Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Noncoplanar Beam Angle Class Solutions to Replace Time-Consuming Patient-Specific Beam Angle Optimization in Robotic Prostate Stereotactic Body Radiation Therapy

Purpose: To investigate development of a recipe for the creation of a beam angle class solution (CS) for noncoplanar prostate stereotactic body radiation therapy to replace time-consuming individualized beam angle selection (iBAS) without significant loss in plan quality, using the in-house “Erasmus-iCycle” optimizer for fully automated beam profile optimization and iBAS. Methods and Materials: For 30 patients, Erasmus-iCycle was first used to generate 15-, 20-, and 25-beam iBAS plans for a CyberKnife equipped with a multileaf collimator. With these plans, 6 recipes for creation of beam angle CSs were investigated. Plans of 10 patients were used to create CSs based on the recipes, and the other 20 to independently test them. For these tests, Erasmus-iCycle was also used to generate intensity modulated radiation therapy plans for the fixed CS beam setups. Results: Of the tested recipes for CS creation, only 1 resulted in 15-, 20-, and 25-beam noncoplanar CSs without plan deterioration compared with iBAS. For the patient group, mean differences in rectum D{sub 1cc}, V{sub 60GyEq}, V{sub 40GyEq}, and D{sub mean} between 25-beam CS plans and 25-beam plans generated with iBAS were 0.2 ± 0.4 Gy, 0.1% ± 0.2%, 0.2% ± 0.3%, and 0.1 ± 0.2 Gy, respectively. Differences between 15- and 20-beam CS and iBAS plans were also negligible. Plan quality for CS plans relative to iBAS plans was also preserved when narrower planning target volume margins were arranged and when planning target volume dose inhomogeneity was decreased. Using a CS instead of iBAS reduced the computation time by a factor of 14 to 25, mainly depending on beam number, without loss in plan quality. Conclusions: A recipe for creation of robust beam angle CSs for robotic prostate stereotactic body radiation therapy has been developed. Compared with iBAS, computation times decreased by a factor 14 to 25. The use of a CS may avoid long planning times without losses in plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Much Does Lead Shielding during Fluoroscopy Reduce Radiation Dose to Out-of-Field Body Parts?

Fluoroscopy technologists routinely place a lead shield between the x-ray table and the patient's gonads, even if the gonads are not directly in the x-ray field. Internal scatter radiation is the greatest source of radiation to out-of-field body parts, but a shield placed between the patient and the x-ray source will not block internal scatter. Prior nonfluoroscopy research has shown that there is a small reduction in radiation dose when shielding the leakage radiation that penetrates through the collimator shutters. The goal of this in vitro study was to determine if there was any radiation dose reduction when shielding leakage radiation during fluoroscopy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Direct Aperture Optimization When Applied to Head-And-Neck IMRT

Direct Machine Parameter Optimization (DMPO) is a leaf segmentation program released as an optional item of the Pinnacle planning system (Philips Radiation Oncology Systems, Milpitas, CA); it is based on the principles of direct aperture optimization where the size, shape, and weight of individual segments are optimized to produce an intensity modulated radiation treatment (IMRT) plan. In this study, we compare DMPO to the traditional method of IMRT planning, in which intensity maps are optimized prior to conversion into deliverable multileaf collimator (MLC) apertures, and we determine if there was any dosimetric improvement, treatment efficiency gain, or planning advantage provided by the use of DMPO. Eleven head-and-neck patients treated with IMRT had treatment plans generated using each optimization method. For each patient, the same planning parameters were used for each optimization method. All calculations were performed using Pinnacle version 7.6c software and treatments were delivered using a step-and-shoot IMRT method on a Varian 2100EX linear accelerator equipped with a 120-leaf Millennium MLC (Varian Medical Systems, Palo Alto, CA). Each plan was assessed based on the calculation time, a conformity index, the composite objective value used in the optimization, the number of segments, monitor units (MUs), and treatment time. The results showed DMPO to be superior to the traditional optimization method in all areas. Considerable advantages were observed in the dosimetric quality of DMPO plans, which also required 32% less time to calculate, 42% fewer MUs, and 35% fewer segments than the conventional optimization method. These reductions translated directly into a 29% decrease in treatment times. While considerable gains were observed in planning and treatment efficiency, they were specific to our institution, and the impact of direct aperture optimization on plan quality and workflow will be dependent on the planning parameters, planning system, and linear accelerators used by a particular institution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comprehensive clinical 3-dimensional dosimetric analysis of forward planned IMRT and conventional wedge planned techniques for intact breast radiotherapy

A forward planned intensity modulated technique was initiated for intact breasts radiotherapy (FPIMRT). Forty-three patients were selected to compare dose distributions achieved by FPIMRT to dose distributions produced by conventional wedge techniques (CW). For the simulation process, the treatment field margins were clinically defined by a physician, and a set of fiducial reference markers was placed on the patient. A computed tomography (CT) scan was then performed and the images were transferred to a 3-dimensional (3D) treatment planning system (TPS). The breast tissue was then contoured to allow for a quantitative dose volume analysis. The treatment plan was initially generated with conventional tangential beam arrangements and open fields. Multiple multileaf collimator (MLC) shaped segments were created for each tangential beam in an effort to produce dose homogeneity throughout the breast. 6-MV photon beams were used for treatment unless acceptable dose homogeneity could not be achieved due to large breast size. In this case, the beam energies of selected segments were modified to 15-MV. Once the FPIMRT plan was created, additional plans were generated using the same beam geometry and 2 tangential open fields with CW techniques and 15 deg. wedges (15DW), 30 deg. wedges (30DW), 45 deg. wedges (45 DW), and 60 deg. wedges (60DW). The dose distributions generated by the CW plans were then compared to the FPIMRT plan. This process was repeated for each patient, and the patient group was divided into 3 categories based on breast volume (small, medium, and large). Both point dose relationships, which compared global hot spot (GHS) magnitude and location and dose volume relationships, which compared breast volume coverage of the 105% and 110% isodose lines (IDL) relative to the prescribed dose (PD), were explored. For the patient group in our study, FPIMRT produced the smallest average GHS and the most evenly distributed location of GHS for all breast size categories when compared to all CW techniques. FPIMRT also produced the smallest average breast volume receiving greater than 105% of the PD (V{sub a105}) for the small- and medium-size breast patients and the smallest average breast volume receiving greater than 110% of the PD (V{sub a110}) for all breast size categories when compared to all CW techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of MLC Leaf Width and PTV Margin on the Treatment Planning of Intensity-Modulated Stereotactic Radiosurgery (IMSRS) or Radiotherapy (IMSRT)

We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices - D{sub mean} (mean dose), conformity index (CI), V{sub 70} (volume receiving {>=} 70% of the prescription dose), and V{sub 50} (volume receiving {>=} 50% of the prescription dose) - were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D{sub 95}, V{sub 95}, D{sub max}, D{sub min}, and D{sub mean} of the PTV. The irradiated volume was {approx}23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by {approx}6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V{sub 70}, V{sub 50}, and D{sub mean} were reduced more effectively by a decrease in MLC width, while D{sub mean} of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Case Report on the Effect of Fan Beam Thickness in Helical Tomotherapy of Nasopharyngeal Carcinoma

The fan beam thickness (FBT) in helical tomotherapy is defined by a pair of collimators parallel to the rotational orbit of the radiation beam and is fixed for a specific patient treatment. The aim of this case study is to evaluate the dosimetric influence of changing the FBT in the treatment of a nasopharyngeal carcinoma (NPC) patient. The subject was a T2N1M0 stage NPC patient. The planning target volumes (PTVs) of the primary nasopharyngeal tumor and the left and right cervical lymphatics were delineated along with the organs at risk (OARs) in the corresponding computed tomography slices. Three treatment plans with FBT of 1.0 cm, 2.5 cm, and 5.0 cm (FBT-10, FBT-25, and FBT-50) were generated separately based on similar dose constraints and planning parameters. The dosimetric results of the PTV and OARs were collected and compared among the 3 treatment plans. The differences in the dose parameters of the PTVs were small among the 3 plans. The FBT-10 plan demonstrated the most homogeneous PTV doses with the smallest homogeneity indices (HIs). The FBT-50 plan delivered the highest dose to the OARs and the FBT-10 plan delivered the lowest. The differences between the 2 plans were more significant in the spinal cord, optic chiasm, optic nerves, and lens. This case study demonstrated that the variation of FBT in tomotherapy affected the quality of the treatment plan mainly in the OAR doses, but not so much in the PTV. Increasing the FBT reduced the effectiveness in the sparing of OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dosimetric Analysis of IMRT and Multistatic Fields Techniques for Left Breast Radiotherapy

The purpose of this study was to analyze the dosimetric difference between intensity-modulated radiation therapy (IMRT) using 3 or 5 beams and multistatic field technique (MSF) in radiotherapy of the left breast. We made comparative analysis of two kinds of radiotherapy that can achieve improved dose homogeneity. First is a MSF that uses both major and small irradiation fields at the same time. The other is IMRT using 3 or 5 beams with an inverse planning system using multiple static multileaf collimators. We made treatment plans for 16 early left breast cancer patients who were randomly selected and had undergone breast conserving surgery and radiotherapy, and analyzed them in the dosimetric aspect. For the mean values of V{sub 95} and dose homogeneity index, no statistically significant difference was observed among the three therapies. Extreme hot spots receiving >110% of prescribed dose were not found in any of the three methods. Using Tukey's test, IMRT showed a significantly larger increase in exposure dose to the ipsilateral lung and the heart than MSF in the low-dose area, but in the high-dose area, MSF showed a slight increase. To improve dose homogeneity, the application of MSF, which can be easily planned and applied more widely, is considered optimal as an alternative to IMRT for radiotherapy of early left breast cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Conventional Craniospinal Irradiation with Patient Supine and Source-Skin Distance (SSD) 100 cm for Spinal Field

We describe a method of craniospinal irradiation (CSI) in the supine position and at a source-skin distance (SSD) of 100 cm for the spinal fields. The procedure is carried out with a 100-cm isocenter linear accelerator and conventional simulator, and the treatment is delivered with 2 opposed lateral cranial fields at source-axis distance (SAD) of 100 cm and 1 or 2 direct posterior spinal fields at SSD, 100 cm. The half beam-blocked cranial fields with a collimator rotation is used to match the superior border of the spinal field at the level of C2 vertebral body. The length of the spinal field is fixed, and is the same if 2 spinal fields are used. The position of the isocenter of the spine field is defined by longitudinally moving the couch a distance from the isocenter of the cranial fields and adjusting the SSD = 100 cm to the surface of the couch with the gantry rotated to the angle of 180 Degree-Sign (posteroanterior position), and the distance can be calculated easily according to a few parameters. It only needs a simple calculation without couch rotation, extended SSD, or markers. The inferior and superior borders of the spinal field do not require visualization under fluoroscopy when it is beyond the visual field of the simulator. The entire simulation takes no more than 20 minutes. Supine craniospinal treatment using this technique may substitute the traditional prone position as a potentially beneficial alternative to CSI.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improved Treatment of the Breast and Supraclavicular Fossa Based on a Simple Geometrical Principle

In breast cancer, nodal irradiation has become routine, but adds time and creates concerns for field overlap if the 'match' is not accurate. We developed a technique to address these issues by using only one isocenter for both areas. Tangents are designed at simulation. The isocenter is then shifted to the upper border of the breast using a straightforward geometrical calculation. After determining the new isocenter, fields are recreated wherein the tangents are treated with a quarter beam and the supraclavicular field fashioned with a half-beam block. The gantry, collimator, and couch angles of the supraclavicular field are adjusted to achieve an accurate match. Ten patients were evaluated. Doses to the spinal cord and brachial plexus were lowered relative to conventional techniques. The hot spots were not augmented. In comparison with standard arrangements, setup time decreased. Accurate matching was consistently achieved and verified by portal imaging. A new approach for treating the supraclavicular fossa is easily executed. Advantages include negligible doses to the critical neural structures (i.e., spinal cord and brachial plexus), optimized matchline, and reduced setup time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of MLC leaf width on the quality of the dose distribution in partial breast irradiation

Partial-breast irradiation (PBI) aims to limit the target volume for radiotherapy in women with early breast cancer after partial mastectomy to the region at highest risk of local recurrence, the tumor bed. Multileaf collimators are used to achieve conformal radiation beam portals required for PBI. Narrower leaf widths are generally assumed to allow more conformal shaping of beam portals around irregularly shaped target volumes. The aim was to compare 5-mm and 10-mm leaf widths for patients previously treated using PBI and assess subsequent planning target volume (PTV) coverage and organ at risk (OAR) doses for 16 patients. Several plans (5-mm leaf width or 10-mm leaf width) were generated for each patient using the original treated plan as the basis for attempts at further optimization. Alternating between different leaf widths found no significant difference in terms of overall PTV coverage and OAR doses between treatment plans. Optimization of the original treated plan allowed a small decrease in ipsilateral breast dose, which was offset by a lower PTV minimum. No significant dosimetric difference was found to support an advantage of 5-mm over 10-mm leaf width in this setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simplified field-in-field technique for a large-scale implementation in breast radiation treatment

We wanted to evaluate a simplified 'field-in-field' technique (SFF) that was implemented in our department of Radiation Oncology for breast treatment. This study evaluated 15 consecutive patients treated with a simplified field in field technique after breast-conserving surgery for early-stage breast cancer. Radiotherapy consisted of whole-breast irradiation to the total dose of 50 Gy in 25 fractions, and a boost of 16 Gy in 8 fractions to the tumor bed. We compared dosimetric outcomes of SFF to state-of-the-art electronic surface compensation (ESC) with dynamic leaves. An analysis of early skin toxicity of a population of 15 patients was performed. The median volume receiving at least 95% of the prescribed dose was 763 mL (range, 347-1472) for SFF vs. 779 mL (range, 349-1494) for ESC. The median residual 107% isodose was 0.1 mL (range, 0-63) for SFF and 1.9 mL (range, 0-57) for ESC. Monitor units were on average 25% higher in ESC plans compared with SFF. No patient treated with SFF had acute side effects superior to grade 1-NCI scale. SFF created homogenous 3D dose distributions equivalent to electronic surface compensation with dynamic leaves. It allowed the integration of a forward planned concomitant tumor bed boost as an additional multileaf collimator subfield of the tangential fields. Compared with electronic surface compensation with dynamic leaves, shorter treatment times allowed better radiation protection to the patient. Low-grade acute toxicity evaluated weekly during treatment and 2 months after treatment completion justified the pursuit of this technique for all breast patients in our department.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

61 RADIATION PROTECTION AND DOSIMETRY↗

IMRT treatment of anal cancer with a scrotal shield

The risk of sterility in males undergoing radiotherapy in the pelvic region indicates the use of a shielding device, which offers protection to the testes for patients wishing to maintain fertility. The use of such devices in the realm of intensity-modulated radiotherapy (IMRT) in the pelvic region can pose many obstacles during simulation, treatment planning, and delivery of radiotherapy. This work focuses on the development and execution of an IMRT plan for the treatment of anal cancer using a scrotal shielding device on a clinical patient. An IMRT plan was developed using Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA), using a wide array of gantry angles as well as fixed jaw and fluence editing techniques. When possible, the entire target volume was encompassed by the treatment field. When the beam was incident on the scrotal shield, the jaw was fixed to avoid the device and the collimator rotation optimized to irradiate as much of the target as possible. This technique maximizes genital sparing and allows minimal irradiation of the gonads. When this fixed-jaw technique was found to compromise adequate coverage of the target, manual fluence editing techniques were used to avoid the shielding device. Special procedures for simulation, imaging, and treatment verification were also developed. In vivo dosimetry was used to verify and ensure acceptable dose to the gonads. The combination of these techniques resulted in a highly conformal plan that spares organs and risk and avoids the genitals as well as entrance of primary radiation onto the shielding device.

61 RADIATION PROTECTION AND DOSIMETRY↗

An overview of craniospinal axis fields and field matching

Many methods are implemented for craniospinal axis (CSA) radiation treatment (RT). This paper’s goal is to define correctly matched CSA RT fields. Overlap or a space between matched RT fields can create variances of dose and the possibility of negative side effects or disease recurrence, respectively. An accurate CSA RT match procedure is created with localization markers, immobilization devices, equations, feathered matches, safety gap, and portal imaging. A CS match angle is predetermined to optimize patient position before immobilization device fabrication. Various central axis (CA) placements within the brain and spine fields that effect gantry, table, and collimator rotation are described. An overview of the methods used to create CSA RT fields and matches is presented for optimal CSA RT implementation. In addition, to the author’s knowledge, this is the first time that a prone CSA RT with anesthesia has been described.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric effect of Elekta Beam Modulator micromultileaf in three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer

The purpose of this study is to analyze the dosimetric effect of Elekta Beam Modulator in 3-dimensional conformal radiation therapy (3DCRT) and in intensity-modulated radiation therapy (IMRT) for localized prostate cancer. We compared treatment plans developed with 2 different Elekta multileaf collimators (MLC): Beam Modulator micro-MLC (mMLC) (4-mm leaf width at the isocenter) and standard MLC (10-mm leaf width at the isocenter). The comparison was performed for 15 patients with localized prostate cancer in 3DCRT and IMRT delivery; a total of 60 treatment plans were processed. The dose-volume histograms were used to provide the quantitative comparison between plans. In particular, we analyzed differences between rectum and bladder sparing in terms of a set of appropriate Vx (percentage of organ at risk [OAR] volume receiving the x dose) and differences between target conformity and coverage in terms of coverage factor and conformation number. Our analysis demonstrates that in 3DCRT there is an advantage in the use of Elekta Beam Modulator mMLC in terms of organ sparing; in particular, a significant decrease in rectal V{sub 60} and V{sub 50} (p = 0.001) and in bladder V{sub 70} and V{sub 65} (p = 0.007 and 0.002, respectively) was found. Moreover, a better target dose conformity was obtained (p = 0.002). IMRT plans comparison demonstrated no significant differences between the use of the 4 or 10-mm MLCs. Our analysis shows that in 3DCRT the use of the Elekta Beam Modulator mMLC gives a gain in target conformity and in OARs dose sparing whereas in IMRT plans there is no advantage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advantages and limitations of navigation-based multicriteria optimization (MCO) for localized prostate cancer IMRT planning

Efficacy of inverse planning is becoming increasingly important for advanced radiotherapy techniques. This study’s aims were to validate multicriteria optimization (MCO) in RayStation (v2.4, RaySearch Laboratories, Sweden) against standard intensity-modulated radiation therapy (IMRT) optimization in Oncentra (v4.1, Nucletron BV, the Netherlands) and characterize dose differences due to conversion of navigated MCO plans into deliverable multileaf collimator apertures. Step-and-shoot IMRT plans were created for 10 patients with localized prostate cancer using both standard optimization and MCO. Acceptable standard IMRT plans with minimal average rectal dose were chosen for comparison with deliverable MCO plans. The trade-off was, for the MCO plans, managed through a user interface that permits continuous navigation between fluence-based plans. Navigated MCO plans were made deliverable at incremental steps along a trajectory between maximal target homogeneity and maximal rectal sparing. Dosimetric differences between navigated and deliverable MCO plans were also quantified. MCO plans, chosen as acceptable under navigated and deliverable conditions resulted in similar rectal sparing compared with standard optimization (33.7 ± 1.8 Gy vs 35.5 ± 4.2 Gy, p = 0.117). The dose differences between navigated and deliverable MCO plans increased as higher priority was placed on rectal avoidance. If the best possible deliverable MCO was chosen, a significant reduction in rectal dose was observed in comparison with standard optimization (30.6 ± 1.4 Gy vs 35.5 ± 4.2 Gy, p = 0.047). Improvements were, however, to some extent, at the expense of less conformal dose distributions, which resulted in significantly higher doses to the bladder for 2 of the 3 tolerance levels. In conclusion, similar IMRT plans can be created for patients with prostate cancer using MCO compared with standard optimization. Limitations exist within MCO regarding conversion of navigated plans to deliverable apertures, particularly for plans that emphasize avoidance of critical structures. Minimizing these differences would result in better quality treatments for patients with prostate cancer who were treated with radiotherapy using MCO plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the HT, IMRT, and CRT modalities are 64.0, 60.9, and 60.8 Gy, respectively. Regarding the risk for secondary cancer, for the heart, the lowest average risk is produced by IMRT (0.10%) compared with the HT (0.17%) and CRT (0.12%) modalities, whereas the 3 radiation modalities show almost equivalent results regarding the contralateral lung (0.8% for HT, 0.9% for IMRT, and 0.9% for CRT). The use of radiobiologic parameters in the evaluation of different treatment plans and estimation of their expected clinical outcome is shown to provide very useful clinical information. The radiobiologic analysis of the response probabilities showed that different radiation modalities appear to be more effective in different patient geometries and target sizes and locations. Furthermore, there is not a clear pattern between the plans that appear to be more effective for the treatment and the risk of secondary malignancy. It seems that radiobiologically based treatment planning taking into account the risk of secondary cancer can be established as an effective clinical tool for a more clinically relevant treatment optimization.

61 RADIATION PROTECTION AND DOSIMETRY↗