Search NASASearch

SEARCH · Search NASA

Results for “Thermal Design and Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,565 records · Page 81

Performance Results of a Digital Test Signal Generator

Performance results of a digital test signal-generator hardware-demonstration unit are reported. Capabilities available include baseband and intermediate frequency (IF) spectrum generation, for which test results are provided. Repeatability in the setting of a given signal-to-noise ratio (SNR) when a baseband or an IF spectrum is being generated ranges from 0.01 dB at high SNR's or high data rates to 0.3 dB at low data rates or low SNR's. Baseband symbol SNR and carrier SNR (P c /N o ) accuracies of 0.1 dB were verified with the built-in statistics circuitry. At low SNR's that accuracy remains to be fully verified. These results were confirmed with measurements from a demodulator synchronizer assembly for the baseband spectrum generation, and with a digital receiver (Pioneer 10 receiver) for the IF spectrum generation.

B O Gutierrez-Luaces

Nickel hydrogen/nickel cadmium battery trade studies

Nickel Hydrogen cell and battery technology has matured to the point where a real choice exists between Nickel Hydrogen and Nickel Cadmium batteries for each new spacecraft application. During the past few years, a number of spacecraft programs have been evaluated at Hughes with respect to this choice, with the results being split about fifty-fifty. The following paragraphs contain criteria which were used in making the battery selection.

Stadnick, S. J.

Development of nickel hydrogen battery expert system

The Hubble Telescope Battery Testbed employs the nickel-cadmium battery expert system (NICBES-2) which supports the evaluation of performances of Hubble Telescope spacecraft batteries and provides alarm diagnosis and action advice. NICBES-2 also provides a reasoning system along with a battery domain knowledge base to achieve this battery health management function. An effort to modify NICBES-2 to accommodate nickel-hydrogen battery environment in testbed is described.

Shiva, Sajjan G.

The Study of Dopant Segregation Behavior During the Growth of GaAs in Microgravity

An investigation into the segregation behavior of selenium doped gallium arsenide during directional solidification in the microgravity environment was conducted using the Crystal Growth Furnace (CGF) aboard the first United States Microgravity Laboratory (USML-1). The two crystals grown were 1.5 cm in diameter and 16.5 cm in length with an initial melt length of 14 cm. Two translation periods were executed, the first at 2.5 microns/s and after a specified time, which was different between the two experiments, the translation rate was doubled to 5.0 microns/s. The translation was then stopped and the remaining sample melt was solidified using a gradient freeze technique in the first sample and a rapid solidification in the second experiment. Measurement of the selenium dopant distribution, using quantitative infrared transmission imaging, indicates that the first sample initially achieved diffusion controlled growth as desired. However, after about 1 cm of growth, the segregation behavior was driven from a diffusion controlled growth regime to a complete mixing regime. Measurements in the second flight sample indicated that the growth was always in a complete mixing regime. In both experiments, voids in the center line of the crystal, indicative of bubble entrapment, were found to correlate with the position in the crystal when the translation rates were doubled.

D H Matthiesen

Development of a battery status monitor

A prototype battery status monitor system has been developed. The functions of the system are: (1) to provide the energy status of the battery, (2) to measure and transmit basic battery parameters, (3) to process these measurements required to determine abnormal functioning of the battery, and (4) to transmit warning signals of the abnormal condition along with a go/no go signal. The system was developed for use with the space shuttle.

Zimmerman, R. I.

Vaporization Would Cool Primary Battery

Temperature of discharging high-power-density primary battery maintained below specified level by evaporation of suitable liquid from jacket surrounding battery, according to proposal. Pressure-relief valve regulates pressure and boiling temperature of liquid. Less material needed in cooling by vaporization than in cooling by melting. Technique used to cool batteries in situations in which engineering constraints on volume, mass, and location prevent attachment of cooling fins, heat pipes, or like.

Bhandari, Pradeep

A new battery charger/discharger converter

A new optimum topology dc-to-dc switching converter is extended to provide bidirectional current flow. The resulting two-quadrant converter can be employed to eliminate the discontinuous current mode in normal unidirectional applications, but is especially suited for spacecraft battery conditioning as a charge-discharge regulator in place of the conventional separate converters. Implementation of the control features and the battery charge current and voltage limits are discussed.

Middlebrook, R. D.

29th Aerospace Mechanisms Symposium

The proceedings of the 29th Aerospace Mechanisms Symposium, which was hosted by NASA Johnson Space Center and held at the South Shore Harbour Conference Facility on May 17-19, 1995, are reported. Technological areas covered include actuators, aerospace mechanism applications for ground support equipment, lubricants, pointing mechanisms joints, bearings, release devices, booms, robotic mechanisms, and other mechanisms for spacecraft.

Booms

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Otto J Gregory

A method for battery activation

A technique to activate nickel cadmium batteries is described. The method shortened the time required for activation, eliminated the temperature rise in the batteries, and produced a voltage on the discharge that was better than when the C/20 was run for 48 hours during tests. Various methods of activation are described and evaluated. Results of alternate conditioning charge schemes are presented along with voltage/temperature characteristics for multiple level nickel cadmium battery chargers.

Halpert, G.

Chapter 19A – Radar Cross Section

The material in this Section will provide the novice Flight Test Engineer (FTE) with a brief overview of the radar cross section (RCS) concept. Brief details of radar range descriptions, operations, target calibrations, and data reduction are included. It is noted that these range operations concentrate on the "static" test range rather than the much more sophisticated "dynamic" test range. The dynamic test range is what the FTE will probably work with. Radar reflectivity measurement has developed over the last two decades from a relatively simple endeavor involving the measurement of target RCS amplitude statistics to involving wide band, coherent systems that can measure high resolution images of targets as well as, in many cases, the polarization and phasing properties. This rapid growth in RCS technology has occurred because of the increased use of radar in today's commercial and military systems. In general, the goal for commercial systems is to enhance radar reflectivity, whereas the military goal is to reduce radar reflectivity. Also, classification and identification are important for military purposes because in adverse weather radar may be the only system that may be capable of separating enemy targets from friendly ones. This Section will discuss the fundamentals of RCS. Since the flight test techniques associated with RCS measurements are very similar to those of antenna pattern measurements, both will be presented at the same time in Section 19B Antenna Radiation Pattern Measurements.

Robert W Borek

Silazane to silica

Thin film silica and/or methyl silicone were detected on most external surfaces of the retrieved LDEF. Known sources of silicone in or on the LDEF appear inadequate to explain the ubiquitous presence of the silica and silicone films. Hexamethyldisilazane (HMDS) was used as the Challenger tile waterproofing compound for the Challenger/LDEF deployment mission. HMDS releases NH3 which depolymerizes silicone RTV's. Polyurethanes were also attacked. Much of the silica/silicone contamination of LDEF resulted from HMDS.

Gale A. Harvey

Space Shuttle Main Engine Propellant Path Leak Detection Using Sequential Image Processing

Initial research in this study using theoretical radiation transport models established that the occurrence of a leak is accompanies by a sudden but sustained change in intensity in a given region of an image. In this phase, temporal processing of video images on a frame-by-frame basis was used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter. The absolute value of the resulting discrete sequence is then taken and compared to a threshold value to produce the binary leak/no leak decision at each point in the image. Alternatively, averaging over the full frame of the output image produces a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Laboratory experiments were conducted in which artificially created leaks on a simulated SSME background were produced and recorded from a visible wavelength video camera. This data was processed frame-by-frame over the time interval of interest using an image processor implementation of the leak detection algorithm. In addition, a 20 second video sequence of an actual SSME failure was analyzed using this technique. The resulting output image sequences and plots of the full frame mean value versus time verify the effectiveness of the system.

L Montgomery Smith

Modeling Ni-Cd performance. Planned alterations to the Goddard battery model

The Goddard Space Flight Center (GSFC) currently has a preliminary computer model to simulate a Nickel Cadmium (Ni-Cd) performance. The basic methodology of the model was described in the paper entitled Fundamental Algorithms of the Goddard Battery Model. At present, the model is undergoing alterations to increase its efficiency, accuracy, and generality. A review of the present battery model is given, and the planned charges of the model are described.

Jagielski, J. M.

Hypervelocity Impact Testing of Nickel Hydrogen Battery Cells

Nickel-Hydrogen (Ni/H2) battery cells have been used on several satellites and are planned for use on the International Space Station. In January 1992, the NASA Lewis Research Center (LeRC) conducted hypervelocity impact testing on Ni/H2 cells to characterize their failure modes. The cell's outer construction was a 24 mil-thick Inconel 718 pressure vessel. A sheet of 1.27 cm thick honeycomb was placed in front of the battery cells during testing to simulate the on-orbit box enclosure. Testing was conducted at the NASA White Sands Test Facility (WSTF). The hypervelocity gun used was a 7.6 mm (0.30 caliber) two-stage light gas gun. Test were performed at speeds of 3, 6, and 7 km/sec using aluminum 2017 spherical particles of either 4.8 or 6.4 mm diameter as the projectile. The battery cells were electrically charged to about 75 percent of capacity, then back-filled with hydrogen gas to 900 psi simulating the full charge condition. High speed film at 10,000 frames/sec was taken of the impacts. Impacts in the dome area (top) and the electrode area (middle) of the battery cells were investigated. Five tests on battery cells were performed. The results revealed that in all of the test conditions investigated, the battery cells simply vented their hydrogen gas and some electrolyte, but did not burst or generate any large debris fragments.

Frate, David T.

Space Suit Material Compatibility with Space Vehicle Coolant PMS-1.5R

During a survey of 82P on February 11, 2023, a shiny substance was detected on the Progress vehicle. The suspected material was PMS-1.5R, a low volatility silicone oil coolant used in the vehicle. Crew exposure to the coolant was a concern as the low volatility would increase residence time, the time a material will stay on a surface after exposure to vacuum. A review of space suit materials revealed several materials with compatibility concerns that could impact Extravehicular Activity (EVA) operations and safety. To understand the risk, space suit materials were exposed to a simulant and tested. This testing provided the basis for rationale generated to continue with EVA operations for US EVA 86 on April 2, 2023. This testing also served as the basis to assess impacts to ISS EMU hardware due to potential contamination brought inside ISS on Russian space suits during RS EVA 61 on October 25, 2023, following an ISS Russian Multipurpose Lab Module (MLM) radiator leak of the same fluid on October 9, 2023. This paper will discuss the testing performed and analyze test results impacts to EVA operations. Additional work was conducted to determine coolant evaporation rates in space vacuum and demonstrate that no significant unreacted coolant from the MLM leak would remain on ISS surfaces long enough to contaminate the EMU or affect the ISS ECLSS water separator.

Space Suit Materials

Bend Properties of Sapphire Fibers at Elevated Temperatures: Bend Survivability - 1

The effect of temperature on the bend radius that a c-axis-oriented sapphire fiber can withstand was determined for fibers of various diameter. Bend stress rupture tests were performed for times of 1-100 h and temperatures of 300-1700 C. Fibers would survive the bend test undeformed, would fracture or would deform. The bend survival radius was determined to be the radius above which no fibers fractured or deformed for a given time-temperature treatment. It was found that the ability of fibers to withstand curvature decreases substantially with time and increasing temperature and that fibers of smaller diameter (46-83 micron) withstood smaller bend radii than would be expected from just a difference in fiber diameter when compared with the bend results of the fibers of large diameter (144 micron). This was probably due to different flaw populations, causing high temperature bend failure for the tested sapphire fibers of different diameters.

Sapphire