San Diego Water Resources: Monitoring Pollution Plumes due to Storm and Wastewater Runoff in the San Diego Bay and Tijuana River Estuary to Inform Water Quality Management

Stormwater and wastewater runoff are a large source of pollutant discharge along the southern California coast and are a major concern to the health of local communities and ecosystems. In partnership with the Tijuana River National Estuarine Research Reserve and the California Department of Environmental Quality, NASA DEVELOP utilized satellite imagery to visualize and analyze the water quality of the Tijuana Estuary and southern California coast after major storm and wastewater events. Using Landsat 8 Operational Land Imager (OLI) and Sentinel-2 Multispectral Instrument (MSI), we estimated the extent and severity of plumes released from the Tijuana River Estuary. We used remotely sensed turbidity to map the extent of plumes, and used remotely sensed turbidity, Chlorophyll-a (chl-a), and colored dissolved organic matter (CDOM) to quantify and visualize stormwater, wastewater, and mixed plumes from 2013 to 2022. Furthermore, remotely sensed CDOM, turbidity, and chl-a were validated with in-situ data from NOAA and the San Diego Public Utilities in the San Diego coastal area to evaluate the accuracy of water quality data derived from satellite imagery. End products of this project include maps of stormwater, wastewater, and mixed plumes, tables illustrating the average area, CDOM, turbidity, and chl-a of each plume type, and validation graphs between satellite and in-situ data sources. These end products informed the environmental management of the Tijuana River National Estuarine Research Reserve and the public beaches in San Diego.

Ethan Gates↗

A Proposal for Geologic Radioactive Waste Disposal Environmental Zero-State and Subsequent Monitoring Definition - First Lessons Learned from the French Environment Observatory - 13188

Obtaining a reference state of the environment before the beginning of construction work for a geological repository is essential as it will be useful for further monitoring during operations and beyond, thus keeping a memory of the original environmental state. The area and the compartments of the biosphere to be observed and monitored as well as the choice of the markers (e.g. bio-markers, biodiversity, quality of the environment, etc.) to be followed must be carefully selected. In parallel, the choice and selection of the environmental monitoring systems (i.e. scientific and technical criteria, social requirements) will be of paramount importance for the evaluation of the perturbations that could be induced during the operational phase of the repository exploitation. This paper presents learning points of the French environment observatory located in the Meuse/Haute-Marne that has been selected for studying the feasibility of the underground disposal of high level wastes in France. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze the scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.

60 APPLIED LIFE SCIENCES↗

San Joaquin Valley Health & Air Quality: Evaluating the Overlap of Social Vulnerabilities and Air Quality in the San Joaquin Valley Air Pollution Control District

Little Manila Rising (LMR) is a nonprofit in Stockton, California that has been increasingly concerned by the air pollution in their city and the neighboring San Joaquin Valley (SJV). Geographical factors, climate conditions, and anthropogenic activities, such as agriculture burning and vehicle emissions, contribute to the high levels of air pollution in this region. To visualize the distribution of air pollution and social disparities across the SJV, LMR partnered with NASA DEVELOP. The DEVELOP team used Terra and Aqua MODIS, Sentinel-5P TROPOMI, and CALIPSO CALIOP to observe Aerosol Optical Depth (AOD), Nitrogen Dioxide (NO 2 ), and the vertical distribution of pollutants at varying pollution levels, respectively. Additionally, Suomi-NPP VIIRS provided active fire data. By leveraging NASA Earth observations along with sociodemographic and public health data, the DEVELOP team created maps identifying the areas experiencing the highest vulnerabilities and disparities in pollution exposure. The team found that AOD was slightly higher in agricultural regions, while NO 2 was consistently higher along transportation corridors and urban areas. Wildfires dominated the type of detected active fires, and there was high correlation (R 2 = 0.6924) between active fires and burn permits in agricultural tracts. Furthermore, the team identified both high AOD vulnerability and high NO 2 vulnerability in census tracts in South Stockton, an area that has been historically redlined and disinvested in, and where LMR resides. There was also a moderate correlation between air quality reported from the satellites and in-situ ground monitors. These results will support LMR’s organizing strategies for stricter enforcement of air pollution regulations and increased public health equity for community members.

Agricultural Fires↗

Antimisting kerosene: Base fuel effects, blending and quality control techniques

The problems associated with blending of the AMK additive with Jet A, and the base fuel effects on AMK properties are addressed. The results from the evaluation of some of the quality control techniques for AMK are presented. The principal conclusions of this investigation are: significant compositional differences for base fuel (Jet A) within the ASTM specification DI655; higher aromatic content of the base fuel was found to be beneficial for the polymer dissolution at ambient (20 C) temperature; using static mixer technology, the antimisting additive (FM-9) is in-line blended with Jet A, producing AMK which has adequate fire-protection properties 15 to 20 minutes after blending; degradability of freshly blended and equilibrated AMK indicated that maximum degradability is reached after adequate fire protection is obtained; the results of AMK degradability as measured by filter ratio, confirmed previous RAE data that power requirements to decade freshly blended AMK are significantly higher than equilibrated AMK; blending of the additive by using FM-9 concentrate in Jet A produces equilibrated AMK almost instantly; nephelometry offers a simple continuous monitoring capability and is used as a real time quality control device for AMK; and trajectory (jet thurst) and pressure drop tests are useful laboratory techniques for evaluating AMK quality.

Yavrouian, A. H.↗

Defining Golden Batches in Biomanufacturing Processes From Internal Metabolic Activity to Detect Process Changes That May Affect Product Quality

ABSTRACT Cellular metabolism plays a role in the observed variability of a drug substance's Critical Quality Attributes (CQAs) made by biomanufacturing processes. Therefore, here we describe a new approach for monitoring biomanufacturing processes that measures a set of metabolic reaction rates (named Critical Metabolic Parameters (CMP) in addition to the macroscopic process conditions currently being used as Critical Process Parameters (CPP) for biomanufacturing. Constraint‐based systems biology models like Flux Balance Analysis (FBA) are used to estimate metabolic reaction rates, and metabolic rates are used as inputs for multivariate Batch Evolution Models (BEM). Metabolic activity was reproducible among batches and could be monitored to detect a deliberately induced macroscopic process shift (i.e., temperature change). The CMP approach has the potential to enable “golden batches” in biomanufacturing processes to be defined from the internal metabolic activity and to aid in detecting process changes that may impact the quality of the product. Overall, the data suggested that monitoring of metabolic activity has promise for biomanufacturing process control.

Biotechnology & Applied Microbiology↗

Semisupervised Learning for Seismic Monitoring Applications

The impressive performance that deep neural networks demonstrate on a range of seismic monitoring tasks depends largely on the availability of event catalogs that have been manually curated over many years or decades. However, the quality, duration, and availability of seismic event catalogs vary significantly across the range of monitoring operations, regions, and objectives. Semisupervised learning (SSL) enables learning from both labeled and unlabeled data and provides a framework to leverage the abundance of unreviewed seismic data for training deep neural networks on a variety of target tasks. We apply two SSL algorithms (mean-teacher and virtual adversarial training) as well as a novel hybrid technique (exponential average adversarial training) to seismic event classification to examine how unlabeled data with SSL can enhance model performance. In general, we find that SSL can perform as well as supervised learning with fewer labels. We also observe in some scenarios that almost half of the benefits of SSL are the result of the meaningful regularization enforced through SSL techniques and may not be attributable to unlabeled data directly. Lastly, the benefits from unlabeled data scale with the difficulty of the predictive task when we evaluate the use of unlabeled data to characterize sources in new geographic regions. Finally, in geographic areas where supervised model performance is low, SSL significantly increases the accuracy of source-type classification using unlabeled data.

58 GEOSCIENCES↗

Television image compression and small animal remote monitoring

It was shown that a subject can reliably discriminate a difference in video image quality (using a specific commercial product) for image compression levels ranging from 384 kbits per second to 1536 kbits per second. However, their discriminations are significantly influenced by whether or not the TV camera is stable or moving and whether or not the animals are quiescent or active, which is correlated with illumination level (daylight versus night illumination, respectively). The highest video rate used here was 1.54 megabits per second, which is about 18 percent of the so-called normal TV resolution of 8.4MHz. Since this video rate was judged to be acceptable by 27 of the 34 subjects (79 percent), for monitoring the general health and status of small animals within their illuminated (lights on) cages (regardless of whether the camera was stable or moved), it suggests that an immediate Space Station Freedom to ground bandwidth reduction of about 80 percent can be tolerated without a significant loss in general monitoring capability. Another general conclusion is that the present methodology appears to be effective in quantifying visual judgments of video image quality.

Haines, Richard F.↗

Act as NARSTO Management Coordinator and Conduct Research In Support of NARSTO Activities

This grant funded the position of NARSTO Management Coordinator. NARSTO was a public-private partnership with members from government, utilities, industry, and academe in Canada, the United States and Mexico. NARSTO planed and coordinated independently sponsored projects and tasks designed to identify and resolve policy-relevant science questions related to a) Anthropogenic and biogenic air-pollution sources and emissions, b) The complex physical and chemical processes affecting the accumulation of pollutants in the troposphere (including greenhouse gases and aerosols), c) The potential of certain pollutants to react and generate oxidants and fine particles in the troposphere, d) The development, intercomparison, and application of atmospheric models, e) The development of monitoring studies and methodologies needed to assess emission control effectiveness for selected greenhouse gases and aerosols, air pollutants and their precursors, and f) The attainment of the national air-quality and climate-stabilization goals and standards established by each member Nation.

54 ENVIRONMENTAL SCIENCES↗

THE LICK AGN MONITORING PROJECT: RECALIBRATING SINGLE-EPOCH VIRIAL BLACK HOLE MASS ESTIMATES

We investigate the calibration and uncertainties of black hole (BH) mass estimates based on the single-epoch (SE) method, using homogeneous and high-quality multi-epoch spectra obtained by the Lick Active Galactic Nucleus (AGN) Monitoring Project for nine local Seyfert 1 galaxies with BH masses <10{sup 8} M{sub Sun }. By decomposing the spectra into their AGNs and stellar components, we study the variability of the SE H{beta} line width (full width at half-maximum intensity, FWHM{sub H{beta}} or dispersion, {sigma}{sub H{beta}}) and of the AGN continuum luminosity at 5100 A (L{sub 5100}). From the distribution of the 'virial products' ({proportional_to} FWHM{sub H{beta}}{sup 2} L{sup 0.5}{sub 5100} or {sigma}{sub H{beta}}{sup 2} L{sup 0.5}{sub 5100}) measured from SE spectra, we estimate the uncertainty due to the combined variability as {approx}0.05 dex (12%). This is subdominant with respect to the total uncertainty in SE mass estimates, which is dominated by uncertainties in the size-luminosity relation and virial coefficient, and is estimated to be {approx}0.46 dex (factor of {approx}3). By comparing the H{beta} line profile of the SE, mean, and root-mean-square (rms) spectra, we find that the H{beta} line is broader in the mean (and SE) spectra than in the rms spectra by {approx}0.1 dex (25%) for our sample with FWHM{sub H{beta}} <3000 km s{sup -1}. This result is at variance with larger mass BHs where the difference is typically found to be much less than 0.1 dex. To correct for this systematic difference of the H{beta} line profile, we introduce a line-width dependent virial factor, resulting in a recalibration of SE BH mass estimators for low-mass AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

The Additive Manufacturing Moment Measure (AM3) Approach to Predictions of Solid Cooling Rate and Time Above Melt

Qualification of a laser powder bed fusion additive manufacturing (LPBF-AM) process requires knowledge of the multi-scale material physics during the process, per part. As the LPBF-AM build occurs, each moment is influenced by the process history. Knowledge of the build sequence can be used to generate a discretized time-space-condition point field that when coupled with a nearest neighbors’ calculation results in a generalized and fully parallel process model computation. This GPU accelerated approach was developed for part-scale analysis of build files along with in-situ process monitoring sensor data and is termed the “Additive Manufacturing Moment Measure” (AM3). The AM3 approach will be presented and then used to evaluate an AM Bench relevant geometry with synchronized in-situ process data, ex-situ nondestructive evaluation, and optical microscopy observations. These comparisons permit a better understanding of how the process actions can affect the LPBF-AM build quality and the signals generated during in-situ process monitoring.

Additive Manufacturing↗

A prototype compton camera for in-vivo dosimetry of ion beam cancer irradiation

Three-dimensional in-vivo dose monitoring of ion beam cancer irradiation can improve the quality of treatment. For this purpose we investigate the feasibility of imaging the single photon emissions due to nuclear reactions of projectiles with target nuclei (in-beam SPECT). A suitable imaging technique in the energy range of the emitted gamma rays is the Compton camera. A prototype based on prior simulations is currently under construction. Te system comprises two CdZnTe cross-strip detectors with steering grid and depth-of-interaction capability and one segmented LSO scintillator crystal with modified Anger light readout. We present the concept of the system including the front-end and DAQ electronics as well as first measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Path Planning Automation Concept for Advanced Air Mobility

Advanced Air Mobility (AAM) aims to develop an air transportation system for novel air vehicles between local, regional, intraregional, and urban places. Safety and efficiency of increasingly complex AAM operations are expected to require extensive use of automation, ranging from controlling the revolutionary new aircraft to managing flights dynamically in the high tempo airspace and aerodrome operations. Both onboard and ground automation will play central roles in assisting AAM operators with managing the flight paths of their fleet. This document presents a concept for dynamic path planning (DPP) automation applicable to AAM and other flight operations. The role of the DPP automation system is fivefold: (1) it creates a flight path with desired qualities of being feasible, deconflicted, harmonized, flexible, and optimal; (2) it monitors the progress of flight in a dynamic operating environment; (3) it supports the user in evaluating continued acceptability of the flight path in changing conditions; (4) it revises the flight path as needed to maintain the desired flight path qualities; and (5) it coordinates the flight path with airspace users and service providers. Key users of the DPP automation system include flight planners, pilots, and airspace service providers The concept allows for the system to be installed onboard the aircraft as well as on the ground. The system responds automatically to the dynamic operating environment to ensure that a safe and operationally acceptable flight path is available throughout the flight.

Vivek Sharma↗

Thermographic process monitoring in powderbed based additive manufacturing

Selective Laser Melting is utilized to build metallic parts directly from CAD-Data by solidification of thin powder layers through application of a fast scanning laser beam. In this study layerwise monitoring of the temperature distribution is used to gather information about the process stability and the resulting part quality. The heat distribution varies with different kinds of parameters including scan vector length, laser power, layer thickness and inter-part distance in the job layout which in turn influence the resulting part quality. By integration of an off-axis mounted uncooled thermal detector the solidification as well as the layer deposition are monitored and evaluated. Errors in the generation of new powder layers usually result in a locally varying layer thickness that may cause poor part quality. For effect quantification, the locally applied layer thickness is determined by evaluating the heat-up of the newly deposited powder. During the solidification process space and time-resolved data is used to characterize the zone of elevated temperatures and to derive locally varying heat dissipation properties. Potential quality indicators are evaluated and correlated to the resulting part quality: Thermal diffusivity is derived from a simplified heat dissipation model and evaluated for every pixel and cool-down phase of a layer. This allows the quantification of expected material homogeneity properties. Maximum temperature and time above certain temperatures are measured in order to detect hot spots or delamination issues that may cause a process breakdown. Furthermore, a method for quantification of sputter activity is presented. Since high sputter activity indicates unstable melt dynamics this can be used to identify parameter drifts, improper atmospheric conditions or material binding errors. The resulting surface structure after solidification complicates temperature determination on the one hand but enables the detection of potential surface defects on the other hand. These issues and proper key figures for thermographic monitoring of the Selective Laser Melting process are discussed in the paper. Even though microbolometric temperature measurement is limited to repetition rates in the Hz-regime and sub megapixel resolution, current results show the feasibility of process surveillance by thermography for a limited section of the building platform in a commercial system.

42 ENGINEERING↗

Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

Cucinotta, Francis A.↗

The relevance of particle flux monitors in accelerator-based activation analysis

One of the most critical parameters in activation analysis is the flux density of the activating radiation, its spatial distribution in particular. The validity of the basic equation for calculating the activity induced to the exposed item depends upon the fulfilment of several conditions, the most relevant of them being equal doses of incident activating radiation received by the unknown sample, the calibration material and the reference material, respectively. This requirement is most problematic if accelerator-produced radiation is used for activation. Whilst nuclear research reactors usually are equipped with exposure positions that provide fairly homogenous activation fields for thermal neutron activation analysis accelerator-generated particle beams (neutrons, photons, charged particles) usually exhibit axial and, in particular, sharp radial flux gradients. Different experimental procedures have been developed to fulfil the condition mentioned above. In this paper, three variants of the application of flux monitors in photon activation analysis are discussed (external monitor, additive and inherent internal monitor). Experiments have indicated that the latter technique yields highest quality of the analytical results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Recursive Multiscale Correlation-Averaging Algorithm for an Automated Distributed Road Condition Monitoring System

A signal processing approach is proposed to jointly filter and fuse spatially indexed measurements captured from many vehicles. It is assumed that these measurements are influenced by both sensor noise and measurement indexing uncertainties. Measurements from low-cost vehicle-mounted sensors (e.g., accelerometers and Global Positioning System (GPS) receivers) are properly combined to produce higher quality road roughness data for cost-effective road surface condition monitoring. The proposed algorithms are recursively implemented and thus require only moderate computational power and memory space. These algorithms are important for future road management systems, which will use on-road vehicles as a distributed network of sensing probes gathering spatially indexed measurements for condition monitoring, in addition to other applications, such as environmental sensing and/or traffic monitoring. Our method and the related signal processing algorithms have been successfully tested using field data.

47 OTHER INSTRUMENTATION↗