Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Damage assessment and residual compression strength of thick composite plates with through-the-thickness reinforcements

Damage in composite materials was studied with through-the-thickness reinforcements. As a first step it was necessary to develop new ultrasonic imaging technology to better assess internal damage of the composite. A useful ultrasonic imaging technique was successfully developed to assess the internal damage of composite panels. The ultrasonic technique accurately determines the size of the internal damage. It was found that the ultrasonic imaging technique was better able to assess the damage in composite panel with through-the-thickness reinforcements than by destructively sectioning the specimen and visual inspection under a microscope. Five composite compression-after-impact panels were tested. The compression-after-impact strength of the panels with the through-the-thickness reinforcements was almost twice that of the comparable panel without through-the-thickness reinforcement.

Smith, Barry T.↗

Neural networks for calibration tomography

Artificial neural networks are suitable for performing pattern-to-pattern calibrations. These calibrations are potentially useful for facilities operations in aeronautics, the control of optical alignment, and the like. Computed tomography is compared with neural net calibration tomography for estimating density from its x-ray transform. X-ray transforms are measured, for example, in diffuse-illumination, holographic interferometry of fluids. Computed tomography and neural net calibration tomography are shown to have comparable performance for a 10 degree viewing cone and 29 interferograms within that cone. The system of tomography discussed is proposed as a relevant test of neural networks and other parallel processors intended for using flow visualization data.

Decker, Arthur↗

A study of the compressible flow through a diffusing S-duct

Benchmark aerodynamic data are presented for compressible flow through a representative S-duct configuration. A numerical prediction of the S-duct flow field, obtained from a subsonic parabolized Navier-Stokes algorithm, is also shown. The experimental and numerical results are compared. Measurements of the three-dimensional velocity field, total pressures, and static pressures were obtained at five cross-sectional planes. Aerodynamic data were gathered with calibrated pneumatic probes. Surface static pressure and surface flow visualization data were also acquired. All reported tests were conducted with an inlet centerline Mach number of 0.6. The Reynolds number, based on the inlet centerline velocity and duct inlet diameter, was 2.6 x 10(exp 6). Thin inlet turbulent boundary layers existed. The collected data should be beneficial to aircraft inlet designers and the measurements are suitable for the validation of computational codes. The results show that a region of streamwise flow separation occurred within the duct. Details about the separated flow region, including mechanisms which drive this complicated flow phenomenon, are discussed. Results also indicate that the duct curvature induces strong pressure driven secondary flows. The cross flows evolve into counter-rotating vortices. These vortices convect low momentum fluid of the boundary layer toward the center of the duct, degrading both the uniformity and magnitude of the total pressure profile.

Wellborn, Steven R.↗

A Spatial Classifier for Multispectral Data Using Contextual Information

Connectivity describes the spatial relationship among pixels. A spatial classifier which employs the sigma probability concept of the Gaussian distribution and a type of contextual information connectivity of the pixels, is studied in this paper. This spatial classifier attempts to replicate the kind of spatial synthesis done by the human analyst during visual interpretation or to capture the spatial relationships inherent in an aerial photograph. Several classification results of the Landsat TM data using this classifier with different window sizes for capturing the contextual information are illustrated and compared.

Hung, Chih-Cheng↗

Changes in Jump-Down Performance After Space Flight: Short- and Long-Term Adaptation

INTRODUCTION Successful jump performance requires functional coordination of visual, vestibular, and somatosensory systems, which are affected by prolonged exposure to microgravity. Astronauts returning from space flight exhibit impaired ability to coordinate effective landing strategies when jumping from a platform to the ground. This study compares the jump strategies used by astronauts before and after flight, the changes to those strategies within a test session, and the recoveries in jump-down performance parameters across several postflight test sessions. These data were obtained as part of an ongoing interdisciplinary study (Functional Task Test, FTT) designed to evaluate both astronaut postflight functional performance and related physiological changes. METHODS Six astronauts from short-duration (Shuttle) and three from long-duration (International Space Station) flights performed 3 two-footed jumps from a platform 30 cm high. A force plate measured the ground reaction forces and center-of-pressure displacement from the landings. Muscle activation data were collected from the medial gastrocnemius and anterior tibialis of both legs using surface electromyography electrodes. Two load cells in the platform measured the load exerted by each foot during the takeoff phase of the jump. Data were collected in 2 preflight sessions, on landing day (Shuttle only), and 1, 6, and 30 days after flight. RESULTS AND CONCLUSION Many of the astronauts tested were unable to maintain balance on their first postflight jump landing but recovered by the third jump, showing a learning progression in which the performance improvement could be attributed to adjustments of strategy on takeoff, landing, or both. Takeoff strategy changes were evident in air time (time between takeoff and landing), which was significantly reduced after flight, and also in increased asymmetry in foot latencies on takeoff. Landing modifications were seen in changes in ground reaction force curves. The results demonstrate astronauts adaptive capabilities and full performance recovery within days after flight.

Kofman, I. S.↗

Jump-Down Performance Alterations after Space Flight

INTRODUCTION: Successful jump performance requires functional coordination of visual, vestibular, and somatosensory systems, which are affected by prolonged exposure to microgravity. Astronauts returning from space flight exhibit impaired ability to coordinate effective landing strategies when jumping from a platform to the ground. This study compares jump strategies used by astronauts before and after flight, changes to those strategies within a test session, and recoveries in jump-down performance parameters across several postflight test sessions. These data were obtained as part of an ongoing interdisciplinary study (Functional Task Test, FTT) designed to evaluate both astronaut postflight functional performance and related physiological changes. METHODS: Seven astronauts from short-duration (Shuttle) and three from long-duration (International Space Station) flights performed 3 two-footed jumps from a platform 30 cm high onto a force plate that measured the ground reaction forces and center-of-pressure displacement from the landings. Neuromuscular activation data were collected from the medial gastrocnemius and anterior tibialis of both legs using surface electromyography electrodes. Two load cells in the platform measured the load exerted by each foot during the takeoff phase of the jump. Data were collected in 2 preflight sessions, on landing day (Shuttle only), and 1, 6, and 30 days after flight. RESULTS: Postural settling time was significantly increased on the first postflight test session and many of the astronauts tested were unable to maintain balance on their first jump landing but recovered by the third jump, showing a learning progression in which performance improvements could be attributed to adjustments in takeoff or landing strategy. Jump strategy changes were evident in reduced air time (time between takeoff and landing) and also in increased asymmetry in foot latencies on takeoff. CONCLUSIONS: The test results revealed significant decrements in astronauts abilities to maintain balance and achieve a postural stability upon landing from a jump early after flight. However, the jump landing adaptation process often begins after the first jump with full recovery of most performance parameters within days after space flight. As expected, performance of ISS astronauts on the first day after flight was similar to that of Shuttle crewmembers on landing day.

Reschke, M. F.↗

TPSAS-NF1676L-18030-DND

This study investigated the relative acceptance of different avionics implementations that present Flightdeck Interval Management (FIM) speeds and speed deviations to commercial pilots, and for indications of conditions that require action. Each crew evaluated four Avionics conditions: (1) Integrated in which the FIM target speed was presented in the upper left corner of the primary flight display (PFD) and speed profile deviation information was implicitly indicated as the deviation between current speed and an instantaneous speed profile bug on the PFD speed tape. In this Avionics condition, clearance information would have been entered, and could be referenced, on the FIM page in the MCDU. This page also gave a digital readout of speed profile deviation. Significant deviations from the speed profile triggered a message on the EICAS system. (2) EFB-Aft in which an aft-mounted EFB was used as the device housing the FIM algorithm and presented all the relevant information for the operation, including speed targets, speed deviation information, and all elements of the IM clearance. Significant deviations from the speed profile triggered messages on the same EFB display. (3) EFB-Fore in which the same information was presented as in the EFB-Aft condition, but the display was mounted in a more forward location, just under the outboard window. (4) EFB-Aft-AGD in which the EFB-Aft condition was augmented with the ADS-B Guidance Display (AGD). The AGD repeats the same FIM target speed and speed deviation information provided on the EFB. This study compares the efficacy of these Avionics Conditions as well as three methods of annunciating FIM events (a new speed, a reminder that a new speed occurred, and a deviation from the FIM speed profile), using only visual indications, visual indications and an aural for all events, or visual indications for all events plus an aural for speed deviations only. Results show clear preference for the Integrated condition and the use of aural indications. Other metrics of performance using these conditions and methods are mixed.

Kara Latorella↗

Flow Boiling & Condensation Experiment (FBCE): Flow Boiling in Earth Gravity and Onboard the International Space Station

Two phase thermal management systems that capitalize on both latent and sensible heats of the working fluid can yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients and reduce size and weight of future space systems. Because the understanding of microgravity influences on two-phase flow and heat transfer is quite limited, there is presently an urgent need for a new experimental microgravity facility to enable investigators to perform long-duration flow boiling and condensation experiments in pursuit of reliable databases. This presentation will discuss results from the Flow Boiling and Condensation Experiment (FBCE), a collaborative effort between Purdue University and NASA Glenn Research Center. Experiments have been performed using the final system with the Flow Boiling Module (FBM) in vertical orientation in Earth gravity (Mission Sequence Tests, MST) and in microgravity onboard the International Space Station (ISS). High-speed-video flow visualization, heat transfer, and critical heat flux (CHF) results from the MST are presented for both subcooled liquid and saturated liquid-vapor inlet conditions. CHF predictions made using the Interfacial Lift-off Model are compared with a consolidated database made by compiling FBM datasets obtained in prior years for different orientations in Earth gravity and on parabolic flights. New explicit correlations for CHF and subcooled flow boiling heat transfer coefficient are developed and shown to be excellent in their predictive accuracies against consolidated experimental databases. Computations are performed for flows in microgravity and horizontal flows in Earth gravity, the results of which show a good predictive accuracy for both void fraction and wall temperature. Finally, similar preliminary results from the recent ISS experiments are presented.

Issam Mudawar↗

High-speed X-ray visualization of dynamic crack initiation and propagation in bone

The initiation and propagation of physiological cracks in porcine cortical and cancellous bone under high rate loading were visualized using high-speed synchrotron X-ray phase-contrast imaging (PCI) to characterize their fracture behaviors under dynamic loading conditions. A modified Kolsky compression bar was used to apply dynamic three-point flexural loadings on notched specimens and images of the fracture processes were recorded using a synchronized high-speed synchrotron X-ray imaging set-up. Three-dimensional synchrotron X-ray tomography was conducted to examine the initial microstructure of the bone before high-rate experiments. The experimental results showed that the locations of fracture initiations were not significantly different between the two types of bone. However, the crack velocities in cortical bone were higher than in cancellous bone. Crack deflections at osteonal cement lines, a prime toughening mechanism in bone at low rates, were observed in the cortical bone under dynamic loading in this study. Fracture toughening mechanisms, such as untracked ligament bridging and bridging in crack wake were also observed for the two types of bone. The results also revealed that the fracture toughness of cortical bone was higher than cancellous bone. The crack was deflected to some extent at osteon cement line in cortical bone instead of comparatively penetrating straight through the microstructures in cancellous bone. Statement of Significance Fracture toughness is with great importance to study for crack risk prediction in bone. For those cracks in bone, most of them are associated with impact events, such as sport accidents. Consequently, we visualized, in real-time, the entire processes of dynamic fractures in notched cortical bone and cancellous bone specimens using synchrotron X-ray phase contrast imaging. The onset location of crack initiation was found independent on the bone type. We also found that, although the extent was diminished, crack deflections at osteon cement lines, a major toughening mechanism in transversely orientated cortical bone at quasi-static rate, were still played a role in resisting cracking in dynamically loaded specimen. Furthermore, these finding help researchers to understand the dynamic fracture behaviors in bone.

59 BASIC BIOLOGICAL SCIENCES↗

Remedial Amendment Delivery near the Water Table Using Shear Thinning Fluids: Experiments and Numerical Simulations

The use of shear thinning fluids (STFs) containing xanthan is a potential enhancement for emplacing a solute amendment near the water table and within the capillary fringe. Most research to date related to STF behavior has involved saturated and confined conditions. A series of flow cell experiments were conducted to investigate STF emplacement in variable saturated homogeneous and layered heterogeneous systems. Besides flow visualization using dyes, amendment concentrations and pressure data were obtained at several locations. The experiments showed that injection of STFs considerably improved the subsurface distribution near the water table by mitigating preferential flow through higher permeability zones compared to no-polymer injections. The phosphate amendment migrated with the xanthan SFT without retardation. Despite the high viscosity of the STF, no excessive mounding or preferential flow were observed in the unsaturated zone. The STOMP simulator was able to predict the experimentally observed fluid displacement and amendment concentrations reasonably well. Cross flow between layers could be interpreted as the main mechanism to transport STFs into lower permeability layers based on the observed pressure gradient and concentration data in layers of differing hydraulic conductivity.

Environmental Molecular Sciences Laboratory↗

Optimal experimental design for the detection of light atoms from high-resolution scanning transmission electron microscopy images

We report an innovative method to explore the optimal experimental settings to detect light atoms from scanning transmission electron microscopy (STEM) images. Since light elements play a key role in many technologically important materials, such as lithium-battery devices or hydrogen storage applications, much effort has been made to optimize the STEM technique in order to detect light elements. Therefore, classical performance criteria, such as contrast or signal-to-noise ratio, are often discussed hereby aiming at improvements of the direct visual interpretability. However, when images are interpreted quantitatively, one needs an alternative criterion, which we derive based on statistical detection theory. Using realistic simulations of technologically important materials, we demonstrate the benefits of the proposed method and compare the results with existing approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-126: Respiratory Gating Quality Assurance: A Simple Method to Achieve Millisecond Temporal Resolution

Purpose: Low temporal latency between a gating on/off signal and a linac beam on/off during respiratory gating is critical for patient safety. Although, a measurement of temporal lag is recommended by AAPM Task Group 142 for commissioning and annual quality assurance, there currently exists no published method. Here we describe a simple, inexpensive, and reliable method to precisely measure gating lag at millisecond resolutions. Methods: A Varian Real-time Position Management™ (RPM) gating simulator with rotating disk was modified with a resistive flex sensor (Spectra Symbol) attached to the gating box platform. A photon diode was placed at machine isocenter. Output signals of the flex sensor and diode were monitored with a multichannel oscilloscope (Tektronix™ DPO3014). Qualitative inspection of the gating window/beam on synchronicity were made by setting the linac to beam on/off at end-expiration, and the oscilloscope's temporal window to 100 ms to visually examine if the on/off timing was within the recommended 100-ms tolerance. Quantitative measurements were made by saving the signal traces and analyzing in MatLab™. The on and off of the beam signal were located and compared to the expected gating window (e.g. 40% to 60%). Four gating cycles were measured and compared. Results: On a Varian TrueBeam™ STx linac with RPM gating software, the average difference in synchronicity at beam on and off for four cycles was 14 ms (3 to 30 ms) and 11 ms (2 to 32 ms), respectively. For a Varian Clinac™ 21EX the average difference at beam on and off was 127 ms (122 to 133 ms) and 46 ms (42 to 49 ms), respectively. The uncertainty in the synchrony difference was estimated at ±6 ms. Conclusion: This new gating QA method is easy to implement and allows for fast qualitative inspection and quantitative measurements for commissioning and TG-142 annual QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-59: Feasibility of Markerless Tumor Tracking by Sequential Dual-Energy Fluoroscopy On a Clinical Tumor Tracking System

Purpose: To evaluate the feasibility of markerless tumor tracking through the implementation of a novel dual-energy imaging approach into the clinical dynamic tracking (DT) workflow of the Vero SBRT system. Methods: Two sequential 20 s (11 Hz) fluoroscopy sequences were acquired at the start of one fraction for 7 patients treated for primary and metastatic lung cancer with DT on the Vero system. Sequences were acquired using 2 on-board kV imaging systems located at ±45° from the MV beam axis, at respectively 60 kVp (3.2 mAs) and 120 kVp (2.0 mAs). Offline, a normalized cross-correlation algorithm was applied to match the high (HE) and low energy (LE) images. Per breathing phase (inhale, exhale, maximum inhale and maximum exhale), the 5 best-matching HE and LE couples were extracted for DE subtraction. A contrast analysis according to gross tumor volume was conducted based on contrast-to-noise ratio (CNR). Improved tumor visibility was quantified using an improvement ratio. Results: Using the implanted fiducial as a benchmark, HE-LE sequence matching was effective for 13 out of 14 imaging angles. Overlying bony anatomy was removed on all DE images. With the exception of two imaging angles, the DE images showed no significantly improved tumor visibility compared to HE images, with an improvement ratio averaged over all patients of 1.46 ± 1.64. Qualitatively, it was observed that for those imaging angles that showed no significantly improved CNR, the tumor tissue could not be reliably visualized on neither HE nor DE images due to a total or partial overlap with other soft tissue. Conclusion: Dual-energy subtraction imaging by sequential orthogonal fluoroscopy was shown feasible by implementing an additional LE fluoroscopy sequence. However, for most imaging angles, DE images did not provide improved tumor visibility over single-energy images. Optimizing imaging angles is likely to improve tumor visibility and the efficacy of dual-energy imaging. This work was in part sponsored by corporate funding from BrainLAB AG.(BrainLAB AG, Feldkirchen, Germany)

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

Energy Signal Tool for Decision Support in Building Energy Systems

A prototype energy signal tool is demonstrated for operational whole-building and system-level energy use evaluation. The purpose of the tool is to give a summary of building energy use which allows a building operator to quickly distinguish normal and abnormal energy use. Toward that end, energy use status is displayed as a traffic light, which is a visual metaphor for energy use that is either substantially different from expected (red and yellow lights) or approximately the same as expected (green light). Which light to display for a given energy end use is determined by comparing expected to actual energy use. As expected, energy use is necessarily uncertain; we cannot choose the appropriate light with certainty. Instead, the energy signal tool chooses the light by minimizing the expected cost of displaying the wrong light. The expected energy use is represented by a probability distribution. Energy use is modeled by a low-order lumped parameter model. Uncertainty in energy use is quantified by a Monte Carlo exploration of the influence of model parameters on energy use. Distributions over model parameters are updated over time via Bayes' theorem. The simulation study was devised to assess whole-building energy signal accuracy in the presence of uncertainty and faults at the submetered level, which may lead to tradeoffs at the whole-building level that are not detectable without submetering.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FECM/NETL Natural Gas with Hydrogen Pipeline Cost Model (2024): Description and User’s Manual

This is the user’s manual for The FECM/NETL Natural Gas with Hydrogen Pipeline Cost Model (NG-H2_P_COM) that estimates costs for transporting gaseous hydrogen with natural gas in a pipeline from a source, such as a hydrogen production facility, to a final destination which may be a user of the hydrogen and natural gas or a distribution center where hydrogen in the pipeline with natural gas is diverted to multiple end users. This user’s manual provides two main functions. First, the detailed statement describes the equations and algorithms that are used by the model to calculate technical quantities (such as blend hydrogen percentage, reuse percentage of the pipeline and stations, the pipe diameter size and length needed to transport a user-specified hydrogen with natural gas rate in a specified distance) and engineering-economic quantities (such as capital costs, operating costs, and cash flows). Second, the document is a user’s manual for the model that describes the procedures the user must follow to configure and setup the model, run the model, analyze the results, and visualize the outcomes. Such details offer user a quick and handy way to utilize the model for their application and decision making. The model can be accessed at this URL: https://www.netl.doe.gov/energy-analysis/details?id=cf3f6564-3c55-4aa5-b712-7160e558d9f6. The Model Results and Comparative Analysis can be accessed here: https://www.netl.doe.gov/energy-analysis/details?id=83862799-a28c-4944-a809-90b7e23d4af6.

03 NATURAL GAS↗

A rapid, pulsed laser testing approach for single event latch-up screening in microelectronics

A pulsed laser testing system for rapid screening of single-event latch-up (SEL) in microelectronics with real-time visualization of sensitive nodes via photo-emission is presented. We provide a detailed overview of the system, followed by SEL threshold measurements in an analog-to-digital converter (AD9240). We find that SEL thresholds are comparable to measurements taken with a low-repetition rate, fixed beam system, and demonstrate full-die scanning speeds can be an order of magnitude faster

Andrus, Liam Padraic↗

Data for "Divergent urban land trajectories under alternative population projections within the shared socioeconomic pathways"

Datasets supporting findings and visualizations behind McManamay et al. (2024) Divergent urban land trajectories under alternative population projections within the shared socioeconomic pathways. Environmental Research Letters, DOI: 10.1088/1748-9326/ad2eec Using a spatial modeling experiment at high resolution (1-km), this study compared how two alternative US population projections, varying in the spatially explicit nature of demographic patterns and migration, affect urban land dynamics simulated by the Spatially Explicit, Long-term, Empirical City development (SELECT) model for SSP2, SSP3, and SSP5. The numerical experiment, inputs and outputs are fully described in McManamay et al. (2024). The datasets summarize SELECT model simulations within urban areas and rural areas of the conterminous United States. For code to reproduce the results, please refer to https://github.com/IMMM-SFA/mcmanamay_etal_2024_erl Please refer to the README file provided in Files for more details. Descriptions of the datasets are provided below. Dataset(s) Descriptions: Urban_Land_delta_UA_County.csv: Urban land area for original (default) population, updated population, and urban land delta (difference between the two) according to Shared Socioeconomic Pathways (SSPs) and year. Urban land is summarized for U.S. counties (FIPS code) and urban areas (GEOID) as unique areas within various counties. JO_Gao_pop_ufdelta.csv: Comparison of population differences and urban land differences between the origial (default) and updated population projections. City_Case_studies.csv: Differences in urban land areas arising from different population projections summarized for selected cities (Atlanta, Los Angeles, Houston, and New York) and their surrounding rural areas UA_county_FID.zip: Zipped folder of .tiff file depicting unique combination of urban areas and US counties used for summarizing urban land differences in urban and rural areas based on different population projections. ULD_clusters.zip: Zipped folder of .csv files depicting normalized changes in urban land delta (difference in urban land arising from population projections) and the respective Ward's hierarchical clusters, which group urban and rural areas based on similarities in temporal trends. Urban_Percent_change_2100.zip: Zipped folder of .csv files depicting percent changes in urban land area for year 2100 based on differences in the original (default) population and updated population. Each file is for SSPs and urban or rural areas.

Land↗