Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis and Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Sensitivity Analysis for the Component Design App: Analysis of Success Assured Data

A new tool has been developed to perform variance-based global sensitivity analysis (VBGSA) on data from a set-based concurrent engineering software called Success Assured (SA). The tool is part of a digital component design app, which is currently in production as an Accelerated Digital Engineering Pathfinder at Sandia National Laboratories. When working with complex digital models, it is important to understand relationships between inputs and outputs, i.e., how “sensitive” model outputs are to changes in model inputs. After extensive research and trials of various sensitivity analysis methods, it was determined that estimation of Sobol’ indices for VBGSA with Monte Carlo simulation, paired with simple surrogate models, produces the best results for SA data. This tool increases understanding of SA models and streamlines the creation of SA datasets. This report details the methodology and implementation of this sensitivity analysis tool so others can understand it and implement it.

97 MATHEMATICS AND COMPUTING↗

Toward improved durability in advanced aircraft engine hot sections; Proceedings of the Thirty-third ASME International Gas Turbine and Aeroengine Congress and Exposition, Amsterdam, Netherlands, June 5-9, 1988

The present conference on durability improvement methods for advanced aircraft gas turbine hot-section components discusses NASA's 'HOST' project, advanced high-temperature instrumentation for hot-section research, the development and application of combustor aerothermal models, and the evaluation of a data base and numerical model for turbine heat transfer. Also discussed are structural analysis methods for gas turbine hot section components, fatigue life-prediction modeling for turbine hot section materials, and the service life modeling of thermal barrier coatings for aircraft gas turbine engines.

Sokolowski, Daniel E.↗

Formal Methods Specification and Analysis Guidebook for the Verification of Software and Computer Systems: A Practitioner's Companion - Volume 2

This guidebook, the second of a two-volume series, is intended to facilitate the transfer of formal methods to the avionics and aerospace community. The 1st volume concentrates on administrative and planning issues [NASA-95a], and the second volume focuses on the technical issues involved in applying formal methods to avionics and aerospace software systems. Hereafter, the term "guidebook" refers exclusively to the second volume of the series. The title of this second volume, A Practitioner's Companion, conveys its intent. The guidebook is written primarily for the nonexpert and requires little or no prior experience with formal methods techniques and tools. However, it does attempt to distill some of the more subtle ingredients in the productive application of formal methods. To the extent that it succeeds, those conversant with formal methods will also nd the guidebook useful. The discussion is illustrated through the development of a realistic example, relevant fragments of which appear in each chapter. The guidebook focuses primarily on the use of formal methods for analysis of requirements and high-level design, the stages at which formal methods have been most productively applied. Although much of the discussion applies to low-level design and implementation, the guidebook does not discuss issues involved in the later life cycle application of formal methods.

Source record↗

WE-B-BRC-00: Concepts in Risk-Based Assessment

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗

WE-B-BRC-01: Current Methodologies in Risk Assessment

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗

WE-B-BRC-03: Risk in the Context of Medical Imaging

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗

SASS wind ambiguity removal by direct minimization. II - Use of smoothness and dynamical constraints

A variational analysis method (VAM) is used to remove the ambiguity of the Seasat-A Satellite Scatterometer (SASS) winds. The VAM yields the best fit to the data by minimizing an objective function S which is a measure of the lack of fit. The SASS data are described and the function S and the analysis procedure are defined. Analyses of a single ship report which are analogous to Green's functions are presented. The analysis procedure is tuned and its sensitivity is described using the QE II storm. The procedure is then applied to a case study of September 6, 1978, south of Japan.

Hoffman, R. N.↗

Improved method for stress and compatibility analysis of multicomponent rotating systems

An improved method of analyzing multicomponent rotating assemblies for the determination of operating stresses and component compatibility has been developed. In this method, a single finite element model is developed which contains all of the separate components in the rotating assembly. This is made possible by using gap elements to simulate the contact surfaces between components. The MARC finite element computer program is then used to perform the analysis. This improved method is less time consuming and more reliable than the conventional method of analyzing such systems. Results are presented for two different stress-compatibility analyses of a six-component axial flow compressor rotor. The results for the previously used flexibility analysis method are compared with those for the improved analysis method. The stresses predicted by each method compare quite well with each other. The predictions of the component compatibility, as well as the magnitude of the forces at the contact surfaces, also compare well for these two analysis procedures. It is therefore recommended that the improved analysis method be used to determine the stress-compatibility characterstics of multicomponent rotating systems.

Carek, Gerald A.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, 51%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear hits. Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1 %, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. Preliminary experiments show that the presence of the fluorescent probe does not affect the nucleation process or the quality of the X-ray data obtained.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically can not reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of a macromolecules purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals will show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "bits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Minamitani, Elizabeth Forsythe↗

Enhanced legume root growth with pre-soaking in α-Fe 2 O 3 nanoparticle fertilizer

The rising demand for food and energy crops has triggered interest in the use of nanoparticles for agronomy. Specifically, iron oxide-based engineered nanoparticles are promising candidates for next-generation iron-deficiency fertilizers. We used iron oxide and hybrid Pt-decorated iron oxide nanoparticles, at low and high concentrations, and at varied pHs, to model seed pre-soaking solutions for investigation of their effect on embryonic root growth in legumes. This is an environmentally friendly approach, as it uses less fertilizer, therefore less nanoparticles in contact with the soil. Analysis from varied material characterization techniques combined with a statistical analysis method found that iron oxide nanoparticles could enhance root growth by 88–366% at low concentrations (5.54 × 10 -3 mg L -1 Fe). Hybrid Pt-decorated iron oxide nanoparticles and a higher concentration of iron oxide nanoparticles (27.7 mg L -1 Fe) showed reduced root growth. The combined materials characterization and statistical analysis used here can be applied to address many environmental factors to finely tune the development of vital nanofertilizers for high efficiency food production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Advances in Small Angle X-ray Scattering for Superlattice Study

Small-angle x-ray scattering is used for the structure determination of superlattice for its superior resolution, nondestructive nature, and high penetration power of x rays. With the advent of high brilliance x-ray sources and innovative computing algorithms, there have been notable advances in small angle x-ray scattering analysis of superlattices. High brilliance x-ray beams have made data analyses less model-dependent. Additionally, novel data acquisition systems are faster and more competitive than ever before, enabling a more accurate mapping of the superlattices' reciprocal space. Fast and high-throughput computing systems and algorithms also make possible advanced analysis methods, including iterative phasing algorithms, non-parameterized fitting of scattering data with molecular dynamics simulations, and the use of machine learning algorithms. As a result, solving nanoscale structures with high resolutions has become an attainable task. In this review, we highlight new developments in the field and introduce their applications for the analysis of nanoscale ordered structures, including nanoparticle supercrystals, nanoscale lithography patterns, and supramolecular self-assemblies. Particularly, we highlight the reciprocal space mapping techniques and the use of iterative phase retrieval algorithms. We also cover coherent-beam-based small angle x-ray scattering techniques such as ptychography and ptycho-tomography in view of the traditional small angle x-ray scattering perspective.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Equivalent plate modeling for conceptual design of aircraft wing structures

This paper describes an analysis method that generates conceptual-level design data for aircraft wing structures. A key requirement is that this data must be produced in a timely manner so that is can be used effectively by multidisciplinary synthesis codes for performing systems studies. Such a capability is being developed by enhancing an equivalent plate structural analysis computer code to provide a more comprehensive, robust and user-friendly analysis tool. The paper focuses on recent enhancements to the Equivalent Laminated Plate Solution (ELAPS) analysis code that significantly expands the modeling capability and improves the accuracy of results. Modeling additions include use of out-of-plane plate segments for representing winglets and advanced wing concepts such as C-wings along with a new capability for modeling the internal rib and spar structure. The accuracy of calculated results is improved by including transverse shear effects in the formulation and by using multiple sets of assumed displacement functions in the analysis. Typical results are presented to demonstrate these new features. Example configurations include a C-wing transport aircraft, a representative fighter wing and a blended-wing-body transport. These applications are intended to demonstrate and quantify the benefits of using equivalent plate modeling of wing structures during conceptual design.

Giles, Gary L.↗

Macquarie Island Cloud and Radiation Experiment (MICRE) Ice Nucleating Particle Measurements Field Campaign Report

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Macquarie Island Cloud and Radiation Experiment (MICRE) Ice Nucleating Particle Measurements campaign was aligned as a supplemental activity with the second year of the overall MICRE campaign. The purpose of the supplemental campaign was to provide a first-ever annual cycle of ice nucleating particle (INP) measurements at a Southern Ocean (SO) site, toward the investigation/characterization of sources of INPs in the marine boundary layer as being from the production or primary sea spray aerosol (SSA) emissions versus other long-range transport influences. Furthermore, measuring the variability in INPs seasonally in this region, as this may relate to meteorology and ocean biological processes, is expected to help constrain (via parameterizations) numerical model simulations of cloud phase and regional climate. In concert with other SO studies during the time frame of the campaign (March 2017 to March 2018), MICRE sought to evaluate the hypotheses that SSA INPs represent the major INP source in the SO and, due to their generally less efficient INP activation properties compared to terrestrial sources, that they may directly influence the persistence of supercooled clouds in a unique manner for this climatic region. These measurements supplemented the original deployment of primarily radiation measurements provided in the ARM MICRE request and the associated Australian Antarctic Division (AAD) Antarctic Clouds and Radiation Experiment (ACRE). Assistance and collaboration was obtained from the AAD, the Commonwealth Scientific and Industrial Research Organization (CSIRO) and the Australian Bureau of Meteorology (BOM). Follow-up plans will include investigations with their additional aerosol, cloud, and radiative transfer measurements. AAD also saw to the transport to Australia and storage of filters at the end of the campaign. The added effort involved an average of twice-weekly collections (a 48-hour and a 72-hour collection) of pre-sterilized, open-faced, polycarbonate filter samples for post-processing of INP number concentrations and tests to analyze the nature of INP sources. Collections were made by AAD technician Emry Thaggard Crocker after online training from our team. Images of the filter sampler and site are shown in Figure 1. Sampling occurred from an approximate elevation of 4m MSL. Filters were returned frozen to Colorado State University (CSU) at the end of the campaign. Initial processing to obtain INP temperature spectra (0 to -28°C) of the concentrations of INPs active via the immersion freezing mechanism were conducted using the CSU ice spectrometer (IS) instrument systems (Hiranuma et al. 2015; McCluskey et al. 2018). In this method, particles are first removed from filters using ultrapure water while under mechanical agitation. Arrays of the particle suspensions from a portion of filter rinses are then cooled to obtain immersion freezing data per volume of water, and finally are related to sampling volumes to obtain numbers per volume of air following the analysis methods of Vali (1971). A total of 103 filters were collected, including blanks at selected intervals throughout the project. For archival and completion of tasks under this ARM proposal, nearly half of the filter collections (46) were processed for basic temperature spectra, and half of these (23) were also tested for microbial/proteinaceous contributions toward INPs via 95°C pre-treatment of portions of the original suspensions.

Southern Ocean, aerosols, marine clouds, MARCUS ca↗

Thermal Modeling Method Improvements for SAGE III on ISS

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument is the fifth in a series of instruments developed for monitoring aerosols and gaseous constituents in the stratosphere and troposphere. SAGE III will be delivered to the International Space Station (ISS) via the SpaceX Dragon vehicle. A detailed thermal model of the SAGE III payload, which consists of multiple subsystems, has been developed in Thermal Desktop (TD). Many innovative analysis methods have been used in developing this model; these will be described in the paper. This paper builds on a paper presented at TFAWS 2013, which described some of the initial developments of efficient methods for SAGE III. The current paper describes additional improvements that have been made since that time. To expedite the correlation of the model to thermal vacuum (TVAC) testing, the chambers and GSE for both TVAC chambers at Langley used to test the payload were incorporated within the thermal model. This allowed the runs of TVAC predictions and correlations to be run within the flight model, thus eliminating the need for separate models for TVAC. In one TVAC test, radiant lamps were used which necessitated shooting rays from the lamps, and running in both solar and IR wavebands. A new Dragon model was incorporated which entailed a change in orientation; that change was made using an assembly, so that any potential additional new Dragon orbits could be added in the future without modification of the model. The Earth orbit parameters such as albedo and Earth infrared flux were incorporated as time-varying values that change over the course of the orbit; despite being required in one of the ISS documents, this had not been done before by any previous payload. All parameters such as initial temperature, heater voltage, and location of the payload are defined based on the case definition. For one component, testing was performed in both air and vacuum; incorporating the air convection in a submodel that was only built for the in-air cases allowed correlation of all testing to be done in a single model. These modeling improvements and more will be described and illustrated in the paper.

Liles, Kaitlin↗

Design optimization methods for high-performance research reactor core design

Typical objectives of high-performance research reactors include neutron scattering, materials irradiation, and isotope production. The creation of a core that optimizes these multiple objectives often presents a multidimensional (i.e., in design space), multiobjective optimization problem. The developed systematic approach discussed herein draws on response surface methodology to validate and leverage a surrogate model to serve in place of high-fidelity computational analyses. Optimization and design analysis methods leverage this surrogate model to provide a flexible tool for generating optimized designs and understanding the impact of design decisions on desired metrics. In applications to High Flux Isotope Reactor (HFIR) low-enriched uranium (LEU) core designs, neutronic, isotopic evolution, and thermal hydraulic analyses are used to generate key performance and safety metrics for assessing the feasibility and fitness of given designs. Three optimized designs that determine different desired metrics and constraints (e.g., key metric weighting and fabrication constraints) are presented, providing potential design options that satisfy the requirements for HFIR’s conversion from high enriched uranium to LEU fuel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗