Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Quantitative imaging and automated fuel pin identification for passive gamma emission tomography

Compliance of member States to the Treaty on the Non-Proliferation of Nuclear Weapons is monitored through nuclear safeguards. The Passive Gamma Emission Tomography (PGET) system is a novel instrument developed within the framework of the International Atomic Energy Agency (IAEA) project JNT 1510, which included the European Commission, Finland, Hungary and Sweden. The PGET is used for the verification of spent nuclear fuel stored in water pools. Advanced image reconstruction techniques are crucial for obtaining high-quality cross-sectional images of the spent-fuel bundle to allow inspectors of the IAEA to monitor nuclear material and promptly identify its diversion. In this work, we have developed a software suite to accurately reconstruct the spent-fuel cross sectional image, automatically identify present fuel rods, and estimate their activity. Unique image reconstruction challenges are posed by the measurement of spent fuel, due to its high activity and the self-attenuation. While the former is mitigated by detector physical collimation, we implemented a linear forward model to model the detector responses to the fuel rods inside the PGET, to account for the latter. The image reconstruction is performed by solving a regularized linear inverse problem using the fast-iterative shrinkage-thresholding algorithm. We have also implemented the traditional filtered back projection (FBP) method based on the inverse Radon transform for comparison and applied both methods to reconstruct images of simulated mockup fuel assemblies. Higher image resolution and fewer reconstruction artifacts were obtained with the inverse-problem approach, with the mean-square-error reduced by 50%, and the structural-similarity improved by 200%. We then used a convolutional neural network (CNN) to automatically identify the bundle type and extract the pin locations from the images; the estimated activity levels finally being compared with the ground truth. The proposed computational methods accurately estimated the activity levels of the present pins, with an associated uncertainty of approximately 5%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Approaches to Object Classification in Synoptic Sky Surveys

Digital synoptic sky surveys pose several new object classification challenges. In surveys where real-time detection and classification of transient events is a science driver, there is a need for an effective elimination of instrument-related artifacts which can masquerade as transient sources in the detection pipeline, e.g., unremoved large cosmic rays, saturation trails, reflections, crosstalk artifacts, etc. We have implemented such an Artifact Filter, using a supervised neural network, for the real-time processing pipeline in the Palomar-Quest (PQ) survey. After the training phase, for each object it takes as input a set of measured morphological parameters and returns the probability of it being a real object. Despite the relatively low number of training cases for many kinds of artifacts, the overall artifact classification rate is around 90%, with no genuine transients misclassified during our real-time scans. Another question is how to assign an optimal star-galaxy classification in a multi-pass survey, where seeing and other conditions change between different epochs, potentially producing inconsistent classifications for the same object. We have implemented a star/galaxy multipass classifier that makes use of external and a priori knowledge to find the optimal classification from the individually derived ones. Both these techniques can be applied to other, similar surveys and data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

How Well Can We Estimate Areal-Averaged Spectral Surface Albedo from Ground-Based Transmission in an Atlantic Coastal Area?

Areal-averaged albedos are particularly difficult to measure in coastal regions, because the surface is not homogenous, consisting of a sharp demarcation between land and water. With this difficulty in mind, we evaluate a simple retrieval of areal-averaged surface albedo using ground-based measurements of atmospheric transmission alone under fully overcast conditions. To illustrate the performance of our retrieval, we find the areal-averaged albedo using measurements from the Multi-Filter Rotating Shadowband Radiometer (MFRSR) at five wavelengths (415, 500, 615, 673, and 870 nm). These MFRSR data are collected at a coastal site in Graciosa Island, Azores supported by the U.S. Department of Energy’s (DOE’s) Atmospheric Radiation Measurement (ARM) Program. The areal-averaged albedos obtained from the MFRSR are compared with collocated and coincident Moderate Resolution Imaging Spectroradiometer (MODIS) white-sky albedo at four nominal wavelengths (470, 560, 670 and 860 nm). These comparisons are made during a 19-month period (June 2009 - December 2010). We also calculate composite-based spectral values of surface albedo by a weighted-average approach using estimated fractions of major surface types observed in an area surrounding this coastal site. Taken as a whole, these three methods of finding albedo show spectral and temporal similarities, and suggest that our simple, transmission-based technique holds promise, but with estimated errors of about ±0.03. Additional work is needed to reduce this uncertainty in areas with inhomogeneous surfaces.

Kassianov, Evgueni I.↗

Chromatic effects on the PSF and shear measurement for the Roman Space Telescope High-Latitude Wide Area Survey

Weak gravitational lensing (WL) is a key cosmological probe that requires precise measurement of galaxy images to infer shape distortions, or shear, and constrain cosmology. Accurate estimation of the point spread function (PSF) is crucial for shear measurement, but the wavelength dependence of the PSF introduces chromatic biases that can systematically impact shear inference. We focus on biases arising from spectral energy distribution (SED) differences between stars, used for PSF modelling, and galaxies, used for shear measurement. We investigate these effects in Roman’s four design reference mission WL bands (Y106, J129, H158, F184) and wide filter (W146). Using Roman-like image simulations, we quantify the induced shear biases and compare them to requirements on those biases. Multiplicative biases over all galaxies hover around ~0.2 per cent in the WL bands and 2 per cent in the wide filter, exceeding the mission requirement of |m| < 0.032 per cent and relaxed requirement of |m| < 0.1 per cent⁠. In individual redshift bins, biases can reach 0.4–0.9 per cent for the WL bands and 3–6 per cent for the wide filter. Additive biases remain acceptable in the WL bands but exceed systematic limits in the wide filter. We develop and test PSF-level corrections, showing that a first-order correction reduces biases within survey requirements for the WL bands; however, higher-order terms are necessary for the wide filter. Our results highlight the necessity of chromatic corrections for precision WL with Roman and provide a framework for mitigating these biases. Finally, we compare analytical colour-based corrections to self-organizing maps and find that both methods effectively reduce biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Comprehensive Gas-Phase Peptide Ion Structure Studies Using Ion Mobility Techniques: Part 2. Gas-Phase Hydrogen/Deuterium Exchange for Ion Population Estimation

Gas-phase hydrogen/deuterium exchange (HDX) using D{sub 2}O reagent and collision cross-section (CCS) measurements are utilized to monitor the ion conformers of the model peptide acetyl-PAAAAKAAAAKAAAAKAAAAK. The measurements are carried out on a home-built ion mobility instrument coupled to a linear ion trap mass spectrometer containing electron transfer dissociation (ETD) capabilities. ETD is utilized to obtain per-residue deuterium uptake data for select ion conformers, and a new algorithm is presented for interpreting the HDX data. Using molecular dynamics (MD) production data and a hydrogen accessibility scoring (HAS)-number of effective collisions (NEC) model, hypothetical HDX behavior is attributed to various in-silico candidate (CCS match) structures. The HAS-NEC model is applied to all candidate structures, and non-negative linear regression is employed to determine structure contributions resulting in the best match to deuterium uptake. The accuracy of the HAS-NEC model is tested with the comparison of predicted and experimental isotopic envelopes for several of the observed c-ions. It is proposed that gas-phase HDX can be utilized effectively as a second criterion (after CCS matching) for filtering suitable MD candidate structures. In this study, the second step of structure elucidation, 13 nominal structures were selected (from a pool of 300 candidate structures) and each with a population contribution proposed for these ions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flattening Filter Free vs Flattened Beams for Breast Irradiation

Purpose: Flattening filter free (FFF) beams offer the potential for a higher dose rate, shorter treatment time, and lower peripheral dose. To investigate their role in large-field treatments, this study compared flattened and FFF beams for breast irradiation. Methods and Materials: Ten left breast clinical plans comprising 2 tangential beams and a medially located 3-field simultaneous integrated boost (SIB) were replanned. Full intensity modulated radiotherapy (IMRT), hybrid IMRT, electronic tissue compensator (ETC), and multiple static field treatment plans were created for the elective breast volume using flattened and FFF beams, in combination with a 3-field IMRT SIB. Plan quality was assessed and delivery times were measured for all plans for 1 patient. Out-of-field doses were measured using an ionization chamber for an IMRT plan optimized on a corner of simple cubic phantom for both flattened and FFF beams. Results: For each technique, mean target volume metrics (planning target volume coverage, homogeneity, conformity) were typically within 3% for flattened and FFF beams. Larger mean differences in boost conformity favoring flattened hybrid (7.2%) and full IMRT (5.5%) plans may have reflected limitations in plan normalization. Calculated heart and ipsilateral lung doses were comparable; however, both flattened and FFF low-dose phantom measurements were substantially higher than calculated values, rendering the comparison of low dose in the contralateral breast uncertain. Beam delivery times were on average 31% less for FFF. Conclusions: In general, target volume metrics for flattened and FFF plans were comparable. The planning system did not seem to allow for accurate peripheral dose evaluation. FFF was associated with a potentially shorter treatment time. All 4 IMRT techniques allowed FFF beams to generate acceptable plans for breast IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Centrality determination with a forward detector in the RHIC Beam Energy Scan

Recently, Chatterjee et al [1] used a hadronic transport model to estimate the resolution with which various experimental quantities select the impact parameter of relativistic heavy ion collisions at collision energies relevant to the Beam Energy Scan (BES) program at the Relativistic Heavy Ion Collider (RHIC). Measures based on particle multiplicity at forward rapidity were found to be significantly worse than those based on midrapidity multiplicity. Using the same model, we show that a slightly more sophisticated measure greatly improves the resolution based on forward rapidity particles; this improvement persists even when the model is filtered through a realistic simulation of a recent upgrade detector to the STAR experiment. Furthermore, these results highlight the importance of optimizing centrality measures based on particles detected at forward rapidity, especially for experimental studies that search for a critical point in the QCD phase diagram. Such measurements usually focus on proton multiplicity fluctuations at midrapidity, hence selecting events based on multiplicity at midrapidity raises the possibility of nontrivial autocorrelations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Hybrid-Learning Algorithm for Online Dynamic State Estimation in Multimachine Power Systems

With the increasing penetration of distributed generators in the smart grids, having knowledge of rapid real-time electromechanical dynamic states has become crucial to system stability control. Conventional Supervisory Control and Data Acquisition (SCADA)-based dynamic state estimation (DSE) techniques are limited by the slow sampling rates, while the emerging phasor measurement units (PMUs) technology enables rapid real-time measurements at network nodes. Using generator bus terminal voltages, we propose a hybrid-learning DSE (HL-DSE) algorithm to estimate the synchronous machine rotor angle and speed in real time. The HL-DSE takes the power system model into account and trains neuroestimators with real-time data in an online manner. Compared with traditional DSE methods, the HL-DSE overcomes limitations by using a data-driven approach in conjunction with the physical power system model. The time efficiency, accuracy, convergence, and robustness of the proposed algorithm are tested under noises and fault conditions in both small- and large-scale test systems. Simulation results show that the proposed HL-DSE is much more computationally efficient than widely used Kalman filter (KF)-based methods while maintaining comparable accuracy and robustness. In particular, HL-DSE is over 100 times faster than square-root unscented KF (SR-UKF) and 80 times faster than extended KF (EKF). The advantages and challenges of the HL-DSE are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identification of Silver and Palladium in Irradiated TRISO Coated Particles of the AGR-1 Experiment

Evidence of the release of certain metallic fission product through intact tristructural isotropic (TRISO) particles has been seen for decades around the world, as well as in the recent AGR-1 experiment at Idaho National Laboratory (INL). However, understanding the basic mechanism of transport is still lacking. This understanding is important because the TRISO coating is part of the high temperature gas reactor functional containment and critical for the safety strategy for licensing purposes. Our approach to identify fission products in irradiated AGR-1 TRISO fuel using scanning transmission electron microscopy (STEM), Electron Energy Loss Spectroscopy (EELS) and Energy Filtered TEM (EFTEM), has led to first-of-a-kind data at the nano-scale indicating the presence of silver at triple points and grain boundaries of the SiC layer in the TRISO particle. Cadmium was also found in the triple junctions. In this initial study, the silver was only identified in SiC grain boundaries and triple points on the edge of the SiC-IPyC interface up to a depth of approximately 0.5 um. Palladium was identified as the main constituent of micron-sized precipitates present at the SiC grain boundaries. Additionally spherical nano-sized palladium rich precipitates were found inside the SiC grains. These nano-sized Pd precipitates were distributed up to a depth of 5 um away from the SiC-IPyC interlayer. No silver was found in the center of the micron-sized fission product precipitates using these techniques, although silver was found on the outer edge of one of the Pd-U-Si containing precipitates which was facing the IPyC layer. Only Pd-U containing precipitates were identified in the IPyC layer and no silver was identified in the IPyC layer. The identification of silver alongside the grain boundaries and the findings of Pd alongside grain boundaries as well as inside the grains, provide significant knowledge for understanding silver and palladium transport in TIRSO fuel, which has been the topic of international research for the past forty years. Additionally the usefulness of the advanced electron microscopic techniques for TRISO coated particle research is demonstrated in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prostate Localization on Daily Cone-Beam Computed Tomography Images: Accuracy Assessment of Similarity Metrics

Purpose: To evaluate different similarity metrics (SM) using natural calcifications and observation-based measures to determine the most accurate prostate and seminal vesicle localization on daily cone-beam CT (CBCT) images. Methods and Materials: CBCT images of 29 patients were retrospectively analyzed; 14 patients with prostate calcifications (calcification data set) and 15 patients without calcifications (no-calcification data set). Three groups of test registrations were performed. Test 1: 70 CT/CBCT pairs from calcification dataset were registered using 17 SMs (6,580 registrations) and compared using the calcification mismatch error as an endpoint. Test 2: Using the four best SMs from Test 1, 75 CT/CBCT pairs in the no-calcification data set were registered (300 registrations). Accuracy of contour overlays was ranked visually. Test 3: For the best SM from Tests 1 and 2, accuracy was estimated using 356 CT/CBCT registrations. Additionally, target expansion margins were investigated for generating registration regions of interest. Results: Test 1-Incremental sign correlation (ISC), gradient correlation (GC), gradient difference (GD), and normalized cross correlation (NCC) showed the smallest errors ({mu} {+-} {sigma}: 1.6 {+-} 0.9 {approx} 2.9 {+-} 2.1 mm). Test 2-Two of the three reviewers ranked GC higher. Test 3-Using GC, 96% of registrations showed <3-mm error when calcifications were filtered. Errors were left/right: 0.1 {+-} 0.5mm, anterior/posterior: 0.8 {+-} 1.0mm, and superior/inferior: 0.5 {+-} 1.1 mm. The existence of calcifications increased the success rate to 97%. Expansion margins of 4-10 mm were equally successful. Conclusion: Gradient-based SMs were most accurate. Estimated error was found to be <3 mm (1.1 mm SD) in 96% of the registrations. Results suggest that the contour expansion margin should be no less than 4 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theory of spin-coherent electrical transport through a defect spin state in a metal/insulator/ferromagnet tunnel junction undergoing ferromagnetic resonance

In this work, we describe the coherent dynamics of electrical transport through a localized spin-dependent state, such as is associated with a defect spin, at the interface of a ferromagnet and a nonmagnetic material during ferromagnetic resonance. As the ferromagnet magnetic moment precesses, charge carriers are dynamically spin filtered by the localized state, leading to a dynamic spin accumulation on the defect. Local effective magnetic fields modify the precession of a spin on the defect, which also modifies the time-integrated total charge current through the defect. Lastly, we thus identify a form of current-detected spin resonance that reveals the local magnetic environment of a carrier spin located at a defect, and thus potentially the defect’s identity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Studies for CPF and SCR Model, Control System, and OBD Development for Engines Using Diesel and Biodiesel Fuels

The research carried out on this project developed experimentally validated Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), and Selective Catalytic Reduction (SCR) high-fidelity models that served as the basis for the reduced order models used for internal state estimation. The high-fidelity and reduced order/estimator codes were evaluated by the industrial partners with feedback to MTU that improved the codes. Ammonia, particulate matter (PM) mass retained, PM concentration, and NOX sensors were evaluated and used in conjunction with the estimator codes. The data collected from PM experiments were used to develop the PM kinetics using the high-fidelity DPF code for both NO2 assisted oxidation and thermal oxidation for Ultra Low Sulfur Fuel (ULSF), and B10 and B20 biodiesel fuels. Nine SAE papers were presented and this technology transfer process should provide the basis for industry to improve the OBD and control of urea injection and fuel injection for active regeneration of the PM in the DPF using the computational techniques developed. This knowledge will provide industry the ability to reduce the emissions and fuel consumption from vehicles in the field. Four MS and three PhD Mechanical Engineering students were supported on this project and their thesis research provided them with expertise in experimental, modeling, and controls in aftertreatment systems.

33 ADVANCED PROPULSION SYSTEMS↗

How to COAAD Images. II. A Coaddition Image that is Optimal for Any Purpose in the Background-dominated Noise Limit

Image coaddition is one of the most basic operations that astronomers perform. In Paper I, we presented the optimal ways to coadd images in order to detect faint sources and to perform flux measurements under the assumption that the noise is approximately Gaussian. Here, we build on these results and derive from first principles a coaddition technique that is optimal for any hypothesis testing and measurement (e.g., source detection, flux or shape measurements, and star/galaxy separation), in the background-noise-dominated case. This method has several important properties. The pixels of the resulting coadded image are uncorrelated. This image preserves all the information (from the original individual images) on all spatial frequencies. Any hypothesis testing or measurement that can be done on all the individual images simultaneously, can be done on the coadded image without any loss of information. The PSF of this image is typically as narrow, or narrower than the PSF of the best image in the ensemble. Moreover, this image is practically indistinguishable from a regular single image, meaning that any code that measures any property on a regular astronomical image can be applied to it unchanged. In particular, the optimal source detection statistic derived in Paper I is reproduced by matched filtering this image with its own PSF. This coaddition process, which we call proper coaddition, can be understood as the maximum signal-to-noise ratio measurement of the Fourier transform of the image, weighted in such a way that the noise in the entire Fourier domain is of equal variance. This method has important implications for multi-epoch seeing-limited deep surveys, weak lensing galaxy shape measurements, and diffraction-limited imaging via speckle observations. The last topic will be covered in depth in future papers. We provide an implementation of this algorithm in MATLAB.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient Precoding for Single Carrier Modulation in Multi-User Massive MIMO Networks

Abstract—Frequency domain (FD) multi-user detection (MUD) and precoding has been shown to be an effective means of approaching the theoretical per-user capacity for single carrier modulation (SCM) schemes in massive MIMO scenarios with highly dispersive channels. When a cyclic prefix is added to the SCM waveform, the circulant structures of the resulting convolutional channel matrix allows for relatively simple expressions for the FD detection and precoding. In this paper, we further refine the computationally efficient minimum mean squared error (MMSE) FD-MUD technique in a time-division duplexing (TDD) massive MIMO setup by pre-computing the scale factor needed to produce an unbiased estimate. The resulting scale factor and the matrix inverse that was calculated for the uplink is then reused for the downlink to form a computationally efficient precoding scheme with superior performance compared to zero-forcing (ZF) precoding. Performance analysis is provided and confirmed through simulation results.

5G and Beyond Communications↗

Fast Megavoltage Computed Tomography: A Rapid Imaging Method for Total Body or Marrow Irradiation in Helical Tomotherapy

Purpose: Megavoltage computed tomographic (MVCT) imaging has been widely used for the 3-dimensional (3-D) setup of patients treated with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, the result of slow couch speeds of approximately 1 mm/s, which can be difficult for the patient to tolerate. We sought to develop an MVCT imaging method allowing faster couch speeds and to assess its accuracy for image guidance for HT. Methods and Materials: Three cadavers were scanned 4 times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm with a penalty term of total variation and with a conventional filtered back projection (FBP) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors from the 2 reconstruction algorithms were compared. This fast MVCT imaging was tested in 3 cases of total marrow irradiation as a clinical trial. Results: The 3-D registration errors of the MVCT images reconstructed with the IR algorithm were smaller than the errors of images reconstructed with the FBP algorithm at fast couch speeds (2, 3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, faster MVCT (3 mm/s couch speed) scanning reduced the imaging time and still generated images useful for anatomic registration. Conclusions: Fast MVCT with the IR algorithm is clinically feasible for large 3-D target localization, which may reduce the overall time for the treatment procedure. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area. Automated integration of this imaging is at least needed to further assess its clinical benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-parametric approach towards the assessment of radon and thoron progeny exposures

Conventionally, the dosimetry is carried out using radon and thoron gas concentration measurements and doses have been assigned using assumed equilibrium factors for the progeny species, which is inadequate pertaining to the variations in equilibrium factors and possibly due to significant thoron. In fact, since the true exposures depend upon the intricate mechanisms of progeny deposition in the lung, therefore an integrated approach for the assessment of progeny is essential. In this context, the recently developed deposition based progeny concentration measurement techniques (DTPS: Direct Thoron progeny sensors and DRPS: Direct Radon progeny sensors) appear to be best suited for radiological risk assessments both among occupational workers and general study populations. DTPS and DRPS consist of aluminized mylar mounted LR115 type passive detectors, which essentially detects the alpha particles emitted from the deposited progeny atoms on the detector surface. It gives direct measure of progeny activity concentrations in air. DTPS has a lower limit of detection limit of 0.1 Bq/m{sup 3} whereas that for DRPS is 1 Bq/m{sup 3}, hence are perfectly suitable for indoor environments. These DTPS and DRPS can be capped with 200-mesh type wire-screen to measure the coarse fraction of the progeny concentration and the corresponding coarse fraction deposition velocities as well as the time integrated fine fraction. DTPS and DRPS can also be lodged in an integrated sampler wherein the wire-mesh and filter-paper are arranged in an array in flow-mode, to measure the fine and coarse fraction concentration separately and simultaneously. The details are further discussed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage with over 2,000 casks already loaded. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980's. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies' location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis , rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗