Search NASA⌕ Search

SEARCH · Search NASA

Results for “Learning control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

FAIR Data and Interpretable AI Framework for Architectured Metamaterials

Our interdisciplinary effort successfully generated FAIR (Findable, Accessible, Interoperable, and Reusable) benchmark datasets for mechanical metamaterials while introducing a novel Artificial Intelligence (AI) framework known as Learning Refined Compositional Rules (LRCR). This framework was specifically designed to bridge the gap across varying computational length scales and extract the underlying physical mechanisms that connect a material's structural geometry to its bulk acoustic properties. Historically, the discovery of such structured materials relied heavily on human intuition or opaque, black-box optimization algorithms that were difficult to generalize. By combining interpretable machine learning techniques with rigorous experimental validation, this project established clear, generalizable design guidelines for tuning wave dispersion and controlling vibrations. Ultimately, the public availability of these structured datasets and algorithms will significantly reduce computational costs and accelerate the design of advanced multi-functional acoustic devices, offering broad societal impacts across fields like aerospace engineering, telecommunications, and biomedical implant design.

36 MATERIALS SCIENCE↗

Wind Turbine Gearbox Failure Detection Through Cumulative Sum of Multivariate Time Series Data

The wind energy industry is continuously improving their operational and maintenance practice for reducing the levelized costs of energy. Anticipating failures in wind turbines enables early warnings and timely intervention, so that the costly corrective maintenance can be prevented to the largest extent possible. It also avoids production loss owing to prolonged unavailability. One critical element allowing early warning is the ability to accumulate small-magnitude symptoms resulting from the gradual degradation of wind turbine systems. Inspired by the cumulative sum control chart method, this study reports the development of a wind turbine failure detection method with such early warning capability. Specifically, the following key questions are addressed: what fault signals to accumulate, how long to accumulate, what offset to use, and how to set the alarm-triggering control limit. We apply the proposed approach to 2 years’ worth of Supervisory Control and Data Acquisition data recorded from five wind turbines. We focus our analysis on gearbox failure detection, in which the proposed approach demonstrates its ability to anticipate failure events with a good lead time.

17 WIND ENERGY↗

Atomic-scale factors that control the rate capability of nanostructured amorphous Si for high-energy-density batteries

Nanostructured Si is the most promising high-capacity anode material to substantially increase the energy density of Li-ion batteries. Among the remaining challenges is its low rate capability as compared to conventional materials. To understand better what controls the diffusion of Li in the amorphous Li-Si alloy, we use a novel machine-learning potential trained on more than 40,000 ab-initio calculations and nanosecond-scale molecular dynamics simulations, to visualize for the first time the delithiation of entire LiSi nanoparticles. Our results show that the Si host is not static but undergoes a dynamic rearrangement from isolated atoms, to chains, and clusters, with the Li diffusion strongly governed by this Si rearrangement. We find that the Li diffusivity is highest when Si segregates into clusters, so that Li diffusion proceeds via hopping between the Si clusters. The average size of Si clusters and the concentration range over which Si clustering occurs can thus function as design criteria for the development of rate-improved anodes based on modified Si.

Artrith, Nongnuch↗

Is Entombment an Acceptable Option for Decommissioning? An International Perspective - 13488

Selection of a decommissioning strategy is one of the key steps in the preparation for decommissioning of nuclear facilities and other facilities using radioactive material. Approaches being implemented or considered by Member States include immediate dismantling, deferred dismantling and entombment. Other options or slight modifications of these strategies are also possible. Entombment has been identified in the current International Atomic Energy Agency (IAEA) Safety Standards as one of the three basic decommissioning strategies and has been defined as a decommissioning strategy by which radioactive contaminants are encased in a structurally long lived material until radioactivity decays to a level permitting the unrestricted release of the facility, or release with restrictions imposed by the regulatory body. Although all three strategies have been considered, in principle, applicable to all facilities, their application to some facilities may not be appropriate owing to political concerns, safety or environmental requirements, technical considerations, local conditions or financial considerations. The IAEA is currently revising the decommissioning Safety Standards and one of the issues widely discussed has been the applicability of entombment in the context of decommissioning and its general objective to enable removal of regulatory control from the decommissioned facility. The IAEA recently established a consultancy to collect and discuss experience and lessons learned from entombment projects, to identify regulatory requirements and expectations for applying entombment as a decommissioning option strategy, in compliance with the internationally agreed standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probabilistic-learning-based stochastic surrogate model from small incomplete datasets for nonlinear dynamical systems

We consider a high-dimensional nonlinear computational model of a dynamical system, parameterized by a vector-valued control parameter, in the presence of uncertainties represented by an uncontrolled parameter modeled by a vector-valued random variable, and possibly with stochastic excitation. The objective is to construct a statistical surrogate model where the input is any deterministic value of the control parameter, and the output is a vector-valued observation of the computational model, which is a random vector whose probability measure is updated using a target dataset. To construct this statistical surrogate model, the stochastic response of the computational model must be built, which is a vector-valued time-discretized stochastic process in high dimension, depending on the control parameter. It is assumed that the computational cost of a single evaluation of the deterministic model is high. For the probabilistic updating, we consider a subset of the components of the observation of the computational model, defined as the “identification observation” of the computational model, for which a small target dataset is available. Therefore, the target dataset is associated with partial observability, corresponding to an incomplete data case. Given a prior probability model of the random control and uncontrolled parameters, a training dataset is constructed, consisting of realizations of the random triplet composed of the stochastic response, the random identification observation, and the random control parameter. Since the computational cost of a single evaluation of the deterministic model is assumed to be large, the training dataset is also of small size. The main challenges in this problem are the high dimensionality, partial observability leading to incomplete data in the target dataset for the identification observation of the computational model (which is not sufficient to identify the computational stochastic responses), and the availability of a small training dataset. To address these challenges, we propose a methodology based on statistical methods for constructing necessary reduced representations, direct probabilistic learning under constraints using probabilistic learning on manifolds (PLoM) constrained by the target dataset, and the use of a weak formulation of the Fourier transform of probability measures. Statistical conditioning is also employed to explore the learned dataset. The constructed predictive statistical surrogate model can be implemented in the context of online computation. Here, we apply this approach to a problem of nonlinear stochastic dynamics in high dimensions within the framework of deformable solids mechanics.

Engineering↗

Machine learning-guided discovery of gas evolving electrode bubble inactivation

The adverse effects of electrochemical bubbles on the performance of gas-evolving electrodes are well known, but studies on the degree of adhered bubble-caused inactivation, and how inactivation changes during bubble evolution are limited. We study electrode inactivation caused by oxygen evolution while using surface engineering to control bubble formation. We find that the inactivation of the entire projected area, as is currently believed, is a poor approximation which leads to non-physical results. Using a machine learning-based image-based bubble detection method to analyze large quantities of experimental data, we show that bubble impacts are small for surface engineered electrodes which promote high bubble projected areas while maintaining low direct bubble contact. We thus propose a simple methodology for more accurately estimating the true extent of bubble inactivation, which is closer to the area which is directly in contact with the bubbles.

Lake, Jack R.↗

A Dynamic Hierarchical Attention Framework for Multimodal Malware Detection

The increasing use of Android in the worldwide mobile ecosystem has come along with a significant increase in advanced malware, highlighting the critical necessity for efficient, scalable, and adaptable detection systems. Despite recent advancements in machine learning improving malware detection, the majority of current solutions are limited to one, two, or three data modalities, hence neglecting the comprehensive behavioral spectrum of contemporary multi-vector threats. This thesis presents the first comprehensive multimodal framework for Android malware detection, which combines textual, time-series (temporal), graph-based (structural), and visual information using an innovative hierarchical attention mechanism and Dynamic Fusion Controller (DFC). Our methodology consistently classifies and processes modalities as either sequential or structural, facilitating content-adaptive weighting and resilient cross-modal representation learning. We advance the implementation of cutting-edge time series techniques, such as MiniRocket, for malware detection, hence creating new opportunities for temporal analysis in cybersecurity. Comprehensive experimental assessment shows that our framework performs exceptionally well, with 99.46% classification accuracy and 97.15% detection accuracy, significantly outperforming existing approaches through effective multimodal integration and hierarchical attention mechanisms.

Nazmin, Tamanna↗

Overall results of and lessons learned from the IAEA CRP on sodium natural circulation test performed during the Phenix end-of-life experiments

In 2007, the International Atomic Energy Agency (IAEA) launched the Coordinated Research Project (CRP) 'Control Rod Withdrawal and Sodium Natural Circulation Tests Performed during the Phenix End-of-Life Experiments'. The overall purpose of the CRP, performed within the framework of the IAEA programme in support of innovative fast reactor technology development and deployment, is to improve the Member States' analytical capabilities in the various fields of research and design of sodium-cooled fast reactors through data and codes verification and validation. In particular the CRP, taking advantage of the End-of-Life set of experiments performed before the final shut-down of the French prototype fast breeder power reactor Phenix, aims at improving fast reactor simulation methods and design capabilities in the field of temperature and power distribution evaluation, as well as of the analysis of sodium natural circulation phenomena. The paper presents the overall results of the CRP, including blind calculations and post-test and sensitivity analyses carried out by the CRP participants, as well as lessons learned and recommendations for further future implementations to resolve open issues. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

MO-AB-210-03: Workshop [ Advancements in high intensity focused ultrasound ]

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Convex Q-Learning in Continuous Time with Application to Dispatch of Distributed Energy Resources

Convex Q-learning is a recent approach to reinforcement learning, motivated by the possibility of a firmer theory for convergence, and the possibility of making use of greater a priori knowledge regarding policy or value function structure. This paper explores algorithm design in the continuous time domain, with a finite-horizon optimal control objective. The main contributions are (i) The new Q-ODE: a model-free characterization of the Hamilton-Jacobi-Bellman equation. (ii) A formulation of Convex Q-learning that avoids approximations appearing in prior work. The Bellman error used in the algorithm is defined by filtered measurements, which is necessary in the presence of measurement noise. (iii) Convex Q-learning with linear function approximation is a convex program. It is shown that the constraint region is bounded, subject to an exploration condition on the training input. (iv) The theory is illustrated in application to resource allocation for distributed energy resources, for which the theory is ideally suited.

Lu, Fan↗

MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Computationally Efficient Learning of Large Scale Dynamical Systems: A Koopman Theoretic Approach

In recent years there has been a considerable drive towards data-driven analysis, discovery and control of dynamical systems. To this end, operator theoretic methods, namely, Koopman operator methods have gained a lot of interest. In general, the Koopman operator is obtained as a solution to a least-squares problem, and as such, the Koopman operator can be expressed as a closed-form solution that involves the computation of Moore-Penrose inverse of a matrix. For high dimensional systems and also if the size of the obtained data-set is large, the computation of the Moore-Penrose inverse becomes computationally challenging. In this paper, we provide an algorithm for computing the Koopman operator for high dimensional systems in a time-efficient manner. We further demonstrate the efficacy of the proposed approach on two different systems, namely a network of coupled oscillators (with state-space dimension up to 2500) and IEEE 68 bus system (with state-space dimension 204 and up to 24,000 time-points).

Sinha, Subhrajit↗

MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Lessons learned enhancing EPICS CA for LANSCE timed and flavored data

A previous paper described an upgrade to EPICS enabling client side tools at LANSCE to receive subscription updates filtered selectively to match a logical configuration of LANSCE beam gates, as configured by the control room. The upgrade required fundamental changes in the EPICS core components. First, the event queue in the EPICS server was upgraded to buffer record (function block) and device specific parameters accessed generically via software interfaces for introspection of 3rd party data. In contrast, event queues in previous versions of EPICS were strictly limited to buffering only value, timestamp, and alarm status tuples. Second, the Channel Access server is being upgraded to filter subscription updates. In this follow on paper some necessary design changes mid-project and the lessons learned during the software development will be described.

43 PARTICLE ACCELERATORS↗

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗