Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

WE-AB-BRB-06: A Temperature Independent Plastic Scintillation Detector Capable of Simultaneous Dose and Temperature Measurement

Purpose: To evaluate a measurement method that renders plastic scintillation detectors temperature independent and capable of recovering dose and temperature information simultaneously. Methods: A novel approach was developed to account for the temperature dependence of plastic scintillation detectors (PSDs) without prior knowledge of the temperature. To enable this, the optical response of the scintillating element is separated into two sub-components, one being the response at a given temperature and the other accounting for the change in the optical emission spectrum with temperature. Using a previously demonstrated hyperspectral approach and following the proper calibration protocol, the contribution to scintillator emission and physical value of both dose and temperature can be obtained in real-time. To validate the method, dose and temperature were measured under cobalt irradiation in a temperature controlled water tank developed for this study. The temperature was varied from 22°C to 42°C. Depth-dose curves were also obtained during irradiations from a linear accelerator, first maintaining the water at room temperature and then warming it to 40°C and letting it cool down naturally over the course of the second measurement. Results: Dose measurements delivered with the Co-60 unit showed an average relative difference to the expected value of (1.0±0.8)%, with a maximum difference of 2.3% over the entire range of temperatures. The measured temperatures using the PSD were all within 1°C of the expected values. The difference between room temperature and warmer depth dose measurements differed by only (1.2±0.4)%. The dosimeter showed to be accurate for temporal resolution down to 0.1s. Conclusion: The proposed method was shown to reliably correct for the temperature dependence of a PSD. Additionally, it makes it possible to assess the temperature at the point of measurement. These are significant advances in PSD technology, particularly in relation to real-time in vivo dosimetry. Part of this research was supported by the Odyssey Program at The University of Texas MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

SU-F-J-224: Impact of 4D PET/CT On PERCIST Classification of Lung and Liver Metastases in NSLC and Colorectal Cancer

Purpose: To quantify the impact of 4D PET/CT on PERCIST metrics in lung and liver tumors in NSCLC and colorectal cancer patients. Methods: 32 patients presenting lung or liver tumors of 1–3 cm size affected by respiratory motion were scanned on a GE Discovery 690 PET/CT. The bed position with lesion(s) affected by motion was acquired in a 12 minute PET LIST mode and unlisted into 8 bins with respiratory gating. Three different CT maps were used for attenuation correction: a clinical helical CT (CT-clin), an average CT (CT-ave), and an 8-phase 4D CINE CT (CT-cine). All reconstructions were 3D OSEM, 2 iterations, 24 subsets, 6.4 Gaussian filtration, 192×192 matrix, non-TOF, and non-PSF. Reconstructions using CT-clin and CT-ave used only 3 out of the 12 minutes of the data (clinical protocol); all 12 minutes were used for the CT-cine reconstruction. The percent change of SUVbw-peak and SUVbw-max was calculated between PET-CTclin and PET-CTave. The same percent change was also calculated between PET-CTclin and PET-CTcine in each of the 8 bins and in the average of all bins. A 30% difference from PET-CTclin classified lesions as progressive metabolic disease (PMD) using maximum bin value and the average of eight bin values. Results: 30 lesions in 25 patients were evaluated. Using the bin with maximum SUVbw-peak and SUVbw-max difference, 4 and 13 lesions were classified as PMD, respectively. Using the average bin values for SUVbw-peak and SUVbw-max, 3 and 6 lesions were classified as PMD, respectively. Using PET-CTave values for SUVbw-peak and SUVbw-max, 4 and 3 lesions were classified as PMD, respectively. Conclusion: These results suggest that response evaluation in 4D PET/CT is dependent on SUV measurement (SUVpeak vs. SUVmax), number of bins (single or average), and the CT map used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

Extension of Complex Refractive Index Measurements to the Near-Infrared for Liquids: Methodology and Uncertainty Analysis

Optical identification of liquid droplets, aerosols, or thin films is important for many applications. While reference spectra are sometimes available for such measurements, they are not always applicable to the observed spectrum or the given sample morphology. Reference spectra for many forms can be modeled, however, if the n/k vectors (real and imaginary refractive indices) are available. In previous work we have reported protocols to determine the n/k vectors for dozens of liquids, primarily in the mid-infrared (MIR) spectral range from 7500 to 400 cm –1 . In this work we extend the spectral range into the near-infrared (NIR) region, demonstrating a method to measure and merge the data sets to create composite n/k data ranging from 10 000 to 400 cm –1 (1.0 to 25 µm) with absorbance fidelity spanning over four orders of magnitude, and vastly improved signal-to-noise in the NIR. The precision of the composite data is evaluated for three different liquids, focusing primarily on the steps for converting the raw absorbance spectra to k values. The variability in both MIR and NIR data as well as in the final n/k vectors is also investigated for several liquids. For typical liquids, the overall variability (reported as 2σ) in the final n and k-vectors is determined to be ∼0.4% and 3%, respectively. Finally, the derived n/k data are used to calculate absorbance spectra for aerosol droplets, showing marginal variability due to the typical measurement errors in the final n/k vectors.

47 OTHER INSTRUMENTATION↗

The global gridded crop model intercomparison: Data and modeling protocols for Phase 1 (v1.0)

We present protocols and input data for Phase 1 of the Global Gridded Crop Model Intercomparison, a project of the Agricultural Model Intercomparison and Improvement Project (AgMIP). The project consist of global simulations of yields, phenologies, and many land-surface fluxes using 12–15 modeling groups for many crops, climate forcing data sets, and scenarios over the historical period from 1948 to 2012. The primary outcomes of the project include (1) a detailed comparison of the major differences and similarities among global models commonly used for large-scale climate impact assessment, (2) an evaluation of model and ensemble hindcasting skill, (3) quantification of key uncertainties from climate input data, model choice, and other sources, and (4) a multi-model analysis of the agricultural impacts of large-scale climate extremes from the historical record.

54 ENVIRONMENTAL SCIENCES↗

CSULA Hydrogen Refueling Facility Performance Evaluation and Optimization

Throughout its history, Cal State LA has been in the forefront of advanced energy and transportation technologies. The station is located at the intersection of two major highways in Los Angeles region and has a convenient access. It is capable of producing up to 60 kg/day and can fuel 15-20 vehicles per day. Cal State LA had partnered with DOE to establish a robust station operation and performance data collection program. This consisted of equipping the station with additional instrumentation and collecting fueling performance data for several years. The data was further furnished to NREL for processing and agglomeration with data from other stations. In addition to fueling, maintenance and failure events were shared as well as hydrogen purity reports. The station has also undergone several upgrades in fueling protocols and hardware for improved performance and code compliance.

08 HYDROGEN↗

General Protocol for the Accurate Prediction of Molecular 13 C/ 1 H NMR Chemical Shifts via Machine Learning Augmented DFT

An accurate prediction of NMR chemical shifts at affordable computational cost is very important for different types of structural assignments in experimental studies. Density functional theory (DFT) and gauge-including atomic orbital (GIAO) are two of the most popular computational methods for NMR calculation, yet they often fail to resolve ambiguities in structural assignments. In this work, we present a new method that uses machine learning (ML) techniques (DFT + ML) that significantly increases the accuracy of 13 C/ 1 H NMR chemical shift prediction for a variety of organic molecules. The input of the generalizable DFT + ML model contains two critical parts: one is a vector providing insights into chemical environments, which can be evaluated without knowing the exact geometry of the molecule; the other one is the DFT-calculated isotropic shielding constant. The DFT + ML model was trained with a data set containing 476 13 C and 270 1 H experimental chemical shifts. For the DFT methods used here, the root mean square deviations (RMSDs) for the errors between predicted and experimental 13 C/ 1 H chemical shifts can be as small as 2.10/0.18 ppm, which is much lower than those from simple DFT (5.54/0.25 ppm), or DFT + linear regression (LR) (4.77/0.23 ppm) approaches. It also has a smaller maximum absolute error than two previously proposed NMR-predicting ML models. The robustness of the DFT + ML model is tested on two classes of organic molecules (TIC10 and hyacinthacines), where the correct isomers were unambiguously assigned to the experimental ones. Overall, the DFT + ML model shows promise for structural assignments in a variety of systems, including stereoisomers, that are often challenging to determine experimentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Workflow-based automatic processing for Internet of Floating Things crowdsourced data

Data from sensors incorporated into mobile devices, such as networked navigational sensors, can be used to capture detailed environmental information. We describe here a workflow and framework for using sensors on boats to construct unique new datasets of underwater topography (bathymetry). Starting with a large number of measurements of position, depth, etc., obtained from such an Internet of Floating Things, we illustrate how, with a specialized protocol, data can be communicated to cloud resources, even when using delayed, intermittent, or disconnected networks. We then propose a method for automatic sensor calibration based on a novel reputation approach. Sampled depth data are interpolated efficiently on a cloud computing platform in order to provide a continuously updated bathymetric database. Our prototype implementation uses the FACE-IT Galaxy workflow engine to manage network communication and exploits the computational power of GPGPUs in a virtualized cloud environment, working with a CUDA-parallel algorithm, for efficient data processing. We report on an initial evaluation involving data from a sailing vessel in Italian coastal waters.

97 MATHEMATICS AND COMPUTING↗

Water Contamination Impacts on Biodiesel Antioxidants and Storage Stability

Biodiesel (fatty acid methyl esters) can oxidize in storage to form acids and gums that negatively impact engine performance and durability. Antioxidant additives are used to increase biodiesel storage stability, and previous studies that evaluated the effectiveness of antioxidants demonstrated that more polar antioxidants tend to be the most effective (provide the largest improvement in stability per unit of antioxidant added). However, polar antioxidants have significant water solubility, and diesel fuel storage tanks are commonly contaminated with water (forming a layer of water under the fuel). This study investigates whether nonpolar antioxidants, which are less effective in dry environments, might be more effective under wet conditions simulating real-world storage. Biodiesel blends treated with polar and nonpolar antioxidants were subjected to accelerated aging using the ASTM D4625 protocol (storage at 43 °C, open to air, for up to 24 weeks) both with and without added water. Fuels treated with polar/higher-effectiveness compounds and stored in contact with water (simulating water in a storage tank) or high humidity showed accelerated loss of stability compared to dry storage. The same fuel treated with a nonpolar antioxidant and stored in the same conditions did not exhibit accelerated stability loss and thus had higher storage stability over the long term despite treatment with an initially less effective additive. Analysis of the fuels during aging showed that this loss of stability was not due to oxidation but rather extraction of the polar antioxidant into the water layer. Antioxidant additives that are incompatible with wet or humid storage conditions were found to cause faster-than-anticipated loss of stability, which was preventable with use of nonpolar additives.

09 BIOMASS FUELS↗

Benchmarking highly entangled states on a 60-atom analogue quantum simulator

Abstract Quantum systems have entered a competitive regime in which classical computers must make approximations to represent highly entangled quantum states 1,2 . However, in this beyond-classically-exact regime, fidelity comparisons between quantum and classical systems have so far been limited to digital quantum devices 2–5 , and it remains unsolved how to estimate the actual entanglement content of experiments 6 . Here, we perform fidelity benchmarking and mixed-state entanglement estimation with a 60-atom analogue Rydberg quantum simulator, reaching a high-entanglement entropy regime in which exact classical simulation becomes impractical. Our benchmarking protocol involves extrapolation from comparisons against an approximate classical algorithm, introduced here, with varying entanglement limits. We then develop and demonstrate an estimator of the experimental mixed-state entanglement 6 , finding our experiment is competitive with state-of-the-art digital quantum devices performing random circuit evolution 2–5 . Finally, we compare the experimental fidelity against that achieved by various approximate classical algorithms, and find that only the algorithm we introduce is able to keep pace with the experiment on the classical hardware we use. Our results enable a new model for evaluating the ability of both analogue and digital quantum devices to generate entanglement in the beyond-classically-exact regime, and highlight the evolving divide between quantum and classical systems.

Science & Technology - Other Topics↗

Process for Transition of Uranium Mill Tailings Radiation Control Act Title II Disposal Sites to the U.S. Department of Energy Office of Legacy Management for Long-Term Surveillance and Maintenance

This document presents guidance for implementing the process that the U.S. Department of Energy (DOE) Office of Legacy Management (LM) will use for assuming perpetual responsibility for a closed uranium mill tailings site. The transition process specifically addresses sites regulated under Title II of the Uranium Mill Tailings Radiation Control Act (UMTRCA) but is applicable in principle to the transition of sites under other regulatory structures, such as the Formerly Utilized Sites Remedial Action Program.

and Guidance↗

Graph Mining Meets the Semantic Web

The Resource Description Framework (RDF) and SPARQL Protocol and RDF Query Language (SPARQL) were introduced about a decade ago to enable flexible schema-free data interchange on the Semantic Web. Today, data scientists use the framework as a scalable graph representation for integrating, querying, exploring and analyzing data sets hosted at different sources. With increasing adoption, the need for graph mining capabilities for the Semantic Web has emerged. We address that need through implementation of three popular iterative Graph Mining algorithms (Triangle count, Connected component analysis, and PageRank). We implement these algorithms as SPARQL queries, wrapped within Python scripts. We evaluate the performance of our implementation on 6 real world data sets and show graph mining algorithms (that have a linear-algebra formulation) can indeed be unleashed on data represented as RDF graphs using the SPARQL query interface.

Lee, Sangkeun↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRA-07: Dosimetric Verification of the Valencia Skin Applicator Using Gafchromic EBT3 Film

Purpose: The Valencia applicators have recently been introduced for HDR treatment of small and shallow superficial skin lesions (< 20 mm diameter and 3-mm depth). Per AAPM TG 56, any HDR applicator internal dimensions must be verified prior to clinical use. However radiographic and tomographic imaging to validate the Valencia applicators is impractical due to the Tungsten alloy housing and flattening filter. In this study, we propose to use EBT3 film to indirectly confirm the physical integrity of the Valencia applicators. Methods: Treatment plans were created using the Oncentra MasterPlan TPS v4.5 for the H2 (20-mm dia.) and H3 (30-mm dia.) Valencia Applicators. A virtual CT phantom (2-mm slice thickness) was created with one source position in water. The published effective depth method was used for each applicator to delivery 500 cGy to a 3-mm depth using the TG-43 formalism. Film measurements (n=3) at 3-mm depth and vertical plane in solid water were performed for each applicator to verify the prescribed dose calculated by the TPS. Percent depth dose curves and off-axis profiles (phantom surface and 3-mm depth) were measured and compared to published data. Films were analyzed using an in-house written program and RIT113 v6 software. Film calibration was performed per TG-55 protocol using the Ir-192 source with NIST-traceable calibration. Results: The prescription absolute dose difference was 1% for the Valencia H2 applicator and 4% for the Valencia H3 applicator. The measured percent depth dose curves and off-axis dose profiles measured for the H2 and H2 Valencia applicators are in excellent agreement with the Granero et al. Monte Carlo results{sup 1}. Conclusion: Gafchromic EBT3 film can be used to indirectly verify the internal components of special HDR skin applicators constructed from high Z materials.{sup 1}Granero et al. “Design and evaluation of a HDR skin applicator with flattening filter”, Med. Phys. 35(2), 495–503, 2008.

60 APPLIED LIFE SCIENCES↗

SU-F-T-380: Comparing the Effect of Respiration On Dose Distribution Between Conventional Tangent Pair and IMRT Techniques for Adjuvant Radiotherapy in Early Stage Breast Cancer

Purpose: In this project, we compared the conventional tangent pair technique to IMRT technique by analyzing the dose distribution. We also investigated the effect of respiration on planning target volume (PTV) dose coverage in both techniques. Methods: In order to implement IMRT technique a template based planning protocol, dose constrains and treatment process was developed. Two open fields with optimized field weights were combined with two beamlet optimization fields in IMRT plans. We compared the dose distribution between standard tangential pair and IMRT. The improvement in dose distribution was measured by parameters such as conformity index, homogeneity index and coverage index. Another end point was the IMRT technique will reduce the planning time for staff. The effect of patient’s respiration on dose distribution was also estimated. The four dimensional computed tomography (4DCT) for different phase of breathing cycle was used to evaluate the effect of respiration on IMRT planned dose distribution. Results: We have accumulated 10 patients that acquired 4DCT and planned by both techniques. Based on the preliminary analysis, the dose distribution in IMRT technique was better than conventional tangent pair technique. Furthermore, the effect of respiration in IMRT plan was not significant as evident from the 95% isodose line coverage of PTV drawn on all phases of 4DCT. Conclusion: Based on the 4DCT images, the breathing effect on dose distribution was smaller than what we expected. We suspect that there are two reasons. First, the PTV movement due to respiration was not significant. It might be because we used a tilted breast board to setup patients. Second, the open fields with optimized field weights in IMRT technique might reduce the breathing effect on dose distribution. A further investigation is necessary.

60 APPLIED LIFE SCIENCES↗

Conversion of Syngas and CO2 to Light Olefins using Multi-Functional Catalysts

This report describes our effort in developing a novel zeolite encapsulated metal nanoparticle catalyst for the conversion of syngas to light olefins. We have adopted a ligand assisted synthesis protocol in which first metal-amine was prepared using metal salts and suitable amine ligands. The stable metal-amine complex thus prepared was then used as the seed for the growth of zeolite in alkaline solution. We have optimized the synthesis condition as well as different amine ligand to identify the condition to obtain stable metal-amine complex. Upon synthesis of zeolite, metal particles are encapsulated inside the zeolite in a confined space. We have synthesized both Fe and Co catalyst inside silicalite and chabazite zeolite. Catalytic activity of these catalysts were evaluated for syngas conversion reaction and compared with a baseline catalyst. The activity trend of zeolite encapsulated catalyst show very different activity trend compared to the baseline catalyst. While a distribution of products with different carbon number was obtained with baseline catalyst, zeolite encapsulated catalyst show ethylene as the major product. While ~73% selectivity to C 2 -C 6 products were obtained with cahabazite encapsulated Fe catalyst, only 53% selectivity was obtained for the corresponding products with silica-alumina supported Fe catalyst. Not only higher selectivity, Fe-chabazite also produces only C 2 products (ethylene/ethane) while a distribution of products was obtained with Fe-SiAl catalyst. The significantly different reactivity associated with the chabazite encapsulated Fe catalyst was attributed to the confinement effect. We hypothesized that due to the small size of the pore, only ethylene was obtained as the product.

10 SYNTHETIC FUELS↗

PLC Vulnerabilities and Mitigations

Programmable Logic Controllers (PLCs) are used extensively in many high-importance industrial and nonindustrial settings including controlling elevators, manufacturing machines, and utility facilities such as power and natural gas, however cybersecurity protection for them has been neglected. Within recent years, PLCs have been put under more security scrutiny and experts have advocated for changes from the addition of protocol encryption and network segmentation to intrusion detection systems on the PLCs themselves. While PLC security is critical, a large portion of the PLCs available today will never receive these changes due to being legacy or the difficulty of overhauling the security on existing systems. Due to the infeasibility of applying many recommended security measures towards currently available machines, we aim to provide realistic and affordable best practices for hardening PLCs. We will first conduct security analysis and consider attack vectors within our target PLC. Once we’ve analyzed the device’s security, we will evaluate a variety of mitigation methods and create guidelines to effectively reduce the threat posed by PLC attacks with minimal disruption to operations.

42 ENGINEERING↗

Chapter 6: An Improved Leaf Protoplast System for Highly Efficient Transient Expression in Switchgrass (Panicum virgatum L.)

As a robust perennial C4-type monocot plant and a native species to North America, switchgrass (Panicum virgatum) has been evaluated and designated as a strong candidate bioenergy crop by the U.S. DOE. Although genetic modifications of switchgrass have been used to successfully reduce the recalcitrance of switchgrass biomass for biofuel production, the generation of transgenic switchgrass is still a slow and laborious process. A transient protoplast system can provide an excellent platform to accelerate the selection of genes-of-interest for tailoring switchgrass biomass. However, partially due to the lack of the complete genomic information, the attempts to optimize the transient protoplast system for switchgrass remain scarce. In this chapter, we provide an improved protocol for switchgrass protoplast isolation, increased transformation efficiency using CsCl gradient ultracentrifugation-derived plasmid DNA and extended application of the transient switchgrass protoplast system to analyze protein expression using western blot.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗