Validation of CTF Models Using NRC Data from RBHT Reflood Experiments
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
For the development of heat-pipe cooled microreactors, it is crucial to thoroughly understand the characteristics and functioning of heat pipes across a wide spectrum of operating conditions. Passive heat removal and its long-term performance stability are critical factors in this context. Enhanced experimental data is vital for evaluating the operational lifespan of alkali metal heat pipes. Idaho National Laboratory (INL) has successfully conducted an extended duration test on a high-performance sodium-filled heat pipe, closely monitoring the axial temperature profile, power supplied by the heaters, and heat removed by a gas-gap calorimeter. The results from this testing provide valuable data that are instrumental in supporting heat pipe validation efforts. Specifically, this data aids in the development and validation of Sockeye, the Multiphysics Object-Oriented Simulation Environment (MOOSE) tool under the US-DOE NEAMS program designed for heat pipe modeling. By comparing experimental results with Sockeye’s predictions, the tool's accuracy and reliability can be assessed and improved, thereby enhancing its capability to simulate heat pipe operations under various conditions.
During the course of the last decade, AREVA NP has developed Computational Fluid Dynamics (CFD) methods capable of accurately predicting flow fields and thermal mixing within fuel bundles, as well as pressure losses and hydrodynamic forces on fuel assembly components such as spacer grids, lower and upper nozzles. The present work summarizes the evolution of AREVA NP's single-phase CFD methodology and the extensive validation efforts, with focus on improving confidence level in CFD results. Currently, it is possible to produce models for large sections of a fuel assembly and produce CFD simulation results with an uncertainty proven to be similar to the corresponding measurement uncertainty. Extensive validation has been conducted against in-house data obtained for a wide range of geometries representative of actual hardware, in multiple test facilities, with various measurement techniques. In addition to in-house validation data, AREVA NP has also exercised its best-practices against international benchmarks; blind test results were in very good agreement with the data. The current high level of confidence in single-phase CFD predictions allows investigating a wide variety of physics in Pressurized Water Reactor (PWR) as well as Boiling Water Reactor (BWR) fuel assemblies. CFD is used as a design and optimization tool as well as a supplement to regular testing to improve the quality of tests and optimize hardware design features for specific targets. CFD played a major role in the design of AREVA NP's latest fuel assembly designs (ATRIUM{sup TM1} 11 and GAIA). In this paper we first illustrate AREVA NP's comprehensive validation database for single-phase CFD (pressure drop, flow field), then provide several examples of applications: virtual testing for parts optimization and support of core operation. (authors)
We describe the concept, technical realisation and validation of a largely data-driven method to model events with Z→ττ decays. In Z→μμ events selected from proton-proton collision data recorded at √s=8 TeV with the ATLAS experiment at the LHC in 2012, the Z decay muons are replaced by τ leptons from simulated Z →ττ decays at the level of reconstructed tracks and calorimeter cells. The τ lepton kinematics are derived from the kinematics of the original muons. Thus, only the well-understood decays of the Z boson and τ leptons as well as the detector response to the τ decay products are obtained from simulation. All other aspects of the event, such as the Z boson and jet kinematics as well as effects from multiple interactions, are given by the actual data. This so-called τ-embedding method is particularly relevant for Higgs boson searches and analyses in ττ final states, where Z→ττ decays constitute a large irreducible background that cannot be obtained directly from data control samples. In this paper, we discuss the relevant concepts based on the implementation used in the ATLAS Standard Model H→ττ analysis of the full datataset recorded during 2011 and 2012.
The predicted radiation gamma dose rate is a key parameter to determine if a spent nuclear fuel assembly is self-protected from misuse as well as an indicator for worker/inspector safety. Recent studies showed that using state-of-the-art techniques for dose rate calculations, including the one adopted for this study, the numerical calculations of the gamma dose rates are three times lower than those from the most commonly-cited reference values for spent LWR fuel used by domestic and international agencies. With only a few publically available experimental data points worldwide for this type of benchmark study, the gamma flux measurements from the Spent Fuel Non Destructive Assay (NDA) measurement campaign can be used to help validate the physics approach used in calculating gamma dose rates. Specifically, this data would validate the gamma flux calculation from spent fuel, which is a key component of these multi-physics techniques for dose rate assessments; dose rate measurements were not part of the NDA campaign. These data are primarily the passive gamma measurements of the spent nuclear fuel assemblies from the Swedish Nuclear Fuel and Waste Management Company (SKB).
The CTH multiphysics hydrocode, which is used for a wide range of important calculations, has undertaken in recent years to overhaul its software quality and testing processes. A key part of this effort entailed building a new, robust V&V test suite made up of traditional hydrocode verification problems, such as those listed in the ASC Tri-Lab Test Suite and the Enhanced Tri-Lab Test Suite, as well as validation problems for some of CTHs most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards this goal was made in FY19. In FY20, this test suite has been expanded to include verification and validation tests of the Sesame and JWL equation of state models as well as the Mader verification problem from the Tri-Lab Test Suite and the Blake verification problem - a linear elastic analog to the Hunter problem from the Enhanced Tri-Lab Test Suite. This report documents CTH performance on the new test suite problems. Verification test results are compared to analytic solutions and, for most tests, convergence results are presented. Validation test results are compared to experimental data and mesh refinement studies are included. CTH performs well overall on the new test problems. Convergence rates for the Blake and Mader problems are comparable to those for similar ASC codes. The JWL and Sesame verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data for the Sesame and JWL equations of state for the materials tested. Future V&V work will focus on adding tests for other key capabilities like fracture and high explosive models.
A key step limiting how fast batteries can be deployed is the time necessary to provide evaluation and validation of performance. Using data analysis approaches, such as machine learning, the validation process can be accelerated. However, questions on the validity of projecting models trained on limited data or simple cycling profiles, such as constant current cycling, to real-world scenarios with complex loads remains. Here, we present the ability to predict performance with less than 1.2% mean absolute percent error when trained on cells aged using complex electric vehicle discharge profiles, and either AC Level 2 charge or DC Fast charge profiles, using only the first 45 cycles, namely 5% of the total testing time. While error is low across the projections, this study also highlights that battery lifetime analysis using only cycling data may not extrapolate safely to certain real-world conditions due to the impact of calendar degradation.
This paper presents an alternative method based on causal inference to perform validation, verification, and calibration of simulation models. While classical validation and verification approaches focus on the identification of the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on the identification of causal relationships between data elements. Statistical and machine learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between datasets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, then the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles it is known as a directed acyclic graph (DAG). A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and from experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts have a means to identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.
Recent drinking water regulations have imposed the need for per- and polyfluoroalkyl substances (PFAS) remediation. In response, treatment facilities may be required to retrofit existing treatment schemes to treat PFAS below maximum contaminant levels (MCLs). Adsorption technologies such as granular activated carbon (GAC) and ion exchange (IX) have been demonstrated to be effective; however, there are limited techno-economic metrics available which provide guidance on technology selection and design for diverse PFAS-containing source water conditions. Process systems engineering (PSE) tools which can traditionally perform these analyses are hindered by the data availability, model validity, and understanding of treatment phenomena for emerging contaminants. This work employs published data regressions, statistical models, process models, techno-economic analyses, and other process systems tools in a model-based uncertainty framework to consider the limitations of emerging contaminant research. Through this analysis framework, economic results are provided as probabilistic distributions based on the uncertainty of the models and diverse conditions that treatment facilities experience.
A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the large data production and flow. The system design is based on the layered structure scalable to the future extension to accommodate increasing data demands. Software architecture that allows a web-based monitoring of the operation status, remote experiment, and data analysis is discussed. The operating software will help machine operators and users validate the acquired data promptly, prepare next discharge, and enhance the experiment performance and data analysis in a distributed environment.
In this study we develop an a priori method for simulating dynamic resonant frequency and temperature responses in a radio frequency quadrupole (RFQ) and its associated water-based cooling system respectively. Our model provides a computationally efficient means to evaluate the transient response of the RFQ over a large range of system parameters. The model was constructed prior to the delivery of the PIP-II Injector Test RFQ and was used to aid in the design of the water-based cooling system, data acquisition system, and resonance control system. Now that the model has been validated with experimental data, it can confidently be used to aid in the design of future RFQ resonance controllers and their associated water-based cooling systems. Finally, without any empirical fitting, it has demonstrated the ability to predict absolute temperature and frequency changes to 11% accuracy on average, and relative changes to 7% accuracy.
Purpose: To develop and validate a Monte Carlo (MC) model of a Phillips RT-250 orthovoltage unit to test various beam spectrum modulation strategies for in vitro/vivo studies. A model of this type would enable the production of unconventional beams from a typical orthovoltage unit for novel therapeutic applications such as gold nanoparticle-aided radiotherapy. Methods: The MCNP5 code system was used to create a MC model of the head of RT-250 and a 30 × 30 × 30 cm{sup 3} water phantom. For the x-ray machine head, the current model includes the vacuum region, beryllium window, collimators, inherent filters and exterior steel housing. For increased computational efficiency, the primary x-ray spectrum from the target was calculated from a well-validated analytical software package. Calculated percentage-depth-dose (PDD) values and photon spectra were validated against experimental data from film and Compton-scatter spectrum measurements. Results: The model was validated for three common settings of the machine namely, 250 kVp (0.25 mm Cu), 125 kVp (2 mm Al), and 75 kVp (2 mm Al). The MC results for the PDD curves were compared with film measurements and showed good agreement for all depths with a maximum difference of 4 % around dmax and under 2.5 % for all other depths. The primary photon spectra were also measured and compared with the MC results showing reasonable agreement between the two, validating the input spectra and the final spectra as predicted by the current MC model. Conclusion: The current MC model accurately predicted the dosimetric and spectral characteristics of each beam from the RT-250 orthovoltage unit, demonstrating its applicability and reliability for beam spectrum modulation tasks. It accomplished this without the need to model the bremsstrahlung xray production from the target, while significantly improved on computational efficiency by at least two orders of magnitude. Supported by DOD/PCRP grant W81XWH-12-1-0198.
Here we report the outcome of the application of the Nuclear Regulatory Commission (NRC) Phenomena Identification and Ranking Table (PIRT) process to the issue of nuclear-grade graphite for the moderator and structural components of a next generation nuclear plant (NGNP), considering both routine (normal operation) and postulated accident conditions for the NGNP. The NGNP is assumed to be a modular high-temperature gas-cooled reactor (HTGR), either a gas-turbine modular helium reactor (GTMHR) version [a prismatic-core modular reactor (PMR)] or a pebble-bed modular reactor (PBMR) version [a pebble bed reactor (PBR)] design, with either a direct- or indirect-cycle gas turbine (Brayton cycle) system for electric power production, and an indirect-cycle component for hydrogen production. NGNP design options with a high-pressure steam generator (Rankine cycle) in the primary loop are not considered in this PIRT. This graphite PIRT was conducted in parallel with four other NRC PIRT activities, taking advantage of the relationships and overlaps in subject matter. The graphite PIRT panel identified numerous phenomena, five of which were ranked high importance-low knowledge. A further nine were ranked with high importance and medium knowledge rank. Two phenomena were ranked with medium importance and low knowledge, and a further 14 were ranked medium importance and medium knowledge rank. The last 12 phenomena were ranked with low importance and high knowledge rank (or similar combinations suggesting they have low priority). The ranking/scoring rationale for the reported graphite phenomena is discussed. Much has been learned about the behavior of graphite in reactor environments in the 60-plus years since the first graphite rectors went into service. The extensive list of references in the Bibliography is plainly testament to this fact. Our current knowledge base is well developed. Although data are lacking for the specific grades being considered for Generation IV (Gen IV) concepts, such as the NGNP, it is fully expected that the behavior of these graphites will conform to the recognized trends for near isotropic nuclear graphite. Thus, much of the data needed is confirmatory in nature. Theories that can explain graphite behavior have been postulated and, in many cases, shown to represent experimental data well. However, these theories need to be tested against data for the new graphites and extended to higher neutron doses and temperatures pertinent to the new Gen IV reactor concepts. It is anticipated that current and planned future graphite irradiation experiments will provide the data needed to validate many of the currently accepted models, as well as providing the needed data for design confirmation.
Over the past few years, the CTH multiphysics hydrocode has overhauled its software quality and testing processes, implementing current best practices in software quality and building a robust V&V test suite comprised of traditional hydrocode verification problems, including ASC Tri-Lab Test Suite and Enhanced Tri-Lab Test Suite problems, as well as validation problems for some of CTH’s most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards building this new test suite was made in FY19 and FY20. In FY21, the test suite has been expanded to include verification and validation tests of the Steinberg-Guinan-Lund (ST) viscoplastic model and the Johnson Cook (JFRAC) fracture model. Additionally, two new verification tests were added, covering hydrodynamics and high explosive (HE) modeling capabilities: the Kidder Gaussian density problem and the Escape of HE Products (EHEP) problem from the Tri-Lab Test Suite. This report discusses each of these test problems in detail. Verification test results are compared to analytic solutions. Validation test results are compared to experimental data. Wherever possible, convergence or mesh refinement studies are included. Additionally, while implementing the Kidder verification problem, a bug was identified that affects the use of tables to initialize pressure or density in 1D or 2D calculations. A brief discussion of the bug and its fix is included. CTH demonstrates good performance overall on the new test suite problems. Simulation results showed good agreement with analytic solutions for the Kidder problem, with convergence rates ranging between 1.8 and sub-linear, and relatively good agreement for the EHEP problem, though convergence rates for pressure and density were nearly 0. The ST and JFRAC strain rate loading verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data, including Taylor rod impact testing, for the materials tested. Future V&V work will focus on adding 2D and 3D versions of existing verification tests as well as adding validation tests of other frequently used capabilities such as other fracture models.
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for analysis of aldicarb, bromadiolone, carbofuran, oxamyl, and methomyl in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS666. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in MS666 for analysis of carbamate pesticides in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS666 can be determined.
Purpose: A prognostic index for survival was constructed and validated from patient data from two European Organisation for Research and Treatment of Cancer (EORTC) radiation trials for low-grade glioma (LGG). We sought to independently validate this prognostic index with a separate prospectively collected data set (Intergroup 86-72-51). Methods and Materials: Two hundred three patients were treated in a North Central Cancer Treatment Group-led trial that randomized patients with supratentorial LGG to 50.4 or 64.8 Gy. Risk factors from the EORTC prognostic index were analyzed for prognostic value: histology, tumor size, neurologic deficit, age, and tumor crossing the midline. The high-risk group was defined as patients with more than two risk factors. In addition, the Mini Mental Status Examination (MMSE) score, extent of surgical resection, and 1p19q status were also analyzed for prognostic value. Results: On univariate analysis, the following were statistically significant (p < 0.05) detrimental factors for both progression-free survival (PFS) and overall survival (OS): astrocytoma histology, tumor size, and less than total resection. A Mini Mental Status Examination score of more than 26 was a favorable prognostic factor. Multivariate analysis showed that tumor size and MMSE score were significant predictors of OS whereas tumor size, astrocytoma histology, and MMSE score were significant predictors of PFS. Analyzing by the EORTC risk groups, we found that the low-risk group had significantly better median OS (10.8 years vs. 3.9 years, p < 0.0001) and PFS (6.2 years vs. 1.9 years, p < 0.0001) than the high-risk group. The 1p19q status was available in 66 patients. Co-deletion of 1p19q was a favorable prognostic factor for OS vs. one or no deletion (median OS, 12.6 years vs. 7.2 years; p = 0.03). Conclusions: Although the low-risk group as defined by EORTC criteria had a superior PFS and OS to the high-risk group, this is primarily because of the influence of histology and tumor size. Co-deletion of 1p19q is a prognostic factor. Future studies are needed to develop a more refined prognostic system that combines clinical prognostic features with more robust molecular and genetic data.
The System Analysis Module (SAM) is currently under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for safety analyses of advanced non-light water reactors. This report presents a recent effort to validate the capability of SAM to predict the frictional pressure drop through pebble beds. Selected experimental data were used for code validation, including data from test facilities at Texas A&M University, Missouri University of Science and Technology, and North-West University of South Africa. SAM implements three empirical correlations to predict frictional pressure drop: the classical Ergun correlation; the KTA correlation, which is widely used in high-temperature gas-cooled reactor applications; and the Eisfeld and Schnitzlein correlation, which explicitly considers wall effect. Code validation was performed using all three correlations. For all selected experimental data, the KTA correlation shows the best performance and agrees very well with experimental measurement; the Eisfeld and Schnitzlein correlation, explicitly considering wall effects, shows acceptable accuracy, while there is no evidence that it is better than the KTA correlation; the Ergun correlation, however, over-predicts frictional pressure drop for most selected data points.
Economic factors and experimental limitations often lead to sparse and/or imprecise data used for the calibration and validation of computational models. This paper addresses resource allocation for calibration and validation experiments, in order to maximize their effectiveness within given resource constraints. When observation data are used for model calibration, the quality of the inferred parameter descriptions is directly affected by the quality and quantity of the data. This paper characterizes parameter uncertainty within a probabilistic framework, which enables the uncertainty to be systematically reduced with additional data. The validation assessment is also uncertain in the presence of sparse and imprecise data; therefore, this paper proposes an approach for quantifying the resulting validation uncertainty. Since calibration and validation uncertainty affect the prediction of interest, the proposed framework explores the decision of cost versus importance of data in terms of the impact on the prediction uncertainty. Often, calibration and validation tests may be performed for different input scenarios, and this paper shows how the calibration and validation results from different conditions may be integrated into the prediction. Then, a constrained discrete optimization formulation that selects the number of tests of each type (calibration or validation at given input conditions) is proposed. Furthermore, the proposed test selection methodology is demonstrated on a microelectromechanical system (MEMS) example.