Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies and costs for achieving a ZC building or microgrid.

03 NATURAL GAS↗

Model Predictive Control for the Operation of Building Cooling Systems

A model-based predictive control (MPC) is designed for optimal thermal energy storage in building cooling systems. We focus on buildings equipped with a water tank used for actively storing cold water produced by a series of chillers. Typically the chillers are operated at night to recharge the storage tank in order to meet the building demands on the following day. In this paper, we build on our previous work, improve the building load model, and present experimental results. The experiments show that MPC can achieve reduction in the central plant electricity cost and improvement of its efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of image acquisition techniques for dual-energy imaging of the chest

Experimental and theoretical studies were conducted to determine optimal acquisition techniques for a prototype dual-energy (DE) chest imaging system. Technique factors investigated included the selection of added x-ray filtration, kVp pair, and the allocation of dose between low- and high-energy projections, with total dose equal to or less than that of a conventional chest radiograph. Optima were computed to maximize lung nodule detectability as characterized by the signal-difference-to-noise ratio (SDNR) in DE chest images. Optimal beam filtration was determined by cascaded systems analysis of DE image SDNR for filter selections across the periodic table (Z{sub filter}=1-92), demonstrating the importance of differential filtration between low- and high-kVp projections and suggesting optimal high-kVp filters in the range Z{sub filter}=25-50. For example, added filtration of {approx}2.1 mm Cu, {approx}1.2 mm Zr, {approx}0.7 mm Mo, and {approx}0.6 mm Ag to the high-kVp beam provided optimal (and nearly equivalent) soft-tissue SDNR. Optimal kVp pair and dose allocation were investigated using a chest phantom presenting simulated lung nodules and ribs for thin, average, and thick body habitus. Low- and high-energy techniques ranged from 60-90 kVp and 120-150 kVp, respectively, with peak soft-tissue SDNR achieved at [60/120] kVp for all patient thicknesses and all levels of imaging dose. A strong dependence on the kVp of the low-energy projection was observed. Optimal allocation of dose between low- and high-energy projections was such that {approx}30% of the total dose was delivered by the low-kVp projection, exhibiting a fairly weak dependence on kVp pair and dose. The results have guided the implementation of a prototype DE imaging system for imaging trials in early-stage lung nodule detection and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scalable Energy System Expansion Under Uncertainty Using Multi-Stage Stochastic Optimization

The intermittent nature of renewable energy sources poses challenges for electrical grids. This is due to the variable and uncertain nature of the power output from these resources. These features of renewable generation are more relevant to energy system planning as grids reach higher penetration levels of renewable energy. We present approaches for energy system planning based on scalable computational approaches which enable explicit consideration of operational uncertainties in the planning process. Using multi-stage stochastic programming and the progressive hedging algorithm, we compute energy system expansion decisions on modified versions of the RTS-GMLC test system.

electrical↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal design and integration of decentralized electrochemical energy storage with renewables and fossil plants

Increasing renewable energy requires improving the electricity grid flexibility. Existing measures include power plant cycling and grid-level energy storage, but they incur high operational and investment costs. Using a systems modeling and optimization framework, we study the integration of electrochemical energy storage with individual power plants at various renewable penetration levels. Furthermore, our techno-economic analysis includes both Li-ion and NaS batteries to encompass different technology maturity levels. A California case-study indicates localized integration to be cost-effective for greater grid flexibility. Li-ion batteries can mitigate the residual demand fluctuations of small to medium-sized plants, while NaS batteries would be best-suited for larger storage with higher renewable penetration. Overall, the battery-enabled renewable integration could reduce the unmet grid demand by 75%, the renewable curtailment by 58%, and the CO 2 emission intensity by 16% while including the life cycle emissions of the battery and the renewable farm. Our scenario-based analysis also indicates that rather than replacing all fossil power plants, it is more economical to combine batteries and renewables with individual fossil plants to achieve a clean energy grid.

25 ENERGY STORAGE↗

Digital Twin for Optimizing Real-time Economy of the Integrated Energy Systems

Economic and safe operation of integrated energy systems (IES) requires real-time optimization (RTO) of the control and actions conducted on each system component. In this regard, digital twins (DTs), which consist of a physical system, a virtual system, and the data communication that occurs between the two, are essential for effective RTO. Through the data warehouse, the virtual system is constantly updated with real-time data from the physical system, and functions as the model in the optimization framework. The reduced-order model of the dynamic process model in the virtual system is used in the optimization framework. The optimization results are then returned, via the data warehouse, as control actions to the physical system. This work demonstrates the software capabilities of DT assets for an IES in the context of preparing a DT for an experimental system comprised of Idaho National Laboratory (INL)’s Thermal Energy Delivery System and battery system. For the virtual demonstration, the DTs encompass (1) a physical system, including the Modelica models of the Thermal Energy Delivery System and the battery system; (2) virtual optimization via the Optimization of Real-Time Capacity Allocation (ORCA) platform; and (3) the open-source data warehouse software DeepLynx. This work assesses the performance of ORCA, which utilizes a reduced-order model built using the Risk Analysis Virtual Environment (RAVEN) and trained on the Modelica models and real-time data pipeline through the graph database hosted in DeepLynx. The proposed optimization workflow will be an RTO model based on DTs and the data they generate.

25 ENERGY STORAGE↗

A Reinforcement Learning Approach to Parameter Selection for Distributed Optimal Power Flow

With the increasing penetration of distributed energy resources, distributed optimization algorithms have attracted significant attention for power systems applications due to their potential for superior scalability, privacy, and robustness to a single point-of-failure. The Alternating Direction Method of Multipliers (ADMM) is a popular distributed optimization algorithm; however, its convergence performance is highly dependent on the selection of penalty parameters, which are usually chosen heuristically. In this work, we use reinforcement learning (RL) to develop an adaptive penalty parameter selection policy for alternating current optimal power flow (ACOPF) problem solved via ADMM with the goal of minimizing the number of iterations until convergence. We train our RL policy using deep Q-learning and show that this policy can result in significantly accelerated convergence (up to a 59% reduction in the number of iterations compared to existing, curvatureinformed penalty parameter selection methods). Furthermore, we show that our RL policy demonstrates promise for generalizability, performing well under unseen loading schemes as well as under unseen losses of lines and generators (up to a 50% reduction in iterations). This work thus provides a proof-of-concept for using RL for parameter selection in ADMM for power systems applications.

alternating current optimal power flow↗

Nonlinear multiobjective and dynamic real-time predictive optimization for optimal operation of baseload power plants under variable renewable energy

Considering the increase of disruptive variable renewable energy penetration into the power grid, this article focuses on the investigation of a multiobjective and dynamic real-time optimization framework to address the cycling of large-scale power plants under renewable penetration. In this framework, a parallelized particle swarm optimization step is first performed to generate feasible initial points. Then, a multiobjective and dynamic real-time optimization formulation generates optimal trajectories. Further, the benefit of predictive capability is investigated for the dynamic component, which introduces the novel nonlinear multiobjective and dynamic real-time predictive optimization approach. Two multiobjective formulations to obtain Pareto front optimal in real time are explored: the modified Tchebycheff-based weighted metric and ϵ-constraint methods. Economic and environmental objectives are considered in this study. A novel topical discussion on the intersection of dynamic real-time optimization with model predictive control is also presented. The developed framework is successfully applied to a baseload coal-fired power plant with postcombustion CO 2 capture. Results indicate that the approach can be deployed for a large-scale system if automatic differentiation, model reduction, and parallelization are adopted to improve computational tractability, with computational improvement up to 120-folds after performing these steps. Finally, market and carbon policies showed an impact on the optimal compromise between the objectives with an additional 63 ton of CO 2 captured under favorable market conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An efficient optimization of well placement and control for a geothermal prospect under geological uncertainty

This work applies an efficient optimization technique based on a multivariate adaptive regression spline (MARS) technique to determine the optimal design and engineering of a potential geothermal production operation at a prospect near Superstition Mountain in Southern California, USA. The faster MARS-based statistical model is used as a surrogate for higher-fidelity physical models within the intensive optimization process. Its use allows for the exploration of the impacts of specific engineering design parameters in the context of geologic uncertainty as a means to both understand and maximize profitability of the production operation. The MARS model is initially developed from a training dataset generated by a finite set of computationally complex hydrothermal models applied to the prospect. Its application reveals that the optimal engineering design variables can differ considerably assuming different choices of hydrothermal flow properties, which, in turn, indicates the importance of reducing the uncertainty of key geologic properties. The major uncertainty sources in the natural-system are identified and ranked first by an efficient MARS-enabled total order sensitivity quantification, which is then used to assist evaluating the effect of geological uncertainties on optimized results. At the Southern California prospect, this parameter sensitivity analysis suggests that groundwater circulation through high permeable structures, rather than heat conduction through impermeable granite, is the primary heat transfer method during geothermal extraction. Reservoir histories simulated using optimal parameters with different constraints are analyzed and compared to investigate the longevity and maximum profit of the geothermal resources. The comparison shows that the longevity and profit are very likely to be overestimated by optimizations without appropriate constraints on natural conditions. In addition to geothermal energy production, this optimization approach can also be used to manage other geologic resource operations, such as hydrocarbon production or CO 2 sequestration, under uncertain reservoir conditions.

15 GEOTHERMAL ENERGY↗

Synthetic Electricity Market Data Generation and HERON Use Case Setup of Advanced Nuclear Reactors Coupled with Thermal Energy Storage Systems

This study evaluates and optimizes advanced nuclear reactors coupled with thermal energy storage (TES) systems in an Integrated Energy System (IES) architecture to enable advanced nuclear power plants (A NPP) to participate in multi-commodity markets, thus enhancing their economic competitiveness. Nuclear-TES coupling scenarios studied herein are designed attenuate the nuclear heat dynamics and defer energy delivery to a later time, enabling the nuclear reactor to continue operating at or near steady-state design conditions as usual while also enabling flexible generation. Three A-NPPs, namely, an advanced light-water reactor (A LWR), a high temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating the technoeconomic of thermally balanced energy storage coupling design for thermal power extraction. Each of the reactor technologies were evaluated in two different electricity markets. Stochastic optimization approach was adopted which included the evaluation of price signals from the Pennsylvania-New Jersey-Maryland (PJM) market, and Electric Reliability Council of Texas (ERCOT), using an autoregressive moving average (ARMA) model. Risk Analysis Virtual Environment (RAVEN) tool and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON), were used to perform dispatch and capacity optimization, using the price data provided by the ARMA models. The results from the Nuclear-TES use cases will be used to design and characterize dynamic integrated system behavior and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Maximizing the Benefits of Volt/VAR Optimization in the Presence of Community Energy Storage

This paper reports on the need for coordinating smart grid volt/volt-ampere reactive (VAR) control (VVC) and community energy storage (CES) to maximize the benefits of both approaches. It addresses a key application of volt/VAR optimization (VVO): the conservation of voltage reduction (CVR). The lack of coordination among network controls, such as VVO, and asset controls at the community battery storage system can lead to detrimental effects on grid operation. A smart grid-enabled VVC uses the VVO to perform the CVR operation. VVO can perform numerous tasks for advanced distribution management systems with coordination of the system operator. To achieve the optimal VVC solution, we use a particle swarm optimization driven VVO method. The test system has been simulated for two scenarios-during light loading and high loading condition-with and without the CES system. In both scenarios, the operation of CVR and CES have been performed considering different case studies. The outcomes of the simulated results demonstrate that significant improvement in peak load-demand reduction is achieved by the proposed VVC and CES system with reduced system losses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic analysis of renewable energy generation at the South Pole

Transitioning from fossil-fuel power generation to renewable energy generation and energy storage in remote locations has the potential to reduce both carbon emissions and cost. Here, this study presents a techno-economic analysis for implementation of a hybrid renewable energy system at the South Pole in Antarctica, which currently hosts several high-energy physics experiments with nontrivial power needs. A tailored model of resource availability and economics for solar photovoltaics, wind turbine generators, lithium-ion energy storage, and long-duration energy storage at this site is explored in different combinations with and without existing diesel energy generation. The Renewable Energy Integration and Optimization (REopt) platform is used to determine the optimal system component sizing and the associated system economics and environmental benefit. We find that the least-cost system includes all three energy generation sources and lithium-ion energy storage. For an example steady-state load of 170 kW, this hybrid system includes 180 kW-DC of photovoltaic panels, 570 kW of wind turbines, and a 3.4 MWh lithium-ion battery energy storage system. This system reduces diesel consumption by 95% compared to an all -diesel configuration, resulting in approximately 1200 metric tons of carbon footprint avoided annually. Over the course of a 15-year analysis period the reduced diesel usage leads to a net savings of 57 million United States dollars, with a time to payback of approximately two years. All the scenarios modeled show that the transition to renewables is highly cost effective under the unique economics and constraints of this extremely remote site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Capacity optimization of nuclear power integration to meet dynamic industrial demand

To decarbonize their industrial facilities, The Dow Chemical Company has collaborated with Idaho National Laboratory (INL) to study the integration of nuclear power with an industrial chemical facility. Using Holistic Energy and Resource Optimization Network developed at INL for optimizing and analyzing integrated energy systems, a nuclear microreactor system was sized and evaluated for dynamic dispatch to Dow Silicones Corporation’s Carrollton, KY (USA) site for iloxane production. It was found that a 180 MW th system (12 × 15MW th ) with 75.1 MWh th of thermal energy storage could provide heat and power to the chemical facilities. In the process, this would reduce electricity imports by 99.9 % and reduce the Scope 1 and 2 emissions of the site by 292,100 tonnes CO 2 /yr (98.8 %). The primary novelty of this work is a first of a kind design and optimization of a microreactor powered integrated energy system to provide heat and power to a chemical plant using real plant data. This analysis will pave the way for future studies using dispatchable clean energy sources to reduce carbon emissions and commodity industries’ reliance on fossil fuels.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal operation and sizing of pumped thermal energy storage for net benefits maximization

Abstract Current trends in the modern grid are leading to the development and deployment of energy storage to help integrate increasing variable renewable energy sources into the grid. This paper studies a pumped thermal energy storage (PTES) system for multiple grid services including energy arbitrage, frequency regulation, spinning and non‐spinning reserve, and resource adequacy. Optimal dispatch methods are proposed for individual services as well as value stacking from multiple services to maximize the economic benefits. Assessment results demonstrate the superiority of value stacking. Specifically, the study shows the maximum revenue from an individual grid service with a 30‐MWh PTES system was $522,520, while the value stacking could increase the benefits to $678,477. In addition, sensitivity analyses were conducted to explore the cost‐effectiveness of a PTES system with different combinations of power transfer limits and energy capacity. It was found that the power transfer limit had a greater impact than the energy capacity on the benefits. The proposed method could help determine the optimal duration of a future PTES system.

25 ENERGY STORAGE↗

Computational analysis of deployable wind turbine systems in defense operational energy applications.

The U.S. military has been exploring pathways to reduce the logistical burden of fuel on virtually all their missions globally. Energy harvesting of local resources such as wind and solar can help increase the resilience and operational effectiveness of military units, especially at the most forward operating bases where the fuel logistics are most challenging. This report considers the potential benefits of wind energy provided by deployable wind turbines as measured by a reduction in fuel consumption and supply convoys to a hypothetical network of Army Infantry Brigade Combat Team bases. Two modeling and simulation tools are used to represent the bases and their operations and quantify the impacts of system design variables that include wind turbine technologies, battery storage, number of turbines, and wind resource quality. The System of Systems Analysis Toolkit Joint Operational Energy Model serves as a baseline scenario for comparison. The Hybrid Optimization of Multiple Energy Resources simulation tool is used to optimize a single base within the larger Joint Operational Energy Model. The results of both tools show that wind turbines can provide significant benefits to contingency bases in terms of reduced fuel use and number of convoy trips to resupply the base. The match between the turbine design and wind resource, which is statistically low across most of the global land area, is a critical design consideration. The addition of battery storage can enhance the benefits of wind turbines, especially in systems with more wind turbines and higher wind resources. Wind turbines may also provide additional benefits to other metrics such as resilience that may be important but not fully considered in the current analysis. ACKNOWLEDGEMENTS The authors would like to thank the following individuals for their helpful support, feedback and review to improve this report: U.S. Department of Energy Wind Energy Technologies Office, Patrick Gilman and Bret Barker; Idaho National Laboratory, Jake Gentle and Bradley Whipple; The National Renewable Energy Laboratory, Robert Preus and Tony Jimenez; Sandia National Laboratories, Alan Nanco, Dennis Anderson, and Hai Le. In addition, numerous discussions with military and industry stakeholders over the year were invaluable in focusing the efforts represented in this report.

17 WIND ENERGY↗

Comparison of Real-Time Pressure Rail Selection Algorithms for the Hybrid Hydraulic Electric Architecture: Case Study on a Track Loader

Abstract The hybrid hydraulic electric architecture (HHEA) seeks to combine the high power/torque/force density of hydraulics with the efficiency of electric machines. A set of common pressure rails is used to provide a majority of the power and this power is modulated by small electric machines to provide precise control for the operator. The HHEA has been studied in previous work using off-line dynamic programming optimization to determine energy efficient pressure rail selections, but this approach requires drive cycle information apriori. A Lagrange multiplier method has also been investigated where a set of gains (Lagrange multipliers) are optimized off-line with the idea the these gains, once determined, could be used for real-time operation. In this work, three new real-time pressure rail selection algorithms that do not require future drive cycle information are investigated; greedy, torque minimizing, and thresholding. The greedy control is found to only use 1% more energy than the globally optimal dynamic programming solution; but a model of energy loss is required.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis and Optimization of a Compressed-Air Energy Storage System Integrated with a Natural Gas Combined-Cycle Plant

To address the rising electricity demand and greenhouse gas concentration in the environment, considerable effort is being carried out across the globe on installing and operating renewable energy sources. However, the renewable energy production is affected by diurnal and seasonal variability. To ensure that the electric grid remains reliable and resilient even for the high penetration of renewables into the grid, various types of energy storage systems are being investigated. In this paper, a compressed-air energy storage (CAES) system integrated with a natural gas combined-cycle (NGCC) power plant is investigated where air is extracted from the gas turbine compressor or injected back into the gas turbine combustor when it is optimal to do so. First-principles dynamic models of the NGCC plant and CAES are developed along with the development of an economic model. The dynamic optimization of the integrated system is undertaken in the Python/Pyomo platform for maximizing the net present value (NPV). NPV optimization is undertaken for 14 regions/cases considering year-long locational marginal price (LMP) data with a 1 h interval. Design variables such as the storage capacity and storage pressure, as well as the operating variables such as the power plant load, air injection rate, and air extraction rate, are optimized. Results show that the integrated CAES system has a higher NPV than the NGCC-only system for all 14 regions, thus indicating the potential deployment of the integrated system under the assumption of the availability of caverns in close proximity to the NGCC plant. The levelized cost of storage is found to be in the range of 136–145 $/MWh. Roundtrip efficiency is found to be between 74.6–82.5%. A sensitivity study with respect to LMP shows that the LMP profile has a significant impact on the extent of air injection/extraction while capital expenditure reduction has a negligible effect.

25 ENERGY STORAGE↗