At least 1,477 records · Page 82

Spacecraft self-contamination due to back-scattering of outgas products

The back-scattering of outgas contamination near an orbiting spacecraft due to intermolecular collisions was analyzed. Analytical tools were developed for making reasonably accurate quantitative estimates of the outgas contamination return flux, given a knowledge of the pertinent spacecraft and orbit conditions. Two basic collision mechanisms were considered: (1) collisions involving only outgas molecules (self-scattering) and (2) collisions between outgas molecules and molecules in the ambient atmosphere (ambient-scattering). For simplicity, the geometry was idealized to a uniformly outgassing sphere and to a disk oriented normal to the freestream. The method of solution involved an integration of an approximation of the Boltzmann kinetic equation known as the BGK (or Krook) model equation. Results were obtained in the form of simple equations relating outgas return flux to spacecraft and orbit parameters. Results were compared with previous analyses based on more simplistic models of the collision processes.

Robertson, S. J.↗

Results of an analytical study of spacecraft deposition contamination by internal reflection spectroscopy

Outgassing, deposition, and desorption kinetics of silicone compounds, are examined as examples of optical surface contaminants of spacecraft windows. Their behavior in a space environment after exposure to ultraviolet radiation is also examined. The use of internal reflection spectroscopy is shown to provide a viable means of real-time, in-situ identification of contaminants of orbiting spacecraft. The instrumental techniques are proposed as the basis of further investigations and the development of flight hardware.

Mookherji, T.↗

Monitoring spacecraft atmosphere contaminants by laser absorption spectroscopy

Laser-based spectrophotometric methods which have been proposed for the detection of trace concentrations of gaseous contaminants include Raman backscattering (LIDAR) and passive radiometry (LOPAIR). Remote sensing techniques using laser spectrometry are presented and in particular a simple long-path laser absorption method (LOLA), which is capable of resolving complex mixtures of closely related trace contaminants at ppm levels is discussed. A number of species were selected for study which are representative of those most likely to accumulate in closed environments, such as submarines or long-duration manned space flights. Computer programs were developed which will permit a real-time analysis of the monitored atmosphere. Estimates of the dynamic range of this monitoring technique for various system configurations, and comparison with other methods of analysis, are given.

Steinfeld, J. I.↗

Payload/orbiter contamination control requirement study: Computer interface

A preliminary assessment of the computer interface requirements of the Spacelab configuration contamination computer model was conducted to determine the compatibility of the program, as presently formatted, with the computer facilities at MSFC. The necessary Spacelab model modifications are pointed out. The MSFC computer facilities and their future plans are described, and characteristics of the various computers as to availability and suitability for processing the contamination program are discussed. A listing of the CDC 6000 series and UNIVAC 1108 characteristics is presented so that programming requirements can be compared directly and differences noted.

Bareiss, L. E.↗

Preliminary Shuttle payload contamination assessment

The paper discusses the molecular induced atmosphere of the Shuttle Orbiter and a payload carrier (Spacelab) configuration - long module and a 3-m pallet) in the Shuttle Orbiter payload bay and compares it to the ambient atmosphere at various orbital altitudes. The density and flux of the contaminants are expressed as a function of distance out of the payload bay for a line-of-sight perpendicular to the payload bay and payload carrier. Isodensity plots about the Shuttle Orbiter for a side and end view for each major source are presented. The major sources considered are the external surface materials mass loss, pressurized habitation area leakage, attitude control engines, and supplemental flash evaporator venting. The resulting plots provide an insight into the extent and spatial variation of the on-orbit contaminant-induced environment.

Ress, E. B.↗

Contamination from Skylab as determined from the solar coronagraph data

The white light solar coronagraph was one of the scientific telescopes flown on Skylab to study the sun. It studied the sun's atmosphere located from 0.5 to 5.0 solar radii above the sun's limb. Such a telescope is so sensitive to contamination around the spacecraft that it caused a major contamination abatement program to be initiated at the conception of Skylab. The coronagraph's data is analyzed showing the successfulness of that abatement program.

Mcguire, J. P.↗

Orbiter/payload contamination control assessment support

The development and use of a contamination math model of the shuttle orbiter which incorporates specific shuttle orbiter configurations and contamination sources is described. These configurations and sources represent the latest design of the shuttle orbiter and its sources. The results of model predictions for many lines-of-sight and individual and grouped sources are presented. Support trade studies primarily concerned with the supplemental flash evaporator location and operation are presented.

Rantanen, R. O.↗

Methodology for back-contamination risk assessment for a Mars sample return mission

The risk of back-contamination from Mars Surface Sample Return (MSSR) missions is assessed. The methodology is designed to provide an assessment of the probability that a given mission design and strategy will result in accidental release of Martian organisms acquired as a result of MSSR. This is accomplished through the construction of risk models describing the mission risk elements and their impact on back-contamination probability. A conceptual framework is presented for using the risk model to evaluate mission design decisions that require a trade-off between science and planetary protection considerations.

Merkhofer, M. W.↗

Effect of ice contamination of liquid-nitrogen drops in film boiling

Previously reported vaporization time data of liquid nitrogen drops in film boiling on a flat plate are about 30 percent shorter than predicted from standard laminar film boiling theory. This theory, however, had been found to successfully correlate the data for conventional fluids such as water, ethanol, benzene, or carbon tetrachloride. Experimental evidence that some of the discrepancy for cryogenic fluids results from ice contamination due to condensation is presented. The data indicate a fairly linear decrease in droplet evaporation time with the diameter of the ice crystal residue. After correcting the raw data for ice contamination along with convection, a comparison of theory with experiment shows good agreement.

Schoessow, G. J.↗

Effect of the Shuttle contaminant environment on a sensitive infrared telescope

A sensitive IR telescope on the Space Shuttle Orbiter will be limited in its performance by fluctuations in the IR radiation from the natural environment and the contaminant atmosphere. Models of the Orbiter's contaminant atmosphere were used to predict its spectral radiance from 3 to 300 microns. At 350 km, statistical fluctuations in the radiation from a water vapor column, and a noise equivalent power were measured. This noise is somewhat smaller than the expected contribution from zodiacal light from 5 to 30 microns. The column density of all IR emitting molecules can be kept low only if restrictions on rocket firings and liquid vents are maintained. The relatively low frequency of particle sightings from Skylab, coupled with improvements in Orbiter venting techniques, indicate that sightings of particles 2 microns and larger in radius will not seriously hamper telescope performance provided that liquid vents and rocket firings are properly restricted.

Simpson, J. P.↗

Spacelab baseline ECS trace contaminant removal test program

An estimate of the Spacelab Baseline Environmental Control System's contaminated removal capability was required to allow determination of the need for a supplemental trace contaminant removal system. Results from a test program to determine this removal capability are presented.

Ray, C. D.↗

Review of the absorption spectra of solid O2 and N2 as they relate to contamination of a cooled infrared telescope

During contamination studies for the liquid helium cooled shuttle infrared telescope facility, a literature search was conducted to determine the absorption spectra of the solid state of homonuclear molecules of O2 and N2, and ascertain what laboratory measurements of the solid have been made in the infrared. With the inclusion of one unpublished spectrum, the absorption spectrum of the solid oxygen molecule has been thoroughly studied from visible to millimeter wavelengths. Only two lines appear in the solid that do not also appear in the gas or liquid. A similar result is implied for the solid nitrogen molecule because it also is homonuclear. The observed infrared absorption lines result from lattice modes of the alpha phase of the solid, and disappear at the warmer temperatures of the beta, gamma, and liquid phases. They are not observed from polycrystalline forms of O2, while strong scattering is. Scattering, rather than absorption, is considered to be the principal natural contamination problem for cooled infrared telescopes in low earth orbit.

Smith, S. M.↗

Filtration effects on ball bearing life and condition in a contaminated lubricant

Ball bearings were fatigue tested with a noncontaminated lubricant and with a contaminated lubricant under four levels of filtration. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns. Aircraft turbine engine contaminants were injected into the filter's supply line at a constant rate of 125 milligrams per bearing hour. Bearing life and running track condition generally improved with finer filtration. The experimental lives of 3 and 30 micron filter bearings were statistically equivalent, approaching those obtained with the noncontaminated lubricant bearings. Compared to these bearings, the lives of the 49 micron bearings were statistically lower. The 105 micron bearings experienced gross wear. The degree of surface distress, weight loss, and probable failure mode were dependent on filtration level, with finer filtration being clearly beneficial.

Loewenthal, S. H.↗

An Induced Environment Contamination Monitor for the Space Shuttle

The Induced Environment Contamination Monitor (IECM), a set of ten instruments integrated into a self-contained unit and scheduled to fly on shuttle Orbital Flight Tests 1 through 6 and on Spacelabs 1 and 2, is described. The IECM is designed to measure the actual environment to determine whether the strict controls placed on the shuttle system have solved the contamination problem. Measurements are taken during prelaunch, ascent, on-orbit, descent, and postlanding. The on-orbit measurements are molecular return flux, background spectral intensity, molecular deposition, and optical surface effects. During the other mission phases dew point, humidity, aerosol content, and trace gas are measured as well as optical surface effects and molecular deposition. The IECM systems and thermal design are discussed. Preflight and ground operations are presented together with associated ground support equipment. Flight operations and data reduction plans are given.

Miller, E. R.↗

Effect of ice contamination on liquid-nitrogen drops in film boiling

Previously reported vaporization time data of liquid nitrogen drops in film boiling on a flat plate are about 30 percent shorter than predicted from standard laminar film boiling theory. This theory, however, had been found to successfully correlate the data for conventional fluids such as water, ethanol, benzene, or carbon tetrachloride. This paper presents experimental evidence that some of the discrepancy for cryogenic fluids results from ice contamination due to condensation. The data indicate a fairly linear decrease in droplet evaporation time with the diameter of the ice crystal residue. After correcting the raw data for ice contamination along with convection, a comparison of theory with experiment shows good agreement.

Schoessow, G. J.↗

Some aspects of contamination detection, analyses, and control in microcircuits for the NASA Space Shuttle program

The Space Shuttle system is currently one of the National Aeronautics and Space Administration's (NASA) most important and complex programs. A significant number of hybrid microcircuits are being developed and used on the Space Shuttle. Since the Shuttle is a manned vehicle, reliability of the hybrids is flight critical. Loose particle contamination is one of the major causes of failure and reduced operating life for microcircuits. Process controls, surface coatings, and the particle impact noise detection (PIND) test were assessed for control of particle contamination, and the decision was made by NASA to require PIND test for all hybrid circuits. Selected hybrids from the production line of one vendor that had failed the PIND test were analyzed. Results of this program are presented.

Caruso, S. V.↗

Cleaning process for contaminated superalloy powders

A cleaning process for removing interstitial contaminants from superalloy powders after wet grinding is described. Typical analyses of oxygen, carbon, nitrogen, and hydrogen in ball-milled WAZ-20 superalloy samples after hydrogen plus vacuum cleaning are presented. The hydrogen cleaning step involves heating retorts containing superalloy powder twice under flowing hydrogen with a 24-hour hold at each temperature. The vacuum step involves heating cold-pressed billets two hours at an elevated temperature at a pressure of 10 microPa. It is suggested that the hydrogen plus vacuum cleaning procedure can be applied to superalloys contaminated by other substances in other industrial processes.

Anglin, A. E.↗

Cleaning contaminated superalloy powders

Cleaning process reduces level of contaminants in superalloy end product. Procedure has applications to variety of powder metallurgy contamination problems.

Anglin, A. E.↗