Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Investigation of Imaging Spent Nuclear Fuel Dry Casks using Cosmic Ray Muons

Recently, the use of cosmic ray muons for cargo scanning applications has been demonstrated and muons have been shown to have the potential to allow for nondestructive assessment of nuclear material accountancy. Relativistic muons have the ability to penetrate dense materials and monitoring the subsequent scattering of muons can provide information about the structure and composition of materials stored in cargo containers. The suitability of cosmic muons for a number of monitoring and imaging applications has been investigated over the years and includes applications to archaeology, volcano imaging, material identification and medical diagnosis. Novel applications of cosmic ray muons have been proposed for examination of comatose patients towards bone density monitoring and also for determination of the molten nuclear fuel location in nuclear reactors having suffered from the effects of a severe accident similar to the one happened in Fukushima. There is a need to develop a capability to monitor nuclear waste and investigate whether the stored content agrees with facility declarations to allow proliferation detection and international treaty verification. Monitoring nuclear waste and controlling nuclear material at its source is one of the main strategies to minimize the risks of nuclear proliferation and reduce potential homeland threats. Since the early 1950's, when the first nuclear power plant began to produce electricity, approximately 65,000 metric tons of spent nuclear fuel have been generated, 25% of which are under dry storage conditions. After the spent nuclear fuel has been placed inside the dry cask, the cask is welded, not allowing for visual inspection. During the long storage life of the cask, intermediate handling and transportation activities take place which does create concerns regarding fuel integrity. Accidents and natural disasters also contribute to this concern. Previous work on spent nuclear fuel dry cask monitoring using muons has shown that the muon scattering distributions are adequately separated and a and a decision rule derived from Bayes' Theorem rendering the classification of different dry casks feasible. Muons present significant advantages over the existing imaging techniques such as the utilization of the passive nature of muons, the lack of radiological sources and consequently the absence of any artificial radiological dose. In the present work, a methodology is developed to demonstrate the applicability of muons for imaging of spent nuclear fuel dry casks. Purpose is to use muons to differentiate between spent nuclear fuel dry casks with different amounts of loading. Monte Carlo simulations of dry casks with different spent nuclear fuel loading are performed to simulate the passage of polyenergetic muons having energies in the range of 1-60 GeV through matter. A 'Muon Generator' is developed to generate muons that follow the actual sea level energy distribution. The 'Muon Generator' is validated against a series of actual spectrum measurements and then coupled with the Monte Carlo particle transport code GEANT4. The accumulated dataset of scattering angles were processed with the Point-of- the-Closest-Approach (PoCA) imaging algorithm and the obtained images demonstrate that an empty dry cask can be clearly distinguished from a half-loaded or a fully loaded one. The apparent separation of the images demonstrates that the muon scattering can be used as a feature for imaging spent nuclear fuel dry casks. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-81: Comparison of Microdosimetric Quantities Calculated Using the Track Structure Monte Carlo Algorithms Geant4-DNA and NOREC

Purpose: Microdosimetric quantities, such as the lineal energy, have been shown to correlate with the biological response to radiation and the relative biological effect of different radiation types. Track-structure Monte Carlo simulations are an important tool for investigating these responses and for developing mechanistic models to explain them. However, some of the cross-sectional data used in these algorithms has large uncertainties; thus, it is important to investigate how the implementation of the different codes affects the quantities of interest. Methods: Two of the most widely-used publicly available track-structure Monte Carlo codes, Geant4-DNA and NOREC, were used generate electron tracks for two particle sources. One source was a mono-energetic parallel beam of electrons with energies from 5 to 500-keV, and the lineal energy for each track was calculated in 1-mm-spheres arranged in planar arrays at multiple distances from the source. The second source was mono-energetic, uniformly-distributed, and isotropic source, and the lineal energy was scored in a single 30-mm-sphere for energies between 300-eV and 5-keV. Results: The dose-mean lineal energy for the parallel-beam simulations almost all agreed within 5%. For the uniformly-distributed source, at the lowest energies there was strong agreement between the algorithms, but the Geant4-DNA simulations showed slightly more high-energy events for more energetic electrons, but the dose-mean lineal energy agreed to within 4% for all energies. Conclusion: While there were slight differences in the results between the codes, these were consistent with previous studies of the stopping power and angular scattering distributions. Importantly, the computation time for Geant4-DNA was larger than for NOREC, largely due to approximations used in the NOREC for energies below 10-eV. This study shows that these approximation does not have a major impact on the microdosimetry on the energy and length scales investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron production in the beryllium filter of a linac using 6 MeV treatment beam - 25425

In most conventional radiation therapy treatments, special attention is paid for neutron contamination when working with energy beams above 8 MeV. Generally, neutron generation it is only considered for shielding requirements, not for dose study in patients or employees. The present work is focused on studying the unwanted generated photoneutrons in a Medical Linear Accelerator (Linac) Varian TrueBeam using a 6 MeV radiation treatment beam. To that, Monte Carlo (MC) simulation code MCNP6.1.1 was used. This new version of the code allows the use of unstructured mesh geometries models, offering more geometric reliable results. The particularity of the studied Linac is the presence of a beryllium filter at the treatment head. Since Beryllium causes photonuclear reactions (γ, n) at energies much lower than other Linac composing materials, this work aims to analyze if this type of unit, when using low energy treatment beams (6 MeV), produce significant neutron dose and to ensure that this unwanted radiation can be considered negligible. (authors)

43 PARTICLE ACCELERATORS↗

Development of CSG-based radiation shielding module for ARCHER: preliminary results for photons - Paper 126

ARCHER is a parallel Monte Carlo radiation transport code being developed for various hardware platforms including multi-core CPUs, the emerging Nvidia graphics processing units (GPUs) and Intel Xeon Phi coprocessors. Previous studies have demonstrated the accuracy and speed for CT imaging and radiotherapy dosimetry applications. Radiation shielding applications, however, require ARCHER to be more flexible in defining and handling geometries, in addition to the voxel phantom geometries that are commonly used in medical physics calculations. In this paper, we present the development of a general geometry module used for radiation protection and shielding problems in ARCHER. The methods of geometry design and particle transport for the GPUs are introduced. Preliminary results comparing against the MCNP code for cases involving Cs-137 0.662 MeV gammas are reported. The radiation shielding design module of ARCHER has been developed, which supports general geometry setups in the CSG format. The code was implemented using CUDA on Nvidia GPUs, and the performance was benchmarked against the MCNP code for a simple radiation shielding problem. Results showed that ARCHER worked properly and achieved impressive speedup due to highly parallel computing nature of the Nvidia GPUs compared to the MCNP code running on multi-core CPUs. Further optimization of the geometry module will be carried out using advanced geometry structures and variance reduction techniques to improve the precision and performance of ARCHER. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of the hard x-ray background in backlit pinhole imagers

Hard x-rays from laser-produced hot electrons (>10 keV) in backlit pinhole imagers can give rise to a background signal that decreases signal dynamic range in radiographs. Consequently, significant uncertainties are introduced to the measured optical depth of imaged plasmas. Past experiments have demonstrated that hard x-rays are produced when hot electrons interact with the high-Z pinhole substrate used to collimate the softer He-α x-ray source. Results are presented from recent experiments performed on the OMEGA-60 laser to further study the production of hard x-rays in the pinhole substrate and how these x-rays contribute to the background signal in radiographs. Radiographic image plates measured hard x-rays from pinhole imagers with Mo, Sn, and Ta pinhole substrates. The variation in background signal between pinhole substrates provides evidence that much of this background comes from x-rays produced in the pinhole substrate itself. A Monte Carlo electron transport code was used to model x-ray production from hot electrons interacting in the pinhole substrate, as well as to model measurements of x-rays from the irradiated side of the targets, recorded by a bremsstrahlung x-ray spectrometer. Inconsistencies in inferred hot electron distributions between the different pinhole substrate materials demonstrate that additional sources of hot electrons beyond those modeled may produce hard x-rays in the pinhole substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations

Purpose: To develop a computed tomography (CT) organ dose estimation method designed to readily provide organ doses in a reference adult male and female for different scan ranges to investigate the degree to which existing commercial programs can reasonably match organ doses defined in these more anatomically realistic adult hybrid phantomsMethods: The x-ray fan beam in the SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code MCNPX2.6. The simulated CT scanner model was validated through comparison with experimentally measured lateral free-in-air dose profiles and computed tomography dose index (CTDI) values. The reference adult male and female hybrid phantoms were coupled with the established CT scanner model following arm removal to simulate clinical head and other body region scans. A set of organ dose matrices were calculated for a series of consecutive axial scans ranging from the top of the head to the bottom of the phantoms with a beam thickness of 10 mm and the tube potentials of 80, 100, and 120 kVp. The organ doses for head, chest, and abdomen/pelvis examinations were calculated based on the organ dose matrices and compared to those obtained from two commercial programs, CT-EXPO and CTDOSIMETRY. Organ dose calculations were repeated for an adult stylized phantom by using the same simulation method used for the adult hybrid phantom. Results: Comparisons of both lateral free-in-air dose profiles and CTDI values through experimental measurement with the Monte Carlo simulations showed good agreement to within 9%. Organ doses for head, chest, and abdomen/pelvis scans reported in the commercial programs exceeded those from the Monte Carlo calculations in both the hybrid and stylized phantoms in this study, sometimes by orders of magnitude. Conclusions: The organ dose estimation method and dose matrices established in this study readily provides organ doses for a reference adult male and female for different CT scan ranges and technical parameters. Organ doses from existing commercial programs do not reasonably match organ doses calculated for the hybrid phantoms due to differences in phantom anatomy, as well as differences in organ dose scaling parameters. The organ dose matrices developed in this study will be extended to cover different technical parameters, CT scanner models, and various age groups.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of realistic Monte Carlo plasma gamma-ray source on JET discharges

A novel modelling methodology has been developed for the creation of a realistic plasma gamma-ray source for Monte Carlo transport simulations in the tokamak JET. The methodology couples the TRANSP code for plasma transport calculations with the MCNP Monte Carlo particle transport code, thus connecting plasma physics with gamma-ray transport. Here, we present the validation of the developed source methodology by comparing calculated gamma-ray spectra with measurements performed at JET. The validation focuses on gamma-ray spectra measured by the tangential gamma-ray spectrometer during two JET three ion RF scenario discharges, performed in the JET 2019 deuterium experimental campaign. For validation the calculated plasma gamma-ray spectrum was combined with the neutron induced prompt gamma-ray background, originating in the vacuum vessel, and scaled to absolute values calculating the total number of plasma gamma-ray and neutron emitting reactions. The comparison between calculated and measured gamma-ray spectra shows good agreement with the shape of the calculated gamma-ray spectra matching that of measurements for both studied discharges. Moreover, the calculated absolute values of the gamma-ray spectra were of the same order of magnitude at the position of the gamma-ray detector located at the end of a long line-of-sight in a biological shield. Finally, the comparison has validated the developed plasma gamma-ray source methodology for MCNP photon transport calculations at JET. The validation provides a basis for the developed plasma gamma-ray source to be used as a support for the development of future tokamaks such as DEMO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Point containment algorithms for constructive solid geometry with unbounded primitives

Here, we present several algorithms for evaluating point containment in constructive solid geometry (CSG) trees with unbounded primitives. Three algorithms are presented based on postfix, prefix, and infix notations of the CSG binary expression tree. We show that prefix and infix notations enable short-circuiting logic, which reduces the number of primitives that must be checked during point containment. To evaluate the performance of the algorithms, each algorithm was implemented in the OpenMC Monte Carlo particle transport code, which relies on CSG to represent solid bodies through which subatomic particles travel. Two sets of tests were carried out. First, the execution time to generate a rasterized image of a 2D slice of three CSG models of varying complexity was measured. Use of both prefix and infix notations offered significant speedup over the postfix notation that has traditionally been used in particle transport codes, with infix resulting in a 6 x reduction in execution time relative to postfix for a model of a tokamak fusion device. We then measured the execution time of neutron transport simulations of the same three models using each of the algorithms. The results and performance improvements reveal the same trends as for the rasterization test, with a 5.52 x overall speedup using the infix notation relative to the original postfix notation in OpenMC for the tokamak model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-D-16A-01: A Novel Method to Estimate Normal Tissue Dose for Radiotherapy Patients to Support Epidemiologic Studies of Second Cancer Risk

Purpose: Patient cohort of second cancer study often involves radiotherapy patients with no radiological images available: We developed methods to construct a realistic surrogate anatomy by using computational human phantoms. We tested this phantom images both in a commercial treatment planning system (Eclipse) and a custom Monte Carlo (MC) transport code. Methods: We used a reference adult male phantom defined by International Commission on Radiological Protection (ICRP). The hybrid phantom which was originally developed in Non-Uniform Rational B-Spline (NURBS) and polygon mesh format was converted into more common medical imaging format. Electron density was calculated from the material composition of the organs and tissues and then converted into DICOM format. The DICOM images were imported into the Eclipse system for treatment planning, and then the resulting DICOM-RT files were imported into the MC code for MC-based dose calculation. Normal tissue doses were calculation in Eclipse and MC code for an illustrative prostate treatment case and compared to each other. Results: DICOM images were generated from the adult male reference phantom. Densities and volumes of selected organs between the original phantom and ones represented within Eclipse showed good agreements, less than 0.6%. Mean dose from Eclipse and MC code match less than 7%, whereas maximum and minimum doses were different up to 45%. Conclusion: The methods established in this study will be useful for the reconstruction of organ dose to support epidemiological studies of second cancer in cancer survivors treated by radiotherapy. We also work on implementing body size-dependent computational phantoms to better represent patient's anatomy when the height and weight of patients are available.

60 APPLIED LIFE SCIENCES↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

MULTIDIMENSIONAL CHEMICAL MODELING OF YOUNG STELLAR OBJECTS. II. IRRADIATED OUTFLOW WALLS IN A HIGH-MASS STAR-FORMING REGION

Observations of the high-mass star-forming region AFGL 2591 reveal a large abundance of CO{sup +}, a molecule known to be enhanced by far-ultraviolet (FUV) and X-ray irradiation. In chemical models assuming a spherically symmetric envelope, the volume of gas irradiated by protostellar FUV radiation is very small due to the high extinction by dust. The abundance of CO{sup +} is thus underpredicted by orders of magnitude. In a more realistic model, FUV photons can escape through an outflow region and irradiate gas at the border to the envelope. Thus, we introduce the first two-dimensional axisymmetric chemical model of the envelope of a high-mass star-forming region to explain the CO{sup +} observations as a prototypical FUV tracer. The model assumes an axisymmetric power-law density structure with a cavity due to the outflow. The local FUV flux is calculated by a Monte Carlo radiative transfer code taking scattering on dust into account. A grid of precalculated chemical abundances, introduced in the first part of this series of papers, is used to quickly interpolate chemical abundances. This approach allows us to calculate the temperature structure of the FUV-heated outflow walls self-consistently with the chemistry. Synthetic maps of the line flux are calculated using a raytracer code. Single-dish and interferometric observations are simulated and the model results are compared to published and new JCMT and Submillimeter Array (SMA) observations. The two-dimensional model of AFGL 2591 is able to reproduce the JCMT single-dish observations and also explains the nondetection by the SMA. We conclude that the observed CO{sup +} line flux and its narrow width can be interpreted by emission from the warm and dense outflow walls irradiated by protostellar FUV radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Personal dose equivalent conversion coefficients for neutron fluence over the energy range of 20 to 250 MeV

Monte Carlo simulations were performed to extend existing neutron personal dose equivalent fluence-to-dose conversion coefficients to an energy of 250 MeV. Presently, conversion coefficients, H(p,slab)(10,alpha)/Phi, are given by ICRP-74 and ICRU-57 for a range of angles of radiation incidence (alpha = 0, 15, 30, 45, 60 and 75 degrees ) in the energy range from thermal to 20 MeV. Standard practice has been to base operational dose quantity calculations <20 MeV on the kerma approximation, which assumes that charged particle secondaries are locally deposited, or at least that charged particle equilibrium exists within the tally cell volume. However, with increasing neutron energy the kerma approximation may no longer be valid for some energetic secondaries such as protons. The Los Alamos Monte Carlo radiation transport code MCNPX was used for all absorbed dose calculations. Transport models and collision-based energy deposition tallies were used for neutron energies >20 MeV. Both light and heavy ions (HIs) (carbon, nitrogen and oxygen recoil nuclei) were transported down to a lower energy limit (1 keV for light ions and 5 MeV for HIs). Track energy below the limit was assumed to be locally deposited. For neutron tracks <20 MeV, kerma factors were used to obtain absorbed dose. Results are presented for a discrete set of angles of incidence on an ICRU tissue slab phantom.

61 RADIATION PROTECTION AND DOSIMETRY↗

A three-dimensional methodology for the assessment of neutron damage and nuclear energy deposition in graphite components of advanced gas-cooled reactors

This paper describes the development of a three-dimensional methodology for the assessment of neutron damage and nuclear energy deposition (or nuclear heating) throughout the graphite cores of the UK's Advanced Gas-cooled Reactors. Advances in the development of the Monte Carlo radiation transport code MCBEND have enabled the efficient production of detailed fully three-dimensional models that utilise three-dimensional source distributions obtained from Core Follow data supplied by the reactor physics code PANTHER. The calculational approach can be simplified to reduce both the requisite number of intensive radiation transport calculations, as well as the quantity of data output. These simplifications have been qualified by comparison with explicit calculations and they have been shown not to introduce significant systematic uncertainties. Simple calculational approaches are described that allow users of the data to address the effects on neutron damage and nuclear energy deposition predictions of the feedback resulting from the mutual dependencies of graphite weight loss and nuclear energy deposition. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

More accurate fitting of {sup 125}I and {sup 103}Pd radial dose functions

In this study an improved functional form for fitting the radial dose functions, g(r), of {sup 125}I and {sup 103}Pd brachytherapy seeds is presented. The new function is capable of accurately fitting radial dose functions over ranges as large as 0.05 cm{<=}r{<=}10 cm for {sup 125}I seeds and 0.10 cm{<=}r{<=}10 cm for {sup 103}Pd seeds. The average discrepancies between fit and calculated data are less than 0.5% over the full range of fit and maximum discrepancies are 2% or less. The fitting function is also capable of accounting for the sharp increase in g(r) (upturn) seen for some sources for r<0.1 cm. This upturn has previously been attributed to the breakdown of the approximation of the sources as a line, however, in this study we demonstrate that another contributing factor is the 4.5 keV characteristic x-rays emitted from the Ti seed casing. Radial dose functions are calculated for 18 {sup 125}I seeds and 9 {sup 103}Pd seeds using the EGSnrc Monte Carlo user-code BrachyDose. Fitting coefficients of the new function are tabulated for all 27 seeds. Extrapolation characteristics of the function are also investigated. The new functional form is an improvement over currently used fitting functions with its main strength being the ability to accurately fit the rapidly varying radial dose function at small distances. The new function is an excellent candidate for fitting the radial dose function of all {sup 103}Pd and {sup 125}I brachytherapy seeds and will increase the accuracy of dose distributions calculated around brachytherapy seeds using the TG-43 protocol over a wider range of data. More accurate values of g(r) for r<0.5 cm may be particularly important in the treatment of ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines

A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STRUCTURE AND COMPOSITION OF TWO TRANSITIONAL CIRCUMSTELLAR DISKS IN CORONA AUSTRALIS

The late stages of evolution of the primordial circumstellar disks surrounding young stars are poorly understood, yet vital to constraining theories of planet formation. We consider basic structural models for the disks around two {approx}10 Myr old members of the nearby RCrA association: RX J1842.9-3532 and RX J1852.3-3700. We present new arcsecond-resolution maps of their 230 GHz continuum emission from the Submillimeter Array and unresolved CO(3-2) spectra from the Atacama Submillimeter Telescope Experiment. By combining these data with broadband fluxes from the literature and infrared fluxes and spectra from the catalog of the Formation and Evolution of Planetary Systems Legacy program on the Spitzer Space Telescope, we assemble a multiwavelength data set probing the gas and dust disks. Using the Monte Carlo radiative transfer code RADMC to model simultaneously the spectral energy distribution and millimeter continuum visibilities, we derive basic dust disk properties and identify an inner cavity of radius 16 AU in the disk around RX J1852.3-3700. We also identify an optically thin 5 AU cavity in the disk around RX J1842.9-3532, with a small amount of optically thick material close to the star. The molecular line observations suggest an intermediate disk inclination in RX J1842.9-3532, consistent with the continuum emission. In combination with the dust models, the molecular data allow us to derive a lower CO content than expected, suggesting that the process of gas clearing is likely underway in both systems, perhaps simultaneously with planet formation.

79 ASTRONOMY AND ASTROPHYSICS↗

A Study on Reconstruction of Intra-Pin Information in Pin-Wise Reactor Analysis

Along with nodal calculation, accurate pin-wise calculations with parallel computational platforms have been recently developed as alternative tools to nodal methods to maximize core performance and minimize uncertainties used in reactor safety analysis. Therefore, it is necessary to have a method for accurately reconstructing intra-pin information comparable to whole-core transport calculation while being significantly more computationally efficient. In this study, a method to reconstruct intra-pin information (intra-pin reconstruction) is proposed. This method is based on combining the local intra-pin form function with the global homogeneous distribution. The form functions are generated from a single pin calculation with reflective boundary conditions using Serpent 2, a Monte Carlo neutron transport code. The global homogeneous flux was reconstructed using the analytical solution of the diffusion equation due to its superior accuracy and speed compared to other methods. The study here is limited to a two-dimensional two-group problem of rectangular geometric fuel pin element. The pin-wise boundary constraints (BCs) and reference intra-pin power used for reconstruction and comparison were obtained from the Serpent 2 reference calculation. From our study, it is indicated that maximum relative error (MRE) between reconstructed and reference values is within 5%. In addition, a sensitivity study was also performed to assess the feasibility of the method when the proposed method is coupled with a pin-wise calculation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗