Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Thermal Feedback in the High-mass Star- and Cluster-forming Region W51

High-mass stars have generally been assumed to accrete most of their mass while already contracted onto the main sequence, but this hypothesis has not been observationally tested. We present ALMA observations of a 3×1.5 pc area in the W51 high-mass star-forming complex. We identify dust continuum sources and measure the gas and dust temperature through both rotational diagram modeling of CH{sub 3}OH and brightness-temperature-based limits. The observed region contains three high-mass YSOs that appear to be at the earliest stages of their formation, with no signs of ionizing radiation from their central sources. The data reveal high gas and dust temperatures (T>100 K) extending out to about 5000 au from each of these sources. There are no clear signs of disks or rotating structures down to our 1000 au resolution. The extended warm gas provides evidence that, during the process of forming, these high-mass stars heat a large volume and correspondingly large mass of gas in their surroundings, inhibiting fragmentation and therefore keeping a large reservoir available to feed from. By contrast, the more mature massive stars that illuminate compact H II regions have little effect on their surrounding dense gas, suggesting that these main-sequence stars have completed most or all of their accretion. The high luminosity of the massive protostars (L>10{sup 4} L{sub ⊙}), combined with a lack of centimeter continuum emission from these sources, implies that they are not on the main sequence while they accrete the majority of their mass; instead, they may be bloated and cool.

79 ASTRONOMY AND ASTROPHYSICS↗

Sealion Database: Tracking and Characterization of Legacy Wastes

The Radioactive Scrap and Waste Facility Liner-by-Liner Characterization Project was initiated to support waste management planning and disposition activities at the Materials and Fuels Complex located at the Idaho National Laboratory. The project scope consisted of a detailed examination of available historical records to consolidate information and eliminate discrepancies between sources. This information was captured in a new comprehensive searchable online database dubbed Sealion (Searchable Liner Online). For each storage liner and associated waste container, Sealion tracks the physical configuration, radiological data (e.g., source term, transuranic content, fissile content, and direct gamma radiation reading), Resource Conservation and Recovery Act characterization data, contents descriptions, and a variety of other waste management data. Historical hard-copy records were scanned and are stored in the database for easy access. In addition to storing the consolidated data in a library for easy retrieval or linking, Sealion serves as a tool in the development of batching plans for retrieving, transporting, processing, and, ultimately, dispositioning the waste. An integral search function allows the user to query for a variety of parameters in order to plan custom batches and account for facility or regulatory limitations (e.g., U.S. Department of Transportation limits, hazard category determinations, and fissile gram equivalent limitations). Liners can be combined or batched together and the combined results displayed in real-time graphs and tables showing the cumulative characteristics. The basic database architecture has proven to be adaptable to a variety of other similar applications. Sealion is capable of tracking segmented inventories (i.e., the liners can be replaced with storage drums, racks in a warehouse, or grids overlaid on a landfill). Additionally, the batching functions allow for the ability to combine inventory sub-locations into real-time graphs that summarize the characteristics of the contents for ease in comparison of characteristics to established thresholds or decision-making modeling needed to support waste-management operations.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Soil Vapor Extraction Data to Evaluate Mass-Transfer Constraints and Estimate Source-Zone Mass Flux

Methods are developed to use data collected during cyclic operation of soil vapor extraction (SVE) systems to help characterize the magnitudes and timescales of mass flux associated with vadose zone contaminant sources. Operational data collected at the Department of Energy’s Hanford site are used to illustrate the use of such data. An analysis was conducted of carbon tetrachloride vapor concentrations collected during and between SVE operations. The objective of the analysis was to evaluate changes in concentrations measured during periods of operation and non-operation of SVE, with a focus on quantifying temporal dynamics of the vadose zone contaminant mass flux, and associated source strength. Three mass-flux terms, representing mass flux during the initial period of a SVE cycle, during the asymptotic period of a cycle, and representing mass flux during the rebound periods, were calculated and compared. It was shown that it is possible to use the rebound data to estimate time frames for effective operation of an SVE system if a sufficient set of historical cyclic operational data exists. This information could then be used to help evaluate changes in SVE operations, including system closure.

54 ENVIRONMENTAL SCIENCES↗

The Source Physics Experiment (SPE) Science Plan (Version 2.4c)

The Source Physics Experiment (SPE) series is a long-term NNSA research and development effort designed to improve U.S. arms control and nuclear nonproliferation verification and monitoring capabilities. The findings from the SPE will advance the United States’ nuclear explosion monitoring capabilities, particularly with respect to detection, discrimination and determination of yields associated with small nuclear explosions that can be lost amid the noisy seismo-acoustic background from other sources. The data generated from the SPE, a series of well-designed and recorded chemical explosions, will contribute to the development and validation of first-principles explosive source generated seismo-acoustic modeling codes. These codes will then facilitate the update of semi-empirical methods, currently based on historic test site data, such that key explosion observables can be reproduced, thus improving confidence in nuclear test monitoring in new areas and/or under novel emplacement conditions. The overall SPE project is comprised of both the development of the new explosion simulation codes and the chemical explosion test series. The chemical explosion test series will generate the empirical data required to both develop and validate the new simulation codes.

58 GEOSCIENCES↗

The Source Physics Experiment (SPE) Science Plan

The Source Physics Experiment (SPE) series is a long-term NNSA research and development effort designed to improve U.S. arms control and nuclear nonproliferation verification and monitoring capabilities. The findings from the SPE will advance the United States’ nuclear explosion monitoring capabilities, particularly with respect to detection, discrimination and determination of yields associated with small nuclear explosions that can be lost amid the noisy seismo-acoustic background from other sources. The data generated from the SPE, a series of well-designed and recorded chemical explosions, will contribute to the development and validation of first-principles explosive source generated seismo-acoustic modeling codes. These codes will then facilitate the update of semi-empirical methods, currently based on historic test site data, such that key explosion observables can be reproduced, thus improving confidence in nuclear test monitoring in new areas and/or under novel emplacement conditions. The overall SPE project is comprised of both the development of the new explosion simulation codes and the chemical explosion test series. The chemical explosion test series will generate the empirical data required to both develop and validate the new simulation codes.

58 GEOSCIENCES↗

Protein crystal structure from non-oriented, single-axis sparse X-ray data

X-ray free-electron lasers (XFELs) have inspired the development of serial femtosecond crystallography (SFX) as a method to solve the structure of proteins. SFX datasets are collected from a sequence of protein microcrystals injected across ultrashort X-ray pulses. The idea behind SFX is that diffraction from the intense, ultrashort X-ray pulses leaves the crystal before the crystal is obliterated by the effects of the X-ray pulse. The success of SFX at XFELs has catalyzed interest in analogous experiments at synchrotron-radiation (SR) sources, where data are collected from many small crystals and the ultrashort pulses are replaced by exposure times that are kept short enough to avoid significant crystal damage. The diffraction signal from each short exposure is so `sparse' in recorded photons that the process of recording the crystal intensity is itself a reconstruction problem. Using the EMC algorithm, a successful reconstruction is demonstrated here in a sparsity regime where there are no Bragg peaks that conventionally would serve to determine the orientation of the crystal in each exposure. In this proof-of-principle experiment, a hen egg-white lysozyme (HEWL) crystal rotating about a single axis was illuminated by an X-ray beam from an X-ray generator to simulate the diffraction patterns of microcrystals from synchrotron radiation. Millions of these sparse frames, typically containing only ~200 photons per frame, were recorded using a fast-framing detector. It is shown that reconstruction of three-dimensional diffraction intensity is possible using the EMC algorithm, even with these extremely sparse frames and without knowledge of the rotation angle. Further, the reconstructed intensity can be phased and refined to solve the protein structure using traditional crystallographic software. In conclusion, this suggests that synchrotron-based serial crystallography of micrometre-sized crystals can be practical with the aid of the EMC algorithm even in cases where the data are sparse.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A SEARCH FOR POINT SOURCES OF EeV NEUTRONS

A thorough search of the sky exposed at the Pierre Auger Cosmic Ray Observatory reveals no statistically significant excess of events in any small solid angle that would be indicative of a flux of neutral particles from a discrete source. The search covers from -90 Degree-Sign to +15 Degree-Sign in declination using four different energy ranges above 1 EeV (10{sup 18} eV). The method used in this search is more sensitive to neutrons than to photons. The upper limit on a neutron flux is derived for a dense grid of directions for each of the four energy ranges. These results constrain scenarios for the production of ultrahigh energy cosmic rays in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Lake-Effect Snowstorm Events and Associated Snowfall Totals Integrated from NOAA Storm Reports, ERA5, and HRRR for the Laurentian Great Lakes (1997–2024)

Lake-effect snowstorms are localized, impactful winter weather phenomena that can generate substantial snowfall totals and pose significant challenges for forecasting, transportation, and regional infrastructure. To support the analysis and modeling of these events, this dataset compiles observational reports of lake-effect snowstorms alongside corresponding snowfall estimates derived from gridded atmospheric datasets. The observational component of the data originates from the National Weather Service (NWS) winter storm report, subset to lake-effect snow event type, covering 1997–2024. For each lake-effect snow event, this data provides the impacted county, event start and end datetimes at an hourly resolution, as well as relevant storm narratives. The complementary reanalysis-derived data is sourced from European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis 5 (ERA5) and High-Resolution Rapid Refresh (HRRR) gridded data. For both gridded datasets, the maximum total snowfall (in units mm) was extracted, constrained by the county and datetimes specified by the observational report. ERA5 data covers the entire observational period (1997–2024), whereas HRRR data is only available from November 2016 – December 2024. Three CSV files are provided here: (1) the observational lake-effect snow event report, (2) ERA5 maximum snowfall detections for each event, and (3) HRRR maximum snowfall detections for each event. Relevant data from the observational files, such as impacted state and county, event datetimes, and event IDs, were included for convenience. Users can inspect and visualize the data using tools such as Microsoft Excel and Python pandas/matplotlib packages. This dataset may support a variety of applications, including climatological analyses of lake-effect snowfall, evaluation of snowfall representation in atmospheric datasets and numerical weather prediction models, and the development of machine learning approaches for detecting or predicting lake-effect snowfall events.

EARTH SCIENCE > ATMOSPHERE > PRECIPITATION > SOLID↗

Investigations of shot reproducibility for the SMP diode at 4.5 MV.

In experiments conducted on the RITS-6 accelerator, the SMP diode exhibits sig- ni cant shot-to-shot variability. Speci cally, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. To remove knob emission as a source, only data from a shot series conducted with a 4.5-MV peak voltage are considered. The scope of this report is limited to sources of variability which occur away from the diode, such as power ow emission and trajectory changes, variations in pulsed power, dustbin and transmission line alignment, and di erent knob shapes. We nd no changes in the transmission line hardware, alignment, or hardware preparation methods which correlate with impedance collapse. However, in classifying good versus poor shots, we nd that there is not a continuous spectrum of diode impedance behavior but that the good and poor shots can be grouped into two distinct impedance pro les. This result forms the basis of a follow-on study focusing on the variability resulting from diode physics. 3

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring and Numerical Modeling of Shallow CO 2 Injection, Greene County, Missouri

The project titled Monitoring and Numerical Modeling of Shallow CO 2 Injection, Greene County, Missouri provided training for three graduate students in areas related to carbon capture and storage. Numerical modeling of CO 2 injection into the St. Francois aquifer at the Southwest Power Plant Site in Greene County, Missouri indicates that up to 4.1 x 10 5 metric tons of CO 2 per year could be injected for 30 years without exceeding a 3 MPa differential injection pressure. The injected CO 2 would remain sequestered below the top of the overlying caprock (St. Francois confining unit) for more than 1000 years. Geochemical modeling indicates that portions of the injected CO 2 will react rapidly with trace minerals in the aquifer to form various solid carbonate mineral phases. These minerals would store significant portions of injected CO 2 over geologic time scales. Finally, a GIS data base on the pore-fluid chemistry of the overlying aquifer system in Missouri, the Ozark aquifer, was compiled from many sources. This data base could become useful in monitoring for leakage from future CO 2 sequestration sites.

54 ENVIRONMENTAL SCIENCES↗

Data Efficiency Assessment of Generative Adversarial Networks for Critical Heat Flux Synthetic Data Generation

This study investigates the application of generative artificial intelligence techniques, particularly conditional generative adversarial networks (cGAN), in real-world engineering contexts, with a specific focus on synthetic data generation for critical heat flux (CHF). Utilizing a dataset comprising more than 20,000 real experimental CHF measurements, we conduct a series of experiments to examine cGAN’s behavior. These experiments encompass varying sizes of the training dataset, training cGAN on data from diverse experimental sources to generate new data on unseen experimental setups, and assessing the impact of excluding various input features on cGAN’s data generation accuracy. Our findings underscore the pronounced data dependency of cGAN for reliable performance, with decreased efficacy observed with smaller training dataset sizes. Notably, cGAN exhibits varying performance when trained on data from different experiments, with superior predictive capabilities observed for certain experiment sources compared to others. For instance, when cGAN was trained on data from Smolin et al.’s experiments or Zenkevich et al., it exhibited relatively good performance in generating the data from Becker et al., Kirillov et al., and Alekseev et al. experiments. In contrast, when trained with Alekseev et al.’s data and tasked with generating other experimental setups, cGAN showed notably poor performance. In both scenarios, cGAN’s performance was inferior compared to training on samples from all experiments concurrently. A feature importance analysis highlights the significant influence of parameters such as mass flux and heated length on accurate CHF generation, while other parameters like diameter and pressure have less impact. Inlet temperature is identified as a moderating factor by cGAN.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and performance testing of a novel far field Gamma system to assay radioactive waste in 400 and 200 litre drums - 15339

A Far Field Gamma ray Measurement system has been developed for measuring and assaying both 400 and 200 litre waste drums with a wide range of activity at nuclear power stations. These include radioactive waste drums with surface dose-rates of less than 2 mSv/h (200 mrem/h) and, at the higher range of activity, 400 litre drums with surface dose-rates of up to 50 mSv/h (5 rem/h). The assay system incorporates an electro-mechanically cooled high purity Germanium profile detector and advanced digital spectroscopic analysis electronics. A novel optimised conical-trapezoidal collimator has been incorporated to reduce the effect of the radioactive background in addition to the conventional detector lead shield with tin and copper graded lining to reduce the effect of lead X-rays. Two features have been incorporated to reduce detector dead time and maintain detector resolution when measuring high activity drums. The first is the inclusion of two automated tungsten filters of different thickness as an integral part of the detector collimator. The filters are used in conjunction with an automated rail system on which the detector platform is mounted. The detector can be positioned at different distances from the drum surface in order to reduce detector dead time. The deployment of the filters and the adjustment of the drum - detector position are automatically controlled based on a user defined dose-rate limit table. The data is provided by two Geiger-Muller dose-rate detectors, which are used to measure the drum surface dose-rate. This data is subsequently used to adjust the detector position and in cases of higher dose-rate deploy one or other of the tungsten filters. The drum rotation platform incorporates a load cell to determine drum weight and hence the drum density. This information is used to calculate an attenuation correction based on the assumption of uniform drum density and uniform distribution of activity within the drum. Where the waste drums have a more complicated and known regular internal structure, such as a small radioactive region surrounded by an annulus of shielding material, the analysis algorithms incorporated into the far field geometry and attenuation correction spectroscopic data analysis code are able to make a more accurate determination of drum activity than would be possible assuming a completely uniform drum. The detector energy and efficiency calibration is achieved using a point source with multiple gamma ray energy peaks. The response of the high purity Germanium detector is also modelled using the Monte Carlo Neutron Photon code and the model is benchmarked using the measured point source calibration data. The performance of the instrument has been determined for a range of uniform density matrix drums containing a set of Eu-152 line or rod sources located in re-entrant tubes positioned on an equal volume basis. When rotated, the test drums with volume distributed line sources simulate waste drums of different density each with a uniformly distributed radioactive source. The measurements have been validated using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polarization and variability of compact sources measured in Planck time-ordered data

This paper introduces a new Planck Catalog of Polarized and Variable Compact Sources (PCCS-PV) comprising 153 sources, the majority of which are extragalactic. The data include both the total flux density and linear polarization measured by Planck with frequency coverage from 30 to 353 GHz, and temporal spacing ranging from days to years. We classify most sources as beamed, extragalactic radio sources; the catalog also includes several radio galaxies, Seyfert galaxies, and Galactic and Magellanic Cloud sources, including H II regions and planetary nebulae. An advanced extraction method applied directly to the multifrequency Planck time-ordered data, rather than the mission sky maps, was developed to allow an assessment of the variability of polarized sources. Our analysis of the time-ordered data from the Planck mission, tod2flux, allowed us to catalog the time-varying emission and polarization properties for these sources at the full range of polarized frequencies employed by Planck, 30-353 GHz. PCCS-PV provides the time-and frequency-dependent, polarized flux densities for all 153 sources. To illustrate some potential applications of the PCCS-PV, we conducted preliminary comparisons of our measurements of selected sources with published data from other astronomical instruments. In summary, we find general agreement between the Planck and the Institut de Radioastronomie Millimétrique (IRAM) polarization measurements as well as with the Metsähovi 37 GHz values at closely similar epochs. Here, these combined measurements also show the value of PCCS-PV results and the PCCS2 catalog for filling in missing spectral (or temporal) coverage and helping to define the spectral energy distributions of extragalactic sources. In turn, these results provide useful clues as to the physical properties of the sources.

79 ASTRONOMY AND ASTROPHYSICS↗

MODEL-INDEPENDENT X-RAY MASS DETERMINATIONS

A new method is introduced for making X-ray mass determinations of spherical clusters of galaxies. Treating the distribution of gravitating matter as piecewise constant and the cluster atmosphere as piecewise isothermal, X-ray spectra of a hydrostatic atmosphere are determined up to a single overall normalizing factor. In contrast to more conventional approaches, this method relies on the minimum of assumptions, apart from the conditions of hydrostatic equilibrium and spherical symmetry. The method has been implemented as an XSPEC mixing model called CLMASS, which was used to determine masses for a sample of nine relaxed X-ray clusters. Compared to conventional mass determinations, CLMASS provides weak constraints on values of M{sub 500}, reflecting the quality of current X-ray data for cluster regions beyond r{sub 500}. At smaller radii, where there are high quality X-ray spectra inside and outside the radius of interest to constrain the mass, CLMASS gives confidence ranges for M{sub 2500} that are only moderately less restrictive than those from more familiar mass determination methods. The CLMASS model provides some advantages over other methods and should prove useful for mass determinations in regions where there are high quality X-ray data.

79 ASTRONOMY AND ASTROPHYSICS↗

CO2 pipeline data catalog

This "Data Catalog" is an excel spreadsheet of collected and catalogued spatial and non-spatial public datasets in relevance to and support of CO2 transport (pipelines) infrastructure development and risk modeling. Includes data associated with CO2 sources, sinks, and transportation.

CO2↗

ACToR - Aggregated Computational Toxicology Resource

ACToR (Aggregated Computational Toxicology Resource) is a database and set of software applications that bring into one central location many types and sources of data on environmental chemicals. Currently, the ACToR chemical database contains information on chemical structure, in vitro bioassays and in vivo toxicology assays derived from more than 150 sources including the U.S. Environmental Protection Agency (EPA), Centers for Disease Control (CDC), U.S. Food and Drug Administration (FDA), National Institutes of Health (NIH), state agencies, corresponding government agencies in Canada, Europe and Japan, universities, the World Health Organization (WHO) and non-governmental organizations (NGOs). At the EPA National Center for Computational Toxicology, ACToR helps manage large data sets being used in a high-throughput environmental chemical screening and prioritization program called ToxCast{sup TM}.

60 APPLIED LIFE SCIENCES↗

Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis

We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge ({approx}285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗