Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Synchronization and Jitter Studies of a Titanium-Sapphire Laser at the A0 Photoinjector

A new titanium-sapphire laser has recently been installed at the A0 photoinjector for use in ongoing beam generation and ultra-fast beam diagnostics experiments. Where the system is used as the photoinjector drive laser, jitter and drift in t he laser pulse time of arrival with respect to the low-level RF master oscillator and other beam components are known to degrade beam performance. These same fluctuations can also impact the temporal resolution of laser-based diagnostics. To resolve this, we present the results of some beam-based timing experiments as well as current progress on a synchronization feedback loop being adapted to the new laser system.

43 PARTICLE ACCELERATORS↗

Photon acceleration of high-intensity vector vortex beams into the extreme ultraviolet

Extreme ultraviolet (XUV) light sources allow for the probing of bound electron dynamics on attosecond scales, interrogation of high-energy-density matter, and access to novel regimes of strong-field quantum electrodynamics. Despite the importance of these applications, coherent XUV sources remain relatively rare, and those that do exist are limited in their peak intensity and spatio-polarization structure. Here, we demonstrate that photon acceleration of an optical vector vortex pulse in the moving density gradient of an electron beam–driven plasma wave can produce a high-intensity, tunable-wavelength XUV pulse with the same vector vortex structure as the original pulse. Quasi-3D, boosted-frame particlein- cell simulations show the transition of optical vector vortex pulses with 800-nm wavelengths and intensities below 10 18 W/cm 2 to XUV vector vortex pulses with 36-nm wavelengths and intensities exceeding 10 20 W/cm 2 over a distance of 1.2 cm. The XUV pulses have sub-femtosecond durations and nearly flat phase fronts. The production of such high-quality, high-intensity XUV vector vortex pulses could expand the utility of XUV light as a diagnostic and driver of novel light–matter interactions.

43 PARTICLE ACCELERATORS↗

Diagnostics, Prognostics, and Optimization for Lithium-Ion Battery Systems

Health management of lithium-ion battery systems presents a host of challenges due to their complex physics, large numbers of components, and a wide variety of degradation behaviors across different battery types. Dr. Paul Gasper will present on research from the Electrochemical Energy Storage Group on Lithium-ion battery diagnostics, prognostics, and optimization. Diagnostics research, including state-estimation via machine-learning from electrochemical impedance spectroscopy and DC pulses as well as continuous state-estimation via Kalman filters, will highlight the ongoing challenges for accurately measuring the state of batteries without performing time-consuming characterization tests. NLR's industry-recognized battery prognostics work, which predicts real-world battery degradation by identifying degradation rate models from accelerated aging data using statistical modeling and machine-learning, will be used to demonstrate the critical impact of battery controls, thermal management, and operating strategy on durability and lifetime. Finally, the use of prognostic models for financial or lifetime optimization will be discussed.

25 ENERGY STORAGE↗

Design and Preliminary Performance Testing of Electronegative Gas Plasma Thruster

In classical gridded electrostatic ion thrusters, positively charged ions are generated from a plasma discharge of noble gas propellant and accelerated to provide thrust. To maintain overall charge balance on the propulsion system, a separate electron source is required to neutralize the ion beam as it exits the thruster. However, if high-electronegativity propellant gases (e.g., sulfur hexafluoride) are instead used, a plasma discharge can result consisting of both positively and negatively charged ions. Extracting such electronegative plasma species for thrust generation (e.g., with time-varying, bipolar ion optics) would eliminate the need for a separate neutralizer cathode subsystem. In addition for thrusters utilizing a RF plasma discharge, further simplification of the ion thruster power system may be possible by also using the RF power supply to bias the ion optics. Recently, the PEGASES (Plasma propulsion with Electronegative gases) thruster prototype successfully demonstrated proof-of-concept operations in alternatively accelerating positively and negatively charged ions from a RF discharge of a mixture of argon and sulfur hexafluoride.i In collaboration with NASA Marshall Space Flight Center (MSFC), the Georgia Institute of Technology High-Power Electric Propulsion Laboratory (HPEPL) is applying the lessons learned from PEGASES design and testing to develop a new thruster prototype. This prototype will incorporate design improvements and undergo gridless operational testing and diagnostics checkout at HPEPL in April 2014. Performance mapping with ion optics will be conducted at NASA MSFC starting in May 2014. The proposed paper discusses the design and preliminary performance testing of this electronegative gas plasma thruster prototype.

Liu, Thomas M.↗

Imaging the End-to-End Dynamics of the Global Solar Wind-Magnetosphere Interaction

Much of what we know about the solar wind’s interaction with the Earth’s magnetosphere has been gained from isolated in situ measurements by single or multiple spacecraft. Based on their observations, we know that reconnection, whether on the dayside magnetopause or deep within the Earth’s magnetotail, controls the flow of solar wind energy into and through the global system. We know that nightside activity provides the energized particles that power geomagnetic storms. But by their very nature these isolated in situ measurements cannot provide an instantaneous global view of the entire system or its cross-scale dynamics. As a result, we don’t know which mode of reconnection prevails on the dayside magnetopause or within the magnetotail as a function of solar wind and geomagnetic conditions. We don’t know which mode or modes of nightside activity supply the most energized particles to the ring current. Nor do we know the dominant loss mode for ring current decay: precipitation, magnetopause outflow, or charge exchange with neutrals. Nor do we know how processes deep within the magnetosphere provide feedback to those happening in the outer magnetosphere. The answers to these questions could have an impact far beyond magnetospheric physics, since magnetic reconnection, particle acceleration, and charge-exchange are fundamental plasma processes that operate at other planets and throughout the universe. Comprehensive end-to-end global imaging of the key micro, meso-, and macro-scale plasma structures that comprise the magnetosphere will provide the answers to these questions via observations with a spatial resolution that exceeds anything possible with in situ measurements. Each proposed interaction mechanism generates a diagnostic plasma structure or boundary signature. Global, end-to-end, imaging provides the pathway to understanding the system as a whole, its constituent parts, and its cross-scale processes on a continuous basis, as needed to quantify the flow of solar wind energy through the global magnetospheric system. The significance of each mechanism is the product of its amplitude and occurrence rate. This white paper describes how a comprehensively-instrumented single spacecraft in a high-latitude circular polar orbit can provide the essential observations needed to track and quantify the flow of solar wind energy through the magnetosphere, including the solar wind plasma and magnetic field input, the magnetopause location in soft X-rays, the auroral oval in far ultraviolet, the ring current in energetic neutrals, the plasmasphere in extreme ultraviolet, the exosphere in Lyman-, the microstructure of the nightside auroral oval in ground-based all sky cameras, and the magnetic perturbations of ionospheric current patterns seen by ground-based magnetometers.

D G Sibeck↗

Beam position monitor gate functionality implementation and applications

We introduce a novel technique to implement gate functionality for the beam position monitors (BPM) at the National Synchrotron Light Source II (NSLS-II). The functionality, now implemented in FPGA, allows us to acquire two separated bunch-trains’ synchronized turn-by-turn (TBT) data simultaneously with the NSLS-II in-house developed BPM system. The gated position resolution is improved about 3 times by narrowing the sampling width. Experimentally we demonstrated that the machine lattice could be transparently characterized with the gated TBT data of a short diagnostic bunch-train Cheng et al., 2017; Li et al., 2017. Other applications, for example, precisely characterizing storage ring impedance/wake-field through recording the beam positions of two separated bunch trains has been experimentally demonstrated.

43 PARTICLE ACCELERATORS↗

Instability limits for spontaneous double layer formation

We present time-resolved measurements that demonstrate that large amplitude electrostatic instabilities appear in pulsed, expanding helicon plasmas at the same time as particularly strong double layers appear in the expansion region. A significant cross-correlation between the electrostatic fluctuations and fluctuations in the number of ions accelerated by the double layer electric field is observed. No correlation is observed between the electrostatic fluctuations and ions that have not passed through the double layer. These measurements confirm that the simultaneous appearance of the electrostatic fluctuations and the double layer is not simple coincidence. In fact, the accelerated ion population is responsible for the growth of the instability. The double layer strength, and therefore, the velocity of the accelerated ions, is limited by the appearance of the electrostatic instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First neutral beam injection experiments on KSTAR tokamak

The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 {mu}P, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8 deg. The ion species ratio is D{sup +}:D{sub 2}{sup +}:D{sub 3}{sup +}= 75:20:5 at beam current density of 85 mA/cm{sup 2}. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the T{sub i} and T{sub e} profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.

43 PARTICLE ACCELERATORS↗

Kilovoltage energy imaging with a radiotherapy linac with a continuously variable energy range

Purpose: In this paper, the effect on image quality of significantly reducing the primary electron energy of a radiotherapy accelerator is investigated using a novel waveguide test piece. The waveguide contains a novel variable coupling device (rotovane), allowing for a wide continuously variable energy range of between 1.4 and 9 MeV suitable for both imaging and therapy.Method: Imaging at linac accelerating potentials close to 1 MV was investigated experimentally and via Monte Carlo simulations. An imaging beam line was designed, and planar and cone beam computed tomography images were obtained to enable qualitative and quantitative comparisons with kilovoltage and megavoltage imaging systems. The imaging beam had an electron energy of 1.4 MeV, which was incident on a water cooled electron window consisting of stainless steel, a 5 mm carbon electron absorber and 2.5 mm aluminium filtration. Images were acquired with an amorphous silicon detector sensitive to diagnostic x-ray energies. Results: The x-ray beam had an average energy of 220 keV and half value layer of 5.9 mm of copper. Cone beam CT images with the same contrast to noise ratio as a gantry mounted kilovoltage imaging system were obtained with doses as low as 2 cGy. This dose is equivalent to a single 6 MV portal image. While 12 times higher than a 100 kVp CBCT system (Elekta XVI), this dose is 140 times lower than a 6 MV cone beam imaging system and 6 times lower than previously published LowZ imaging beams operating at higher (4-5 MeV) energies. Conclusions: The novel coupling device provides for a wide range of electron energies that are suitable for kilovoltage quality imaging and therapy. The imaging system provides high contrast images from the therapy portal at low dose, approaching that of gantry mounted kilovoltage x-ray systems. Additionally, the system provides low dose imaging directly from the therapy portal, potentially allowing for target tracking during radiotherapy treatment. There is the scope with such a tuneable system for further energy reduction and subsequent improvement in image quality.

43 PARTICLE ACCELERATORS↗

2-20 ns interframe time 2-frame 6.151 keV x-ray imaging on the recently upgraded Z Accelerator: A progress report

When used for the production of an x-ray imaging backlighter source on Sandia National Laboratories' recently upgraded 26 MA Z Accelerator, the terawatt-class, multikilojoule, 526.57 nm Z-Beamlet laser (ZBL) [P. K. Rambo et al., Appl. Opt. 44, 2421 (2005)], in conjunction with the 6.151 keV (1s{sup 2}-1s2p triplet line of He-like Mn) curved-crystal imager [D. B. Sinars et al., Rev. Sci. Instrum. 75, 3672 (2004); G. R. Bennett et al., Rev. Sci. Instrum. 77, 10E322 (2006)], is capable of providing a high quality x radiograph per Z shot for inertial confinement fusion (ICF), complex hydrodynamics, and other high-energy-density physics experiments. For example, this diagnostic has recently afforded microgram-scale mass perturbation measurements on an imploding ignition-scale 1 mg ICF capsule [G. R. Bennett et al., Phys. Rev. Lett. 99, 205003 (2007)], where the perturbation was initiated by a surrogate deuterium-tritium (DT) fuel fill tube. Using an angle-time multiplexing technique, ZBL now has the capability to provide two spatially and temporally separated foci in the Z chamber, allowing 'two-frame' imaging to be performed, with an interframe time range of 2-20 ns. This multiplexing technique allows the full area of the four-pass amplifiers to be used for the two pulses, rather than split the amplifiers effectively into two rectangular sections, with one leg delayed with respect to the other, which would otherwise double the power imposed onto the various optics thereby halving the damage threshold, for the same irradiance on target. The 6.151 keV two frame technique has recently been used to image imploding wire arrays, using a 7.3 ns interframe time. The diagnostic will soon be converted to operate with p-rather than s-polarized laser light for enhanced laser absorption in the Mn foil, plus other changes (e.g., operation at the possibly brighter 6.181 keV Mn 1s{sup 2}-1s2p singlet line), to increase x-ray yields. Also, a highly sensitive inline multiframe ultrafast (1 ns gate time) digital x-ray camera is being developed [G. R. Bennett et al., Rev. Sci. Instrum. 77, 10E322 (2006)] to extend the system to 'four-frame' and markedly improve the signal-to-noise ratio. [At present, time-integrating Fuji BAS-TR2025 image plate (scanned with a Fuji BAS-5000 device) forms the time-integrated image-plane detector.].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam correction for multi-pass arcs in FFA@CEBAF: status update

This work examines the multi-pass steering of six electron beams in an FFA arc ranging from approximately 10.5 GeV to 22 GeV. Shown here is an algorithm based on singular value decomposition (SVD) to successfully steer all six beams through the arc given precise knowledge of all beam positions at each of one hundred and one diagnostic locations with one hundred individual corrector magnets: that is successive application of SVD to different 100 × 101 response matrices—one for each beam energy. Further, a machine learning scheme is developed which only requires knowledge of the energy-averaged beam position at each location to provide equivalent steering. Extension of this scheme to other beam optics quantities as well as transverse and longitudinal coupling is explored.

Accelerator Physics↗

Measurement of DT and DD components in neutron spectrum with a double-crystal time-of-flight spectrometer

To investigate the deuteron and triton density ratio in core plasmas, a new methodology with measurement of tritium (DT) and deuterium (DD) neutron count rate ratio using a double-crystal time-of-flight (TOF) spectrometer is proposed. Multi-discriminator electronic circuits for the first and second detectors are used in addition to the TOF technique. The optimum arrangement of the detectors and discrimination window were examined considering the relations between the geometrical arrangement and deposited energy using a Monte Carlo Code, PHITS (Particle and Heavy Ion Transport Code System). An experiment to verify the calculations was performed using DD neutrons from an accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic profile prediction and validation of a negative triangularity plasma in ASDEX Upgrade

In this work, gyrokinetic simulations are performed with the CGYRO code (Candy et al 2016 J. Comput. Phys. 324 73–93) for a negative triangularity H-mode plasma in ASDEX Upgrade, and compared with experimental measurements. The PORTALS framework (Rodriguez-Fernandez et al 2024 Nucl. Fusion 64 076034) is used to accelerate the prediction of kinetic profiles for this plasma, using surrogate modeling and Bayesian optimization. Ion heat flux, electron heat flux, and electron particle flux are simultaneously matched across the simulated radial regime of the plasma (normalized radius $r/a = 0.35-0.90$), and the resulting ion temperature, electron temperature, and electron density profiles match well with the experimental profile data within this radial range. A synthetic Correlation Electron Cyclotron Emission diagnostic is applied to find well-matched electron temperature fluctuation properties between simulation and experiment. The flux-matched profiles provide a basis for investigation of the turbulence nature across the plasma radius, revealing the dominance of Trapped Electron Mode turbulence at $r/a = 0.35$, the dominance of Ion Temperature Gradient turbulence at $r/a = 0.55$, 0.75, and 0.83, and an instability boundary at $r/a = 0.90$.

gyrokinetic simulation↗

Experimental Study of a Single Electron in a Storage Ring via Undulator Radiation

A single electron orbiting around a ring and emitting single quanta at the rate of about one event per hundred turns could produce a wealth of information about physical processes in large traps (i.e. storage rings) for charged particles. It should be noted that Paul and Penning traps in the 1980s led to the Nobel prize for studying state and motion of single quantum particles, and just recently the Penning trap technique has enabled the measurement of a single proton magnetic moment with an unprecedented precision of 10 decimal places. The information from the storage ring traps could also be used for characterization of a quantum system as well as the "trap" itself, i.e. measuring properties of the storage ring lattice and electron interaction with the laser fields. Although, the interest in single electron quantum processes today is mostly academic in nature, the diagnostics and methodology developed for single electron radiation studies could find subsequent applications in a variety of applied disciplines in quantum technology, including quantum communications and quantum computing.

43 PARTICLE ACCELERATORS↗

The Connection between the Presence of Melanoma and Changes in Fibre Diffraction Patterns

An accurate diagnosis of melanomas at an early stage correlates directly with a better prognosis. However the incidence of melanoma is still increasing along with the number of related deaths. Melanoma cells grow extremely fast, with the result that many patients present after metastasis has occurred, too late for effective treatment. This paper describes the changes in the fibre diffraction patterns of skin that indicate the presence of a melanoma. Identification of these changes would provide an alternative early low-cost, reliable diagnostic test which could be conducted on a regular basis in local radiology facilities using rotating anode X-ray generators or as a mass screening test using suitable small angle x-ray beam-lines at synchrotrons.

43 PARTICLE ACCELERATORS↗

The Side Plume of Magnetically Shielded Hall Thrusters

A combination of near-thruster laser-induced fluorescence and far-field plasma probe measurements collected from two magnetically shielded Hall thrusters have shown that there exist an independent ion population of medium-energy (on average, 60-190 eV) exiting out the side (60° to 100° from firing axis) of the thrusters. Studying the trends with background pressure and known discrepancies between the laser-induced fluorescence and far-field plasma probe data suggest that at zero pressure the side plume is likely to exhibit higher energy and lower density than at facility background pressures. The possibility that these ions were produced by the modified two-stream instability is explored and while the agreement is good, there are areas of notable disagreement. Based on the idea that production of the side plume and channel exit striations are due to the same plasma wave actions, a theory was explored that explains why striations form under certain circumstances but not others. Another theory, based on the idea that side plume production only occurs over certain portion of the global discharge oscillation cycle, was also explored and areas of disagreement were identified. While the exact mechanism for side plume acceleration remains unclear, if the theory behind side plume production is correct, then side plume can be expected to be present in a wide range of magnetically-shielded as well as non-shielded Hall thrusters.

Hall thruster↗

The Side Plume of Magnetically Shielded Hall Thrusters

A combination of near-thruster laser-induced fluorescence and far-field plasma probe measurements collected from two magnetically shielded Hall thrusters have shown that there exist an independent ion population of medium-energy (on average, 60-190 eV) exiting out the side (60° to 100° from firing axis) of the thrusters. Studying the trends with background pressure and known discrepancies between the laser-induced fluorescence and far-field plasma probe data suggest that at zero pressure the side plume is likely to exhibit higher energy and lower density than at facility background pressures. The possibility that these ions were produced by the modified two-stream instability is explored and while the agreement is good, there are areas of notable disagreement. Based on the idea that production of the side plume and channel exit striations are due to the same plasma wave actions, a theory was explored that explains why striations form under certain circumstances but not others. Another theory, based on the idea that side plume production only occurs over certain portion of the global discharge oscillation cycle, was also explored and areas of disagreement were identified. While the exact mechanism for side plume acceleration remains unclear, if the theory behind side plume production is correct, then side plume can be expected to be present in a wide range of magnetically-shielded as well as non-shielded Hall thrusters.

Electric propulsion↗

Absolute Neutron Emission Measurement in Burning Plasma Experiments

The absolute measurement of neutron emission rate from the whole plasma is a very important diagnostics as a fusion power monitor in fusion experimental devices with D-T or D-T operations. Here measurement techniques of time-resolved and time-integrated absolute neutron emission on the present tokamaks and ITER are reviewed. In the present tokamaks, fission chamber installed outside the vacuum vessel are very popular in the absolute neutron emission rate measurement. As well as conventional neutron monitors installed outside the vacuum vessel, in-vessel neutron monitors using micro fission chamber are proposed for the absolute neutron emission rate measurement in ITER. The neutron activation system provides time-integrated measurements of the total neutron yield with high accuracy by using well known neutron reaction cross sections, which is useful to maintain a robust measure of fusion energy production with stability and wide dynamic range. The calibration of the relation between the neutron emission rate in the whole plasma and the output of neutron monitor is the most important issue in the absolute neutron emission rate measurements. The calibration of the neutron detectors has been performed by moving a neutron source such as a {sup 252}Cf neutron or a small accelerator-based neutron generator. For the calibration in ITER, the neutron generator with neutron emission rate of 10{sup 11} s{sup -1} or stronger is required to obtain high accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗