversion efficiency of a single WGS microchannel operating under such cooling conditions. A COMSOL Multiphysics model is developed and validated with isothermal experimental data from the literature. The model is then used to evaluate improvements in conversion efficiency when the reaction is cooled via a specified wall temperature profile. Lastly, the model is modified to include cooling channels with a secondary fluid that can practically achieve a similar conversion profile as the specified wall temperature profile previously applied. Initial results show that reactor conversion can be significantly increased by the inclusion of appropriate cooling and that there is a potential for the recovery of energy from the reaction stream that can be used for other applications within the overall process.

energy recovery↗

Dual Layer Monolith ATR of Pyrolysis Oil for Distributed Synthesis Gas Production

We have successfully demonstrated a novel reactor technology, based on BASF dual layer monolith catalyst, for miniaturizing the autothermal reforming of pyrolysis oil to syngas, the second and most critical of the three steps for thermochemically converting biomass waste to liquid transportation fuel. The technology was applied to aged as well as fresh samples of pyrolysis oil derived from five different biomass feedstocks, namely switch-grass, sawdust, hardwood/softwood, golden rod and maple. Optimization of process conditions in conjunction with innovative reactor system design enabled the minimization of carbon deposit and control of the H2/CO ratio of the product gas. A comprehensive techno-economic analysis of the integrated process using in part, experimental data from the project, indicates (1) net energy recovery of 49% accounting for all losses and external energy input, (2) weight of diesel oil produced as a percent of the biomass to be ~14%, and (3) for a demonstration size biomass to Fischer-Tropsch liquid plant of ~ 2000 daily barrels of diesel, the price of the diesel produced is ~$\$$3.30 per gallon, ex. tax. However, the extension of catalyst life is critical to the realization of the projected economics. Catalyst deactivation was observed and the modes of deactivation, both reversible and irreversible were identified. An effective catalyst regeneration strategy was successfully demonstrated for reversible catalyst deactivation while a catalyst preservation strategy was proposed for preventing irreversible catalyst deactivation. Future work should therefore be focused on extending the catalyst life, and a successful demonstration of an extended (> 500 on-stream hours) catalyst life would affirm the commercial viability of the process.

09 BIOMASS FUELS↗

Explorer-II: Wireless Self-Powered Visual and NDE Robotic Inspection System for Live Gas Distribution Mains

Carnegie Mellon University (CMU) under contract from Department of Energy/National Energy Technology Laboratory (DoE/NETL) and co-funding from the Northeast Gas Association (NGA), has completed the overall system design, field-trial and Magnetic Flux Leakage (MFL) sensor evaluation program for the next-generation Explorer-II (X-II) live gas main Non-destructive Evaluation (NDE) and visual inspection robot platform. The design is based on the Explorer-I prototype which was built and field-tested under a prior (also DoE- and NGA co-funded) program, and served as the validation that self-powered robots under wireless control could access and navigate live natural gas distribution mains. The X-II system design ({approx}8 ft. and 66 lbs.) was heavily based on the X-I design, yet was substantially expanded to allow the addition of NDE sensor systems (while retaining its visual inspection capability), making it a modular system, and expanding its ability to operate at pressures up to 750 psig (high-pressure and unpiggable steel-pipe distribution mains). A new electronics architecture and on-board software kernel were added to again improve system performance. A locating sonde system was integrated to allow for absolute position-referencing during inspection (coupled with external differential GPS) and emergency-locating. The power system was upgraded to utilize lithium-based battery-cells for an increase in mission-time. The resulting robot-train system with CAD renderings of the individual modules. The system architecture now relies on a dual set of end camera-modules to house the 32-bit processors (Single-Board Computer or SBC) as well as the imaging and wireless (off-board) and CAN-based (on-board) communication hardware and software systems (as well as the sonde-coil and -electronics). The drive-module (2 ea.) are still responsible for bracing (and centering) to drive in push/pull fashion the robot train into and through the pipes and obstacles. The steering modules and their arrangement, still allow the robot to configure itself to perform any-angle (up to 90 deg) turns in any orientation (incl. vertical), and enable the live launching and recovery of the system using custom fittings and a (to be developed) launch-chamber/-tube. The battery modules are used to power the system, by providing power to the robot's bus. The support modules perform the functions of centration for the rest of the train as well as odometry pickups using incremental encoding schemes. The electronics architecture is based on a distributed (8-bit) microprocessor architecture (at least 1 in ea. module) communicating to a (one of two) 32-bit SBC, which manages all video-processing, posture and motion control as well as CAN and wireless communications. The operator controls the entire system from an off-board (laptop) controller, which is in constant wireless communication with the robot train in the pipe. The sensor modules collect data and forward it to the robot operator computer (via the CAN-wireless communications chain), who then transfers it to a dedicated NDE data-storage and post-processing computer for further (real-time or off-line) analysis. The prototype robot system was built and tested indoors and outdoors, outfitted with a Remote-Field Eddy Current (RFEC) sensor integrated as its main NDE sensor modality. An angled launcher, allowing for live launching and retrieval, was also built to suit custom angled launch-fittings from TDW. The prototype vehicle and launcher systems are shown. The complete system, including the in-pipe robot train, launcher, integrated NDE-sensor and real-time video and control console and NDE-data collection and -processing and real-time display, were demonstrated to all sponsors prior to proceeding into final field-trials--the individual components and setting for said acceptance demonstration are shown. The launcher-tube was also used to verify that the vehicle system is capable of operating in high-pressure environments, and is safely deployable using proper evacuating/purging techniques for operation in the potentially explosive natural gas environment. The test-setting and environment for safety-certification of the X-II robot platform and the launch and recovery procedures, is shown. Field-trials were successfully carried out in a live steel pipeline in Northwestern Pennsylvania. The robot was launched and recovered multiple times, travelling thousands of feet and communicating in real time with video and command-and-control (C&C) data under remote operator control from a laptop, with NDE sensor-data streaming to a second computer for storage, display and post-processing. Representative images of the activities and systems used in the week-long field-trial are shown. CMU also evaluated the ability of the X-II design to be able to integrate an MFL sensor, by adding additional drive-/battery-/steering- and support-modules to extend the X-II train.

03 NATURAL GAS↗

The Artificial Scientist: in-Transit Machine Learning of Plasma Simulations

Large-scale simulations or scientific experiments produce petabytes of data per run. This poses massive challenges for I/O and storage when scientific analysis workflows are run manually offline. Unsupervised deep learning-based techniques to extract patterns and non-linear relations from these large amounts of data provide a way to build scientific understanding from raw data, reducing the need for manual pre-selection of analysis steps, but require exascale compute and memory to process the full dataset available. In this paper, we demonstrate a heterogeneous streaming workflow in which plasma simulation data is streamed directly to a Machine Learning (ML) application training a model on the simulation data in-transit, completely circumventing the capacity-constrained filesystem bottleneck. This workflow employs openPMD to provide a high level interface to describe scientific data and also uses ADIOS2, to transfer volumes of data that exceed the capabilities of the filesystem. We employ experience replay to avoid catastrophic forgetting in learning from this non-steady state process in a continual manner and adapt it to improve model convergence while learning in-transit. As a proof-of-concept, we approach the ill-posed inverse problem of predicting particle dynamics from radiation in a particle-incell (PIConGPU) simulation of the Kelvin-Helmholtz instability (KHI). We detail hardware-software co-design challenges as we scale PIConGPU to full Frontier, the Top-1 system as of June 2024 Top500 list.

Kelling, Jeffrey [Helmholtz-Zentrum Dresden Rossen↗

Development of Novel Foaming Solutions for High Level Waste (HLW) Processing

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site’s Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical off gas products. The presence of amphiphilic particles in the waste slurry stabilizes the foam. Efficient processing of HLW requires foam control, as foamovers lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. While it controls foam, processing issues have arisen from its use. During DWPF chemical processing, antifoam must be effective up to 103°C and between a pH range of 3-13. Antifoam 747 is efficient at pH 6-8 but degrades outside this optimal pH range. Savannah River National Laboratory (SRNL) has identified multiple flammable antifoam degradation products during laboratory scale experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Projecting spatiotemporally explicit effects of climate change on stream temperature: A model comparison and implications for coldwater fishes

Conservation planners and resource managers seek information about how the availability and locations of cold-water habitats will change in the future and how these predictions vary among models. In this work, we used a physical process-based model to demonstrate the implications of climate change for streamflow and water temperature in two watersheds with distinctive flow regimes: the Snoqualmie watershed (WA) and Siletz watershed (OR), USA. Our model incorporated a downscaled ensemble of global climate model outputs and was calibrated with in situ and remotely sensed water temperatures. Furthermore, we compared predictions from our processed-based model to those from a publicly available and widely used statistical model. The process-based model projected greater changes in summer maximum water temperatures for the mixed-rain-snow Snoqualmie watershed than for the rain-dominated Siletz watershed as a result of the near-complete loss of winter snowpack and significant reduction in summer flow in the Snoqualmie watershed expected by the 2080s. Both models projected generally similar future spatial patterns of maximum water temperature in the two rivers, with cool reaches distributed farther upstream and fewer in number. However, the process-based model projected higher spatial heterogeneity in water temperature due to our spatially explicit simulation of streamflow and because we calibrated the model with spatially continuous remotely sensed water temperature data. We used stream temperature projections to assess the vulnerability of Pacific salmon and trout to changes in the spatial distribution of cold-water habitats during August by the 2080s. Results suggest that salmonids may have fewer summertime cold-water habitats in both watersheds. Projected stream warming may further limit particular species and life stages, especially in the Snoqualmie watershed. Our comparison of models highlights the importance of considering what might be gained by using a process-based model for evaluating and prioritizing management actions that mitigate climate impacts on cold-water habitats for stream fishes.

54 ENVIRONMENTAL SCIENCES↗

A co-registered in-situ and ex-situ dataset from wire arc additive manufacturing process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data-centric approach emphasizes leveraging sensor data available throughout the production process to optimize performance. Integration of extensive data analysis provides opportunities for improving precision, reducing waste, and enhancing the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes a comprehensive description of the deposition process, process parameters, welding characteristics and acoustic data collected in-situ, and X-Ray Computed Tomography data of the build.

42 ENGINEERING↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

Model Data Archive Associated with Manuscript "Fire-altered Carbon Pools Create Disturbance Memory in Stream Dissolved Organic Carbon"

This data package supports the publication “Fire-altered Carbon Pools Create Disturbance Memory in Stream Dissolved Organic Carbon” by Li et al. (2026). The package contains processed model inputs, configuration files, restart files, simulation outputs, scripts, and visualization products used to evaluate post-fire dissolved organic carbon (DOC) dynamics in the Naches River Watershed, Washington, USA, following the 2021 Schneider Springs Fire. The modeling workflow couples ELM-BGC, the biogeochemistry-enabled Energy Exascale Earth System Model Land Model; ATS, the Advanced Terrestrial Simulator for integrated surface-subsurface hydrology; and PFLOTRAN, a reactive transport model for multicomponent aqueous geochemistry. Together, these models simulate how wildfire-induced changes in vegetation, litter, coarse woody debris, and soil organic matter influence DOC production, transport, and reaction from burned hillslopes to stream networks. The archive includes preprocessed meteorological, geospatial, hydrologic, and biogeochemical forcing data; ELM-BGC-derived DOC source terms; ATS mesh files; PFLOTRAN reactive-transport inputs; model configuration files; spin-up and transient restart files; watershed-scale diagnostic outputs; stream concentration time series; and figures or visualization files used to inspect and reproduce key results. File types include Hierarchical Data Format 5 (HDF5) files for gridded forcing and model-coupling data, model input and configuration files for ELM-BGC, ATS, and PFLOTRAN, restart and simulation-output files generated by the modeling workflow, tabular or time-series diagnostic outputs, scripts for post-processing and figure generation, and image or visualization products associated with the manuscript. Use of the package depends on the intended task. Re-running the simulations requires the relevant modeling software, including ELM-BGC, ATS, and PFLOTRAN as ATS's geochemical engine. Inspecting outputs and reproducing figures requires Python with scientific plotting libraries such as Matplotlib, and three-dimensional model outputs may be viewed with ParaView. Geographic information system files or maps may be inspected with ArcGIS Pro or comparable GIS software. The data package is intended to enable traceability, reuse, and partial reproduction of the coupled land-to-watershed hydro-biogeochemical modeling workflow used to test how wildfire disturbance affects terrestrial carbon pools and downstream DOC dynamics.

ATS↗

REMOTE IN-CELL SAMPLING IMPROVEMENTS PROGRAM AT THESAVANNAH RIVER SITE (SRS) DEFENSE WASTE PROCESSING FACILITY (DWPF)

Remote Systems Engineering (RSE) of the Savannah River National Lab (SRNL) in combination with the Defense Waste Processing Facility(DWPF) Engineering and Operations has evaluated the existing equipment and processes used in the facility sample cells for 'pulling' samples from the radioactive waste stream and performing equipment in-cell repairs/replacements. RSE has designed and tested equipment for improving remote in-cell sampling evolutions and reducing the time required for in-cell maintenance of existing equipment. The equipment within the present process tank sampling system has been in constant use since the facility start-up over 17 years ago. At present, the method for taking samples within the sample cells produces excessive maintenance and downtime due to frequent failures relative to the sampling station equipment and manipulator. Location and orientation of many sampling stations within the sample cells is not conducive to manipulator operation. The overextension of manipulators required to perform many in-cell operations is a major cause of manipulator failures. To improve sampling operations and reduce downtime due to equipment maintenance, a Portable Sampling Station (PSS), wireless in-cell cameras, and new commercially available sampling technology has been designed, developed and/or adapted and tested. The uniqueness of the design(s), the results of the scoping tests, and the benefits relative to in-cell operation and reduction of waste are presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HLW Processing for Complementary Disposition Strategy: Development and Testing of Glass and Feed Formulations

The objective of the work described herein was to develop and identify HLW glass compositions and glass forming additive blends for vitrification of selected HLW streams, which have undergone various degrees of washing but no other pretreatment, while maintaining high WLs, high processing rates, and acceptable glass properties. The glass formulations were actively designed and based on previous formulation experience and testing at VSL. The WTP baseline HLW property-composition models were used to select glass formulations for testing and to predict various glass properties. Crucible-scale fabrication of the HLW glasses that were formulated was performed and the product glasses were characterized with respect to select properties. A total of 10 HLW glasses were developed and tested for five fully washed waste batches and one singly washed waste batch.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗