Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

State Engagement in Electric Distribution System Planning

Electric distribution system planning is focused on assessing needed physical and operational changes to the local grid to maintain safe, reliable, and affordable service. While electric utilities have always engaged in this activity, the planning horizon has typically been short and involvement by state utility regulators minimal. Safety, reliability, and affordability remain top objectives for deeper state engagement in longer-term distribution system planning. Other drivers are proposed utility investments to replace aging infrastructure and modernize grids, opportunities to improve distribution system efficiency, enabling consumers to have greater control over energy costs and sources, and integrating higher levels of distributed energy resources (DERs) such as rooftop solar, distributed energy storage, and price-responsive demand. This report provides a snapshot of current state engagement in distribution system planning: •Part 1 describes activities in states that have adopted some elements of integrated distribution system planning and analysis (see Figure 1): New York, California, Hawaii, Massachusetts, and Minnesota. It summarizes their impetus for early action, stated goals, regulatory requirements, additional state activities related to distribution system planning, and next steps. •Part 2 covers a broader array of state approaches throughout the country. For example, some of these states have long-standing distribution reliability and performance codes, requiring regulated utilities to report regularly on poor-performing circuits and propose investments for improvements. Other states require regulated utilities to make filings related to proposed grid modernization investments. A growing number of states are beginning to consider comprehensive distribution system planning processes. As this report highlights, approaches vary significantly from state to state, in part stemming from differences in electricity market structure. States can learn from each other and tailor successful approaches to their unique circumstances. Reviewing the broad range of legislative and public utility commission activities described in this report is a useful starting point.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TAS::89 0927::TAS RECOVERY - The Lean Green Energy Controller Machine

Achieving efficiency improvements and providing demand-response programs have been identified as key elements of our national energy initiative. The residential market is the largest, yet most difficult, segment to engage in efforts to meet these objectives. This project developed Energy Management System that engages the consumer and enables Smart Grid services, applications, and business processes to address this need. Our innovative solution provides smart controller providing dynamic optimization of energy consumption for the residential energy consumer. Our solution extends the technical platform to include a cloud based Internet of Things (IoT) aggregation of data sensors and actuators the go beyond energy management and extend to life style services provided through compelling mobile and console based user experiences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Non-Equilibrium Chemistry and Darcy-Forchheimer Flow of Pyrolysis Gas for a Charring Ablator

The Fully Implicit Ablation and Thermal Response code, FIAT, simulates pyrolysis and ablation of thermal protection materials and systems. The governing equations, which include energy conservation, a three-component decomposition model, and a surface energy balance, are solved with a moving grid. This work describes new modeling capabilities that are added to a special version of FIAT. These capabilities include a time-dependent pyrolysis gas flow momentum equation with Darcy-Forchheimer terms and pyrolysis gas species conservation equations with finite-rate homogeneous chemical reactions. The total energy conservation equation is also enhanced for consistency with these new additions. Parametric studies are performed using this enhanced version of FIAT. Two groups of analyses of Phenolic Impregnated Carbon Ablator (PICA) are presented. In the first group, an Orion flight environment for a proposed Lunar-return trajectory is considered. In the second group, various test conditions for arcjet models are examined. The central focus of these parametric studies is to understand the effect of pyrolysis gas momentum transfer on PICA material in-depth thermal responses with finite-rate, equilibrium, or frozen homogeneous gas chemistry. Results are presented, discussed, and compared with those predicted by the baseline PICA/FIAT ablation and thermal response model developed by the Orion Thermal Protection System Advanced Development Project.

Ablation↗

Large-eddy simulation, fuel rod vibration and grid-to-rod fretting in pressurized water reactors

Grid-to-rod fretting (GTRF) in pressurized water reactors is a flow-induced vibration phenomenon that results in wear and fretting of the cladding material on fuel rods. GTRF is responsible for over 70% of the fuel failures in pressurized water reactors in the United States. Predicting the GTRF wear and concomitant interval between failures is important because of the large costs associated with reactor shutdown and replacement of fuel rod assemblies. The GTRF-induced wear process involves turbulent flow, mechanical vibration, tribology, and time-varying irradiated material properties in complex fuel assembly geometries. This paper presents a new approach for predicting GTRF induced fuel rod wear that uses high-resolution implicit large-eddy simulation to drive nonlinear transient dynamics computations. The GTRF fluid–structure problem is separated into the simulation of the turbulent flow field in the complex-geometry fuel-rod bundles using implicit large-eddy simulation, the calculation of statistics of the resulting fluctuating structural forces, and the nonlinear transient dynamics analysis of the fuel rod. Ultimately, the methods developed here, can be used, in conjunction with operational management, to improve reactor core designs in which fuel rod failures are minimized or potentially eliminated. Furthermore, robustness of the behavior of both the structural forces computed from the turbulent flow simulations and the results from the transient dynamics analyses highlight the progress made towards achieving a predictive simulation capability for the GTRF problem.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Review of Edge Computing Technology and Its Applications in Power Systems

Recent advancements in network-connected devices have led to a rapid increase in the deployment of smart devices and enhanced grid connectivity, resulting in a surge in data generation and expanded deployment to the edge of systems. Classic cloud computing infrastructures are increasingly challenged by the demands for large bandwidth, low latency, fast response speed, and strong security. Therefore, edge computing has emerged as a critical technology to address these challenges, gaining widespread adoption across various sectors. This paper introduces the advent and capabilities of edge computing, reviews its state-of-the-art architectural advancements, and explores its communication techniques. A comprehensive analysis of edge computing technologies is also presented. Furthermore, this paper highlights the transformative role of edge computing in various areas, particularly emphasizing its role in power systems. It summarizes edge computing applications in power systems that are oriented from the architectures, such as power system monitoring, smart meter management, data collection and analysis, resource management, etc. Additionally, the paper discusses the future opportunities of edge computing in enhancing power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Maui Smart Grid Demonstration Project Managing Distribution System Resources for Improved Service Quality and Reliability, Transmission Congestion Relief, and Grid Support Functions

The Maui Smart Grid Project (MSGP) is under the leadership of the Hawaii Natural Energy Institute (HNEI) of the University of Hawaii at Manoa. The project team includes Maui Electric Company, Ltd. (MECO), Hawaiian Electric Company, Inc. (HECO), Sentech (a division of SRA International, Inc.), Silver Spring Networks (SSN), Alstom Grid, Maui Economic Development Board (MEDB), University of Hawaii-Maui College (UHMC), and the County of Maui. MSGP was supported by the U.S. Department of Energy (DOE) under Cooperative Agreement Number DE-FC26-08NT02871, with approximately 50% co-funding supplied by MECO. The project was designed to develop and demonstrate an integrated monitoring, communications, database, applications, and decision support solution that aggregates renewable energy (RE), other distributed generation (DG), energy storage, and demand response technologies in a distribution system to achieve both distribution and transmission-level benefits. The application of these new technologies and procedures will increase MECO’s visibility into system conditions, with the expected benefits of enabling more renewable energy resources to be integrated into the grid, improving service quality, increasing overall reliability of the power system, and ultimately reducing costs to both MECO and its customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DER Cybersecurity Detection and Response Suite

SAND2024-08475O The Distributed Energy Resource (DER) Cybersecurity Detection and Response Suite is a solution for distributed energy resource (DER) systems. The DER Security Orchestration, Automation, and Response (SOAR) solution that uses alerts from signature- and behavior-based Intrusion Detection Systems are intended to be deployed as bump-in-the-wire (BITW) devices in front of DER equipment. The fielded application would use multiple intrusion detection systems that report data to SOAR to respond to cyberattacks. The suite consists of two software components: • The proactive intrusion detection and mitigation system (PIDMS) secures grid-edge photovoltaic smart inverters and other equipment in distributed energy resource systems. It is a distributed BITW solution; cyber and physical data are automatically processed using network inspection tools and custom machine learning algorithms to detect abnormal events and correlate cyber-physical events. • The Security Orchestration, Automation, and Response for Distributed Energy Resources (SOAR4DER) application ingests data from several intrusion detection systems to quickly block attacks and revert DER systems to good states. Using a collection of intrusion detection system technologies on a BITW device, it incorporates physical and cyber data to detect abnormal and potential malicious behaviors. Multiple SOAR playbooks then use the intrusion detection system data streams to automatically defend the system. SOAR4DER system testing showed detection and response times under 30 seconds for all adversary reconnaissance, denial-of-service attacks, malicious Modbus commands, brute-force logins, and machine-in-the-middle attacks. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, Jay↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Networked Control and Optimization for Widescale Integration of Power Electronic Devices in Residential Homes

Power electronics devices are emerging at residential houses, including electric vehicles, energy storage systems, solar photovoltaic systems, and variable-speed air conditioners. Little work has been done on scalable and end-to-end architectures for integrating and engaging large number of residential behind-the-meter assets to provide grid services. In this paper, a framework for integration of a demand management system, home energy management system, and residential smart inverters is presented. Full measured results of inverter response to control signals is also presented.

Starke, Michael↗

Reduced-Order Parameterized Short-Circuit Current Model of Inverter-Interfaced Distributed Generators

The short-circuit response of inverter-interfaced distributed generators (IIDGs) is not adequately represented in many conventional protection studies. This paper presents an in-depth analysis of IIDG behavior during grid faults and proposes a more accurate reduced-order parameterized short-circuit current (RPSC) model of inverters. Typical inverter components are thoroughly investigated to identify those that play dominant roles during faults. The paper shows that the current limiter is the dominant factor for the steady-state fault-current of inverter; while the inverter filter along with the severity of the voltage disturbance largely determine the initial transient spike of inverter fault current. The proposed model is low-order and can be used in large scale simulations. The parameters of the proposed RPSC model can be extracted from laboratory experiments without requiring proprietary manufacturer information. The proposed fault-current model is analogous to the well-known synchronous machine model that segregates the inverter fault current into subtransient, transient, and steady-state fault currents. Finally, experimental and simulation tests are presented to validate the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - runZero Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator™ (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CyberMESA: Evaluation Procedures and Metrics for Charging Infrastructure Cybersecurity

A report detailing the cybersecurity evaluation and assessment procedures for EV charging infrastructure. This report is authored by three national lab contributors. INL, PNNL, NRL. The grid integration of Electric Vehicle Charging Infrastructure (EVCI) is a large and complex system of systems (SoS) made up of components from many manufacturers and integrated by various companies responsible for their operation and maintenance. This complexity makes it challenging to implement security standards like IEC 62443 across the entire infrastructure. This document aims to aid in the vulnerability assessments of individual devices, such as Electric Vehicle Supply Equipment (EVSE), to support vendors in adopting and implementing security standards such as UL 2900, NIST SP 800-53 and Common Criteria (CC) (ISO/IEC 15408). This document serves as a guide to help evaluate the cybersecurity posture of EVCI assets. It aims to provide a consistent method for evaluating EVCI, enabling cybersecurity research teams to systematically test a wide range of electric vehicle (EV) assets. The target audiences include cybersecurity research teams, vendor development teams, automotive OEMs, and third-party evaluators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Navier-Stokes computations for oscillating control surfaces

Unsteady Navier-Stokes computations have been performed for simulating transonic flows over wings with oscillating control surfaces using a locally moving grid and a stationary-mismatched zoning scheme. An F-5 wing and a clipped delta wing are chosen for the present study. The computed unsteady pressures and the response characteristics to the control surface motions are compared with experimental data. The results successfully predict main features of the unsteady pressure profiles, such as the double peaks at the shock wave and at the hinge line.

Obayashi, Shigeru↗

Comparison and analysis of aircraft measurements and mesoscale atmospheric chemistry model simulations of tropospheric ozone

The Regional Acid Deposition Model (RADM) has been applied to several of the field experiments which were part of the Acid Models Operational and Diagnostic Evaluation Study (Acid MODES). The experiment which was of particular interest with regards to ozone photochemistry involved horizontal zig-zag flight patterns (ZIPPER) over an area from the eastern Ohio River valley to the Adirondacks of New York. Model simulations by both the standard resolution RADM (delta x = 80 km) and the nested grid RADM (delta x = 26.7 km) compare well to measurements in the low emission regions in central Pennsylvania and upstate New York, but underestimate in the high emission upper Ohio River valley. The nested simulation does considerably better, however, than the coarse grid simulation in terms of horizontal pattern and concentration magnitudes. Analysis of NO(x) and HO(x) concentrations and photochemical products rates of ozone show that the model's response to large point source emissions is very unsystematic both spatially and temporally. This is due to the models instability to realistically simulate the small scale (subgrid) gradients in precursor concentrations in and around large point source plumes.

Pleim, Jonathan E.↗

Wind Forcing of the North Sea Pole Tide

The Chandler wobble of the earth's rotation has a period near 14 months and sets up the 0.5 cm amplitude pole tide in the deep oceans, However, the pole tide is anomalously large in the North Sea, where the amplitude increases sharply up to 3 cm along the continental coast. It is shown here that the sea levels are well correlated with winds at the pole tide frequency. The Princeton Ocean Model is used to investigate the response of the North Sea to wind forcing. The barotropic numerical ocean model depicts realistic coastlines and bathymetry at 5 ft x 5 ft resolution, with 97 x 73 grid points. The monthly mean wind fields for the 40-year period (1958-1997) from the National Centers for Atmospheric Prediction (NCEP) reanalysis were used to force the model. The winds were converted to stress with a neutral drag coefficient that varied linearly with windspeed (instead of using the NCEP windstress). A 5-day simulation was made for each month until the resulting flow regime came into equilibrium, and model water levels at various station locations were saved for comparison with tidal-gauge observed sea levels from the Permanent Service for Mean Sea Level (PSMSL). The comparison is made for 10 North Sea stations with high quality tide gauge data. We find: (1) good agreement in annual and semi-annual phases and in the trend of amplitude w.r.t. latitude; (2) more importantly for this study, the model-predicted and observed non-seasonal sea level variations show a very significant temporal correlation as well as spectral coherence. However, a large amplitude difference exists between the two sets -- the overall amplitude variability of the observed is generally a factor of 2-3 larger than the model prediction (this same phenomenon has been reported in ocean circulation studies, although the cause is not yet clear.) Our results indicate that the wind forcing is the main cause of the observed large pole tide in the North Sea.

OConnor, W.↗

Gas Scintillation Proportional Counters for High-Energy X-ray Astronomy

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a balloon-borne hard-x-ray telescope is under development at the Marshall Space Flight Center. These detectors have an active area of approx. 20 sq cm, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approx. 500 microns. The detector s energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Full details of the instrument and its performance will be provided.

Gubarev, Mikhail↗