Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

High Performing and Durable Pyrophosphate Based Composite Membranes for Intermediate Temperature Fuel Cells [Slides]

Objective: Develop a novel proton conducting electrolyte operating at >200°C with conductivity σ ≥ 100 mScm –1 and RH < 1%. Fabrication of membranes of less than 40μm thickness while retaining high conductivity will result in ASR <0.04 Ωcm 2 . Evaluate membrane durability in terms of crossover, shorting resistance, and open circuit voltage, as well as against temperature cycling. Relevance: Operating FCs in the intermediate temperature range has the potential to greatly reduce cost and simplify water and thermal management. This effort requires novel materials and approaches to meet DOE membrane performance and durability targets. MPP/Polymer composite membranes show promise in early development for application in IT-FCs for transportation applications. Approach: We have demonstrated that both cation dopants and phosphate precursor influence MPP conductivity and identified the most promising MPP compositions for membrane fabrication. The ceramic MPP materials are fabricated as a composite membrane in a 90:10 wt% ratio with Nafion. We have modified our membrane fabrication procedure to improve the density of our membranes. Accomplishments: We demonstrated through-plane membrane conductivity of 95mScm -1 at T > 200°C and RH<0.04bar with a thickness 50μm. We demonstrated FC performance up to 94hrs at 220°C and <1% RH with a 50μm thick membrane exhibiting an OCV of 0.98V and ASR of 0.08 Wcm 2 . Future work: Further decrease in ASR is expected by decreasing the membrane thickness to <40μm. ITPP with higher P:M ratio will be used to increase the conductivity of the starting material. Long term durability will be assessed against DOE technical targets

30 DIRECT ENERGY CONVERSION↗

SU-E-T-533: Evaluation of Dose Calculation Accuracy for Small Elongated Targets On the Edge Linac

Purpose: To evaluate output factors and dose calculation accuracy on a novel SRS linear accelerator, the Edge (Varian), for treatments of small, elongated targets using flattening filter free (FFF) beam. Methods: Total scatter/output factors (OF’s) for 24 elongated, small, high definition multi-leaf collimator (HDMLC)-defined fields were measured on the Edge machine using 6X FFF beam. 3 detectors were used in water tank: CC01 ion chamber (active volume 10cc), stereotactic photon diode (SFD) (active diameter 0.6mm, active thickness 0.06mm), Edge detector (active volume 0.0019cc). The 24 MLC apertures have widths ranging from 5 to 20mm and length/width ratio from 0.25 to 5. Readings were cross calibrated with CC04 at field size 3×3 cm. A beam model was developed using commissioning measurements for treatment planning in Eclipse (AAA, version 11). One representative patient case (IMRT, target volume 0.2cc, 4×4×14mm) was calculated using AAA 11 and delivered on the Edge. Results: Due to volume averaging effects, CC01 readings were 11.2±0.9% lower than SFD readings for 5mm field sizes. The Edge diode showed a uniform over-response of 2.6±0.7% compared to SFD. Calculation using AAA v11 showed the best agreement with SFD measurements (2.4±1.7% lower than SFD). The largest difference between AAA v11 and SFD occurs at 5mm field sizes. For the patient plan, dose delivered on Edge was measured to be 2.2% higher than AAA v11 calculation. Conclusion: Cross-calibrated SFD output measurements presented the best agreement with commissioned AAA v11 beam model. Field sizes smaller than 1cm posed challenges to both the detectors and the calculation algorithm. For the representative patient with small elongated target, AAA v11 and measurements agreed within ~2% on the Edge linac. Although encouraging, a more comprehensive study is required to validate the overall algorithmic accuracy.

60 APPLIED LIFE SCIENCES↗

The {sup 18}O(d,p){sup 19}O reaction and the ANC method

The neutron capture rate {sup 18}O(n,γ){sup 19}O is important for analysis of nucleosynthesis in inhomogeneous Big Bang models and also for models of processes in massive red giant stars and AGB stars. Angular distributions of the {sup 18}O(d,p){sup 19}O reaction were measured at a deuteron energy of 16.3 MeV in NPI in Řež, Czech Republic, with the aim to determine Asymptotic Normalization Coefficients which can then be used for indirect determination of the direct contribution to the {sup 18}O(n,γ){sup 19}O process. In the experiment, the gas target with {sup 18}O isotope of high purity 99.9 % was used thus eliminating any contaminating reactions. Reaction products were measured by the set of 8 ΔE-E telescopes consisting of thin and thick silicon surface-barrier detectors. Angular distributions of proton transfers corresponding to 6 levels of {sup 19}O up to the 4.1093 MeV excitation energy were determined. The analysis of angular distributions in the angular range from 6 to 64 degree including also the angular distribution of elastically scattered deuterons was carried out by means of ECIS and DWUCK codes. From the determined ANCs the direct contribution to the radiative capture {sup 18}O(n,γ){sup 19}O was deduced and compared with existing direct measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Loss of acoustic black hole effect in a structure of finite size

The Acoustic Black Hole (ABH) effect takes place in thin-walled structures with diminishing thickness as a result of the reduction in the bending wave speed. It was shown to exist as a broadband phenomenon, based on wave propagation theory in structures of semi-infinite size. The ABH effect exhibits appealing features for various applications, such as passive vibration control, energy harvesting, and sound radiation control. In this paper, we demonstrate the disappearance of the ABH effect in a finite beam at specific frequency ranges above the cut-on frequency, both experimentally and theoretically. Analyses show that the phenomenon takes place at frequencies which are close to the low order local resonant frequencies of the portion of the beam demarcated by the position of the excitation force. These frequencies can be predicted so that the phenomenon can be avoided for the targeted frequency ranges in ABH applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonstoichiometry, Structure, and Properties of BiFeO 3 Films

In this work, we explore the effect of growth conditions on the cation and anion chemistry, electrical leakage, conduction mechanisms, and ferroelectric and dielectric behavior of BiFeO 3 . Although it is possible to produce single-phase, coherently strained films in all cases, small variations in the pulsed-laser deposition growth process, specifically the laser repetition rate and target composition, result in films with chemistries ranging from 10% Bi-deficiency to 4% Bi-excess and films possessing Bi gradients as large a 6% across the film thickness. Corresponding variations and gradients in the O chemistry are also observed. As a result of the varying film chemistry, marked differences in surface and domain morphology are observed wherein Bi-deficiency stabilizes atomically smooth surfaces and ordered stripe domains. Subsequent investigation of the current-voltage response reveals large differences in leakage current density arising from changes in both the overall stoichiometry and gradients. In turn, the film stoichiometry drives variations in the dominant conduction mechanism including examples of Schottky, Poole-Frenkel, and modified Poole-Frenkel emission depending on the film chemistry. Lastly, slightly Bi-excess films are found to exhibit the best low-frequency ferroelectric and dielectric response while increasing Bi-deficiency worsens the low-frequency ferroelectric performance and reduces the dielectric permittivity.

36 MATERIALS SCIENCE↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

Using synthetic infrared spectra derived from n/k optical constants for standoff detection of chemical deposits

We report results from a recent field experiment to test the validity of using physics-based synthetic infrared spectra to serve as endmembers in a spectral database targeted at chemical deposits. Specifically, the optical constants n and k, (the real and imaginary part of the refractive index) were used to first model infrared reflectance spectra for different thicknesses of chemical layers (e.g. acetaminophen, methylphosphonic acid – MPA, etc.) on various conducting and insulating substrates such as aluminum, wood, and glass. In the experimental portion of the research, thin films of the solid and liquid analytes were deposited onto such substrates to form micron-thick layers of the analytes at different thicknesses: Standoff data from an imaging instrument were then recorded and analyzed to not only identify the different analytes, but also quantify the layer/deposit thickness. To gauge success, the detection results using the synthetic data were compared to the results from hemispherical reflectance (HRF) spectra that were collected for the same sample planchets measured in the field via standoff methods. Preliminary results indicate good agreement between the synthetic reference data as compared to the lab-measured HRF data in terms of their ability to quantitatively reduce longwave infrared data. Specifically, modeled IR spectra for acetaminophen on an aluminum planchet at various thicknesses (1, 2, 5, 10, 15, and 20 µm) were synthesized and compared with standoff field reflectance data as well as HRF laboratory reflectance spectra for two samples: a 5.2 µm- and 12.8 µm-thick layer of acetaminophen on aluminum. Using a first-order approximation, analysis of the field data estimates the thicknesses of the samples to be 2 and 10 µm for the two samples, respectively, while the HRF laboratory data yields thickness estimates of between 5-10 µm and 10 µm, respectively. Both yield reasonable estimates, with the uncertainty most likely due to factors yet to be accounted for in the synthetic spectra such as light scattering.

complex index of refraction, optical constants, hy↗

The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(Tl) full-field flat panel detector

The purpose of this study is to evaluate the performance of an antiscatter grid and its potential benefit on image quality for a full-field digital mammography (FFDM) detector geometry at energies typical for temporal subtraction contrast-enhanced (CE) breast imaging. The signal intensities from primary, scatter, and glare were quantified in images acquired with an a-Si/CsI(Tl) FFDM detector using a Rh target and a 0.27 mm Cu filter at tube voltages ranging from 35 to 49 kV. Measurements were obtained at the center of the irradiation region of 20-80 mm thick breast-equivalent phantoms. The phantoms were imaged with and without an antiscatter grid. Based on these data, the performance of the antiscatter grid was determined by calculating the primary and scatter transmission factors (T{sub P} and T{sub S}) and Bucky factors (B{sub f}). In addition, glare-to-primary ratios (GPRs) and scatter-to-primary ratios (SPRs) were quantified. The effect of the antiscatter grid on the signal-difference-to-noise ratio (SDNR) was also assessed. It was found that T{sub P} increases with kV but does not depend on the phantom thickness; T{sub P} values between 0.81 and 0.84 were measured. T{sub S} increases with kV and phantom thickness; T{sub S} values between 0.13 and 0.21 were measured. B{sub f} decreases with kV and increases with phantom thickness; B{sub f} ranges from 1.4 to 2.1. GPR is nearly constant, varying from 0.10 to 0.11. SPR without an antiscatter grid (SPR{sup -}) ranges from 0.35 to 1.34. SPR{sup -} decreases by approximately 9% from 35 to 49 kV for a given phantom thickness and is 3.5 times larger for an 80 mm thick breast-equivalent phantom than for a 20 mm thick breast-equivalent phantom. SPR with an antiscatter grid (SPR{sup +}) ranges from 0.06 to 0.31. SPR{sup +} increases by approximately 23% from 35 to 49 kV for a given phantom thickness; SPR{sup +} is four times larger for an 80 mm breast-equivalent phantom than for a 20 mm breast-equivalent phantom. When imaging a 25 mm PMMA plate at the same mean glandular dose with and without an antiscatter grid, the SDNR is 4% greater with a grid than without. For an 75mm PMMA plate, the SDNR is 20% greater with a grid. In conclusion, at the higher x-ray energy range used for CE-DM and CE-DBT, an antiscatter grid significantly reduces SPR and improves SDNR. These effects are most pronounced for thick breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Performance Computing to Quantify the Evolution of Microscopic Concentration Gradients During Flash Processing

During the Flash process, the cross section of a plain-carbon or a low-alloy steel is austenitized through rapid heating and transformed on rapid cooling to a predominantly martensite + bainite structure with small amounts of retained austenite. Unlike conventional heat treating, homogeneity is intentionally avoided during Flash processing of steels. The Flash process assembly consists of a pair of rolls that transfer the steel sheets through the heating and cooling stage of the thermal cycle. The initial microstructure of the steel consists of ferrite (body-centered cubic iron) + carbide ((Fe,X)mCn) mixture. The heating rate through the peak temperature is a function of temperature and reaches a peak of about 300-400°C/s and the cooling rate has a maximum value of 3,000-4,000°C/s. The on-heating phase transformations include carbide dissolution, austenite (face-centered cubic iron) nucleation and growth, and diffusion of carbon and other substitutional elements in the steel. The on-cooling phase transformations include formation of martensite (body-centered tetragonal phase containing supersaturated solute) and bainite (ferrite plates with or without fine carbides). In this project, the focus is on Fe-C-Cr steels that are currently Flash processed for armor applications. The modeling effort proposed here will help optimize the Flash thermal cycle for these low alloy steels to achieve the target performance, which is an ongoing effort at SFP Works. A significant feature of Flash processed Fe-C-Cr steels is the presence of scatter in the through-thickness in the sheet. The variability in hardness results from a variability in the bainite + martensite microstructure that is sensitive to the local chemical concentration of C and Cr. Such a chemical inhomogeneity is intentionally obtained in the Flash process. Although such a microstructural gradient is presumably responsible for the exceptional properties of the Flash processed steel, it is very important to quantify the gradients as a function of Flash variabilities in processing parameters and the input microstructure. Understanding the mechanistic pathway that leads to microstructural gradients could be ground-breaking and instrumental for achieving better process control and optimized microstructural state to meet application-specific strength-ductility requirements. Since the final microstructure depends on setting up precise solute concentration gradients through a rapid heating process, and transforming these regions into various phases, it is important to understand how small changes in steel chemistry, input microstructure (carbide size and distribution), and process variables (Flash thermal cycle) will impact the solute concentration gradients.

97 MATHEMATICS AND COMPUTING↗

Radiation GRMHD Models of Accretion onto Stellar-mass Black Holes. I. Survey of Eddington Ratios

We summarize results from a survey of radiation-dominated black hole accretion flows across a wide range of mass accretion rates, as well as two values of black hole spin and initial magnetic field geometry. These models apply an algorithm targeting direct solutions to the radiation transport equation in full general relativity and have been enabled by access to modern exascale computing systems. Super-Eddington accretion flows form geometrically thick radiation-pressure-supported disks that drive powerful equatorial outflows. A narrow funnel-shaped photosphere in the inner region results in very low radiative efficiencies in this regime. The structure of near- and sub-Eddington accretion depends on whether there is net vertical magnetic flux at the midplane of the disk. With net flux, the disk forms a thin, dense layer at the midplane surrounded by a magnetically dominated corona, whereas without net flux, the disk remains magnetically dominated everywhere. Although none of our models achieve the magnetically arrested disk regime, those with net vertical flux and a rapidly spinning black hole still produce powerful relativistic jets. Our calculations adopt simple opacity models (with scalings appropriate to stellar-mass black hole accretion). We discuss the application of our results to observations of X-ray binaries and ultraluminous X-ray sources such as Cyg X-3 and SS433. We also speculate on the application of our super-Eddington models to the interpretation of little red dots recently discovered by JWST.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the{sup 3}He permeability of DT-filled fused silica inertial confinement fusion (ICF) targets to study the effects of{sup 3}He on neutron emission during implosion

A set of laser implosion experiments were conducted at the OMEGA laser at the Univ. of Rochester, Laboratory for Laser Energetics (LLE) to study the effect of He concentration in DT-filled target shells on fusion yield in ICF implosions.. Eleven laser fusion shells consisting of 1100-{mu}m diameter, hollow, fused silica spheres with 4.6 to 4.7-{mu}m-thick walls were loaded with 520 kPa of deuterium-tritium (DT) and then with {sup 3}He (101.3 or 520 kPa). The {sup 3}He permeabilities of the shells were determined by measuring the pressure rate of rise into a system with known volume. A mathematical method was developed that relied on the experimental fill pressure and time, and the rate of rise data to solve differential equations using MathCAD to simultaneously calculate {sup 3}He permeability and initial {sup 3}He partial pressure inside the shell. Because of the high permeation rate for {sup 3}He out of the shells compared to that for DT gas, shells had to be recharged with {sup 3}He immediately before being laser imploded or 'shot' at LLE. The {sup 3}He partial pressure in each individual shell at shot time was calculated from the measured {sup 3}He permeability. Two different partial pressures of {sup 3}He inside the shell were shown to reduce neutron and gamma yields during implosion. (authors)

36 MATERIALS SCIENCE↗

FINAL FOCUS ION BEAM INTENSITY FROM TUNGSTEN FOIL CALORIMETER AND SCINTILLATOR IN NDCX-I

Laboratory high energy density experiments using ion beam drivers rely upon the delivery of high-current, high-brightness ion beams with high peak intensity onto targets. Solid-state scintillators are typically used to measure the ion beam spatial profile but they display dose-dependent degradation and aging effects. These effects produce uncertainties and limit the accuracy of measuring peak beam intensities delivered to the target. For beam tuning and characterizing the incident beam intensity, we have developed a cross-calibrating diagnostic suite that extends the upper limit of measurable peak intensity dynamic range. Absolute intensity calibration is obtained with a 3 {micro}m thick tungsten foil calorimeter and streak spectrometer. We present experimental evidence for peak intensity measures in excess of 400 kW/cm{sup 2} using a 0.3 MV, 25 mA, 5-20 {micro}sec K{sup +1} beam. Radiative models and thermal diffusion effects are discussed because they affect temporal and spatial resolution of beam intensity profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Indirect measurement of molten steel level in tundish based on laser triangulation

For real-time and precise measurement of molten steel level in tundish during continuous casting, slag level and slag thickness are needed. Among which, the problem of slag thickness measurement has been solved in our previous work. In this paper, a systematic solution for slag level measurement based on laser triangulation is proposed. Being different from traditional laser triangulation, several aspects for measuring precision and robustness have been done. First, laser line is adopted for multi-position measurement to overcome the deficiency of single point laser range finder caused by the uneven surface of the slag. Second, the key parameters, such as installing angle and minimum requirement of the laser power, are analyzed and determined based on the gray-body radiation theory to fulfill the rigorous requirement of measurement accuracy. Third, two kinds of severe noises in the acquired images, which are, respectively, caused by heat radiation and Electro-Magnetic Interference (EMI), are cleaned via morphological characteristic of the liquid slag and color difference between EMI and the laser signals, respectively. Fourth, as false target created by stationary slag usually disorders the measurement, valid signals of the slag are distinguished from the false ones to calculate the slag level. Then, molten steel level is obtained by the slag level minus the slag thickness. The measuring error of this solution is verified by the applications in steel plants, which is ±2.5 mm during steady casting and ±3.2 mm at the end of casting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Principles in Remote Sensing of Aerosol from MODIS Over Land and Ocean

The well-calibrated spectral radiances measured by MODIS will be processed to retrieve daily aerosol properties that include optical thickness and mass loading over land and optical thickness, the mean particle size of the dominant mode and the ratio between aerosol modes over ocean. In addition, after launch, aerosol single scattering albedo will be calculated as an experimental product. The retrieval process over land is based on a dark target method that identifies appropriate targets in the mid-IR channels and uses an empirical relationship found between the mid-ER and the visible channels to estimate surface reflectance in the visible from the mid-HZ reflectance measured by satellite. The method employs new aerosol models for industrial, smoke and dust aerosol. The process for retrieving aerosol over the ocean makes use of the wide spectral band from 0.55-2.13 microns and a look-up table constructed from combinations of five accumulation modes and five coarse modes. Both the over land and over ocean algorithms have been validated with satellite and airborne radiance measurements. We estimate that MODIS will be able to measure aerosol optical thickness (t) to within 0.05 +/- 0.2t over land and to within 0.05 +/- 0.05t over ocean. Much of the earth's surface is located far from aerosol sources and experience very low aerosol optical thickness. Will the accuracy expected from MODIS retrievals be sufficient to measure the global aerosol direct and indirect forcing? We are attempting to answer this question using global model results and cloud climatology.

Remer, L. A.↗

Development of a high performance MagLIF target platform using high aspect ratio coated liners and low-mix laser preheat

We report on a series of Magnetized Liner Inertial Fusion (MagLIF) experiments conducted on the Z pulsed power facility that utilized high aspect ratio (ratio of outer radius to wall thickness) liners with dielectric coatings and low-mix laser preheat configurations. The liners consisted of an aspect ratio of 10.6 beryllium tube coated with 75 μm of epoxy on the outside that have been shown to maintain a better implosion stability than uncoated beryllium and have demonstrated consistent stagnation performances in previous experiments [Ampleford et al., Phys. Plasmas 31, 022703 (2024)]. Two-dimensional HYDRA simulations were used to design three different “co-injection” laser configurations, whereby a second laser is used to provide an early prepulse before the main pulse, to reduce LEH foil mix while increasing the fuel density and coupled energy. The laser preheat energy for each configuration was constrained using dedicated laser experiments before being applied to the integrated MagLIF experiments on Z. The DD neutron yield for experiments using co-injection preheat configurations is found to increase with the specific preheat energy in line with simulations. The highest neutron yield achieved in this study of 1.1 × 10 13 matches the highest reported in a MagLIF experiment to date and is a factor 3.5 times higher than similar experiments using preheat with no phase plate smoothing. We attempt to assess the effects of mix and morphology to explain the improved performance; however, neither factor is found to be conclusive within the uncertainty of the measurements.

Harvey-Thompson, A. J.↗

Thermal oscillation smoothing of DT solid layers for HAPL and NIF scale targets

Deuterium-Tritium (D-T) solid fuel layers must meet stringent roughness specifications for both the ICF and IFE laser fusion programs and native beta-layering alone is unable to provide sufficient solid layer smoothing to meet these specifications at 18.3 K or below. Consequently, several supplemental smoothing options have been proposed to resolve this issue, including a technique called 'Thermal Breathing'. This technique consists of oscillating the temperature of the solid D-T layer about its equilibration temperature for a period of one to several hours. Recently, thermal oscillations have been used to successfully smooth rough solid D{sub 2} in spherical targets. In order to study this particular smoothing technique, we examined the effects of thermal oscillations on equilibrated D-T solid layers, using both ICF and IFE scale layering cells and layer thicknesses. The D-T solid layers that were Subjected to thermal breathing in these studies were equilibrated at temperatures ranging from 16.0 K to 19.25 K, followed by 1.5 to 2 hours of temperature oscillations. During the HAPL scale experiments the amplitude and period of the oscillations were both varied to examine parametric effects of these variables on final layer roughness. In both sets of experiments, once the oscillations completed we allowed the layers to 'relax' at their initial equilibration temperature for another 1 to 2 hours, to observe any 'rebounding' or re-roughening that might occur. The rCF scale experiments were performed using a 2 mm beryllium torus, for which the layer was free from optical distortions that were observed in our IFE scale cell (a 4 mm dia. sapphire sphere-cylinder). Our results showed a temperature dependent smoothing effect ofthe DT solid layer ranging from 20% to 35% over the temperature range of 17.3 K to 19.0 K for the rCF-scale, 2-mm celL The final RMS roughness for layers grown in this 2-mm Be torus was on average less than 1 /lm for modes 7 and above. Results for the rFE scale cell showed a temperature dependent smoothing effect that varied from 5% to more than 30% over a 16.0 K to 18.3 K temperature span, and which resulted in an average overall RMS roughness of3.8 /lm at 17.3 K and 3.2 /lm at 18.3 K. We discuss the configuration ofboth of these DT layering cells, the equilibration and oscillation parameters were used, and results that show thermal oscillations can make significant contributions to the smoothing of normally equilibrated beta-layered surfaces, as well as potentially reducing the time required to produce smooth solid DT surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Functionalization of Scanning Probe Tips with Epitaxial Semiconductor Layers

Functionalized scanning probe tips hold great promise for the controlled delivery of signals from and to selected nanoscale volumes. Here, a new nanotechnological approach for the functionalization of scanning probe tips is presented, targeting the transfer of the optical, electrical, thermal, or chemical properties of precisely characterized epitaxial semiconductor layers to the nanoscale probe tip. Homogeneously doped, strain‐relaxed heteroepitaxial germanium layers, several micrometers thick, are first grown on silicon wafers by low‐energy plasma‐enhanced chemical vapor deposition and then employed to functionalize the probe apex. This choice of materials and growth technique enables the future scalability of the tip functionalization process toward high production volumes. The fabricated probe tips are investigated in a transmission electron microscope, revealing that the crystal structure and the homogeneous doping level of the epitaxial layers are unchanged after the probe‐tip functionalization process. These doped‐germanium tips are also tested as nanoemitters of light at telecom wavelengths (1.55 µm) and applied as scattering probes for near‐field mid‐infrared microscopy. The reported combination of heteroepitaxial growth and a nanofabrication approach can be extended to a variety of epitaxial materials, thus enabling a new generation of scanning probes for the investigation of nanostructured materials and devices.

Giliberti, Valeria↗

Reducing Direct Drive Preheat with Dopants

Preheat in laser-driven experiments can have negative impacts on inertial confinement fusion (ICF) and hydrodynamic experiments. While many groups employ the use of dopants to reduce or block preheat, direct quantification has not previously been explored. We developed a planar platform and a series of ablator targets to measure the electron and x-ray spectra generated by laser-plasma interactions with a direct drive using OMEGA-60. By comparing both thin ablators (75 μm) and thick ablators (270 μm) that were either pure CH, 3% Si doped or 3% I doped, we were able to measure differences in electron and x-ray spectra. In addition, we observed the preheat growth of tracer layers and observed reductions in the growth with different materials. We find that iodine or a thin gold layer is the best at tamping the direct-drive preheat at OMEGA, but that the growth is still significant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗