Search NASA⌕ Search

SEARCH · Search NASA

Results for “dimensional”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Transition probabilities for non self-adjoint Hamiltonians in infinite dimensional Hilbert spaces

In a recent paper we have introduced several possible inequivalent descriptions of the dynamics and of the transition probabilities of a quantum system when its Hamiltonian is not self-adjoint. Our analysis was carried out in finite dimensional Hilbert spaces. This is useful, but quite restrictive since many physically relevant quantum systems live in infinite dimensional Hilbert spaces. In this paper we consider this situation, and we discuss some applications to well known models, introduced in the literature in recent years: the extended harmonic oscillator, the Swanson model and a generalized version of the Landau levels Hamiltonian. Not surprisingly we will find new interesting features not previously found in finite dimensional Hilbert spaces, useful for a deeper comprehension of this kind of physical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of two-dimensional materials on human mesenchymal stem cell behaviors

Graphene, a typical two-dimensional (2D) material, is known to affect a variety of stem cell behaviors including adhesion, spreading, growth, and differentiation. Here, we report for the first time the effects of four different emerging 2D materials on human adipose-derived mesenchymal stem cells (hADMSCs). Graphene oxide (GO), molybdenum sulfide (MoS{sub 2}), tungsten sulfide (WS{sub 2}), and boron nitride (BN) were selected as model two-dimensional materials and were coated on cell-culture substrates by a drop-casting method. Acute toxicity was not observed with any of the four different 2D materials at a low concentration range (<5 μg/ml). Interestingly, the 2D material-modified substrates exhibited a higher cell adhesion, spreading, and proliferation when compared with a non-treated (NT) substrate. Remarkably, in the case of differentiation, the MoS{sub 2}-, WS{sub 2}-, and BN-modified substrates exhibited a better performance in terms of guiding the adipogenesis of hADMSCs when compared with both NT and GO-modified substrates, based on the mRNA expression level (qPCR) and amount of lipid droplets (ORO staining). In contrast, the osteogenesis was found to be most efficiently induced by the GO-coated substrate (50 μg/mL) among all 2D-material coated substrates. In summary, 2D materials could act as favorable sources for controlling the stem cell growth and differentiation, which might be highly advantageous in both biomedical research and therapy. - Highlights: • The toxicity of four different two-dimensional materials on hADMSCs was studied. • All four different 2D materials enhanced the cell adhesion, spreading and proliferation. • WS{sub 2}-, MoS{sub 2}-, and BN-coated substrates enhanced the adipogenesis of hADMSCs. • GO showed the best performance for guiding the osteogenesis of hADMSCs.

60 APPLIED LIFE SCIENCES↗

Dimensionality effect of conductive carbon fillers in LiNi 1/3 Mn 1/3 Co 1/3 O 2 cathode

Developing advanced electrode architectures through modifying active materials, conductive fillers, binders, and electrolytes as well as processing methods has drawn significant research interest. Due to the insufficient electrical conductivity of many active materials, adding conductive carbon fillers to composite electrodes provides the necessary electrical conductivity. The dimensionality effect among different conductive fillers has a significant impact on electrochemistry, which can be associated with morphological and chemical heterogeneities of electrodes. In this study, synchrotron X-ray mosaic nanotomography and X-ray spectroscopy nanoimaging provided direct three-dimensional (3D) visualization and quantification capabilities to investigate the dimensionality effects of Super P (SP) and single-walled carbon nanotube (SWCNT) fillers on the capacity retention of LiNi 1/3 Mn 1/3 Co 1/3 O 2 (NMC111). The results indicate that NMC/SWCNT electrodes, with a wrapping effect from the SWCNTs, exhibited more homogeneous particle size distributions, morphological changes, and chemical states than NMC/SP electrodes, without the wrapping effect. This work developed a framework of 3D quantification methods to study the capacity fading behavior associated with morphological and chemical heterogeneities and paved the way toward designing electrodes for high rate energy storage applications.

25 ENERGY STORAGE↗

Engineering phonon transport through cation disorder in dimensionally constricted high entropy MXene

Designing materials with low thermal conductivity is a crucial objective for applications in thermal insulation and thermoelectrics. Traditional methods such as doping, mechanical strain and introducing defects in perfect crystals have been widely explored to impede the flow of heat. Here, this work introduces dimensional constriction and cationic disorder as novel avenues to manipulate lattice thermal conductivity (LTC). High entropy materials characterized by random distribution of multiple elements, creates a suitable environment for thermal insulation due to its configurational disorder and local lattice distortions. On the other hand, MXenes, derived from MAX-phase, have garnered considerable attention due to their unique structural attributes, leading to potential applications in catalysis and energy storage. Ti 2 AlC MAX-phase is examined to understand the impact of dimensional constriction on phonon transport of Ti 2 C with cationic disorder, i.e., (Ti 0.25 Nb 0.25 Cr 0.25 Ta 0.25 ) 2 C. The exponential reduction in LTC of HE-MXene is attributed to disorder scattering that significantly limits phonon mean free path (MFP) and relaxation time. The spread of mode-resolved LTC with MFP highlights the influence of disorder on phonon scattering. This work provides a systematic approach to engineer LTC through dimensional constriction and cationic disorder, laying the foundation for tailored materials with desired thermal properties.

2D materials↗

Implementations of two-dimensional liquid chromatography

Today scientists must deal with complex samples that either cannot be adequately separated using one-dimensional chromatography or that require an inordinate amount of time for separation. For these cases we need two-dimensional chromatography because it takes far less time to generate a peak capacity n{sub c} twice in a row than to generate a peak capacity n{sub c}{sup 2} once. Liquid chromatography has been carried out successfully on thin layers of adsorbents and along tubes filled with various adsorbents. The first type of separation sorts out the sample components in a physical separation space that is the layer of packing material. The analysis time is the same for all the components of the sample while their migration distance increases with decreasing retention. The resolution between two components having a certain separation factor (a) increases with increasing migration distance, i.e., from the strongly to the weakly retained compounds. In the second type of separation, the sample components are eluted from the column and separated in the time space, their migration distances are all the same while their retention times increase from the unretained to the strongly retained compounds. Separation efficiency varies little with retention, as long as the components are eluted from the column. We call these two types of separation the chromatographic separations in space (LC{sup x}) and the chromatographic separations in time (LC{sup t}), respectively. In principle, there are four ways to combine these two modes and do two-dimensional chromatographic separations, LC{sup t} x LC{sup t}, LC{sup x} x LC{sup t}, LC{sup t} x LC{sup x}, and LC{sup x} x LC{sup x}. We review, discuss and compare the potential performance of these combinations, their advantages, drawbacks, problems, perspectives and results. Currently, column-based combinations (LC{sup t} x LC{sup t}) are the most actively pursued. We suggest that the combination LC{sup x} x LC{sup t} shows exceptional promise because it permits the simultaneous second-dimension separations of all the fractions separated in the first-dimension, thus providing remarkable time saving.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Learning high-dimensional parametric maps via reduced basis adaptive residual networks

We propose a scalable framework for the learning of high-dimensional parametric maps via adaptively constructed residual network (ResNet) maps between reduced bases of the inputs and outputs. When just few training data are available, it is beneficial to have a compact parametrization in order to ameliorate the ill-posedness of the neural network training problem. By linearly restricting high-dimensional maps to informed reduced bases of the inputs, one can compress high-dimensional maps in a constructive way that can be used to detect appropriate basis ranks, equipped with rigorous error estimates. A scalable neural network learning framework is thus to learn the nonlinear compressed reduced basis mapping. Unlike the reduced basis construction, however, neural network constructions are not guaranteed to reduce errors by adding representation power, making it difficult to achieve good practical performance. Inspired by recent approximation theory that connects ResNets to sequential minimizing flows, we present an adaptive ResNet construction algorithm. This algorithm allows for depth-wise enrichment of the neural network approximation, in a manner that can achieve good practical performance by first training a shallow network and then adapting. We prove universal approximation of the associated neural network class for $L^2_v$ functions on compact sets. Our overall framework allows for constructive means to detect appropriate breadth and depth, and related compact parametrizations of neural networks, significantly reducing the need for architectural hyperparameter tuning. Numerical experiments for parametric PDE problems and a 3D CFD wing design optimization parametric map demonstrate that the proposed methodology can achieve remarkably high accuracy for limited training data, and outperformed other neural network strategies we compared against.

42 ENGINEERING↗

Conditional Karhunen–Loève regression model with Basis Adaptation for high-dimensional problems: Uncertainty quantification and inverse modeling

Here, we propose a methodology for improving the accuracy of surrogate models of the observable response of physical systems as a function of the systems’ spatially heterogeneous parameter fields, with applications to uncertainty quantification and parameter estimation in high-dimensional problems. Practitioners often formulate finite-dimensional representations of spatially heterogeneous parameter fields using truncated unconditional Karhunen–Loève expansions (KLEs) for a certain choice of unconditional covariance kernel and construct surrogate models of the observable response with respect to the KLE coefficients. When direct measurements of the parameter fields are available, we propose improving the accuracy of these surrogate models by representing the parameter fields via conditional Karhunen-Loève expansions (CKLEs). CKLEs are constructed by conditioning the covariance kernel of the unconditional expansion on the direct measurements of the parameter field via Gaussian process regression, and then truncating the corresponding KLE. We apply the proposed methodology to constructing surrogate models via the Basis Adaptation (BA) method of the stationary hydraulic head response, measured at spatially discrete observation locations, of a groundwater flow model of the Hanford Site, as a function of the 1000-dimensional representation of the model’s log-transmissivity field. We find that BA surrogate models of the hydraulic head based on CKLEs are more accurate than BA surrogate models based on unconditional expansions for forward uncertainty quantification tasks. Furthermore, we find that inverse estimates of the hydraulic transmissivity field computed using CKLE-based BA surrogate models are more accurate than those computed using unconditional BA surrogate models.

97 MATHEMATICS AND COMPUTING↗

Parallel three-dimensional simulations of quasi-static elastoplastic solids

Hypo-elastoplasticity is a flexible framework for modeling the mechanics of many hard materials under small elastic deformation and large plastic deformation. Under typical loading rates, most laboratory tests of these materials happen in the quasi-static limit, but there are few existing numerical methods tailor-made for this physical regime. Here, we extend to three dimensions a recent projection method for simulating quasi-static hypo-elastoplastic materials. The method is based on a mathematical correspondence to the incompressible Navier–Stokes equations, where the projection method of Chorin (1968) is an established numerical technique. We develop and utilize a three-dimensional parallel geometric multigrid solver employed to solve a linear system for the quasi-static projection. Our method is tested through simulation of three-dimensional shear band nucleation and growth, a precursor to failure in many materials. As an example system, we employ a physical model of a bulk metallic glass based on the shear transformation zone theory, but the method can be applied to any elastoplasticity model. We consider several examples of three-dimensional shear banding, and examine shear band formation in physically realistic materials with heterogeneous initial conditions under both simple shear deformation and boundary conditions inspired by friction welding.

97 MATHEMATICS AND COMPUTING↗

An experimental and one-dimensional modeling analysis of turbulent gas ejection in pre-chamber engines

In this work, experimental results from a study on the evolution of gas jets ejected through the orifices of a pre-chamber in a heavy-duty optical engine are presented. The work examines conditions without fuel inside the main-chamber, which helps to describe the dynamics of the ejected gas jets without the interference of subsequent combustion in the main-chamber. Experimental diagnostics consist of high-speed visible intensified imaging and low-speed infrared imaging. Additionally a one-dimensional gas jet model is used to characterize the spatial distribution of the ejected flow, including parameters such as tip penetration, which are then validated based on experimental results. Different stages in the ejection of pre-chamber jets are identified, with chemical activity restricted to a maximum distance of 5 to 10 orifice diameters downstream of the orifice as indicated by the recorded visible radiation. Sensitivity of cycle-to-cycle variations in pre-chamber jet development to the air-to-fuel ratio in the pre-chamber observed in the experiments is in most part attributed to the variations in the timing of combustion initiation in the pre-chamber. The influence of the ejection flow on the penetration of the gas jet on a cycle-to-cycle basis is presented using the one-dimensional model. The one-dimensional model also indicates that the local flow exhibits highest sensitivity to operating conditions during the start of ejection until the timing when maximum flow is attained. Differences that exist during the decreasing mass-flow ejection time-period tend to smear out in part due to the transient slowdown of the ejection process.

1-D gas jet model↗

Quality Assurance Challenges for Motion-Adaptive Radiation Therapy: Gating, Breath Holding, and Four-Dimensional Computed Tomography

Compared with conventional three-dimensional (3D) conformal radiation therapy and intensity-modulated radiation therapy treatments, quality assurance (QA) for motion-adaptive radiation therapy involves various challenges because of the added temporal dimension. Here we discuss those challenges for three specific techniques related to motion-adaptive therapy: namely respiratory gating, breath holding, and four-dimensional computed tomography. Similar to the introduction of any other new technologies in clinical practice, typical QA measures should be taken for these techniques also, including initial testing of equipment and clinical procedures, as well as frequent QA examinations during the early stage of implementation. Here, rather than covering every QA aspect in depth, we focus on some major QA challenges. The biggest QA challenge for gating and breath holding is how to ensure treatment accuracy when internal target position is predicted using external surrogates. Recommended QA measures for each component of treatment, including simulation, planning, patient positioning, and treatment delivery and verification, are discussed. For four-dimensional computed tomography, some major QA challenges have also been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Novel Amplitude/Phase Binning Algorithm on Commercial Four-Dimensional Computed Tomography Quality

Purpose: Respiratory motion is a significant source of anatomic uncertainty in radiotherapy planning and can result in errors of portal size and the subsequent radiation dose. Although four-dimensional computed tomography allows for more accurate analysis of the respiratory cycle, breathing irregularities during data acquisition can cause considerable image distortions. The aim of this study was to examine the effect of respiratory irregularities on four-dimensional computed tomography, and to evaluate a novel image reconstruction algorithm using percentile-based tagging of the respiratory cycle. Methods and Materials: Respiratory-correlated helical computed tomography scans were acquired for 11 consecutive patients. The inspiration and expiration data sets were reconstructed using the default phase-based method, as well as a novel respiration percentile-based method with patient-specific metrics to define the ranges of the reconstruction. The image output was analyzed in a blinded fashion for the phase- and percentile-based reconstructions to determine the prevalence and severity of the image artifacts. Results: The percentile-based algorithm resulted in a significant reduction in artifact severity compared with the phase-based algorithm, although the overall artifact prevalence did not differ between the two algorithms. The magnitude of differences in respiratory tag placement between the phase- and percentile-based algorithms correlated with the presence of image artifacts. Conclusion: The results of our study have indicated that our novel four-dimensional computed tomography reconstruction method could be useful in detecting clinically relevant image distortions that might otherwise go unnoticed and to reduce the image distortion associated with some respiratory irregularities. Additional work is necessary to assess the clinical impact on areas of possible irregular breathing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Rigid and Adaptive Methods of Propagating Gross Tumor Volume Through Respiratory Phases of Four-Dimensional Computed Tomography Image Data Set

Purpose: To compare three different methods of propagating the gross tumor volume (GTV) through the respiratory phases that constitute a four-dimensional computed tomography image data set. Methods and Materials: Four-dimensional computed tomography data sets of 20 patients who had undergone definitive hypofractionated radiotherapy to the lung were acquired. The GTV regions of interest (ROIs) were manually delineated on each phase of the four-dimensional computed tomography data set. The ROI from the end-expiration phase was propagated to the remaining nine phases of respiration using the following three techniques: (1) rigid-image registration using in-house software, (2) rigid image registration using research software from a commercial radiotherapy planning system vendor, and (3) rigid-image registration followed by deformable adaptation originally intended for organ-at-risk delineation using the same software. The internal GTVs generated from the various propagation methods were compared with the manual internal GTV using the normalized Dice similarity coefficient (DSC) index. Results: The normalized DSC index of 1.01 {+-} 0.06 (SD) for rigid propagation using the in-house software program was identical to the normalized DSC index of 1.01 {+-} 0.06 for rigid propagation achieved with the vendor's research software. Adaptive propagation yielded poorer results, with a normalized DSC index of 0.89 {+-} 0.10 (paired t test, p <0.001). Conclusion: Propagation of the GTV ROIs through the respiratory phases using rigid- body registration is an acceptable method within a 1-mm margin of uncertainty. The adaptive organ-at-risk propagation method was not applicable to propagating GTV ROIs, resulting in an unacceptable reduction of the volume and distortion of the ROIs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Intensity-Modulated Radiotherapy Planning for Dynamic Multileaf Collimator Tracking Radiotherapy

Purpose: To develop a four-dimensional intensity-modulated radiotherapy (IMRT) planning method for dynamic multileaf collimator (DMLC)-based tumor tracking that takes respiratory motion into consideration. Methods and Materials: Using the concept of optimal deformation, a series of apertures are placed at different phases in the same segment to ensure maximally similar dose contributions at various anatomic points. We used a direct aperture optimization method to find a set of segments that achieved an optimal dose distribution for aperture shapes at the reference phase and achieved corresponding optimal deformations at other phases that took respiratory motion into consideration. In our four-dimensional direct aperture optimization (4D-DAO) method, a simulated annealing algorithm and a conjugate gradients algorithm were used to optimize the shape of the segments and the monitor units, respectively. We then compared the optimization results for three-dimensional conformal radiotherapy and 4D-DAO based on a set of simulated respiration 4D computed tomography (4DCT) data and a set of real 4DCT data. Results: Dosimetric analysis indicated that, compared with the 3DCRT method, the dose distribution is significantly improved when the optimal deformation tracking technique is used, even when the maximum velocity limit of the DMLC leaves is set. Conclusions: The proposed 4D-IMRT planning method can find a set of segments and the corresponding leaf movements, which can trace the tumor motion and thus protect more normal tissue from radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential Dosimetric Benefits of Four-Dimensional Radiation Treatment Planning

Purpose: To determine the extent of dosimetric differences between conventional three-dimensional (3D) dose calculations and four-dimensional (4D) dose calculations based on deformation of organ models. Methods and Materials: Four-dimensional dose calculations were retrospectively performed on computed tomography data sets for 15 patients with Stage III non-small-cell lung cancer, using a model-based deformable registration algorithm on a research version of a commercial radiation treatment planning system. Target volume coverage and doses to critical structures calculated using the 4D methodology were compared with those calculated using conventional 3D methodology. Results: For 11 of 15 patients, clinical target volume coverage was comparable in the 3D and 4D calculations, whereas for 7 of 15 patients, planning target volume coverage was comparable. For the other patients, the 4D calculation indicated a difference in target volume dose sufficiently great to warrant replanning. No correlations could be established between differences in 3D and 4D calculations and gross tumor volume size or extent of motion. Negligible differences were observed between 3D and 4D dose-volume relationships for normal anatomic structures. Conclusions: Use of 4D dose calculations, when possible, helps ensure that target volumes will not be underirradiated when respiratory motion may affect the dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Clinical Evaluation of a Three-Dimensional Cone-Beam Computed Tomography Estimation Method Using a Deformation Field Map

Purpose: To develop a three-dimensional (3D) cone-beam computed tomography (CBCT) estimation method using a deformation field map, and to evaluate and optimize the efficiency and accuracy of the method for use in the clinical setting. Methods and Materials: We propose a method to estimate patient CBCT images using prior information and a deformation model. Patients' previous CBCT data are used as the prior information, and the new CBCT volume to be estimated is considered as a deformation of the prior image volume. The deformation field map is solved by minimizing deformation energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. This method was implemented in 3D form using hardware acceleration and multi-resolution scheme, and it was evaluated for different scan angles, projection numbers, and scan directions using liver, lung, and prostate cancer patient data. The accuracy of the estimation was evaluated by comparing the organ volume difference and the similarity between estimated CBCT and the CBCT reconstructed from fully sampled projections. Results: Results showed that scan direction and number of projections do not have significant effects on the CBCT estimation accuracy. The total scan angle is the dominant factor affecting the accuracy of the CBCT estimation algorithm. Larger scan angles yield better estimation accuracy than smaller scan angles. Lung cancer patient data showed that the estimation error of the 3D lung tumor volume was reduced from 13.3% to 4.3% when the scan angle was increased from 60 Degree-Sign to 360 Degree-Sign using 57 projections. Conclusions: The proposed estimation method is applicable for 3D DTS, 3D CBCT, four-dimensional CBCT, and four-dimensional DTS image estimation. This method has the potential for significantly reducing the imaging dose and improving the image quality by removing the organ distortion artifacts and streak artifacts shown in images reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography Internal Motion Tracking Should Be Used to Validate 4-Dimensional Computed Tomography for Abdominal Radiation Therapy Patients

Purpose: To demonstrate that fiducial tracking during pretreatment Cone-Beam CT (CBCT) can accurately measure tumor motion and that this method should be used to validate 4-dimensional CT (4DCT) margins before each treatment fraction. Methods and Materials: For 31 patients with abdominal tumors and implanted fiducial markers, tumor motion was measured daily with CBCT and fluoroscopy for 202 treatment fractions. Fiducial tracking and maximum-likelihood algorithms extracted 3-dimensional fiducial trajectories from CBCT projections. The daily internal margin (IM) (ie, range of fiducial motion) was calculated for CBCT and fluoroscopy as the 5th-95th percentiles of displacement in each cardinal direction. The planning IM from simulation 4DCT (IM{sub 4DCT}) was considered adequate when within ±1.2 mm (anterior–posterior, left–right) and ±3 mm (superior–inferior) of the daily measured IM. We validated CBCT fiducial tracking as an accurate predictive measure of intrafraction motion by comparing the daily measured IM{sub CBCT} with the daily IM measured by pretreatment fluoroscopy (IM{sub pre-fluoro}); these were compared with pre- and posttreatment fluoroscopy (IM{sub fluoro}) to identify those patients who could benefit from imaging during treatment. Results: Four-dimensional CT could not accurately predict intrafractional tumor motion for ≥80% of fractions in 94% (IM{sub CBCT}), 97% (IM{sub pre-fluoro}), and 100% (IM{sub fluoro}) of patients. The IM{sub CBCT} was significantly closer to IM{sub pre-fluoro} than IM{sub 4DCT} (P<.01). For patients with median treatment time t < 7.5 minutes, IM{sub CBCT} was in agreement with IM{sub fluoro} for 93% of fractions (superior–inferior), compared with 63% for the t > 7.5 minutes group, demonstrating the need for patient-specific intratreatment imaging. Conclusions: Tumor motion determined from 4DCT simulation does not accurately predict the daily motion observed on CBCT or fluoroscopy. Cone-beam CT could replace fluoroscopy for pretreatment verification of simulation IM{sub 4DCT}, reducing patient setup time and imaging dose. Patients with treatment time t > 7.5 minutes could benefit from the addition of intratreatment imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A least-squares approximation of partial differential equations with high-dimensional random inputs

Uncertainty quantification schemes based on stochastic Galerkin projections, with global or local basis functions, and also stochastic collocation methods in their conventional form, suffer from the so called curse of dimensionality: the associated computational cost grows exponentially as a function of the number of random variables defining the underlying probability space of the problem. In this paper, to overcome the curse of dimensionality, a low-rank separated approximation of the solution of a stochastic partial differential (SPDE) with high-dimensional random input data is obtained using an alternating least-squares (ALS) scheme. It will be shown that, in theory, the computational cost of the proposed algorithm grows linearly with respect to the dimension of the underlying probability space of the system. For the case of an elliptic SPDE, an a priori error analysis of the algorithm is derived. Finally, different aspects of the proposed methodology are explored through its application to some numerical experiments.

97 MATHEMATICS AND COMPUTING↗

CHARACTERIZATION OF DISCONTINUITIES IN HIGH-DIMENSIONAL STOCHASTIC PROBLEMS ON ADAPTIVE SPARSE GRIDS

In this paper we present a set of efficient algorithms for detection and identification of discontinuities in high dimensional space. The method is based on extension of polynomial annihilation for edge detection in low dimensions. Compared to the earlier work, the present method poses significant improvements for high dimensional problems. The core of the algorithms relies on adaptive refinement of sparse grids. It is demonstrated that in the commonly encountered cases where a discontinuity resides on a small subset of the dimensions, the present method becomes optimal , in the sense that the total number of points required for function evaluations depends linearly on the dimensionality of the space. The details of the algorithms will be presented and various numerical examples are utilized to demonstrate the efficacy of the method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗