Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Increased Efficiency in SI Engine with Air Replaced by Oxygen in Argon Mixture

Basic engine thermodynamics predicts that spark ignited engine efficiency is a function of both the compression ratio of the engine and the specific heat ratio of the working fluid. In practice the compression ratio of the engine is often limited due to knock. Both higher specific heat ratio and higher compression ratio lead to higher end gas temperatures and increase the likelihood of knock. In actual engine cycles, heat transfer losses increase at higher compression ratios and limit efficiency even when the knock limit is not reached. In this paper we investigate the role of both the compression ratio and the specific heat ratio on engine efficiency by conducting experiments comparing operation of a single-cylinder variable-compression-ratio engine with both hydrogen-air and hydrogen-oxygen-argon mixtures. For low load operation it is found that the hydrogen-oxygen-argon mixtures result in higher indicated thermal efficiencies. Peak efficiency for the hydrogen-oxygen-argon mixtures is found at compression ratio 5.5 whereas for the hydrogen-air mixture with an equivalence ratio of 0.24 the peak efficiency is found at compression ratio 13. We apply a three-zone model to help explain the effects of specific heat ratio and compression ratio on efficiency. Operation with hydrogen-oxygen-argon mixtures at low loads is more efficient because the lower compression ratio results in a substantially larger portion of the gas to reside in the adiabatic core rather than in the boundary layer and in the crevices, leading to less heat transfer and more complete combustion.

30 DIRECT ENERGY CONVERSION↗

Iodine solid sorbent design: a literature review of the critical criteria for consideration

Designing sorbents for iodine capture in different conditions requires selection and optimization of a large and diverse range of variables. These variables fall into general categories (or features) of sorbent activity, sorbent stability, and the fate of the loaded material in terms of the disposal (waste form) options available. To illustrate, silver-loaded, high-porosity sorbents make for maximized iodine capture and less pressure drop in a column-based sorption system approach, however, this high porosity can lead to less mechanically stable sorbents. Additionally, waste forms containing silver must also be compliant with additional criteria for hazardous waste disposal. Thus, all these aspects must be considered simultaneously when selecting a sorbent for utilization under specific conditions. Information is given for different types of sorbent design considerations for different operating conditions and some emphasis is also given on promising alternatives for silver as the active (chemisorption-based) getter metal. Discussion is given around demonstrated options for waste forms for different metal-iodide compounds.

36 MATERIALS SCIENCE↗

Field Testing of a Hierarchical Model-Free Transactive Control Strategy in a Residential House

Demand response plays an important role in addressing the uncertain, intermittent, and variable nature of renewable energy sources. However, to be effective, it requires a significant amount of demand load flexibility, in which buildings are important flexible assets for electricity systems. In this regard, many transactive control tools have been developed to harness this demand flexibility. Yet, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a field implementation and testing of a hierarchical model-free transactive control strategy using residential building thermostatically controlled loads. The transactive control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. Experimental field-testing results are provided to demonstrate the effectiveness of the proposed transactive control strategy.

Olama, Mohammed M.↗

Using Electric Vehicles to Mitigate Imbalance Requirements Associated with an Increased Penetration of Wind Generation

The integration of variable renewable generation sources continues to be a significant area of focus for power system planning. Renewable portfolio standards and initiatives to reduce the dependency on foreign energy sources drive much of the deployment. Unfortunately, renewable energy generation sources like wind and solar tend to be highly variable in nature. To counter the energy imbalance caused by this variability, wind generation often requires additional balancing resources to compensate for the variability in the electricity production. With the expected electrification of transportation, electric vehicles may offer a new load resource for meeting all, or part, of the imbalance created by the renewable generation. This paper investigates a regulation-services-based battery charging method on a population of plug-in hybrid electric vehicles to meet the power imbalance requirements associated with the introduction of 11 GW of additional wind generation into the Northwest Power Pool. It quantifies the number of vehicles required to meet the imbalance requirements under various charging assumptions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Energy Storage and its Potential Applications in Solar Thermal Power Plants and Electricity Storage

With the rapid growth of renewable power generation, economically storing large quantities of solar- and wind-generated electricity may become as important as renewable power itself. The combination of renewable power generation and energy storage can overcome the variability of renewable power generation alone and create the opportunity for renewable generation to provide base-load electricity.For peak power usage, the integration of renewable power and storage of excess electricity has several significant and positive impacts: expanding the renewable energy portion of total electricity generation, improving the peak-load response, and coordinating the electricity supply and demand over the grid. Several energy storage approaches exist, with mechanical, chemical, and electricalmethods either in use now or being developed. Comparing their efficiencies as well as their economic uses for different scales and applications helps determine the right technology for the right purpose. This paper will study the possibility of using thermal energy storage as a means for electricity storage, and compare it to other energy storage methods including batteries, flywheels, compressed air, and pumped hydropower.

14 SOLAR ENERGY↗

Transforming Drainage Research Data (USDA-NIFA Award No. 2015-68007-23193)

This dataset contains research data compiled by the “Managing Water for Increased Resiliency of Drained Agricultural Landscapes” project a.k.a. Transforming Drainage. This project was funded from 2015-2021 by the United States Department of Agriculture, National Institute of Food and Agriculture (USDA-NIFA, Award No. 2015-68007-23193). Data are also available from a separate web-accessible application (drainagedata.org). At drainagedata.org, users can visualize the data with customized tools, query based on specific sites and measurements of interest, and access site photographs, maps, summaries, and publications. Additional data or edits made following the publication of this data here at USDA NAL Ag Data Commons will be posted under the Versions tab on drainagedata.org. These data began in 1996 and include plot- and field-level measurements for 39 experiments across the Midwest and North Carolina. Practices studied include controlled drainage, drainage water recycling, and saturated buffers. In total, 219 variables are reported and span 207 site-years for tile drainage, 154 for nitrate-N load, 181 for water quality, 92 for water table, and 201 for crop yield.

Modeling↗

DuraLith Alkali-Aluminosilicate Geopolymer Waste Form Testing for Hanford Secondary Waste

The primary objective of the work reported here was to develop additional information regarding the DuraLith alkali aluminosilicate geopolymer as a waste form for liquid secondary waste to support selection of a final waste form for the Hanford Tank Waste Treatment and Immobilization Plant secondary liquid wastes to be disposed in the Integrated Disposal Facility on the Hanford Site. Testing focused on optimizing waste loading, improving waste form performance, and evaluating the robustness of the waste form with respect to waste variability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WECC Variable Generation Planning Reference Book: Appendices

The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

Makarov, Yuri V.↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review and Status of Wind Integration and Transmission in the United States. Key Issues and Lessons Learned

The objective in electric power system operation is to use generation and transmission resources within organizational constraints and operational rules and regulations to reliably and costeffectively balance load and generation. To meet this objective, system operational practices have been created to accommodate the innate variability and uncertainty that comes from a variety of sources, such as uncertainty of demand forecasts, whether a specific generating unit will be available when called upon, the variability of demand from many different types of customers, and others. As more wind power is connected to the power system, operating experiences acquired during the past several years have generally confirmed the findings of wind integration studies: wind energy increases the level of variability and uncertainty that a system operator must manage.

17 WIND ENERGY↗

Transactive System: Part I: Theoretical Underpinnings of Payoff Functions, Control Decisions, Information Privacy, and Solution Concepts

The increased penetration of renewable energy has significantly changed the conditions and the operational timing of the electricity grid. More flexible, faster ramping resources are needed to compensate for the uncertainty and variability introduced by renewable energy. Distributed energy resources (DERs) such as distributed generators, energy storage, and controllable loads could help manage the power grid in terms of both economic efficiency and operational reliability. In order to realize the benefits of DERs, coordination and control approaches must be designed to enable seamless integration of DERs into the power grid. Transactive coordination and control is a new approach for DER integration, where individual resources are automated and engaged through market interaction. Transactive approaches use economic signals—prices or incentives—to engage DERs. These economic signals must reflect the true value of the DER contributions, so that they seamlessly and equitably compete for the opportunities that today are only available to grid-owned assets. Value signals must be communicated to the DERs in near-real time, the assets must be imbued with new forms of distributed intelligence and control to take advantage of the opportunities presented by these signals, and they must be capable of negotiating and transacting a range of market-driven energy services. The concepts of transactive energy systems are not new, but build upon evolutionary economic changes in financial and electric power markets. These concepts also recognize the different regional structures of wholesale power markets, electricity delivery markets, retail markets, and vertically integrated service provider markets. Although transactive energy systems are not revolutionary, they will be transformational in their ability to provide flexibility and operational efficiency. A main goal of this research is to establish useful foundation for analysis of transactive energy systems and to facilitate new transactive energy system design with demonstrable guarantees on stability and performance. Specifically, the goals are to (1) establish a theoretical basis for evaluating the performance of different transactive systems, (2) devise tools to address canonical problems that exemplify challenges and scenarios of transactive systems, and (3) provide guidelines for design of future transactive systems. This report, Part 1 of a two part series, advances the above-listed research objectives by reviewing existing transactive systems and identifying a theoretical foundation that integrates payoff functions, control decisions, information privacy, and mathematical solution concepts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Value of Storage and Demand Response for Renewble Integration

Increased contributions from wind and solar power resources are necessary to meet California’s goal to use 33 percent renewable energy by 2020. Using these renewable resources, however, will substantially increase the variability and uncertainty in electricity generation resources available to California’s electricity grid operators. Automated demand response and energy storage systems can help reduce this variability and uncertainty through energy buying and selling (arbitrage) in day-ahead markets that would levelize loads and prices throughout the day. They could also provide load-following capability through bids in the real-time market and system management (or regulation) services to the system operator. The project identified policies, technologies (energy storage), and control methods (demand response) that could reduce the cost and improve the reliability of electric power for California ratepayers. Data and assumptions describing energy storage and demand response resources were provided by the Electric Power Research Institute, the California Energy Storage Alliance, and the Demand Response Research Center. The California Independent System Operator provided the production simulation model and supporting data.

14 SOLAR ENERGY↗

Transactive System: Part I: Theoretical Underpinnings of Payoff Functions, Control Decisions, Information Privacy, and Solution Concepts

The increased penetration of renewable energy has significantly changed the conditions and the operational timing of the electricity grid. More flexible, faster ramping resources are needed to compensate for the uncertainty and variability introduced by renewable energy. Distributed energy resources (DERs) such as distributed generators, energy storage, and controllable loads could help manage the power grid in terms of both economic efficiency and operational reliability. In order to realize the benefits of DERs, coordination and control approaches must be designed to enable seamless integration of DERs into the power grid. Transactive coordination and control is a new approach for DER integration, where individual resources are automated and engaged through market interaction. Transactive approaches use economic signals—prices or incentives—to engage DERs. These economic signals must reflect the true value of the DER contributions, so that they seamlessly and equitably compete for the opportunities that today are only available to grid-owned assets. Value signals must be communicated to the DERs in near-real time, the assets must be imbued with new forms of distributed intelligence and control to take advantage of the opportunities presented by these signals, and they must be capable of negotiating and transacting a range of market-driven energy services. The concepts of transactive energy systems are not new, but build upon evolutionary economic changes in financial and electric power markets. These concepts also recognize the different regional structures of wholesale power markets, electricity delivery markets, retail markets, and vertically integrated service provider markets. Although transactive energy systems are not revolutionary, they will be transformational in their ability to provide flexibility and operational efficiency. A main goal of this research is to establish useful foundation for analysis of transactive energy systems and to facilitate new transactive energy system design with demonstrable guarantees on stability and performance. Specifically, the goals are to (1) establish a theoretical basis for evaluating the performance of different transactive systems, (2) devise tools to address canonical problems that exemplify challenges and scenarios of transactive systems, and (3) provide guidelines for design of future transactive systems. This report, Part 1 of a two part series, advances the above-listed research objectives by reviewing existing transactive systems and identifying a theoretical foundation that integrates payoff functions, control decisions, information privacy, and mathematical solution concepts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pumped Storage Hydropower (PSH) FAST Commissioning Prize Technical Analysis

The US energy landscape has undergone major changes over the past 10 years and will continue to see significant changes in future decades as the power grid increases its reliance on variable renewable energy resources. Because of the inherent variability of these resources, renewable energy growth may require additional energy storage capacity to provide flexible load-following capabilities and other grid services that can quickly adjust to changes in energy demand and generation. Pumped storage hydropower (PSH)—one such energy storage technology—uses pumps to convey water from a lower reservoir to an upper reservoir for energy storage and releases water back to the lower reservoir via a powerhouse for hydropower generation. PSH facility pump and generation cycling often follows economic and energy demand conditions. Across the United States, 43 PSH facilities are in operation and 55 projects are in various permitting or licensing stages. Altogether, the 43 operational projects provide the wide majority (95%) of utility-scale electricity storage in the United States. These facilities also provide significant power and nonpower grid benefits, including large-scale electrical system reserve capacity, grid reliability support, and electricity supply-demand balancing through quick-response capabilities and operational flexibility. PSH systems can accomplish these at a scale (e.g., size) and cost that makes these systems highly attractive from a technical standpoint. Although these research concepts are still in their infancy, they demonstrate promising potential as future PSH energy storage technologies. Although PSH has many advantages, development in the United States has effectively stalled since the 1990s, partially because of the magnitude of project costs and financing interest during development and construction, the length of time from project investment until project revenue begins, permitting challenges, construction risks, competition from other storage technologies (e.g., batteries, hydrogen storage), and electricity market evolution and uncertainty. In short, the time, cost, and risk associated with modern PSH development have resulted in limited growth in the United States recently, despite the growing energy storage demand stemming from increased wind and solar power deployment. Technology innovation is needed to help reduce PSH commissioning time, cost, and risk, particularly during the post-licensing phase of project development. To address challenges facing the PSH industry and to improve PSH commissioning timelines, the US Department of Energy (DOE) Water Power Technologies Office (WPTO) initiated the PSH Furthering Advancements to Shorten Time to (FAST) Commissioning Prize project.

13 HYDRO ENERGY↗

Component level modeling of materials degradation for insights into operational flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility needs insights into accelerated material degradation arising due to the harsh operating conditions (e.g., fatigue, early oxide exfoliation due to stresses) along with current damage mechanisms (fireside corrosion, creep and erosion) observed in service. Our research objective is to develop component level modeling toolkit for materials-based degradation for two key mechanisms that can accelerate with cyclic operations. In more detail, this includes the fireside corrosion/steam oxidation/erosion/creep/fatigue of superheaters/reheaters and steam pipework and also the water droplet erosion/ fatigue of last stage steam turbine blades degradation mechanisms, that demand routine and sometimes unplanned maintenance and repair. The innovation is in developing a computational fluid dynamics/finite element (CFD/FE) modeling toolkit for the component level models of the boilers and low-pressure steam turbines in coal power plants that can tackle multidisciplinary failure mechanisms occurring concurrently for extreme environment materials. Lifetime assessment in such environments also needs to account for the unit-specific analyses, operational history and fuel feedstock; this can only be obtained by destructive analysis of components. This, in turn, enables validation of the model toolkits utilizing service feedback data, improving the probability of time/temperature dependent life prediction.

20 FOSSIL-FUELED POWER PLANTS↗

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS↗

Models used to assess the performance of photovoltaic systems.

This report documents the various photovoltaic (PV) performance models and software developed and utilized by researchers at Sandia National Laboratories (SNL) in support of the Photovoltaics and Grid Integration Department. In addition to PV performance models, hybrid system and battery storage models are discussed. A hybrid system using other distributed sources and energy storage can help reduce the variability inherent in PV generation, and due to the complexity of combining multiple generation sources and system loads, these models are invaluable for system design and optimization. Energy storage plays an important role in reducing PV intermittency and battery storage models are used to understand the best configurations and technologies to store PV generated electricity. Other researcher's models used by SNL are discussed including some widely known models that incorporate algorithms developed at SNL. There are other models included in the discussion that are not used by or were not adopted from SNL research but may provide some benefit to researchers working on PV array performance, hybrid system models and energy storage. The paper is organized into three sections to describe the different software models as applied to photovoltaic performance, hybrid systems, and battery storage. For each model, there is a description which includes where to find the model, whether it is currently maintained and any references that may be available. Modeling improvements underway at SNL include quantifying the uncertainty of individual system components, the overall uncertainty in modeled vs. measured results and modeling large PV systems. SNL is also conducting research into the overall reliability of PV systems.

14 SOLAR ENERGY↗

Multiphysics Modeling Framework for Soft PVC Gel Sensors with Experimental Comparisons

Polyvinyl chloride (PVC) gels have recently been found to exhibit mechanoelectrical transduction or sensing capabilities under compressive loading applications. This phenomenon is not wholly understood but has been characterized as an adsorption-like phenomena under varying amounts and types of plasticizers. A different polymer lattice structure has also been tested, thermoplastic polyurethane, which showed similar sensing characteristics. This study examines mechanical and electrical properties of these gel sensors and proposes a mathematical framework of the underlying mechanisms of mechanoelectrical transduction. COMSOL Multiphysics is used to show solid mechanics characteristics, electrostatic properties, and transport of interstitial plasticizer under compressive loading applications. The solid mechanics takes a continuum mechanics approach and includes a highly compressive Storakers material model for compressive loading applications. The electrostatics and transport properties include charge conservation and a Langmuir adsorption migration model with variable diffusion properties based on plasticizer properties. Results show both plasticizer concentration gradient as well as expected voltage response under varying amounts and types of plasticizers. Experimental work is also completed to show agreeance with the modeling results.

42 ENGINEERING↗