Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Next Generation Co-Molded One-Piece Automotive Parts

The purpose of this project was to determine the feasibility of co-molding Class A Sheet Molding Compound (SMC), structural SMC, and continuous fiber prepreg materials to produce a single piece co-molded automotive part, such as a hood. The combination of the three molding materials and the incorporation of selective design features (ribs, flanges, corrugations) was expected to eliminate the need for inner reinforcement panels, significantly reducing tooling costs and simplifying the manufacturing process. A multi-material solution would also result in significant weight savings. The scope of this project included the material characterization of the three materials, development of cure and flow simulation models, and validation of the models against parts molded with different combinations of the materials on an 11”x11” plaque tool with rib features. The intent of this project was to apply the learnings obtained from co-molding a part with simplified geometry to a Phase 2 project that would produce a single piece hood, co-molded with the same materials. Resins from INEOS Composites were provided to IDI to produce SMC and continuous fiber prepregs. Purdue University and INEOS Composites characterized the rheological and curing behavior of the different materials as well as the mechanical properties of the co-molded parts. This data was used by Purdue University to create simulation models. Models were created to predict both flow patterns and predict mechanical properties of different laminate constructions in and around the ribs. Michigan State University - Corktown validated Purdue’s models by co-molding the three materials in different combinations on a tool containing rib features provided by Century Tool. The co-molded parts were evaluated against the simulation models by Purdue, Corktown and INEOS. The project team demonstrated the following: • The ability to obtain a cohesive co-molded structure made up of Class A SMC, Structural SMC, and continuous fiber prepreg. • The ability to obtain a co-molded part with a Class A surface • Modeling of flow and fiber orientation • Modeling to predict mechanical properties of multi-material co-molded structures The predicted flow behavior and fiber orientation from simulations were then compared with the molded samples. Exact local orientation state was difficult to compare between microscopy and flow simulation, but captured general trends. Multi-material flow behavior was generally modeled well with SMC materials, but the introduction of woven material sheets requires further model development. Purdue compared the predicted versus actual mechanical properties, and INEOS Composites evaluated the surface appearance of unpainted and painted co-molded parts. The models developed by Purdue demonstrated that the mechanical properties can be predicted for parts with varying material configurations. The resulting models can be applied to future co-molded part design, tooling design, and molding conditions.

36 MATERIALS SCIENCE↗

Lidar measurements of yawed-wind-turbine wakes: characterization and validation of analytical models

Abstract. Wake measurements of a scanning Doppler lidar mounted on the nacelle of a full-scale wind turbine during a wake-steering experiment were used for the characterization of the wake flow, the evaluation of the wake-steering set-up, and the validation of analytical wake models. Inflow-scanning Doppler lidars, a meteorological mast, and the supervisory control and data acquisition (SCADA) system of the wind turbine complemented the set-up. Results from the wake-scanning Doppler lidar showed an increase in the wake deflection with the yaw angle and that the wake deflection was not in all cases beneficial for the power output of a downstream turbine due to a bias of the inflow wind direction perceived by the yawed wind turbine and the wake-steering design implemented. Both observations could be reproduced with an analytical model that was initialized with the inflow measurements. Error propagation from the inflow measurements that were used as model input and the power coefficient of a waked wind turbine contributed significantly to the model uncertainty. Lastly, the span-wise cross section of the wake was strongly affected by wind veer, masking the effects of the yawed wind turbine on the wake cross sections.

17 WIND ENERGY↗

Quantifying metal-binding specificity of Cc NikZ-II from Clostridium carboxidivorans in the presence of competing metal ions

Many proteins bind transition metal ions as cofactors to carry out their biological functions. Despite binding affinities for divalent transition metal ions being predominantly dictated by the Irving-Williams series for wild-type proteins, in vivo metal ion binding specificity is ensured by intracellular mechanisms that regulate free metal ion concentrations. However, a growing area of biotechnology research considers the use of metal-binding proteins in vitro to purify specific metal ions from wastewater, where specificity is dictated by the protein's metal binding affinities. A goal of metalloprotein engineering is to modulate these affinities to improve a protein's specificity towards a particular metal; however, the quantitative relationship between the affinities and the equilibrium metal-bound protein fractions depends on the underlying binding mechanisms. Here we demonstrate a high-throughput intrinsic tryptophan fluorescence quenching method to validate binding models in multi-metal solutions for CcNikZ-II, a nickel-binding protein from Clostridium carboxidivorans. Using our validated models, we quantify the relationship between binding affinity and specificity in different classes of metal-binding models for CcNikZ-II. In conclusion, we further illustrate the potential relevance of data-informed models to predicting engineering targets for improved specificity.

59 BASIC BIOLOGICAL SCIENCES↗

Crystal Plasticity Modeling and Experimental Validation with an Orientation Distribution Function for Ti-7Al Alloy

An orientation distribution function based model is used for micromechanical modeling of the titanium-aluminum alloys, Ti-0 wt % Al and Ti-7 wt % Al, which are in demand for many aerospace applications. This probability descriptor based modeling approach is different than crystal plasticity finite element techniques since it computes the averaged material properties using upper bound averaging. A rate-independent single-crystal plasticity model is implemented to compute the effect of macroscopic strain on the polycrystal. An optimization problem is defined for calibrating the basal, prismatic, pyramidal slip system and twin parameters using the available tension and compression experimental data. The crystal plasticity parameters of Ti-7 wt % Al are not studied extensively in literature, and therefore the optimization results for the crystal plasticity model realization produce unique data, which will be beneficial to future studies in the field. The sensitivities of the slip and twin parameters to the design objectives are also investigated to identify the most critical slip system parameters. Using the optimum design parameters, the microstructural textures, during the tension test, are predicted by the crystal plasticity finite element simulations, and compared to the available experimental texture and scanning electron microscope—digital image correlation data.

36 MATERIALS SCIENCE↗

OC6 project Phase IV: validation of numerical models for novel floating offshore wind support structures

Abstract. This paper provides a summary of the work done within Phase IV of the Offshore Code Comparison Collaboration, Continued with Correlation and unCertainty (OC6) project, under International Energy Agency Wind Technology Collaboration Programme Task 30. This phase focused on validating the loading on and motion of a novel floating offshore wind system. Numerical models of a 3.6 MW horizontal-axis wind turbine atop the TetraSpar floating support structure were compared using measurement data from a 1:43-Froude-scale test performed in the University of Maine's Alfond Wind–Wave (W2) Ocean Engineering Laboratory. Participants in the project ran a series of simulations, including system equilibrium, surge offsets, free-decay tests, wind-only conditions, wave-only conditions, and a combination of wind and wave conditions. Validation of the models was performed by comparing the aerodynamic loading, floating support structure motion, tower base loading, mooring line tensions, and keel line tensions. The results show a relatively good estimation of the aerodynamic loading and a reasonable estimation of the platform motion and tower base fore–aft bending moment. However, there is a significant dispersion in the dynamic loading for the upwind mooring line. Very good agreement was observed between most of the numerical models and the experiment for the keel line tensions.

17 WIND ENERGY↗

Development and validation of a mathematical model of heart rate response to fluid perturbation

Physiological closed-loop controlled (PCLC) medical devices monitor and automatically adjust the patient’s condition by using physiological variables as feedback, ideally with minimal human intervention to achieve the target levels set by a clinician. PCLC devices present a challenge when it comes to evaluating their performance, where conducting large clinical trials can be expensive. Virtual physiological patients simulated by validated mathematical models can be utilized to obtain preclinical evidence of safety and assess the performance of the PCLC medical device during normal and worst-case conditions that are unlikely to happen in a limited clinical trial. A physiological variable that plays a major role during fluid resuscitation is heart rate (HR). For in silico assessment of PCLC medical devices regarding fluid perturbation, there is currently no mathematical model of HR validated in terms of its predictive capability performance. This paper develops and validates a mathematical model of HR response using data collected from sheep subjects undergoing hemorrhage and fluid infusion. The model proved to be accurate in estimating the HR response to fluid perturbation, where averaged between 21 calibration datasets, the fitting performance showed a normalized root mean square error (NRMSE) of 7.41 ± 2.8%. The model was also evaluated in terms of model predictive capability performance via a leave-one-out procedure (21 subjects) and an independent validation dataset (6 subjects). Two different virtual cohort generation tools were used in each validation analysis. The generated envelope of virtual subjects robustly met the defined acceptance criteria, in which 95% of the testing datasets presented simulated HR patterns that were within a deviation of 50% from the observed data. In addition, out of 16000 and 18522 simulated subjects for the leave one-out and independent datasets, the model was able to generate at least one virtual subject that was close to the real subject within an error margin of 9.56 ± 3.15% and 11.1 ± 1.22% NRMSE, respectively. In conclusion, the model can generate valid virtual HR physiological responses to fluid perturbation and be incorporated into future non-clinical simulated testing setups for assessing PCLC devices intended for fluid resuscitation.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-50: Automatic Validation of Megavoltage Beams Modeled for Clinical Use in Radiation Therapy

Purpose: To automatically validate megavoltage beams modeled in XiO™ 4.50 (Elekta, Stockholm, Sweden) and Varian Eclipse™ Treatment Planning Systems (TPS) (Varian Associates, Palo Alto, CA, USA), reducing validation time before beam-on for clinical use. Methods: A software application that can automatically read and analyze DICOM RT Dose and W2CAD files was developed using MatLab integrated development environment.TPS calculated dose distributions, in DICOM RT Dose format, and dose values measured in different Varian Clinac beams, in W2CAD format, were compared. Experimental beam data used were those acquired for beam commissioning, collected on a water phantom with a 2D automatic beam scanning system.Two methods were chosen to evaluate dose distributions fitting: gamma analysis and point tests described in Appendix E of IAEA TECDOC-1583. Depth dose curves and beam profiles were evaluated for both open and wedged beams. Tolerance parameters chosen for gamma analysis are 3% and 3 mm dose and distance, respectively.Absolute dose was measured independently at points proposed in Appendix E of TECDOC-1583 to validate software results. Results: TPS calculated depth dose distributions agree with measured beam data under fixed precision values at all depths analyzed. Measured beam dose profiles match TPS calculated doses with high accuracy in both open and wedged beams. Depth and profile dose distributions fitting analysis show gamma values < 1. Relative errors at points proposed in Appendix E of TECDOC-1583 meet therein recommended tolerances.Independent absolute dose measurements at points proposed in Appendix E of TECDOC-1583 confirm software results. Conclusion: Automatic validation of megavoltage beams modeled for their use in the clinic was accomplished. The software tool developed proved efficient, giving users a convenient and reliable environment to decide whether to accept or not a beam model for clinical use. Validation time before beam-on for clinical use was reduced to a few hours.

60 APPLIED LIFE SCIENCES↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Radiation modeling and experimental validation of sub-cyclotron frequency microwave synchrotron radiation as a diagnostic tool for runaway electrons in present and future tokamaks

The microwave synchrotron radiation in the sub-cyclotron frequency region has been systematically validated as a diagnostic method for runaway electrons (>1 MeV) with radiation modeling and experiments on the DIII-D tokamak. Experimental observations reveal that sub-cyclotron frequency microwave radiation emerges only after runaway electrons are excited during plasma disruptions. Electron gyro-magnetic radiation modeling confirms that only runaway electrons with energies exceeding 1 MeV can emit radiation in the observed sub-cyclotron frequency band on DIII-D. The synchrotron Razin and Beaming effects are modeled in both the sub-cyclotron and standard Electron Cyclotron Emission (ECE) frequency region. Due to the pronounced beaming effect, the modeling supports that a standard ECE system is insensitive to synchrotron radiation from beamed runaway electrons (p ∥ >> p ⟂ ), but very sensitive to ECE radiation from isotropic suprathermal electrons (100 keV or less). DIII-D experiments further show that combining ECE and sub-cyclotron receivers reveals new insights into transient runaway dynamics during the plateau phase. Certain transient crash events appear only in the sub-cyclotron band or lead to opposite changes on the sub-cyclotron and standard ECE signals, supporting models where transient MHD events can exert a different effect on electrons of different energy levels. This novel diagnostic technique offers a powerful tool for studying and detecting runaway electron dynamics in both present-day and high-field future tokamaks. The diagnostic approach has been extrapolated to the SPARC tokamak, where sub-cyclotron radiation is predicted to respond sensitively and solely to runaway electrons during SPARC’s L-mode startup phase.

Yu, Guanying [Hefei Comprehensive National Science↗

Development and Validation of MALAMUTE model for Electric Field Assisted Sintering of Structural Materials

Fusion power plant designs feature extreme material performance requirements for structural material candidates. In addition to conventional alloys, more advanced composites and oxide dispersion strengthened (ODS) alloys are being explored, however, achieving the desired microstructures to maximize performance using traditional manufacturing methods can be challenging. The advanced manufacturing (AM) electric field-assisted sintering (EFAS) technique offers improved control over the final microstructure through higher heating and cooling rates and moderate pressures. Modeling and simulation tools show promise in elucidating the process-structure-property-performance (PSPP) correlation for AM-produced parts, including the EFAS process. An inherently multiscale process, the EFAS technique aligns well with the multiscale modeling capability of the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE)[cite]. We present here an electro-thermo-mechanical approach to modeling the EFAS process using the MOOSE Application Library for Advanced Manufacturing UTilitiEs (MALAMUTE) code. Prediction of the field and gradient distributions across the EFAS tooling is required to accurately describe the conditions for the lower-scale microstructural evolution models. In this work we present the MALAMUTE model developed to predict the electrical potential, temperature, and mechanical stress distribution across the EFAS graphite tooling and part at the larger engineering-scale. Validation of the MALAMUTE engineering-scale model is completed using data from experimental densification and pre-densified runs of iron powder via EFAS at 1000oC. These runs were conducted using a Thermal Technology DCS-5 EFAS system. Data collected during the experiment runs include the direct current (DC) supplied to the graphite tooling, the temperature of the graphite tooling as measured with a pyrometer, and the force applied to the top of the graphite tooling stack, and the data were recorded every 10 seconds. Our validation approach used the current and force data from the EFAS run as boundary condition inputs to the MAMALUTE simulation; the temperature data were used to evaluate the MALAMUTE EFAS model prediction. Results of the MALAMUTE simulations are employed to connect the external pyrometer temperature measurement to the temperature profile across the part undergoing consolidation. We investigate the impact of material property variation and mesh deformation on the temperature profile as predicted by MALAMUTE. We conclude by highlighting projects where the MALAMUTE EFAS modeling and simulation capabilities will be used to assist experimental design.

36 - MATERIALS SCIENCE↗

A framework for feasibility-level validation of high-resolution wave hindcast models

The value of long-term wave hindcasts for investigating wave climates, wave energy resources, and extreme wave conditions has motivated research developing, calibrating and validating wave hindcast models. Past hindcast model validation studies examined the accuracy in modeling bulk wave parameters of overall sea states without considering the dependency of the model's skill within different sea states. In the present study, a framework for wave hindcast model validation is developed by examining the model accuracy for the most frequently occurring sea states, sea states contributing the most energy to total wave power, sea states associated with hurricane events, and those with the largest model error. Here, validations using bulk wave parameters and frequency-directional spectra at these key sea states and extreme wave conditions based on univariate and bivariate-contour methods provide insights to improve model accuracy, identifying the model's strong and weak points, and pathways for improvement, e.g., modeling wave-current interactions and adjusting wind data. This study adds to a growing body of research demonstrating that a carefully calibrated and verified spectral wave hindcast model can be used to estimate key wave energy parameters over a wide range of wave energy climates, as well as their spatial, temporal, frequency, directional, and probabilistic distributions.

54 ENVIRONMENTAL SCIENCES↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of mathematical models for the prediction of organs-at-risk dosimetric metrics in high-dose-rate gynecologic interstitial brachytherapy

Purpose: Given the complicated nature of an interstitial gynecologic brachytherapy treatment plan, the use of a quantitative tool to evaluate the quality of the achieved metrics compared to clinical practice would be advantageous. For this purpose, predictive mathematical models to predict the D{sub 2cc} of rectum and bladder in interstitial gynecologic brachytherapy are discussed and validated.Methods: Previous plans were used to establish the relationship between D2cc and the overlapping volume of the organ at risk with the targeted area (C0) or a 1-cm expansion of the target area (C1). Three mathematical models were evaluated: D{sub 2cc}=α*C{sub 1}+β (LIN); D{sub 2cc}=α– exp(–β*C{sub 0}) (EXP); and a mixed approach (MIX), where both C{sub 0} and C{sub 1} were inputs of the model. The parameters of the models were optimized on a training set of patient data, and the predictive error of each model (predicted D{sub 2cc}− real D{sub 2cc}) was calculated on a validation set of patient data. The data of 20 patients were used to perform a K-fold cross validation analysis, with K = 2, 4, 6, 8, 10, and 20.Results: MIX was associated with the smallest mean prediction error <6.4% for an 18-patient training set; LIN had an error <8.5%; EXP had an error <8.3%. Best case scenario analysis shows that an error ≤5% can be achieved for a ten-patient training set with MIX, an error ≤7.4% for LIN, and an error ≤6.9% for EXP. The error decreases with the increase in training set size, with the most marked decrease observed for MIX.Conclusions: The MIX model can predict the D{sub 2cc} of the organs at risk with an error lower than 5% with a training set of ten patients or greater. The model can be used in the development of quality assurance tools to identify treatment plans with suboptimal sparing of the organs at risk. It can also be used to improve preplanning and in the development of real-time intraoperative planning tools.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and Validation of Numerical Models for Evaluation of Foam-Vacuum Insulation Panel Composite Boards, Including Edge Effects

A combined finite element analysis (FEA) and experimental validation approach to estimating effective edge conductivities of vacuum insulation panels (VIPs) embedded in foam-VIP composites is presented. The edge conductivities were estimated by comparing the simulation results with measurements of small-scale (0.61 × 0.61 m) foam-VIP composites and using an error minimization method. The two composites contained multiple VIPs that were butt-jointed with each other in one composite and separated by foam insulation in the other. Edge conductivities were estimated by considering the neighboring materials, i.e., whether the VIPs were adjacent to other VIPs or foam insulation. Models incorporating the edge conductivities were then used to simulate additional small- and large-scale (2.44 × 1.22 m) composites for validation and evaluation of the overall thermal transmission properties. The simulations used either the same boundary conditions as the experiments or used the experimental parameters to define the appropriate boundary conditions.

36 MATERIALS SCIENCE↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

A Bayesian framework for adaptive selection, calibration, and validation of coarse-grained models of atomistic systems

A general adaptive modeling algorithm for selection and validation of coarse-grained models of atomistic systems is presented. A Bayesian framework is developed to address uncertainties in parameters, data, and model selection. Algorithms for computing output sensitivities to parameter variances, model evidence and posterior model plausibilities for given data, and for computing what are referred to as Occam Categories in reference to a rough measure of model simplicity, make up components of the overall approach. Computational results are provided for representative applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗