Search NASA⌕ Search

SEARCH · Search NASA

Results for “Waste Form”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Fundamental Radiation Chemistry

An overview presentation for the Fundamental Radiation Chemistry component of the Material Recovery and Waste Form Development campaign to be delivered to the campaign team. The overview includes all major findings from FY19 research projects, current state of FY20 research projects, additional projects completed between FY19 and now, and finally our vision for the future direction of the Fundamental Radiation Chemistry component.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Methods and apparatuses for the development of microstructured nuclear fuels

Microstructured nuclear fuel adapted for nuclear power system use includes fissile material structures of micrometer-scale dimension dispersed in a matrix material. In one method of production, fissile material particles are processed in a chemical vapor deposition (CVD) fluidized-bed reactor including a gas inlet for providing controlled gas flow into a particle coating chamber, a lower bed hot zone region to contain powder, and an upper bed region to enable powder expansion. At least one pneumatic or electric vibrator is operationally coupled to the particle coating chamber for causing vibration of the particle coater to promote uniform powder coating within the particle coater during fuel processing. An exhaust associated with the particle coating chamber and can provide a port for placement and removal of particles and powder. During use of the fuel in a nuclear power reactor, fission products escape from the fissile material structures and come to rest in the matrix material. After a period of use in a nuclear power reactor and subsequent cooling, separation of the fissile material from the matrix containing the embedded fission products will provide an efficient partitioning of the bulk of the fissile material from the fission products. The fissile material can be reused by incorporating it into new microstructured fuel. The fission products and matrix material can be incorporated into a waste form for disposal or processed to separate valuable components from the fission products mixture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Incorporation and Speciation of Sulphur in Glasses for Waste Immobilization

The incorporation and speciation of sulphur in glass compositions relevant to the immobilisation of nuclear and toxic wastes has been investigated; and for the first time we present a detailed analysis of S-bearing phosphate glasses. Sulphur K edge x-ray absorption near edge structure (XANES) has provided detailed information on the oxidation state of sulphur. It confirms that in phosphate glasses prepared under oxidising conditions, sulphur is present as sulphate, SO{sub 4}{sup 2-}. Linear relationships have been identified linking log[SO{sub 3}] (mol%) with the oxygen ion activity, which can be represented by the normalised cation field strength index {Sigma}(z/s{sup 2}). When prepared under oxidising conditions only basic, highly depolymerised phosphate glasses for which {Sigma}(z/a{sup 2})<{approx}1{center_dot}2 can incorporate levels of sulphur that would be considered useful from a waste immobilisation perspective. When glasses are evaluated within familial limits, this methodology provides a useful tool for predicting sulphur capacity and designing new glass compositions that can safely incorporate greater levels of sulphur.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remaining Sites Verification Package for the 100-D-2 Lead Sheeting Waste Site, Waste Site Reclassification Form 2007-030

The 100-D-2 Lead Sheeting waste site was located approximately 50 m southwest of the 185-D Building and approximately 16 m north of the east/west oriented road. The site consisted of a lead sheet covering a concrete pad. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-D-2 Lead Sheeting↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2008-045

The UPR-600-16, Fire and Contamination Spread waste site is an unplanned release that occurred on December 4, 1951, when plutonium contamination was spread by a fire that ignited inside the 120 Experimental Building. The 120 Experimental Building was a laboratory building that was constructed in 1949 and used for plutonium criticality studies as part of the P-11 Project. In November 1951, a criticality occurred in the 120 Experimental Building that resulted in extensive plutonium contamination inside the building. The confirmatory evaluation supports a reclassification of this site to Interim Closed Out. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of the extensive radiological survey of the surface soil and the confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-IU-6 Operable Unit↗

Remaining Sites Verification Package for the 100-B-23, 100-B/C Area Surface Debris, Waste Site, Waste Site Reclassification Form 2008-027

The 100-B-23, 100-B/C Surface Debris, waste consisted of multiple locations of surface debris and chemical stains that were identified during an Orphan Site Evaluation of the 100-B/C Area. Evaluation of the collected information for the surface debris features yielded four generic waste groupings: asbestos-containing material, lead debris, oil and oil filters, and treated wood. Focused verification sampling was performed concurrently with remediation. Site remediation was accomplished by selective removal of the suspect hazardous items and potentially impacted soils. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-B-23 waste site↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2004-065

The 600-111, P-11 Critical Mass Laboratory Crib waste site, also referred to as the P-11 Facility, included the 120 Experimental Building, the 123 Control Building, and the P-11 Crib. The facility was constructed in 1949 and was used as a laboratory for plutonium criticality studies. In accordance with this evaluation, the confirmatory and verification sampling results support a reclassification of this site to Interim Closed Out. The results of confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remaining Sites Verification Package for the 331 Life Sciences Laboratory Drain Field Septic System, Waste Site Reclassification Form 2008-020

The 331 Life Sciences Laboratory Drain Field (LSLDF) septic system waste site consists of a diversion chamber, two septic tanks, a distribution box, and a drain field. This septic system was designed to receive sanitary waste water, from animal studies conducted in the 331-A and 331-B Buildings, for discharge into the soil column. However, field observations and testing suggest the 331 LSLDF septic system did not receive any discharges. In accordance with this evaluation, the confirmatory sampling results support a reclassification of the 331 LSLDF waste site to No Action. This site does not have a deep zone or other condition that would warrant an institutional control in accordance with the 300-FF-2 ROD under the industrial land use scenario.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remaining Sites Verification Package for the 100-B-18, 184-B Powerhouse Debris Pile, Waste Site Reclassification Form 2007-020

The 100-B-18 Powerhouse Debris Pile contained miscellaneous demolition waste from the decommissioning activities of the 184-B Powerhouse. The debris covered an area roughly 15 m by 30 m and included materials such as concrete blocks, mixed aggregate/concrete slabs, stone rubble, asphalt rubble, traces of tar/coal, broken fluorescent lights, brick chimney remnants, and rubber hoses. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-B-18 Powerhouse Debris Pile↗

Identification of lead chemical form in mine waste materials by X-ray absorption spectroscopy

X-ray absorption spectroscopy (XAS) provides a direct means for measuring lead chemical forms in complex samples. In this study, XAS was used to identify the presence of plumbojarosite (PbFe{sub 6}(SO{sub 4}){sub 4}(OH){sub 12}) by lead L{sub 3}-edge XANES spectra in mine waste from a small gold mining operation in Fiji. The presence of plumbojarosite in tailings was confirmed by XRD but XANES gave better resolution. The potential for human uptake of Pb from tailings was measured using a physiologically based extract test (PBET), an in-vitro bioaccessibility (BAc) method. The BAc of Pb was 55%. Particle size distribution of tailings indicated that 40% of PM{sub 10} particulates exist which could be a potential risk for respiratory effects via the inhalation route. Food items collected in the proximity of the mine site had lead concentrations which exceed food standard guidelines. Lead within the mining lease exceeded sediment guidelines. The results from this study are used to investigate exposure pathways via ingestion and inhalation for potential risk exposure pathways of Pb in that locality. The highest Pb concentration in soil and tailings was 25,839 mg/kg, exceeding the Australian National Environment Protection Measure (NEPM) soil health investigation levels.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Savannah River Site Public and Regulatory Involvement in the Inadvertent Disposal of TRU Waste in the E-Area Low-Level Waste (LLW) Trenches

The key to successful public involvement at the Savannah River Site (SRS) has been and continues to be vigorous, up-front involvement of the public, federal and state regulators with technical experts. The SRS Waste Management Program includes all forms of radioactive waste. All of the decisions associated with the management of these wastes are of interest to the public and successful program implementation would be impossible without including the public up-front in the program formulation. Serious problems can result if program decisions are made without public involvement, and if the public is informed after key decisions are made. This paper will describe the regulatory and public involvement program and their effects on the decisions concerning the inadvertent disposal at the Savannah River Site (SRS) of TRU waste in the E-area LLW Facility Trenches. SRS engineers discovered that a small amount of TRU waste was disposed in the E-area LLW trenches in 2003. This discovery was obviously of considerable interest to the State and Federal Regulators, and to the public. In addition to notifications to all interested parties, the first order of business was to ensure that operations continued to be protective of the public and the environment. This paper will describe the interactions with the Department of Energy (DOE), the South Carolina Department of Health and Environmental Control (SCDHEC), the Environmental Protection Agency (EPA), and the public. In addition the technical details of the inadvertent disposal will be discussed along with the analysis of long term performance of the waste form in the E-Area LLW Trenches and how this information was communicated with all parties. As can be imagined, a decision to dispose of TRU waste onsite versus shipment to the Waste Isolation Pilot Plant (WIPP) in New Mexico for disposal is of considerable interest to the stakeholders in South Carolina. The events that lead to the inadvertent disposal will be reviewed as well as the new systems put into place to ensure that this event will not happen again in the future. In order to determine alternatives to properly deposition this TRU waste, an evaluation of retrieval of the waste from the trench disposal was performed as well as an options risk analysis to determine the regulatory path forward should the decision be made to dispose of the TRU waste in place. An evaluation of the risks to the workers associated with retrieval was then compared to the risks of continued disposal in the E-Area Trenches. Cost and schedule for each alternative was also compared. This paper will describe the successful results of this technical, regulatory, and public involvement program, explore the challenges, how the accomplishments occurred, and describe the future challenges along with the road map for the future. A comparison with other similar events at other DOE sites will be discussed as well. In doing this, the SRS TRU and LLW programs must be described to give the readers an understanding of the technical complexities that must be communicated successfully to achieve constructive stakeholder participation and regulatory approval. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remaining Sites Verification Package for the 1607-F1 Sanitary Sewer System (124-F-1) and the 100-F-26:8 (1607-F1) Sanitary Sewer Pipelines Waste Sites, Waste Site Reclassification Form 2004-130

The 1607-F1 Sanitary Sewer System (124-F-1), consisted of a septic tank, drain field, and associated pipelines that received sanitary waste water from the 1701-F Gatehouse, 1709-F Fire Station, and the 1720-F Administrative Office via the 100-F-26:8 pipelines. The septic tank required remedial action based on confirmatory sampling. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-F-26:8 pipelines↗

Remaining Sites Verification Package for the 100-F-46, 119-F Stack Sampling French Drain, Waste Site Reclassification Form 2008-021

The 100-F-46 french drain consisted of a 1.5 to 3 m long, vertically buried, gravel-filled pipe that was approximately 1 m in diameter. Also included in this waste site was a 5 cm cast-iron pipeline that drained condensate from the 119-F Stack Sampling Building into the 100-F-46 french drain. In accordance with this evaluation, the confirmatory sampling results support a reclassification of this site to No Action. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of confirmatory sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-F-46 French Drain↗

Remaining Sites Verification Package for the 100-D-50:5 Process Sewers (183-DR Sedimentation Basin Drains), Waste Site Reclassification Form 2006-025

The 100-D-50:5 subsite encompasses the southern process sewers formerly servicing the 183-DR coagulation and sedimentation basins and proximate surface runoff collection drains. The results of confirmatory sampling of pipeline sediments and underlying soils at the 100-D-50:5 subsite demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-D-50:5 Process Sewers↗

Remaining Sites Verification Package for the 100-F-44:4, Discovery Pipeline in Silica Gel Pit, Waste Site Reclassification Form 2008-030

The 100-F-44:4, Discovery Pipeline in Silica Gel Pit subsite is located in the 100-FR-1 Operable Unit of the Hanford Site, near the location of the former 110-F Gas Storage Tanks structure. The 100-F-44:4 subsite is a steel pipe discovered October 17, 2004, during trenching to locate the 118-F-4 Silica Gel Pit. Based on visual inspection and confirmatory investigation sampling data, the 100-F-44:4 subsite is a piece of non-hazardous electrical conduit debris. The 100-F-44:4 subsite supports unrestricted future use of shallow zone soil and is protective of groundwater and the Columbia River. No residual contamination exists within the deep zone. Therefore, no deep zone institutional controls are required.

100F Area↗

Remaining Sites Verification Package for the 100-F-26:9, 1607-F2 Sanitary Sewer Pipelines, Waste Site Reclassification Form 2008-029

The 100-F-26:9 underground pipeline subsite consists of the sanitary sewers servicing the 105-F, 108-F, 184-F, 185-F, and 190-F buildings, and the 1700-F administration and service buildings (1704-F, 1707-F, 1707-FA, 1713-F, 1717-F, 1719-F, and 1722-F). In accordance with this evaluation, the confirmatory and verification sampling results support a reclassification of this site to Interim Closed Out. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-F-26:9 underground pipeline subsite↗

Chemical characterization of microplastic particles formed in airborne waste discharged from sewer pipe repairs

Microplastic particles are of increasing environmental concern due to the widespread uncontrolled degradation of various commercial products made of plastic and their associated waste disposal. Recently, common technology used to repair sewer pipes was reported as one of the emission sources of airborne microplastics in urban areas. This research presents results of the multi-modal comprehensive chemical characterization of the microplastic particles related to waste discharged in the pipe repair process and compares particle composition with the components of uncured resin and cured plastic composite used in the process. Analysis of these materials employs complementary use of surface-enhanced Raman spectroscopy, scanning transmission X-ray spectro-microscopy, single particle mass spectrometry, and direct analysis in real-time high-resolution mass spectrometry. Further, it is shown that the composition of the relatively large (100 μm) microplastic particles resembles components of plastic material used in the process. In contrast, the composition of the smaller (micrometer and sub-micrometer) particles is significantly different, suggesting their formation from unintended polymerization of water-soluble components occurring in drying droplets of the air-discharged waste. In addition, resin material type influences the composition of released microplastic particles. Results are further discussed to guide the detection and advanced characterization of airborne microplastics in future field and laboratory studies pertaining to sewer pipe repair technology.

54 ENVIRONMENTAL SCIENCES↗

Investigation of Americium-Containing Phosphates, Silicates, Borates, Molybdates, and Fluorides Synthesized via High-Temperature Flux Crystal Growth

The crystal chemistry of americium-containing extended structures was investigated, and several classes of americium-containing solid-state oxide materials were obtained in single-crystal form via high-temperature flux crystal growth. This enabled the structural characterization of rare examples of ternary, quaternary, and penternary americium-containing silicates K 3 Am (Si 2 O 7 ) and Cs 6 Am 2 Si 21 O 48 , phosphates Na 3 Am (PO 4 ) 2 and K 3 Am (PO 4 ) 2 , borates Ba 3 Am 2 (BO 3 ) 4 and AmBO 3 , borate halides Ca 5 Am(BO 3 ) 4 Cl, molybdates Li 0.5 Am 0.5 MoO 4 , and fluorides CsAm 2 F 7 . Using these crystallographic data, the ionic radii of Am 3+ with coordination numbers of six (0.975 Å), seven (1.052 Å), and nine (1.162 Å) were established. A maximum entropy method (MEM) analysis was performed on the single-crystal X-ray diffraction data that were collected for K 3 Nd(PO 4 ) 2 /K 3 Am(PO 4 ) 2 , K 3 NdSi 2 O 7 /K 3 AmSi 2 O 7 , and NdBO 3 /AmBO 3 , to qualitatively compare the ionicities of the Nd–O and Am–O bonds. In conclusion, Raman spectroscopy data were collected on single crystals of K 3 Am(PO 4 ) 2 and compared to the calculated Raman spectrum of K 3 Am(PO 4 ) 2 obtained from DFT calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗