Silica structural changes induced by thermal treatment or ionic implantation as probed by IR reflectance spectroscopy

Fourier transformed infrared microreflectance spectroscopy is used to probe and compare the consequences of thermal quenching or ionic implantation on the structure of silica. A linear change in the main structural feature associated with Si-O-Si vibration with fictive temperature (T{sub f}) is observed up to T{sub f}=1400 deg. C. Ionic implantation is shown to shift the frequency of the main IR Si-O-Si vibration toward much lower wavenumbers, for all deposited energies, indicating that a comparison can be drawn between fictive temperature and irradiation effects. Extrapolating the linear changes in the IR structural bands obtained as a function of T{sub f} for the implanted samples, we show that two structural (nu{sub TO}) and (nu{sub B}) contributions are not affected by ionic implantation, as they would be by a unique very high T{sub f}. In the case of ionic implantation, we also evidence the development of some specific structural contributions indicating a depolymerization of silica network.

36 MATERIALS SCIENCE↗

Ion beam sputtering of silicon: Energy distributions of sputtered and scattered ions

The properties of sputtered and scattered ions are studied for ion beam sputtering of Si by bombardment with noble gas ions. The energy distributions in dependence on ion beam parameters (ion energy: 0.5-1 keV; ion species: Ne, Ar, Xe) and geometrical parameters (ion incidence angle, polar emission angle, and scattering angle) are measured by means of energy-selective mass spectrometry. The presence of anisotropic effects due to direct sputtering and scattering is discussed and correlated with process parameters. The experimental results are compared to calculations based on a simple elastic binary collision model and to simulations using the Monte-Carlo code SDTRIMSP . The influence of the contribution of implanted primary ions on energy distributions of sputtered and scattered particles is studied in simulations. It is found that a 10% variation of the target composition leads to detectable but small differences in the energy distributions of scattered ions. Comparison with previously reported data for other ion/target configurations confirms the presence of similar trends and anisotropic effects: The number of high-energy sputtered ions increases with increasing energy of incident ions and decreasing scattering angle. The effect of the ion/target mass ratio is additionally investigated. Small differences are observed with the change of the primary ion species: The closer the mass ratio to unity, the higher the average energy of sputtered ions. Finally, the presence of peaks, assigned to different mechanisms of direct scattering, strongly depends on the ion/target mass ratio.

42 ENGINEERING↗

Structural Transformation of “Silica+Zn” Nanocomposite after Annealing in Oxidizing Atmosphere

It has been found that “hot” high-fluence Zn{sup +} implantation leads to the formation of the extended layer with zinc-based nanoclusters of size up to 10 nm in SiO{sub 2} film. The precipitate’s crystalline nature is confirmed by HRTEM studies. Post-implantation annealing at 700°C for 60 min leads to Zn atoms redistribution in implanted region, formation of the larger crystallites (up to 25 nm) and the small Zn nanoparticles surrounded by the oxide shells (core (Zn)/shell(ZnO) structure) as well as the voids formation at the interface “Zn nanocluster/SiO{sub 2} matrix”. The number of the core (Zn)/shell (ZnO) structures and the voids increases after annealing at 700°C for 120 min.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Material Research Using Moessbauer Spectroscopy With Exotic Nuclei

We have succeeded to obtain in-beam Moessbauer spectra using a short-lived {sup 57}Mn (T{sub 1/2} = 1.45 min) probes implanted into some different types of samples, in order to study the chemical states of the excited atoms produced just after nuclear decays and/or the dynamic behaviors of isolated single atoms in a semiconductor. {sup 57}Mn was produced as a radioactive beam following a nuclear projectile-fragmentation reaction of {sup 58}Fe{sup 21+} beams (E = 63 MeV/nucleon) with Be production target, and separated by the in-flight isotope separator at the accelerators in RIKEN Nishina Center. From the temperature dependence of obtained Moessbauer parameters of the isomer shift (I.S.), the quadrupole splitting (Q.S.), and the linewidth (I), the chemical species and the dynamic behavior of the isolated atoms could be discussed. The in-beam Moessbauer technique combined with a short-lived RI beam is a very powerful tool to investigate the products after nuclear transformations and the dynamics of dilute impurities in solids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Si film separation obtained by high energy proton implantation

High energy protons implantation in the 1-1.5 MeV range can be used to detach free-standing thin silicon films with thickness between 15 and 30 {mu}m. Recently, we showed that Si orientation has a strong effect on the layer separation threshold fluence and efficiency. While complete delamination of (111)Si films is achieved, (100)Si films separation is more challenging due to blistering phenomena or partial separation of the implanted layer. In this work, we study the fracture mechanism in (100) and (111)Si after high energy implantation in order to understand the origin of such a behavior. We notably point out that fracture precursor defects, i.e. the platelets, preferentially form on (111) planes, as a consequence of the low strain level in the damaged region in our implantation conditions. Fracture therefore propagates easily in (111)Si, while it requires higher fluence to overcome unfavorable precursors orientation and propagate in (100)Si.

36 MATERIALS SCIENCE↗

Influence of in situ applied ultrasound during Si{sup +} implantation in SiO{sub 2} on paramagnetic defect generation

Electron spin resonance (ESR) results are presented on the influence of in situ ultrasound treatment (UST) during implantation at 300 K of Si{sup +} ions into thermal SiO{sub 2} on (100)Si before and after subsequent high-temperature (T) annealing (1100 deg. C) intended to promote the formation of embedded Si nanoparticles. The as-implanted state exhibits high densities of three prominent types of point defects, including the SiO{sub 2}-specific S and E{sup '}{sub {gamma}} O-vacancy type centers, and an unknown broad ({approx_equal}20 G) signal at g{approx_equal}2.0026 denoted IS. The high-intensity S signal shows demagnetization shape effects, pointing to a distribution of high local density of defects over a thin layer. UST is observed to effectuate a drastic reduction in S and E{sup '}{sub {gamma}} centers, and elimination of IS beyond detection. This reveals a strong healing influence of in situ transferred ultrasound (US) energy on implantation-induced damage, here quantified and identified on atomic level in terms of mainly intrinsic paramagnetic point defects elimination, viz., Frenkel pair elimination, while all three initial signals disappear. Other types of defects surface after annealing of the non-US treated sample, including the SiO{sub 2}-specific EX defect signal and P{sub b}-type Si/SiO{sub 2} interface centers, the appearance of the latter providing direct ESR evidence for crystallization of the excess Si nanoparticles. The influence of the UST healing effect is kept up after subsequent annealing, now resulting in the absence of virtually all ESR-active centers. The drop in P{sub b}-type centers below the detection level in the UST annealed sample indicates improvement of the nanocrystalline-Si/SiO{sub 2} interface quality. The combination of UST with high-T annealing emerges as a highly efficient means to eradicate ion implantation damage in terms of intrinsic point defects.

36 MATERIALS SCIENCE↗

Stability, Electronic and Magnetic Properties of Rare Earth (Eu, Tm) Implanted InGaN

The electronic structure and magnetic behavior of InGaN:RE (RE = Eu, Tm) have been studied by using scalar relativistic full-potential linear augmented-plane-wave plus local orbital (FPLAPW + lo) calculations with LSDA+U approximation. Band structure and density of states are analyzed. It appears that the In-site is the preferred site for doping InGaN alloy with rares earth (Eu, Tm) from the formation energy. Our study reveals that these materials are semiconductors with a direct band gap of 1.2345 eV and 1.3657 eV for InGaN:Eu and InGaN:Tm respectively. The total energy of the FM phase is lower than the AFM total energy; this confirms the fact that the ground state at zero temperature is ferromagnetic. A small-induced magnetic moment on other nonmagnetic atoms (Ga, In, and N) and the total magnetic moment of these compounds is mainly due to RE-4f states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FASTGRASS implementation in BISON and Fission gas behavior characterization in UO 2 and connection to validating MARMOT

This activity is supported by the US Nuclear Energy Advanced Modeling and Simulation (NEAMS) Fuels Product Line (FPL). Two major accomplishments in FY 15 are summarized in this report: (1) implementation of the FASTGRASS module in the BISON code; and (2) a Xe implantation experiment for large-grained UO 2 . Both BISON AND MARMOT codes have been developed by Idaho National Laboratory (INL) to enable next generation fuel performance modeling capability as part of the NEAMS Program FPL. To contribute to the development of the Moose-Bison-Marmot (MBM) code suite, we have implemented the FASTGRASS fission gas model as a module in the BISON code. Based on rate theory formulations, the coupled FASTGRASS module in BISON is capable of modeling LWR oxide fuel fission gas behavior and fission gas release. In addition, we conducted a Xe implantation experiment at the Argonne Tandem Linac Accelerator System (ATLAS) in order to produce the needed UO 2 samples with desired bubble morphology. With these samples, further experiments to study the fission gas diffusivity are planned to provide validation data for the Fission Gas Release Model in MARMOT codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kinetic Monte Carlo simulation of dopant-defect systems under submicrosecond laser thermal processes

An innovative Kinetic Monte Carlo (KMC) code has been developed, which rules the post-implant kinetics of the defects system in the extremely far-from-the equilibrium conditions caused by the laser irradiation close to the liquid-solid interface. It considers defect diffusion, annihilation and clustering. The code properly implements, consistently to the stochastic formalism, the fast varying local event rates related to the thermal field T(r,t) evolution. This feature of our numerical method represents an important advancement with respect to current state of the art KMC codes. The reduction of the implantation damage and its reorganization in defect aggregates are studied as a function of the process conditions. Phosphorus activation efficiency, experimentally determined in similar conditions, has been related to the emerging damage scenario.

36 MATERIALS SCIENCE↗

Microstructural Effects of High Dose Helium Implantation in ErD 2

Metal hydrides can store hydrogen isotopes with high volumetric density. In metal tritides, tritium beta decay can result in accumulation of helium within the solid, in some cases exceeding 10 at.% helium after only 4 years of aging. Helium is insoluble in most materials, but often does not readily escape, and instead coalesces to form nanoscale bubbles when helium concentrations are near 1 at.%. Blistering or spallation often occurs at higher concentrations. Radioactive particles shed during this process present a potential safety hazard. This study investigates the effects of high helium concentrations on erbium deuteride (ErD 2 ), a non-radioactive surrogate material for erbium tritide (ErT 2 ). To simulate tritium decay in the surrogate, high doses of 120 keV helium ions were implanted into ErD 2 films at room temperature. Scanning and transmission electron microscopy indicated spherical helium bubble formation at a critical concentration of 1.5 at.% and bubble linkage leading to nanoscale crack formation at a concentration of 7.5 at.%. Additionally, crack propagation occurred through the nanocrack region, resulting in spallation extending from the implantation peak to the surface. Electron energy loss spectroscopy was utilized to confirm the presence of high-pressure helium in the nanocracks, suggesting that helium gas plays a predominant role in deformation. This work improves the overall understanding of helium behavior in ErD 2 by using modern characterization techniques to determine: the critical helium concentration required for bubble formation, the material failure mechanism at high concentration, and the nanoscale mechanisms responsible for material failure in helium implanted ErD 2 .

36 MATERIALS SCIENCE↗

A Concept for a Low Pressure Noble Gas Fill Intervention in the IFE Fusion Test Facility (FTF) Target Chamber

An engineering evaluation has been initiated to investigate conceptual engineering methods for implementing a viable gas shield strategy in the Fusion Test Facility (FTF) target chamber. The employment of a low pressure noble gas in the target chamber to thermalize energetic helium ions prior to interaction with the wall could dramatically increase the useful life of the first wall in the FTF reactor1. For the purpose of providing flexibility, two target chamber configurations are addressed: a five meter radius sphere and a ten meter radius sphere. Experimental studies at Nike have indicated that a low pressure, ambient gas resident in the target chamber during laser pulsing does not appear to impair the ability of laser light from illuminating targets2. In addition, current investigations into delivering, maintaining, and processing low pressure gas appear to be viable with slight modification to current pumping and plasma exhaust processing technologies3,4. Employment of a gas fill solution for protecting the dry wall target chamber in the FTF may reduce, or possibly eliminate the need for other attenuating technologies designed for keeping He ions from implanting in first wall structures and components. The gas fill concept appears to provide an effective means of extending the life of the first wall while employing mostly commercial off the shelf (COTS) technologies. Although a gas fill configuration may provide a methodology for attenuating damage inflicted on chamber surfaces, issues associated with target injection need to be further analyzed to ensure that the gas fill concept is viable in the integrated FTF design5. In the proposed system, the ambient noble gas is heated via the energetic helium ions produced by target detonation. The gas is subsequently cooled by the chamber wall to approximately 800oC, removed from the chamber, and processed by the chamber gas processing system (CGPS). In an optimized scenario of the above stated concept, the chamber wall acts as the primary heat exchanger. During removal, gas is pumped through the laser ports by turbo molecular-drag pumps (TM-DP). For the purpose of reducing organic based lubricants and seals, a magnetically levitated TM-DP is being investigated with pump manufacturers. Currently, magnetically levitated turbo molecular pumps are commercially available. The pumps will be exposed to thermal loads and ionizing radiation (tritium, Ar-41, post detonation neutrons). Although the TM-DP's will be subjected to these various radiations, current designs for similar pumping devices have been hardened and have the ability of locating control electronics in remote radiation shielded enclosures4. The radiation hardened TM-DP's will be 5 required to operate with minimal maintenance for periods of up to 18 continuous months. As part of this initial investigation for developing a conceptual engineering strategy for a gas fill solution, commercial suppliers of low pressure gas pumping systems have been contacted and engaged in this evaluation. Current technology in the area of mechanical pumping systems indicates that the development of a robust pumping system to meet the requirements of the FTF gas fill concept is within the limits of COTS equipment3,4.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Ultra Small Scale Mechanical Testing and Localized He Implantation for Nuclear Applications

Mechanical properties degradation of components deployed in nuclear applications has been a concern since the deployment of first generation nuclear power plants. Radiation damage along with environmental degradation, elevated temperatures, and long term deployment of nuclear structures pose a challenging environment for all materials in these applications. Traditionally, the mechanical properties are assessed by standardized macroscopic testing methods. While those are providing engineering relevant data these techniques do have limitations, especially on reactor irradiated materials, due to the large size of the samples. Limitations on the amount of radioactivity of large samples must be applied for research applications as they are conducted at universities. In addition it can be difficult to retrieve sufficiently large amounts of material from an operating reactor component. Therefore smaller sample sizes are desirable and reduce the amount of radioactive material which needs to be handled or material which needs to be retrieved. In addition, the number of tests which can be performed on materials irradiated in a test reactor program is limited due to limited space in specific dose and temperature positions. Downsizing of the mechanical test can overcome this issue and perform more tests on the same amount of irradiated materials, reducing the statistical uncertainties. In addition, smaller scale samples allow access to specific regions of interest in a material or component, be it the zone in front of a crack tip or the sampling of very small components like springs or welded areas. In addition ion beam irradiation has become an integral part of nuclear materials research to enhance the understanding of radiation damage in materials in a time and cost effective fashion. The drawback of ion beam irradiation is the small penetration depth of the ions into the material making localized microstructural characterization as well as small scale mechanical testing necessary. Another more fundamental motivation is the fact that since the beginning of electron microscopy, one has been concerned about imaging and quantifying defects in materials. Multiscale tools to image a large range of radiation induced defects have been established starting from atom probe tomography to transmission electron microscopy, up to scattering techniques. Mechanical testing, however, has always been performed on a large scale, and an attempt to match the same scale where a defect is observed with the materials' mechanical property response has not yet been realized. However, the question of separate effects testing on specific radiation induced defects remains and is an additional driving force for small scale mechanical testing. In this work we present an approach for small scale mechanical testing in irradiated materials and the variety of possible test methods developed today. We also present recent efforts of performing localized ion beam implantation to achieve a number of different doses in the same region of interest enhancing comparability and quantification of observed phenomena. It is the intention to give the reader an overview of the different microscale mechanical testing techniques possible today as well as an introduction of a novel ion beam irradiation method using a newly established capability. In this paper we can't discuss all aspects of all small scale mechanical testing of irradiated materials However, It does give an overview over the techniques enabled due to recent effort and enhanced instrument capability. While indentation or micro compression testing has been performed previously tensile testing and ion beam irradiation using the He ion beam microscope are novel approaches not attempted previously. (authors)

36 MATERIALS SCIENCE↗

Suppressed gross erosion of high-temperature lithium via rapid deuterium implantation

Lithium-coated high-Z substrates are planned for use in the NSTX-U divertor and are a candidate plasma facing component (PFC) for reactors, but it remains necessary to characterize the gross Li erosion rate under high plasma fluxes (>10 23 m -2 s -1 ), typical for the divertor region. In this work, a realistic model for the compositional evolution of a Li/D layer is developed that incorporates first principles molecular dynamics (MD) simulations of D diffusion in liquid Li. Predictions of Li erosion from a mixed Li/D material are also developed that include formation of lithium deuteride (LiD). The erosion rate of Li from LiD is predicted to be significantly lower than from pure Li. This prediction is tested in the Magnum-PSI linear plasma device at ion fluxes of 10 23 -10 24 m -2 s -1 and Li surface temperatures. ≤800 °C. Li/LiD coatings ranging in thickness from 0.2 to 500 μm are studied. The dynamic D/Li concentrations are inferred via diffusion simulations. The pure Li erosion rate remains greater than Langmuir Law evaporation, as expected. For mixed-material Li/LiD surfaces, the erosion rates are reduced, in good agreement with modelling in almost all cases. Lastly, these results imply that the temperature limit for a Li-coated PFC may be significantly higher than previously imagined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an in situ ion irradiation scanning electron microscope

An in situ ion irradiation scanning electron microscope (I 3 SEM) has been developed, installed, and integrated into the Ion Beam Laboratory at Sandia National Laboratories. The I 3 SEM facility combines a field emission, variable pressure, scanning electron microscope, a 6 MV tandem accelerator, high flux low energy ion source, an 808 nm-wavelength laser, and multiple stages to control the thermal and mechanical state of the sample observed. The facility advances real-time understanding of materials evolution under combined environments at the mesoscale. As highlighted in multiple examples, this unique combination of tools is optimized for studying mesoscale material response in overlapping extreme environments, allowing for simultaneous ion irradiation, implantation, laser bombardment, conductive heating, cooling, and mechanical deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Redistribution of Erbium and Oxygen Recoil Atoms and the Structure of Silicon Thin Surface Layers Formed by High-Dose Argon Implantation through Er and SiO{sub 2} Surface Films

Using analytical high-resolution electron microscopy, the Si structure and the redistribution of Er and O recoil atoms embedded in thin (~10 nm) surface layers by Ar{sup +} implantation with an energy of 250–290 keV and a dose of 1 × 10{sup 16} cm{sup –2} through Er and SiO{sub 2} films, respectively, and subsequent annealing are studied. It is established that Si recrystallization fails at a distance of ~20 nm from the surface, where the erbium concentration of 5 × 10{sup 19} cm{sup –3} critical for failure is achieved at T = 950°C. It disproves the generally accepted model of Er-atom transfer by the recrystallization front into SiO{sub 2} on the surface. Instead, it is shown that the redistribution of O recoil atoms to the initial oxide during annealing for immobile Er atoms provides the formation of surface-inhomogeneous erbium phases in such a way that the oxygen-enriched Er–Si–O phase turns out to be concentrated in the oxide, while the depleted Er–Si phase remains in Si. It explains the partial loss of implanted Er after removal of the oxide together with the Er–Si–O phase. It was shown that the formation of a high density of microtwins (locally up to 10{sup 13} cm{sup –2}) is associated with the formation of Ar bubbles and clusters, which is atypical for (100)–Si recrystallization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-voltage (1800 V) planar 4H-SiC p-n junctions with floating guard rings

Planar 4H-SiC p-n junctions with floating guard rings have been fabricated. The main junction and the rings were formed by room temperature boron implantation followed by high temperature annealing. The breakdown voltage of the p-n junctions is 1800 V, which twice exceeds that of similar junctions without guard rings and reaches 72% of the calculated breakdown voltage of a plane-parallel p-n junction with the same epitaxial layer parameters.

36 MATERIALS SCIENCE↗

Efficient oxygen gettering in Si by coimplantation of hydrogen and helium

Hydrogen preimplantation performed in addition to helium implantation efficiently shrinks the width of the gettering layer in Si and increases the empty volume fraction as well as the internal surface area per unit volume. The gettering efficiency for oxygen is significantly enhanced compared to the single helium implantation, and the helium implantation dose can be strongly reduced. The gas-filled bubble layer induced by the coimplantation of hydrogen and helium has the highest gettering efficiency for the oxygen accumulation. Direct evidence for oxygen gettering at the internal wall of the cavity is demonstrated by cross-sectional transmission electron microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗