Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

X-ray observations of filament eruption in the 1980 May 21 flare

X-ray and H-alpha observations of an erupting filament and other observations of the associated flare on May 21, 1980 suggest that an erupting filament played a major role in the X-ray flare. While Antonucci et al. (1985) analyzed the May 21 flare as one of the best cases of chromospheric evaporation, the possible contribution from X-ray emitting erupting plasma has been ignored. It is that preheated plasma existed and may have contributed part of the blue-shifted X-ray emission observed in the Ca XIX line, which was formerly attributed solely to chromospheric evaporation. Thus it remains an open question - in two-ribbon flares in particular - just how important chromospheric evaporation is in flare dynamics.

Batchelor, D. A.↗

Crystallization, sublimation, and gas release in the interior of a porous comet nucleus

A numerical code is developed for evolutionary calculations of the thermal structure and composition of a porous comet nucleus made of water ice, in amorphous or crystalline form, other volatiles, dust, and gases trapped in amorphous ice. Bulk evaporation, crystallization, gas release, and free (Knudsen) flow of gases through the pores are taken into account. The numerical scheme yields exact conservation laws for mass and energy. The code is used to study the effect of bulk evaporation of ice in the interior of a comet nucleus during crystallization. It is found that evaporation controls the temperature distribution; the vapor prevents cooling of the crystallized layer of ice, by recondensation and release of latent heat. Thus high temperatures are maintained below the surface of the nucleus and down to depths of tens or hundreds of meters, even at large heliocentric distances, as long as crystallization goes on. Gas trapped in the ice and released during the phase transition flows both toward the interior and toward the surface and out of the nucleus. The progress of crystallization is largely determined by the contribution of gas fluxes to heat transfer.

Prialnik, Dina↗

Global aspects of the Los Alamos general circulation model hydrologic cycle

The global hydrologic cycle in the Los Alamos general circulation model (GCM) is compared to available global observations. Global observations of the water vapor, water-vapor flux and water-vapor flux divergence are derived from the National Meteorological Center's final analysis for the period 1986-1989. The new precipitation data set of Legates and Willmott (1990) is used for the global precipitation observations. Global evaporation is derived as a residual of the precipitation and water-vapor flux divergence. There are a number of similarities as well as discrepancies between the GCM and observations. The large-scale nondivergent and divergent GCM circulations are remarkably similar to the observed circulations; the large-scale GCM precipitation and evaporation patterns are also qualitatively similar to observations. Discrepancies are mainly quantitative and small-scale in nature: the GCM atmosphere is relatively dry which results in a slightly greater evaporation and precipitation rate than is observed; the GCM South Pacific convergence zone is displaced too far to the northwest.

Roads, J. O.↗

Experimental investigation of freezing blowby in a copper/water heat pipe

An experimental investigation designed to evaluate and better define the overall characteristics of freezing blowby in a copper/water heat pipe was conducted. The results from various rates of restart heat addition and channel blockage, indicate that upon breakthrough the depressurization of the evaporator may result in an effective heat transport capacity far in excess of the steady-state transport limit. The resulting transient conditions imposed on the heat pipe by the effective increased heat transport capacity can cause a loss of liquid in the evaporator and potential dryout. Evidence is presented which indicates that in order to prevent either temporary or permanent dryout, sufficient liquid inventory must be present in the evaporator wicking structure to accommodate the increased transient thermal load and allow sufficient time for the capillary wicking structure to reprime.

Ochterbeck, J. M.↗

Frozen start-up behavior of low-temperature heat pipes

Start-up and subsequent operation of a low-temperature heat pipe requires the liquid phase of the operating fluid to be continuously pumped back to the evaporator by the capillary action of the wick. If the pipe has been in an environment where ambient temperatures are below the freezing point of the working fluid prior to start-up, the frozen fluid in the condenser and adiabatic region scan prevent initial flow to the evaporator, causing dryout of the evaporator before all of the working fluid is in the liquid phase. This paper examines the time-dependent wall and vapor temperature profiles along the axial length of a low-temperature heat pipe during start-up from the frozen state, and freeze-out during a normal operation by applying a subfreezing temperature fluid through the condenser. In addition, the experimental transient frozen start-up wall temperature profile is compared with a two-dimensional numerical phase-change model. A successful start-up method using a pulsed power input is presented.

Faghri, Amir↗

Two phase capillary pumped heat transfer in the Instrument Thermal Test Bed

An experimental study of the thermal performance of two evaporators installed in the Instrument Thermal Test Bed (ITTB) was conducted. The ITTB was operated as a capillary pumped loop (CPL) with a transport length of approximately 12 meters. Empirical determinations of a general start up procedure, overall heat transfer coefficient, and minimum operating power were accomplished for each evaporator. Additionally, a detailed thermal model was developed for the High Power Spacecraft Thermal Management (HPSTM) evaporator and validated.

Didion, Jeffrey R.↗

Device For Controlling Crystallization Of Protein

Variable sandwich spacer enables optimization of evaporative driving force that governs crystallization of protein from solution. Mechanically more rigid than hanging-drop and sitting-drop devices. Large oscillations and dislodgment of drop of solution in response to vibrations suppressed by glass plates. Other advantages include: suitable for automated delivery, stable handling, and programmable evaporation of protein solution; controlled configuration enables simple and accurate determination of volume of solution without disrupting crystallization; pH and concentration of precipitant controlled dynamically because pH and concentration coupled to rate of evaporation, controllable via adjustment of gap between plates; and enables variation of ratio between surface area and volume of protein solution. Alternative version, plates oriented vertically instead of horizontally.

Noever, David A.↗

Stardust: Studies in microgravity of condensation and agglomeration of cosmic dust analogue

A short description of the program Stardust whose goal is to study the formation and properties of high temperature particles and gases, including silicate and carbonaceous materials, that are of interest in astrophysics and planetary science, is given. The international program was carried out in microgravity conditions in parabolic flight. A description of the laboratory equipment, conceived to perform experimental tests in reduced gravity conditions, and which is based on the gas evaporation technique, is given. The gas evaporation technique utilizes one or more heated crucible to vaporize solids materials (SiO, Mg) in a low pressure of inert or reactive gas inside of a vacuum bell jar. The vapor pressures of the materials are controlled by the temperature of the crucibles. The temperature and pressure of inert gas are also controlled. By varying the vapor pressure relative to the gas temperature and pressure, the conditions for substantial grain condensation can be controlled and grain formation measured using light scattering techniques. Thus the partial pressure for grain condensation, can be measured as a function of temperature. The gas evaporation technique has the advantage that complex chemical systems can be studied by using multiple crucibles each containing solid source material. Experimental results and future trends are addressed.

Ferguson, F.↗

Variation in energy balance components from six sites in a native prairie for three years

Six automatic stations were used to evaluate the surface energy and radiation balances on a native prairie near Manhattan, Kansas, using the Bowen ratio technique for a total of 300 days. Data were taken during the periods from May 26 to October 16, 1987, May 10 to September 18, 1988, and July 21 to August 13, 1989. The station site locations were selected to represent burned and unburned treatments on ridges, valley bottoms, and slopes with various aspects. The measured variables were (1) air and wet bulb temperatures at two heights, (2) net radiation, (3) solar radiation (up and down), (4) total hemispherical radiation (up and down), (5) diffuse radiation, (6) soil heat flow and soil temperature, (7) wind speed, (8) wind direction, and (9) precipitation. Energy balance components at the sites were compared for the 3 years. The variation between sites and years was small, even though some sites were as much as 10 km apart and the years had different rainfall amounts. The average values for the four summer intensive field campaigns (IFCs) were as follows: albedo, 0.2; ratio of net radiation to solar radiation, 62 percent; evaporation equivalent, 4 mm/d; Bowen ratio, 0.32; evaporation fraction, 70 percent; and the ratio of evaporation to solar energy, 40 percent. These values were different for the fall IFC. The latent and sensible heat fluxes were more variable than the radiation terms reflecting soil moisture differences between IFCs.

Fritschen, Leo J.↗

A catchment scale water balance model for FIFE

A catchment scale water balance model is presented and used to predict evaporation from the King's Creek catchment at the First ISLSCP Field Experiment site on the Konza Prairie, Kansas. The model incorporates spatial variability in topography, soils, and precipitation to compute the land surface hydrologic fluxes. A network of 20 rain gages was employed to measure rainfall across the catchment in the summer of 1987. These data were spatially interpolated and used to drive the model during storm periods. During interstorm periods the model was driven by the estimated potential evaporation, which was calculated using net radiation data collected at site 2. Model-computed evaporation is compared to that observed, both at site 2 (grid location 1916-BRS) and the catchment scale, for the simulation period from June 1 to October 9, 1987.

Famiglietti, J. S.↗

A bi-directional two-phase/two-phase heat exchanger

This paper describes the design and test of a heat exchanger that transfers heat from one two-phase thermal loop to another with very small drops in temperature and pressure. The heat exchanger condenses the vapor in one loop while evaporating the liquid in the other without mixing of the condensing and evaporating fluids. The heat exchanger is bidirectional in that it can transfer heat in reverse, condensing on the normally evaporating side and vice versa. It is fully compatible with capillary pumped loops and mechanically pumped loops. Test results verified that performance of the heat exchanger met the design requirements. It demonstrated a heat transfer rate of 6800 watts in the normal mode of operation and 1000 watts in the reverse mode with temperature drops of less than 5 C between two thermal loops.

Ku, Jentung↗

Comparison between the land surface response of the ECMWF model and the FIFE-1987 data

An averaged time series for the surface data for the 15 x 15 km FIFE site was prepared for the summer of 1987. Comparisons with 48-hr forecasts from the ECMWF model for extended periods in July, August, and October 1987 identified model errors in the incoming SW radiation in clear skies, the ground heat flux, the formulation of surface evaporation, the soil-moisture model, and the entrainment at boundary-layer top. The model clear-sky SW flux is too high at the surface by 5-10 percent. The ground heat flux is too large by a factor of 2 to 3 because of the large thermal capacity of the first soil layer (which is 7 cm thick), and a time truncation error. The surface evaporation was near zero in October 1987, rather than of order 70 W/sq m at noon. The surface evaporation falls too rapidly after rainfall, with a time-scale of a few days rather than the 7-10 d (or more) of the observations. On time-scales of more than a few days the specified 'climate layer' soil moisture, rather than the storage of precipitation, has a large control on the evapotranspiration. The boundary-layer-top entrainment is too low. This results in a moist bias in the boundary-layer mixing ratio of order 2 g/Kg in forecasts from an experimental analysis with nearly realistic surface fluxes; this because there is insufficient downward mixing of dry air.

Betts, Alan K.↗

Circulation and rainfall climatology of a 10-year (1979 - 1988) integration with the Goddard Laboratory for atmospheres general circulation model

A 10-year (1979-1988) integration of Goddard Laboratory for Atmospheres (GLA) general circulation model (GCM) under Atmospheric Model Intercomparison Project (AMIP) is analyzed and compared with observation. The first momentum fields of circulation variables and also hydrological variables including precipitation, evaporation, and soil moisture are presented. Our goals are (1) to produce a benchmark documentation of the GLA GCM for future model improvements; (2) to examine systematic errors between the simulated and the observed circulation, precipitation, and hydrologic cycle; (3) to examine the interannual variability of the simulated atmosphere and compare it with observation; and (4) to examine the ability of the model to capture the major climate anomalies in response to events such as El Nino and La Nina. The 10-year mean seasonal and annual simulated circulation is quite reasonable compared to the analyzed circulation, except the polar regions and area of high orography. Precipitation over tropics are quite well simulated, and the signal of El Nino/La Nina episodes can be easily identified. The time series of evaporation and soil moisture in the 12 biomes of the biosphere also show reasonable patterns compared to the estimated evaporation and soil moisture.

Kim, J.-H.↗

Heat Pipe Vapor Dynamics

The dynamic behavior of the vapor flow in heat pipes is investigated at startup and during operational transients. The vapor is modeled as two-dimensional, compressible viscous flow in an enclosure with inflow and outflow boundary conditions. For steady-state and operating transients, the SIMPLER method is used. In this method a control volume approach is employed on a staggered grid which makes the scheme very stable. It is shown that for relatively low input heat fluxes the compressibility of the vapor flow is low and the SIMPLER scheme is suitable for the study of transient vapor dynamics. When the input heat flux is high or the process under a startup operation starts at very low pressures and temperatures, the vapor is highly compressible and a shock wave is created in the evaporator. It is shown that for a wide range of input heat fluxes, the standard methods, including the SIMPLER scheme, are not suitable. A nonlinear filtering technique, along with the centered difference scheme, are then used for shock capturing as well as for the solution of the cell Reynolds-number problem. For high heat flux, the startup transient phase involves multiple shock reflections in the evaporator region. Each shock reflection causes a significant increase in the local pressure and a large pressure drop along the heat pipe. Furthermore, shock reflections cause flow reversal in the evaporation region and flow circulations in the adiabatic region. The maximum and maximum-averaged pressure drops in different sections of the heat pipe oscillate periodically with time because of multiple shock reflections. The pressure drop converges to a constant value at steady state. However, it is significantly higher than its steady-state value at the initiation of the startup transient. The time for the vapor core to reach steady-state condition depends on the input heat flux, the heat pipe geometry, the working fluid, and the condenser conditions. However, the vapor transient time, for an Na-filled heat pipe is on the order of seconds. Depending on the time constant for the overall system, the vapor transient time may be very short. Therefore, the vapor core may be assumed to be quasi-steady in the transient analysis of a heat pipe operation.

Issacci, Farrokh↗

Evolution of vaporizing pulsars

We construct evolutional scenarios for LMXB's using a simplified stellar model. We discuss the origin and evolution of short-period, low mass binary pulsars with evaporating companions. We suggest that these systems descend from low-mass X-ray binaries and that angular momentum loss mainly due to evaporative wind drives their evolution. We derive limits on the energy and angular momentum carried away by the wind based on the observed low eccentricity. In our model the companion remains near contact, and its quasiadiabatic expansion causes the binary to expand. Short-term oscillations of the orbital period may occur if the Roche-lobe overflow forms an evaporating disk.

Mccormick, P.↗

Modeling of Non-Spherical Droplet Dynamics

A two-dimensional time-dependent computer code based on the modified Arbitrary Lagrangian Eulerian (ALE) technique, has been developed to simulate non-spherical droplet dynamics and evaporation under convective flows at real rocket combustion chamber conditions. The equations of mass, momentum, energy and species are simultaneously solved for both liquid and gas phases with an accurate dynamic interface tracking. The jump boundary conditions across the deforming droplet surface are obtained by applying the integral forms of conservation of mass, momentum, and energy. At each time step, the interface geometry and flow properties at the droplet surface are implicitly solved by satisfying the interface boundary conditions. A Lagrangian technique was developed to track the arbitrarily moving interface between the liquid droplet and the external gas. An elliptic grid generator is adopted to dynamically reconstruct grids both inside and outside the droplet surface. This code has been used to study droplet oscillation, droplet deformation/breakup, nonspherical droplet evaporation in both low and high pressure convective flows. This presentation briefly describes the numerical algorithm for modeling of the nonspherical droplet dynamics and demonstrates the representative simulation results of nonspherical droplet evaporation at low and high pressure convective flows. Potential applications of this code to rocket combustor design and performance predictions are discussed.

Deng, Zheng-Tao↗

The tropical water and energy cycles in a cumulus ensemble model. Part 1: Equilibrium climate

A cumulus ensemble model is used to study the tropical water and energy cycles and their role in the climate system. The model includes cloud dynamics, radiative processes, and microphysics that incorporate all important production and conversion processes among water vapor and five species of hydrometeors. Radiative transfer in clouds is parameterized based on cloud contents and size distributions of each bulk hydrometeor. Several model integrations have been carried out under a variety of imposed boundary and large-scale conditions. In Part 1 of this paper, the primary focus is on the water and heat budgets of the control experiment, which is designed to simulate the convective - radiative equilibrium response of the model to an imposed vertical velocity and a fixed sea surface temperature at 28 C. The simulated atmosphere is conditionally unstable below the freezing level and close to neutral above the freezing level. The equilibrium water budget shows that the total moisture source, M(sub s), which is contributed by surface evaporation (0.24 M(sub s)) and the large-scale advection (0.76 M(sub s)), all converts to mean surface precipitation bar-P(sub s). Most of M(sub s) is transported verticaly in convective regions where much of the condensate is generated and falls to surface (0.68 bar-P(sub s)). The remaining condensate detrains at a rate of 0.48 bar-P(sub s) and constitutes 65% of the source for stratiform clouds above the melting level. The upper-level stratiform cloud dissipates into clear environment at a rate of 0.14 bar-P(sub s), which is a significant moisture source comparable to the detrained water vapor (0.15 bar-P(sub s)) to the upper troposphere from convective clouds. In the lower troposphere, stratiform clouds evaporate at a rate of 0.41 bar-P(sub s), which is a more dominant moisture source than surface evaporation (0.22 bar-P(sub s)). The precipitation falling to the surface in the stratiform region is about 0.32 bar-P(sub s). The associated latent heating in the water cycle is the dominant source in the heat budget that generates a net upward motion in convective regions, upper stratiform regions (above the freezing level), and a downward motion in the lower stratiform regions. The budgets reveal a cycle of water and energy resulted from radiation-dynamic-convection interactions that maintain equilibrium of the atmosphere.

Sui, C. H.↗

Solar flare model atmospheres

Solar flare model atmospheres computed under the assumption of energetic equilibrium in the chromosphere are presented. The models use a static, one-dimensional plane-parallel geometry and are designed within a physically self-consistent coronal loop. Assumed flare heating mechanisms include collisions from a flux of nonthermal electrons and X-ray heating of the chromosphere by the corona. The heating by energetic electrons accounts explicitly for variations of the ionized fraction with depth in the atmosphere. X-ray heating of the chromosphere by the corona incorporates a flare loop geometry by approximating distant portions of the loop with a series of point sources, while treating the loop leg closest to the chromospheric footpoint in the plane-parallel approximation. Coronal flare heating leads to increased heat conduction, chromospheric evaporation and subsequent changes in coronal pressure; these effects are included self-consistently in the models. Cooling in the chromosphere is computed in detail for the important optically thick H I, Ca II and Mg II transitions using the non-local thermodynamic equilibrium (non-LTE) prescription in the program MULTI. Hydrogen ionization rates from X-ray photoionization and collisional ionization by nonthermal electrons are included explicitly in the rate equations. The models are computed in the 'impulsive' and 'equilibrium' limits, and in a set of intermediate 'evolving' states. The impulsive atmospheres have the density distribution frozen in the pre-flare configuration, while the equilibrium models assume the entire atmosphere is in hydrostatic and energetic equilibrium. The evolving atmospheres represent intermediate stages where hydrostatic equilibrium has been established in the chromosphere and corona, but the corona is not yet in energetic equilibrium with the flare heating source. Thus, for example, chromospheric evaporation is still in the process of occurring. We have computed the chromospheric radiation that results from a range of coronal heating rates, with particular emphasis on the widely observed diagnostic H(alpha). Our conclusion is that the H(alpha) fluxes and profiles actually observed in flares can only be produced under conditions of a low-pressure corona with strong beam heating. Therefore we suggest that H(alpha) in flares is produced primarily at the footprints of newly heated loops where significant evaporation has not yet occurred. As a single loop evolves in time, no matter how strong the heating rate may become, the H(alpha) flux will diminish as the corona becomes denser and hence more effective at stopping the beam. This prediction leads to several observable consequences regarding the spatial and temporal signatures of the X-ray and H(alpha) radiation during flares.

Hawley, Suzanne L.↗