Search NASA⌕ Search

SEARCH · Search NASA

Results for “load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Four-probe measurements with a three-probe scanning tunneling microscope

We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of the plasma geometry on divertor power exhaust: experimental evidence from $\mathrm{TCV}$ and simulations with SolEdge2D and $\mathrm{TOKAM3X}$

A deep understanding of plasma transport at the edge of magnetically confined fusion plasmas is needed for the handling and control of heat loads on the machine first wall. Experimental observations collected on a number of tokamaks over the last three decades taught us that heat flux profiles at the divertor targets of X-point configurations can be parametrized by using two scale lengths for the scrape-off layer (SOL) transport, separately characterizing the main SOL (λ q ) and the divertor SOL (S q ). Here in this work we challenge the current interpretation of these two scale lengths as well as their dependence on plasma parameters by studying the effect of divertor geometry modifications on heat exhaust in the Tokamak à Configuration Variable. In particular, a significant broadening of the heat flux profiles at the outer divertor target is diagnosed while increasing the length of the outer divertor leg in lower single null, Ohmic, L-mode discharges. Efforts to reproduce this experimental finding with both diffusive (SolEdge2D-EIRENE) and turbulent (TOKAM3X) modelling tools confirm the validity of a diffusive approach for simulating heat flux profiles in more traditional, short leg, configurations while highlighting the need of a turbulent description for modified, long leg, ones in which strongly asymmetric divertor perpendicular transport develops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Post-puff SOL broadening on MAST-U under high-recycling conditions: evidence consistent with cross-field transport changes

Transient broadening of the scrape-off layer (SOL) density profile can modify main-chamber first-wall particle fluxes and divertor loading, yet its control parameters remain debated between divertor-regime transitions, neutral dynamics and changes in cross-field transport. We investigate fueling-driven SOL density-profile evolution and post-fueling relaxation on MAST-Upgrade (MAST-U) in ohmic L-mode, using two otherwise similar double-null Conventional Divertor discharges (I p = 450 kA, B T = 0.33 T) with identical 50 ms low-field side gas puffs; the only intentional difference is the puff start time. Upstream Thomson scattering shows that both discharges develop a transient far-SOL density profile modification, expressed as an increased SOL-width metric λ n e and a far-SOL enhancement consistent with a shoulder-like signature. In the earlier-puff case, the SOL-width metric remains elevated after puff termination and the post-puff decay time scales are systematically longer across the analysed radii. Outer-target Langmuir probes indicate high-recycling conditions during the analysed window (few-eV T e with radially peaked j sat,∥ and q ∥ profiles, without signatures of deep detachment). The outer-divertor collisionality proxy Λ div is elevated in both cases and does not discriminate between the different post-puff persistence. The target-integrated ion flux proxy ∫ J sat dA evolves nearly identically in both discharges when aligned to the puff start. Taken together, these observations suggest that the late/post-puff upstream SOL evolution is not set by parallel exhaust to the outer targetalone and is more consistent with upstream cross-field redistribution, with a possible role for plasma–neutral coupling and fueling geometry.

MAST-U↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Metal Amorphous Nanocomposite Soft Magnetic Material-Enabled High Power Density, Rare Earth Free Rotational Machines [Metal Amorphous Nanocomposite (MANC) Soft Magnetic Material (SMM) Enabled High Power Density, Rare Earth Free Rotational Machines]

Metal amorphous nanocomposites (MANCs) are promising soft magnetic materials (SMMs) for power electronic applications offering low power loss at high frequency and maintaining a relatively high flux density. While applications in certain motor designs have been recently modeled, their widespread application awaits scaled manufacturing of MANC materials and proliferation of new higher speed motor designs. A hybrid motor design based on permanent magnets and doubly salient stator and rotor is reported here to develop a compact (a factor of 10 smaller than currently possible in Si steels), high-speed (>1 kHz, electrical), high-power (>2.5 kW) motor by incorporating low loss (<10 W/kg at 1 kHz) MANCs such as recently reported Fe-Ni-based alloys. A feature of this motor design is flux focusing from the permanent magnet allowing use of lower energy permanent magnet chosen from among non-rare earth containing compositions and attractive due to constraints posed by rare earth criticality. A 2-D finite element analysis model reported here indicates that a 2.5 kW hybrid motor may be built with a permanent magnet with a 0.4 T remanence at a rotor speed of 6000 rpm. At a magnetic switching frequency of 1.4 kHz, the core loss may be limited to <3 W by selecting an appropriate MANC SMM. The projected efficiency exceeds 96% not including power loss in the controller. Under full load conditions, the flux density distributions for the SMM stay predominantly <1.3 T, the saturation magnetization of optimized FeNi-based MANC alloys. As a result, the maximum demagnetizing field in the permanent magnet is less than 2.2 × 10 5 A/m sustainable, for example, with a high-grade hard ferrite magnet.

42 ENGINEERING↗

PHASE CHANGE MATERIAL FOR THERMAL ENERGY STORAGE IN BUILDINGS BASED ON SODIUM SULFATE DECAHYDRATE AND DISODIUM HYDROGEN PHOSPHATE DODECAHYDRATE

The worldwide increasing energy demand and 2050 net zero carbon target urge the globe to solve the energy challenge. Thermal Energy Storage (TES) has received significant attention in recent years as TES can be integrated into heating, ventilation, and air-conditioning systems where the energy would be stored during low-demand times and dispatched during high-demand times, resulting in controlling the peak load and improving energy savings. Material development is an integral part of TES. Salt hydrates are appealing due to cost-effectiveness, low- to no toxicity, and their high melting enthalpy, where energy is stored as latent heat. However, most salt hydrates are prone to incongruent melting (i.e., phase separation upon melting), which results in poor stability and large supercooling. In this study, we produced a highly stable novel energy storage material at a composition of 32 wt% sodium sulfate decahydrate, 52 wt% sodium phosphate dibasic dodecahydrate, 12 wt% milled expanded graphite, and 4 wt% borax. The material has a melting temperature of 28°C and an energy storage capacity of 167 kJ/kg with a supercooling of less than 3°C. The system showed no loss in energy storage performance after 150 cycles. The findings suggest that the novel energy storage material developed in this might be utilized in building heating and cooling applications.

Turnaoglu, Tugba↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

A Parallel Ghosting Algorithm for The Flexible Distributed Mesh Database

Critical to the scalability of parallel adaptive simulations are parallel control functions including load balancing, reduced inter-process communication and optimal data decomposition. In distributed meshes, many mesh-based applications frequently access neighborhood information for computational purposes which must be transmitted efficiently to avoid parallel performance degradation when the neighbors are on different processors. This article presents a parallel algorithm of creating and deleting data copies, referred to as ghost copies, which localize neighborhood data for computation purposes while minimizing inter-process communication. The key characteristics of the algorithm are: (1) It can create ghost copies of any permissible topological order in a 1D, 2D or 3D mesh based on selected adjacencies. (2) It exploits neighborhood communication patterns during the ghost creation process thus eliminating all-to-all communication. (3) For applications that need neighbors of neighbors, the algorithm can create n number of ghost layers up to a point where the whole partitioned mesh can be ghosted. Strong and weak scaling results are presented for the IBM BG/P and Cray XE6 architectures up to a core count of 32,768 processors. The algorithm also leads to scalable results when used in a parallel super-convergent patch recovery error estimator, an application that frequently accesses neighborhood data to carry out computation.

Mubarak, Misbah↗

Experimental Study on Surrogate Nuclear Fuel Rods under Reversed Cyclic Bending

The mechanical behavior of spent nuclear fuel (SNF) rods under reversed cyclic bending or bending fatigue must be understood to evaluate their vibration integrity in a transportation environment. This is especially important for high-burnup fuels (>45 GWd/MTU), which have the potential for increased structural damage. It has been demonstrated that the bending fatigue of SNF rods can be effectively studied using surrogate rods. In this investigation, surrogate rods made of stainless steel (SS) 304 cladding and aluminum oxide pellets were tested under load or moment control at a variety of amplitude levels at 5 Hz using the Cyclic Integrated Reversible-Bending Fatigue Tester developed at Oak Ridge National Laboratory. The behavior of the rods was further characterized using flexural rigidity and hysteresis data, and fractography was performed on the failed rods. The proposed surrogate rods captured many of the characteristics of deformation and failure mode observed in SNF, including the linear-to-nonlinear deformation transition and large residual curvature in static tests, PPI and PCMI failure mechanisms, and large variation in the initial structural condition. Rod degradation was measured and characterized by measuring the flexural rigidity; the degradation of the rigidity depended on both the moment amplitude applied and the initial structural condition of the rods. It was also shown that a cracking initiation site can be located on the internal surface or the external surface of cladding. Finally, fatigue damage to the bending rods can be described in terms of flexural rigidity, and the fatigue life of rods can be predicted once damage model parameters are properly evaluated. The developed experimental approach, test protocol, and analysis method can be used to study the vibration integrity of SNF rods in the future.

cladding failure↗

AmeriFlux US-KS2 Kennedy Space Center (scrub oak)

This is the AmeriFlux version of the carbon flux data for the site US-KS2 Kennedy Space Center (scrub oak). Site Description - The Kennedy Space Center Scrub Oak site is located within the Merritt Island National Wildlife Refuge at the Kennedy Space Center (KSC) on the east coast of central Florida. Situated in a 10 ha scrub oak ecosystem, the surrounding stand was completely burned by a prescribed fire in 1996. The purpose of the burn was to control understory fuel load, which has been a common practice since 1969. Within a few weeks of the 1996 burn, the stand began to naturally regenerate from roots and rhizomes. Most scrub oak stands in the region undergo a 7 to 10 year disturbance cycle, mostly related to fire or hurricane activity. A severe drought gripped most of Florida beginning in 1998 until the later half of 2001 resulting in four years of relatively low amount of annual rainfall. Exceptionally high annual rainfall amount in 2004 was the result of a pair of hurricanes that hit the area in August and September of 2004. Prevaling wind directions for the site are as follows: W to NW in the winter, afternoon E sea breeze in the summer.

Drake, Bert↗

AmeriFlux FLUXNET-1F US-KS2 Kennedy Space Center (scrub oak)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-KS2 Kennedy Space Center (scrub oak). This is the FLUXNET version of the carbon flux data for the site US-KS2 Kennedy Space Center (scrub oak) produced by applying the standard ONEFlux (1F) software. Site Description - The Kennedy Space Center Scrub Oak site is located within the Merritt Island National Wildlife Refuge at the Kennedy Space Center (KSC) on the east coast of central Florida. Situated in a 10 ha scrub oak ecosystem, the surrounding stand was completely burned by a prescribed fire in 1996. The purpose of the burn was to control understory fuel load, which has been a common practice since 1969. Within a few weeks of the 1996 burn, the stand began to naturally regenerate from roots and rhizomes. Most scrub oak stands in the region undergo a 7 to 10 year disturbance cycle, mostly related to fire or hurricane activity. A severe drought gripped most of Florida beginning in 1998 until the later half of 2001 resulting in four years of relatively low amount of annual rainfall. Exceptionally high annual rainfall amount in 2004 was the result of a pair of hurricanes that hit the area in August and September of 2004. Prevaling wind directions for the site are as follows: W to NW in the winter, afternoon E sea breeze in the summer.

Drake, Bert↗

Development of a Hydrogen Energy System as a Grid Frequency Management Tool

The Hawai‘i Natural Energy Institute (HNEI) is conducting research to assess the technical potential of using an electrolyzer-based hydrogen (H2) production and storage system as a grid demand response tool using battery data from a 200 MW grid to show the kind of response required. The hydrogen produced by the electrolyzer is used for transportation. A 65 kg/day hydrogen energy system (HES) consisting of a PEM electrolyzer, 35 bar buffer tank, 450 bar compressor, and associated chiller systems was purchased and installed at the Hawaii Natural Energy Laboratory Hawaii Authority (NELHA) to demonstrate long-term durability of the electrolyzer under cyclic operation required for frequency regulation on an island grid system. The excess hydrogen was stored for use by three fuel-cell buses to be operated at Hawai‘i Volcanoes National Park (HAVO) and by the County of Hawai‘i Mass Transit Agency (MTA). This paper describes the site selection and equipment commissioning, plus a comprehensive test plan that was developed to characterize the performance and durability of the electrolyzer under dynamic load conditions. The controls were modified for the operating envelope and dynamic limits of the electrolyzer. While the data showed these modifications significantly improved the system response time, it is not fast enough to match a BESS response time for grid frequency management. The electrolyzer can only be used for slower acting changes (1 to 0.5 Hz). A potential solution is to design an electrolyzer/BESS hybrid system and develop a modeling program to find the optimum mix of battery and electrolyzer to provide the maximum grid regulation services at minimum cost.

08 HYDROGEN↗

Fracture Effects on Explosive Response (FEER); FY2018 Report

It is known that the violence of explosive response is affected by inertial and mechanical confinement. In a mechanical insult, the impact location creates a contact pressure that can act as confinement surrounding the ignition location, as has been observed in the Skid Test experiment. Under certain conditions — the details of which have not been well characterized — the ignition can produce cracking in the explosive, down which flames are observed to propagate. Cracks serve to simultaneously provide additional surface area for accelerating the reaction, as well as vent paths for quenching the reaction. These are competing behaviors, and the factors which govern the outcome are poorly described. A new experiment was devised to examine the effect of a controlled pre-load pressure on the explosive response. Sixteen experiments were performed on 1-inch thick discs of PBX 9501, with diameters of 1 in ch, 4.25 in ch, and 5 in ch. The explosive was compressed to a known pre-load between two clear windows and ignited at the center of the bottom surface with a focused laser impinging on a graphite inclusion. The ensuing reaction was imaged through the windows used to compress the sample, and from the side. A speckle pattern was applied to some samples for performing DIC (digital image correlation) for the purpose of quantifying the strain field and tracking crack growth. A threshold behavior was observed, in which higher-pressure pre-load resulted in cracks forming, while lower-pressure pre-load vented across the face of the explosive. This report presents the preliminary results, discusses the observations, enumerates hypotheses regarding the observed behavior, identifies lessons learned, and outlines a path forward for the next round of testing. Proof testing was only recently concluded and considerable additional analysis is required. These data will be valuable for the ongoing development of a constitutive mechanical and cracking failure model that will aid in predicting explosive response in mechanical impact scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

MEITNER Resource Team Modeling and Simulation Support to Holos-Quad Reactor Development (Final CRADA Report)

The main objective of this CRADA is to provide Argonne National Laboratory (ANL)’s modeling and simulation capabilities via ARPA-E's MEITNER (Modeling-Enhanced Innovations Trailblazing Nuclear Energy Reinvigoration) Resource Team (RT) arrangement to support the demonstration of the viability of HolosGen’s Holos-Quad reactor design. The Holos-Quad reactor design is an advanced reactor concept that incorporates many new design features, such as the neutron-coupled Subcritical Power Modules (SPMs) in its core design, elimination of balance of plant (BOP) by direct integration of a helium Brayton cycle power conversion system with each SPM, among many other innovative features. The demonstration of the viability of such an innovative reactor design warrants iterations of modeling and simulation and testing. The purpose of this project is to utilize ANL’s modeling and simulation capabilities in nuclear reactor analysis and power conversion system analysis to inform HolosGen and the Design Team (DT) in the design and optimization of the Holos-Quad concept. The major work scopes of this project include: to investigate conceptual designs and materials for radiation shielding to protect personnel and internal components such as turbomachinery; Assess the the helium Brayton cycle power conversion system performance in both nominal and load following conditions; Investigate power conversion components and overall system performance; Identify control strategies to enable load following; Perform simulations of HolosGen’s subscale simulator and using available test data for code validation/benchmark purpose; Perform core thermal-hydraulics, safety analysis, and structural analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Integration of Rationally Designed Dilute Alloy Catalysts for Energy-Efficient Electrochemical CO 2 -To-Fuel Conversion

Energy effiecient electrochemical conversion of CO 2 to high-demand chemicals and transportation fuels using renewable solar and wind energy is a key technology needed for a high-productivity, low-carbon future. However, the development of scalable, low-cost, active, selective, and stable electrocatalysts remains a key challenge that needs to be overcome to enable high-volume conversion of CO 2 to feedstock chemicals for the chemical industry. In previous work, Lawrence Livermore National Laboratory (LLNL) has developed a rational design platform for dilute alloy transition metal electrocatalysts that promise to make electrochemical CO 2 conversion more energy efficient and selective. In this project, we worked with our industrial partners, Twelve and TotalEnergies, to improve scale up, integration, and stability of LLNL’s dilute alloy catalyst technology into an industry-relevant zero gap electrolyzer platform. Through virtual experiments and data analysis, we designed efficient and cost-effective copper-based catalysts. The catalyst was specifically designed to streamline the slowest and most energy-intensive step of the electrochemical chemical transformation of CO 2 to multi-carbon products – that is making the carbon-carbon bond by dimerization of the reaction intermediate carbon monoxide - resulting in up to 10% improvement in energy efficiency for C 2 products while simultaneously increasing the selectivity towards C 2 products. We tested two different scalable catalyst coating technologies and down-selected magnetron sputtering as the technique that provided the best control over catalyst loading, composition, and morphology. Using this technology, we successfully demonstrated integration of our dilute alloy catalysts into a 100 cm 2 electrolyzer platform with Faradaic efficiencies for ethylene production reaching 40% at a current density of 200 mA/cm 2 . We also developed the technology to integrate a well-defined nanoscale porosity by depositing alloy compositions that were compatible with dealloying, that is, selective leaching of an alloy component to generate nanoscale porosity. We observed that integration of the dealloying-derived nanoporosity improved catalyst performance and stability by leading to a more hydrophobic catalyst/anion exchange membrane interface. Unsolved problems that still need to be addressed are corrosion of the Cu catalyst -specifically if the used catalyst is exposed to air - as well as long term stability do to salt formation/deposition and flooding of the catalyst/electrolyzer flow channels, especially at higher current densities. As we only worked on optimization of catalyst composition, coating thickness, and morphology, further performance optimization will require a system level approach that includes optimization of electrolyzer design and membrane technology.

36 MATERIALS SCIENCE↗

Summary of FY2024 Experimental Results to Support Development of New Inelastic Material Models and Validation of Section III, Division 5, Class A Design Rules

To address the data gap crucial for updating existing viscoplastic constitutive material models for the Class A materials in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III, Division 5, High Temperature Reactors (ASME, 2023) for inelastic design analysis, Oak Ridge National Laboratory (ORNL) conducted experimental studies on Alloy 800H and Alloy 617 across a range of temperatures up to their maximum temperature limits in Section III, Division 5. The studies aim to characterize the materials' deformation behavior under both strain-controlled mechanical cyclic loading and thermal cycling conditions. This report summarizes ORNL's FY 2024 experimental findings on Alloy 800H and Alloy 617, focusing on pure fatigue tests, cyclic stress-strain curves, thermomechanical fatigue experiments, and verification of the high temperature cyclic damage summation design rules.

36 MATERIALS SCIENCE↗

Potential Impacts of Dynamic Electricity Pricing in California: Load Shape and Customer Bill Impacts Under Elastic Customer Response

The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resiliency using Hydro-based Microgrids During Wildfires

The primary objective of this project is to assess the techno-economic viability of hydropower resources with supplementary investments, including microgrid controllers, storage solutions, load banks, additional generation like diesel generators, communication links, and transmission infrastructure. The aim is to enable these systems to operate autonomously (in islanded mode) and ensure grid resiliency during and after wildfire events. The project seeks to establish a comprehensive framework for setting up hydropower-based microgrids, from risk estimation to final investment decisions. These microgrids can provide critical support during emergencies and offer additional grid stability and revenue opportunities during regular operations and other system contingencies.

24 POWER TRANSMISSION AND DISTRIBUTION↗