Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Performance of a Cross-Flow Humidifier with a High Flux Water Vapor Transport Membrane

Water vapor transport (WVT) flux across a composite membrane that consists of a very thin perfluorosulfonic acid (PFSA) ionomer layer sandwiched between two expanded polytetrafluoroethylene (PTFE) microporous layers is investigated. Static and dynamic tests are conducted to measure WVT flux for different composite structures; a transport model shows that the underlying individual resistances for water diffusion in the gas phase and microporous and ionomer layers and for interfacial kinetics of water uptake at the ionomer surface are equally important under different conditions. A finite-difference model is formulated to determine water transport in a full-scale (2-m2 active membrane area) planar cross-flow humidifier module assembled using pleats of the optimized composite membrane. In agreement with the experimental data, the modeled WVT flux in the module increases at higher inlet relative humidity (RH) of the wet stream and at lower pressures, but the mass transfer effectiveness is higher at higher pressures. The model indicates that the WVT flux is highest under conditions that maintain the wet stream at close to 100% RH while preventing the dry stream from becoming saturated. The overall water transport is determined by the gradient in RH of the wet and dry streams but is also affected by vapor diffusion in the gas layer and the microporous layer.

combined thermal and mass transfer↗

ZnSe nanorods prepared in hydroxide-melts and their application as a humidity sensor

We have synthesized the crystalline ZnSe nanorods for the first time using the molten hydroxides as reaction solvent in the absence of organic dispersant or capping agents. The products are characterized by X-ray diffraction, field emission scanning electron microscopy, and transmission electron microscopy. The diameters of ZnSe nanorods are about 200-300 nm, and the lengths are about 1-2 {mu}m. Humidity sensors based on ZnSe nanorods are fabricated and their responsiveness to humidity on static and dynamic testing are investigated. The change of resistance is about three orders of magnitude as the relative humidity increases from 20% to 85%. The response time and recovery time is 50 s and 81 s versus the changes of relative humidity from 20% to 85% and from 85% to 20%, respectively. Our sensor offers higher sensitivity, as well as much better stability and reproducibility than the humidity sensor of ZnSe nanostructure reported before.

36 MATERIALS SCIENCE↗

Correlation of Structural Differences between Nafion/Polyaniline and Nafion/Polypyrrole Composite Membranes and Observed Transport Properties

Polyaniline/Nafion and polypyrrole/Nafion composite membranes, prepared by chemical polymerization, are studied by infrared and nuclear magnetic resonance spectroscopy, and scanning electron microscopy. Differences in vanadium ion diffusion through the membranes and in the membranes’ area specific resistance are linked to analytical observations that polyaniline and polypyrrole interact differently with Nafion. Polypyrrole, a weakly basic polymer, binds less strongly to the sulfonic acid groups of the Nafion membrane, and thus the hydrophobic polymer aggregates in the center of the Nafion channel rather than on the hydrophilic side chains of Nafion that contain sulfonic acid groups. This results in a drastically elevated membrane resistance and an only slightly decreased vanadium ion permeation compared to a Nafion membrane. Polyaniline on the other hand is a strongly basic polymer, which forms along the sidewalls of the Nafion pores and on the membrane surface, binding tightly to the sulfonic acid groups of Nafion. This leads to a more effective reduction in vanadium ion transport across the polyaniline/Nafion membranes and the increase in membrane resistance is less severe. The performance of selected polypyrrole/Nafion composite membranes is tested in a static vanadium redox cell. Increased coulombic efficiency, compared to a cell employing Nafion, further confirms the reduced vanadium ion transport through the composite membranes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dry Printing Pure Copper with High Conductivity and Adhesion for Flexible Electronics

Additive manufacturing of functional devices on various rigid and flexible substrates is rising rapidly due to their design flexibility, rapid manufacturing, and lower cost. Current printing technologies are ink-based and focused on printing silver (Ag) as conductive lines due to its matured ink formulation process, low sintering temperature, ease of printing, and low oxidation rate. However, Ag is the 68th most abundant element on Earth, while copper (Cu) is the 25th, making it much cheaper (>100×) while having a comparable conductivity to Ag. Therefore, printing Cu has become technologically and economically more attractive than Ag. Nevertheless, Cu printing is still a significant challenge in ink-based printing methods due to the higher sintering temperature relative to the glass-transition temperature of most flexible substrates, the higher oxidation rate, the challenging ink formulation process, and ink stability concerns. Here, we demonstrate printing highly conductive Cu on flexible polyimide substrates using a dry printing technique. Cu nanoparticles (~3–30 nm) are generated by on-demand laser ablation of a solid Cu target inside the printer head and under argon background gas. These Cu nanoparticles are then transported through a nozzle and onto the substrate, where they are laser-sintered in real time. The argon gas plays three critical roles in laser plume condensation for nanoparticle generation, transport, and sheath gas to avoid oxidation during sintering. The sintered nanoparticles thus show high electrical conductivity and mechanical stability under static and cyclic tests. Our dry printing technique can potentially revolutionize how electronic devices and sensors are additively manufactured for earth and space applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Activity gradient driven mass transport in molten fluoride salt medium

Abstract The molten salt-cooled reactor concept has garnered significant interest and one of the current challenges limiting the deployment of these reactor concepts is the complex corrosion phenomenon observed in molten salt environments. One of these phenomena is activity gradient mass transport, which has been shown to affect dissimilar materials submerged in the same salt medium even when best efforts have been made to electrically isolate dissimilar materials from one another. This mechanism while shown experimentally, has not been predictively studied through a modeling approach. In this study, activity gradients in several 316L-X materials systems have been modeled and the mass transport predicted by the model has been confirmed through static isothermal corrosion testing in a molten fluoride salt medium.

36 MATERIALS SCIENCE↗

Scheme for measuring experimentally the velocity of pilot waves and the discreteness of time

We consider the following two questions. Suppose that a quantum system suffers a change of the boundary condition or the potential at a given space location. Then (1)when will the wavefunction shows a response to this change at another location? And (2)how does the wavefunction changes?The answer to question (1) could reveal how a quantum system gets information on the boundary condition or the potential. Here we show that if the response takes place immediately, then it can allow superluminal signal transfer. Else if the response propagates in space with a finite velocity, then it could give a simple explanation why our world shows classicality on the macroscopic scale. Furthermore, determining the exact value of this velocity can either clarify the doubts on static experiments for testing Bell's inequality, or support the pilot-wave interpretation of quantum mechanics. We propose a feasible experimental scheme for measuring this velocity, which can be implemented with state-of-art technology, e.g., single-electron biprism interferometry.Question (2) is studied with a square-well potential model, and we find a paradox between the impossibility of superluminal signal transfer and the normalization condition of wavefunctions. To solve the paradox, we predict that when a change of the potential occurs at a given space location, the system will show no response to this change at all, until after a certain time interval. Otherwise either special relativity or quantum mechanics will be violated. As a consequence, no physical process can actually happen within Planck time. Therefore it gives a simple proof that time is discrete, with Planck time being the smallest unit. Combining with the answer to question (1), systems with a larger size and a slower velocity could have a larger unit of time, making it possible to test the discreteness of time experimentally. Our result also sets a limit on the speed of computers, and gives instruction to the search of quantum gravity theories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial ({approx}2 {mu}m) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Composite arrays of superconducting microstrip line resonators

A novel design of an array of half-wave superconductive microstrip resonators is described. The resonator is intended to be useful for electron spin resonance studies of thin film samples at cryogenic temperatures. It achieves a high quality factor, has a small mode-volume, and creates a uniform magnetic field in a plane above the resonator. The device is made of thin film Niobium on sapphire wafer and is tested with a static magnetic field. Variation of Q-factor versus the magnetic field's strength at different temperatures is reported and is in a good agreement with simulation when the loss due to the vortices is included. Also, the power-dependence response of the resonator is shown in experiments and is verified by capturing the nonlinearity associated with the surface impedance of the superconducting film into the circuit model of the device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ejected particle size measurement using Mie scattering in high explosive driven shockwave experiments

In this paper, we report on the development of a diagnostic to provide constraints on the size of particles ejected from shocked metallic surfaces. The diagnostic is based on measurements of the intensity of laser light transmitted through a cloud of ejected particles as well as the angular distribution of scattered light, and the analysis of the resulting data is done using the Mie solution. Finally, we describe static experiments to test our experimental apparatus and present initial results of dynamic experiments on Sn targets. Improvements for future experiments are briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crash simulation of UNS electric vehicle under frontal front impact

Sebelas Maret University has been developing an Electric Vehicle namely SmarT-EV UNS. The main structure of the car are chasis and body. The chasis is made from steel and the body is made from fiberglass composite. To ensure the safety of the car, both static and dynamic tests were carried out to these structures, including their materials, like: tensile test, bending test, and impact test. Another test needed by this vehicle is crashworthiness test. To perform the test, it is needed complex equipments and it is quite expensive. Another way to obtain vehicle crashworthiness behaviour is by simulate it. The purpose of this study was to simulate the response of the Smart-EV UNS electric vehicle main structure when crashing rigid barrier from the front. The crash simulation was done in according to the NHTSA (National Highway Traffic Safety Administration) within the speed of the vehicle of 35 mph. The UNS Electric Vehicle was modelled using SolidWorks software, and the simulation process was done by finite element method using ANSYS software. The simulation result showed that the most internal impact energy was absorbed by chassis part. It absorbed 76.2% of impact energy, then the base absorbed 11.3 %, while the front body absorbed 2.5 %, and the rest was absorbed by fender, hood, and other parts.

42 ENGINEERING↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

Molecular fouling resistance of zwitterionic and amphiphilic initiated chemically vapor-deposited (iCVD) thin films

Biofouling is a universal problem in various applications ranging from water purification to implantable biomedical devices. Recent advances in surface modification have created a rich library of antifouling surface chemistries, many of which can be categorized into one of the two groups: hydrophilic surfaces or amphiphilic surfaces. We report the straightforward preparation of antifouling thin film coatings in both categories via initiated chemical vapor deposition. A molecular force spectroscopy-based method is demonstrated as a rapid and quantitative assessment tool for comparing the differences in antifouling characteristics. The fouling propensity of single molecules, as opposed to bulk protein solution or bacterial culture, is assessed. This method allows for the interrogation of molecular interaction without the complication resulted from protein conformational change or micro-organism group interactions. The molecular interaction follows the same trend as bacterial adhesion results obtained previously, demonstrating that molecular force probe is a valid method for the quantification and mechanistic examination of fouling. In addition, the molecular force spectroscopy-based method is able to distinguish differences in antifouling capability that is not resolvable by traditional static protein adsorption tests. To lend further insight into the intrinsic fouling resistance of zwitterionic and amphiphilic surface chemistries, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, advancing and receding water contact angles, and atomic force microscopy are used to elucidate the film properties that are relevant to their antifouling capabilities.

Yang, R↗

Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector

The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.

maximum likelihood, radiation detectors, neutron d↗

effect of the parameters of AlN/GaN/AlGaN and AlN/GaN/InAlN heterostructures with a two-dimensional electron gas on their electrical properties and the characteristics of transistors on their basis

The effect of the layer thickness and composition in AlGaN/AlN/GaN and InAlN/AlN/GaN transistor heterostructures with a two-dimensional electron gas on their electrical and the static parameters of test transistors fabricated from such heterostructures are experimentally and theoretically studied. It is shown that the use of an InAlN barrier layer instead of AlGaN results in a more than twofold increase in the carrier concentration in the channel, which leads to a corresponding increase in the saturation current. In situ dielectric-coating deposition on the InAlN/AlN/GaN heterostructure surface during growth process allows an increase in the maximum saturation current and breakdown voltages while retaining high transconductance.

36 MATERIALS SCIENCE↗

FIC Vulnerability Profile

The FIC team is engaged with Pacific Northwest National Laboratory’s (PNNL’s) Shamrock Cyber Team to provide cybersecurity analyses of the FIC software. Shamrock offers both Threat-Based Analysis services and Secure Software Development services. These services are ultimately used to understand and mitigate threats against software and to reduce vulnerabilities in software, thus improving overall cybersecurity and informing decision makers. Shamrock’s Secure Software Development services, specifically Static Analysis Security Testing (SAST) and Open-Source Analysis (OSA), produced this Vulnerability Profile.

97 MATHEMATICS AND COMPUTING↗

Structural Characterization of Deployed Thermoplastic and Thermoset Composite Tidal Turbine Blades

The National Renewable Energy Laboratory worked with Verdant Power to manufacture, and characterize, novel thermoplastic composite blades on their Gen5d 5 m diameter turbines at the Roosevelt Island Tidal Energy (RITE) site in the East River in N.Y. to demonstrate a low-cost manufacturing process for marine energy structures. Verdant had designed, manufactured, and deployed epoxy thermoset composite blades on three Gen5d turbines in October 2020. At a maintenance cycle in May 2021, a Gen5d turbine equipped with the NREL thermoplastic blades was deployed and retrieved in October 2021. Modal, static and fatigue structural characterization was performed on both blade types before and after the deployment. The static and modal test results showed that the thermoplastic blades were slightly stiffer than the epoxy blades both dry and after the deployment. The epoxy blades had about 8% increase in strain at the applied load after the deployment, whereas the thermoplastic blade strains were not changed significantly. Ultimately the thermoplastic blade failed during fatigue testing due to a crack which is thought to have initiated between the internal foam and the laminate at the location of the internal instrumentation. The Verdant Power Gen5d epoxy blades did not have this internal instrumentation and did not have this failure, performing adequately through the operational period. A lack of design information and fatigue data for both the thermoplastic laminates and the adhesive used means that further work is needed to fully understand his failure and the root cause analysis is ongoing. This paper provides details on the thermoplastic blade manufacturing, materials, test methodology and results.

17 WIND ENERGY↗

TEAMER Technical Support on Biofouling and Corrosion for E-Wave Technologies LLC Novel (Abstract)

National Technology & Engineering Solutions of Sandia (NTESS) in collaboration with the Pacific Northwest National Laboratory (PNNL), and with guidance from E-Wave, will assess corrosion and biofouling challenges specific to E-Wave’s innovative WEC designed to retrofit into and power existing aquaculture farm infrastructure from ocean waves. The teams will examine coatings via a static raw seawater test and determine the efficacy of coatings for E-Wave’s applications. Samples will include panels of materials provided by E-Wave and coated with three different paint treatments. Fouling will be determined using a staining technique followed by photographic analysis to evaluate fouling intensity on the surface. Materials will also be weighed before and after submersion to facilitate weight change analysis resulting from fouling organisms aggregating on the materials.

16 TIDAL AND WAVE POWER↗

FY25 Cellular Silicone Foam Friction Testing Summary Report

This effort was a collaboration between LANL groups MPA-CINT, E-13, and V-14 to characterize various properties of foam materials for programmatic work. Specifically, MPA-CINT staff members’ contribution to this effort was to perform friction testing of cellular silicone foams of two different porosities with respect to two engineering materials with predefined surface roughnesses. The selected foams (henceforth serving as the sled material interface exposed to motion) had porosities of 67% and 70% with respect to fabricated values. The other materials used in the friction testing measurement couple (static track material) were 304 Stainless Steel (304 SS) and Very High-Temperature Glass-Mica Ceramic, known as Macor®.

36 MATERIALS SCIENCE↗