Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Closed‐loop hierarchical control strategies for connected and autonomous hybrid electric vehicles with random errors

This study presents a closed‐loop hierarchical control strategy for a group of connected and autonomous hybrid electric vehicles (HEVs) with the purpose of optimising fuel economy while guaranteeing traffic mobility and vehicle safety. In the hierarchical control architecture, a decentralised stochastic model predictive control (SMPC)‐based higher level controller incorporating signal phase and timing information is formulated to optimise the velocity profile of each vehicle, and an adaptive equivalent consumption minimisation strategy based lower level controller is employed for the energy management control of the HEVs. Creatively, random errors of the control variable are considered in the SMPC framework. The errors are discretised and modelled as a Markov process and the state transition matrix of the errors is generated randomly to capture the error transition dynamics. To solve the SMPC problem more efficiently, a scenario‐based SMPC is employed. Moreover, the propulsion and recuperation efficiencies of the lower level controller are calculated at each time step with measurable variables, and fed back to the higher level controller for velocity optimisation in next time step. Simulation results validate the control effectiveness and advantages of the proposed control architecture.

Qiu, Shaolin↗

Use of intrinsic hysteresis for the active control of internal transport barriers in magnetically confined fusion plasmas

In magnetically confined fusion devices, control of internal transport barriers (ITBs) is important both to enhance and suppress the turbulent transport to improve confinement control. Barrier control should allow for the improvement of confinement to aid in achieving the needed fusion criteria while also permitting the degradation of confinement to control profiles and clean the device by moving out the impurities accumulated near the core. In this work, we present a novel control scenario that takes advantage of the hysteresis intrinsic to transport barriers to easily cycle through enhanced and degraded confinement regimes. The control scenario is illustrated using a five-field simplified transport model for an ITB using typical parameters of a neutral beam injection-heated DIII-D tokamak discharge. Pellets and ion cyclotron resonance frequency power are used as control knobs for this active control scenario. These knobs adequately modify at will the local gradients and, therefore, the growth rates and shearing rates, allowing for easy and efficient control of the barrier by taking advantage of the barrier hysteresis. The result is a control cycle that could be operated with a relatively small amount of power in high performance regimes which, nowadays, typically require large power to control. It may also have advantages to avoid, or at least ameliorate, the appearance of magnetohydrodynamic instabilities in the barrier region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plasma Modeling Results and shape control improvements for NSTX

New control implementations and dynamics studies on the National Spherical Torus eXperiment (NSTX) are summarized. In particular, strike point (SP) position, X-point height and squareness control, and two new system-identification methods / control-tuning algorithms were put into operation.The PID controller for the SP was tuned by analyzing the step response of the SP position to the poloidal coil currents, employing the Ziegler-Nichols method. The resulting SP controller was successfully employed to achieve the “snowflake” divertor configuration in NSTX. An offline system identification of the plasma response to the control inputs based on ARMAX input-output models was implemented. With this tool, rough estimates of the improvements were realized and several control improvements were identified.An online automatic relay-feedback PID tuning algorithm was implemented, which has the advantage of tuning the controller in one shot, thus optimizing the use of experimental time. Furthermore, using these new capabilities, we implemented LLD scenarios with control for theall four upper/lower/inner/outer SPs and with a combined X-point height, SP radius control. Separately, an independent squareness control was implemented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and simulation of the snowflake divertor control for NSTX-U

This study presents the development of a physics-based multiple-input-multiple-output algorithm for real-time feedback control of snowflake divertor (SFD) configurations on the National Spherical Torus eXperiment Upgrade (NSTX-U). A model of the SFD configuration response to applied voltages on the divertor control coils is first derived and then used, in conjunction with multivariable control synthesis techniques, to design an optimal state feedback controller for the configuration. To demonstrate the capabilities of the controller, a nonlinear simulator for axisymmetric shape control was developed for NSTX-U which simultaneously evolves the currents in poloidal field coils based upon a set of feedback-computed voltage commands, calculates the induced currents in passive conducting structures, and updates the plasma equilibrium by solving the free-boundary Grad-Shafranov problem. Closed-loop simulations demonstrate that the algorithm enables controlled operations in a variety of SFD configurations and provides capabilities for accurate tracking of time-dependent target trajectories for the divertor geometry. In particular, simulation results suggest that a time-varying controller which can properly account for the evolving SFD dynamical response is not only desirable but necessary for achieving acceptable control performance. The algorithm presented in this paper has been implemented in the NSTX-U Plasma Control System in preparation for future control and divertor physics experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Validation of Control Bands Using Bayesian Statistical Analyses

Abstract This study presents a quantitative validation of 15 Similar Exposure Groups (SEGs) that were derived via control bands inherent to the Risk Level Based Management System currently being used at the Lawrence Livermore National Laboratory. For 93% of the SEGs that were evaluated, statistical analyses of personal exposure monitoring data, through Bayesian Decision Analysis (BDA), demonstrated that the controls implemented from the initial control bands assigned to these SEGs were at least as protective as the controls from the control band outcomes derived from the quantitative data. The BDA also demonstrated that for 40% of the SEGs, the controls from the initial control bands were overly protective, thus allowing controls to be downgraded, which resulted in a significant saving of environmental safety and health (ES&H) resources. Therefore, as a means to both confirm existing controls and to identify candidate SEGs for downgrading controls, efforts to continuously improve the accuracy of Control Banding (CB) strategies through the routine quantitative validation of SEGs are strongly encouraged. Targeted collaborative efforts across institutions and even countries for both the development of CB strategies and the validation of discreetly defined SEGs of commonly performed tasks will not only optimize limited ES&H resources but will also assist in providing a simplified process for essential risk communication at the worker level to the benefit of billions of workers around the world.

McCord, Tyler A.↗

Adaptive PID Gain Scheduling Control for Hydropower Turbine Using Neural CDE and Stochastic Distribution Shaping

This paper introduces a gain-scheduling PID controller design strategy for hydroturbine frequency control mode. This scheme first uses real data to learn the nonlinear dynamics of the hydroturbine using neural controlled differential equations and then perturbs the obtained nonlinear system at different equilibrium points, based on which a static output feedback adaptive dynamic programming algorithm is then used to optimize the PID gains for each equilibrium point. Moreover, a continuous-time version of stochastic distribution control is proposed to further fine-tune the optimized PID gains. Finally, the controller is obtained by implementing linear interpolation between the optimized PID control gains. The simulation results show that the proposed gain-scheduling PID controller can control a larger range of operation points compared with the given fixed PID controller and the baseline method. Compared with the given fixed PID controller, the proposed gain-scheduling PID controller can regulate hydroturbine frequency against disturbances induced by power-load variation with over 50% less overshoot for some operation points.

13 HYDRO ENERGY↗

Distributed Control of Inverter-Interfaced Microgrids Based on Consensus Algorithm with Improved Transient Performance

Conventional control solutions of the inverter-interfaced microgrids are usually designed based on models with fully decoupled subsystems. The negligence of the strong coupling due to power lines impedance leads to large transient line currents, which might trigger false protection. Besides, the droop-based control methods unnecessarily introduce system frequency and voltage deviations. To overcome these issues, a novel distributed control scheme is proposed for the inverter-interfaced microgrids in this study. The objective of the primary control is to regulate the bus voltages and frequency while suppressing the transient line currents. The objective of secondary control is to maintain fair load sharing. Both primary control and secondary control are distributed and subsystems or control agents only require measurements from local and neighboring subsystems. The detailed control problem formulation, control design and stability analysis are presented in the paper. Finally, the effectiveness of the proposed control solution is evaluated through extensive simulations based on both simplified and detailed models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Traffic Prediction for Merging Coordination Control in Mixed Traffic Scenarios

Connected and autonomous vehicles (CAVs) have the potential to bring in safety, mobility, and energy benefits to transportation. The control decisions of CAVs are usually determined for a look-ahead horizon based on previewed traffic information. This requires an effective prediction of future traffic conditions and its integration with the CAV control framework. However, the short-term traffic prediction using information from connectivity is a challenging research topic, especially for mixed traffic scenarios. This work focuses on the development of a traffic prediction framework for a merging coordination controller. The previously developed merging controller coordinates the merging sequence and travel speed of CAVs to maximize the energy efficiency and overall mobility. In mixed traffic scenarios, the controller receives information regarding the position of all the vehicles traveling inside a control zone and controls the desired speed of all CAVs. The controller has no control on the human-driven vehicles. The merging controller does not have direct information or an explicit prediction on the behaviors of human-driven vehicles. Aiming to improve the performance of the merging controller in various mixed traffic conditions, a traffic prediction algorithm is developed and evaluated in this work. The performance of this traffic prediction algorithm is investigated for various penetration rates of connectivity for a single-lane secondary road merging to a single-lane primary road. The results show that compared to a constant speed assumption of human-driven vehicles, the proposed traffic prediction algorithm is able to reduce the prediction error of the arrival time of human-driven vehicles at the merging zone by more than 50%.

Shao, Yunli↗

Fuel-Based Nash Bargaining Approach for Adaptive Signal Control in an N -Player Cooperative Game

This paper presents a fuel-based game-theoretic approach for adaptive signal control. Our controller applies Nash bargaining (NB) in an n-player cooperative game to identify optimal phasing splits considering future traffic demands. The fuel-based NB controller utilizes an objective function that combines operational measures (delays and stops) with fuel consumption measures at intersections. The proposed controller was encoded in Python and then implemented and evaluated in a VISSIM microscopic traffic simulation model in an intersection with increasing volumes. The performance of the NB controller was compared to a traditional actuated control as the baseline. The results show that the NB controller was able to achieve superior environmental gains with a 17% saving in fuel consumption and a 17% reduction in CO emissions. In addition, the proposed controller was capable of maintaining acceptable operational conditions as it achieved a 20% reduction in delay, 8% reduction in the number of stops, and 8% reduction in queue lengths compared to the actuated controller. Compared to similar studies that applied NB for adaptive signal control, our fuel-based NB controller stands out as a promising approach to significantly improve fuel consumption at signalized intersections.

Engineering↗

Optimal Control by Transfer-Learning

Through the project, a transfer-learning based optimal control methodology was developed. This can significantly reduce the time and data required for model learning and increase operation robustness and resilience via data-driven controller optimization. This methodology includes three major elements: 1) extraction of control knowledge or knowledge of tuning control parameter from a source feedback control task; 2) transferring of control knowledge from the source control task to a target control task (initialization of control parameters for the target control task); and 3) fast-adaptation of control parameters for the target task to achieve optimized performance.

42 ENGINEERING↗

Advanced Communication and Control for Distributed Energy Resource Integration: Phase 2 Scientific Report

The objective of this research project is to demonstrate sensing, communication, information and control technologies to achieve a seamless integration of multivendor distributed energy resource (DER) units at aggregation levels that meet individual user requirements for facility operations (residential, commercial, industrial, manufacturing, etc.) and further serve as resource options for electric and natural gas utilities. The fully demonstrated DER aggregation system with embodiment of communication and control technologies will lead to real-time, interactive, customer-managed service networks to achieve greater customer value. Work on this Advanced Communication and Control Project (ACCP) consists of a two-phase approach for an integrated demonstration of communication and control technologies to achieve a seamless integration of DER units to reach progressive levels of aggregated power output. Phase I involved design and proof-of-design, and Phase II involves real-world demonstration of the Phase I design architecture. The scope of work for Phase II of this ACCP involves demonstrating the Phase I design architecture in large scale real-world settings while integrating with the operations of one or more electricity supplier feeder lines. The communication and control architectures for integrated demonstration shall encompass combinations of software and hardware components, including: sensors, data acquisition and communication systems, remote monitoring systems, metering (interval revenue, real-time), local and wide area networks, Web-based systems, smart controls, energy management/information systems with control and automation of building energy loads, and demand-response management with integration of real-time market pricing. For Phase II, BPL Global shall demonstrate the Phase I design for integrating and controlling the operation of more than 10 DER units, dispersed at various locations in one or more Independent System Operator (ISO) Control Areas, at an aggregated scale of more than 1 MW, to provide grid support. Actual performance data with respect to each specified function above is to be collected during the Phase II field demonstration. At a minimum, the Phase II demonstration shall span one year of field operations. The demonstration performance will need to be validated by the target customer(s) for acceptance and subsequent implementation. An ISO must be involved in demonstration planning and execution. As part of the Phase II work, BPL Global shall develop a roadmap to commercialization that identifies and quantifies the potential markets for the integrated, aggregated DER systems and for the communication and control technologies demonstrated in Phase I. In addition, the roadmap must identify strategies and actions, as well as the regional and national markets where the aggregated DER systems with communication and control solutions will be introduced, along with a timeline projected for introduction into each identified market. In Phase I of this project, we developed a proof-of-concept ACCP system and architecture and began to test its functionality at real-world sites. These sites had just over 10 MW of DERs and allowed us to identify what needed to be done to commercialize this concept. As a result, we started Phase II by looking at our existing platform and identified its strengths and weaknesses as well as how it would need to evolve for commercialization. During this process, we worked with different stakeholders in the market including: Independent System Operators, DER owners and operators, and electric utility companies to fully understand the issues from all of the different perspectives. Once we had an understanding of the commercialized ACCP system, we began to document and prepare detailed designs of the different system components. The components of the system with the most significant design improvements were: the on-site remote terminal unit, the communication technology between the remote site and the data center, and the scalability and reliability of the data center application. As we began to implement the Phase II ACCP system, we upgraded the real-world demonstration sites from Phase I of the project as well as added additional sites to broaden the types of DER the platform was tested with. We worked with the owners and operators of these sites to understand how the system was meeting their needs and made modifications throughout the project as needed. This also included an effort to continue to understand the barriers to commercial adoption of the ACCP architecture and standardized communication protocols. The final aspect of this phase of the project was to prepare resources to aid in the commercial adoption of the ACCP architecture and standardized communication protocols. This entailed: presentations at conferences, published articles and papers, and web-based technical resources to provide tools to aid in the design and implementation of ACCP systems.

03 NATURAL GAS↗

Model predictive control system and method for integrated gasification combined cycle power generation

Control system and method for controlling an integrated gasification combined cycle (IGCC) plant are provided. The system may include a controller coupled to a dynamic model of the plant to process a prediction of plant performance and determine a control strategy for the IGCC plant over a time horizon subject to plant constraints. The control strategy may include control functionality to meet a tracking objective and control functionality to meet an optimization objective. The control strategy may be configured to prioritize the tracking objective over the optimization objective based on a coordinate transformation, such as an orthogonal or quasi-orthogonal projection. A plurality of plant control knobs may be set in accordance with the control strategy to generate a sequence of coordinated multivariable control inputs to meet the tracking objective and the optimization objective subject to the prioritization resulting from the coordinate transformation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A simulation-based study on different control strategies for variable speed pump in distributed ground source heat pump systems

Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional control strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual synchronous generator system and method with virtual inertia control

A virtual synchronous generator device disclosed. The device includes an inverter and inverter controller having a power control portion, a power reserve portion, a power point tracking control portion, and a virtual inertia control portion. The power reserve portion determines an amount of power to be reserved and sends a signal, indicative of the determined amount of power to the power point tracking controller. The power point tracking controller determines a power point that is less than a MPP, and provides a signal to the power control portion indicative of the determined power point. The inertia control portion determines a virtual inertia and provides a signal indicative of the virtual inertia to the power control portion. The power control portion provides a power control signal to the inverter based on the power point tracking signal and the inertia command signal.

42 ENGINEERING↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗