Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Comparison of GiBUU calculations with MiniBooNE pion production data

Background: Neutrino-induced pion production can give important informationon the axial coupling to nucleon resonances. Furthermore, pion production represents a major background to quasielastic-like events. one pion production data from the MiniBooNE in charged current neutrino scattering in mineral oil appeared higher than expected within conventional theoretical approaches. Purpose: We aim to investigate which model parameters affect the calculated cross section and how they do this. Method: The Giessen Boltzmann–Uehling–Uhlenbeck (GiBUU) model is used for an investigation of neutrino-nucleus reactions. Results: Presented are integrated and differential cross sections for 1π{sup +} and 1π{sup 0} production before and after final state interactions in comparison with the MiniBooNE data. Conclusions: For the MiniBooNE flux all processes (QE, 1π-background, Δ, higher resonance production, DIS) contribute to the observed final state with one pion of a given charge. The uncertainty in elementary pion production cross sections leads to a corresponding uncertainty in the nuclear cross sections. Final state interactions change the shape of the muon-related observables only slightly, but they significantly change the shape of pion distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intercomparison of Commercially Available Active Radon Measurement Devices in a Discovered Radon Chamber

An unventilated 70 m 3 underground space, with 2.1 m high ceilings and an inner set of concrete walls to damp vibrations, was discovered to have relatively stable radon levels of ~1,080 Bq m -3 over a 1-y period. The addition of radium sources was not required to achieve high and somewhat variable radon levels, as these arise naturally in the space. Several active radon monitoring devices designed for homeowners, radon screeners, radon mitigation professionals, and researchers were tested in the space. These devices were variable in both cost and intended user sophistication. Data were collected at specific time intervals that varied for each device. A cellphone was deployed with an available camera application to periodically capture photographs of the displays of devices not enabled for automatic temporal recording. Attempts were made to alter the radon concentration using fans, radium-laden objects, and radon impermeable sheets. Statistical methods were employed to compare the device's performance under the minor radon transients produced by the addition of 226 Ra sources during the test period. The evaluation of the overall accuracy, noise, and response to transients revealed highly affordable devices that may be useful for future research applications.While unsuitable for precise calibrations at stable radon levels, the space was determined to be adequate as a radon chamber for general research purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

29 th International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities (Project Summary)

Sandia National Laboratories (Sandia) has hosted the International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities since 1978. This course is the flagship training course of the International Atomic Energy Agency (IAEA). On behalf of the National Nuclear Security Administration (NNSA), Sandia manages, develops, and coordinates all course materials, and works closely with the IAEA to arrange all logistical details for the course ITC-29 incorporated some updates to the facility models, based on feedback received in ITC-28 and the ITC-29 dry run. In addition, all the graphics were refreshed after ITC-28 and implemented in the posters, data handbooks, etc. As in ITC-28, the ITC-29 staff worked closely with the IAEA on course materials, including a peer review process to ensure all course materials were aligned with Nuclear Security Series No. 13 and other relevant international guidance documentation from the IAEA. Due to the COVID-19 pandemic, ITC-29 was postponed twice and eventually took place in the late summer/early fall of 2022. Due to ongoing COVID-19 restrictions and safety requirements, the number of participants was reduced by about 31 percent from 59 participants in ITC-28 to 41 in ITC-29. As a result, the number of subgroups also decreased from eight in ITC-28 to six for ITC-29. This enabled the Sandia team to implement more opportunities for social distancing, particularly in the large classrooms. Despite the challenges, ITC-29 still passed a significant milestone, with the one-thousandth participant of the international training course attending during this event. Finally, the ITC staff continued the use of its improved method of evaluation to capture participants’ satisfaction with the updated course and to gather feedback concerning future improvements. This document provides a brief description of ITC-29, including a summary of lessons learned and key recommendations for future development efforts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Portal dosimetry for VMAT using integrated images obtained during treatment

Purpose: Portal dosimetry provides an accurate and convenient means of verifying dose delivered to the patient. A simple method for carrying out portal dosimetry for volumetric modulated arc therapy (VMAT) is described, together with phantom measurements demonstrating the validity of the approach. Methods: Portal images were predicted by projecting dose in the isocentric plane through to the portal image plane, with exponential attenuation and convolution with a double-Gaussian scatter function. Appropriate parameters for the projection were selected by fitting the calculation model to portal images measured on an iViewGT portal imager (Elekta AB, Stockholm, Sweden) for a variety of phantom thicknesses and field sizes. This model was then used to predict the portal image resulting from each control point of a VMAT arc. Finally, all these control point images were summed to predict the overall integrated portal image for the whole arc. The calculated and measured integrated portal images were compared for three lung and three esophagus plans delivered to a thorax phantom, and three prostate plans delivered to a homogeneous phantom, using a gamma index for 3% and 3 mm. A 0.6 cm{sup 3} ionization chamber was used to verify the planned isocentric dose. The sensitivity of this method to errors in monitor units, field shaping, gantry angle, and phantom position was also evaluated by means of computer simulations. Results: The calculation model for portal dose prediction was able to accurately compute the portal images due to simple square fields delivered to solid water phantoms. The integrated images of VMAT treatments delivered to phantoms were also correctly predicted by the method. The proportion of the images with a gamma index of less than unity was 93.7% ± 3.0% (1SD) and the difference between isocenter dose calculated by the planning system and measured by the ionization chamber was 0.8% ± 1.0%. The method was highly sensitive to errors in monitor units and field shape, but less sensitive to errors in gantry angle or phantom position. Conclusions: This method of predicting integrated portal images provides a convenient means of verifying dose delivered using VMAT, with minimal image acquisition and data processing requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compartment modeling of dynamic brain PET—The impact of scatter corrections on parameter errors

Purpose: The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. Methods: The GATE Monte Carlo (MC) software was used to perform 2 × 15 full PET scan simulations of a voxelized head phantom with inserted tumor regions. The two sets of kinetic parameters of all tissues were chosen to represent the 2-tissue compartment model for the tracer 3′-deoxy-3′-({sup 18}F)fluorothymidine (FLT), and were denoted FLT{sub 1} and FLT{sub 2}. PET data were reconstructed with both 3D filtered back-projection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM). Images including true coincidences with attenuation correction (AC) and true+scattered coincidences with AC and with and without one of two applied SC schemes were reconstructed. Kinetic parameters were estimated by weighted nonlinear least squares fitting of image derived time–activity curves. Calculated parameters were compared to the true input to the MC simulations. Results: The relative parameter biases for scatter-eliminated data were 15%, 16%, 4%, 30%, 9%, and 7% (FLT{sub 1}) and 13%, 6%, 1%, 46%, 12%, and 8% (FLT{sub 2}) for K{sub 1}, k{sub 2}, k{sub 3}, k{sub 4}, V{sub a}, and K{sub i}, respectively. As expected, SC was essential for most parameters since omitting it increased biases by 10 percentage points on average. SC was not found necessary for the estimation of K{sub i} and k{sub 3}, however. There was no significant difference in parameter biases between the two investigated SC schemes or from parameter biases from scatter-eliminated PET data. Furthermore, neither 3DRP nor OSEM yielded the smallest parameter biases consistently although there was a slight favor for 3DRP which produced less biased k{sub 3} and K{sub i} estimates while OSEM resulted in a less biased V{sub a}. The uncertainty in OSEM parameters was about 26% (FLT{sub 1}) and 12% (FLT{sub 2}) larger than for 3DRP although identical postfilters were applied. Conclusions: SC was important for good parameter estimations. Both investigated SC schemes performed equally well on average and properly corrected for the scattered radiation, without introducing further bias. Furthermore, 3DRP was slightly favorable over OSEM in terms of kinetic parameter biases and SDs.

60 APPLIED LIFE SCIENCES↗

Computation of a Canadian SCWR unit cell with deterministic and Monte Carlo codes

The Canadian SCWR has the potential to achieve the goals that the generation IV nuclear reactors must meet. As part of the optimization process for this design concept, lattice cell calculations are routinely performed using deterministic codes. In this study, the first step (self-shielding treatment) of the computation scheme developed with the deterministic code DRAGON for the Canadian SCWR has been validated. Some options available in the module responsible for the resonance self-shielding calculation in DRAGON 3.06 and different microscopic cross section libraries based on the ENDF/B-VII.0 evaluated nuclear data file have been tested and compared to a reference calculation performed with the Monte Carlo code SERPENT under the same conditions. Compared to SERPENT, DRAGON underestimates the infinite multiplication factor in all cases. In general, the original Stammler model with the Livolant-Jeanpierre approximations are the most appropriate self-shielding options to use in this case of study. In addition, the 89 groups WIMS-AECL library for slight enriched uranium and the 172 groups WLUP library for a mixture of plutonium and thorium give the most consistent results with those of SERPENT. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Life cycle assessment and residue leaching: The importance of parameter, scenario and leaching data selection

Highlights: • Relevance of metal leaching in waste management system LCAs was assessed. • Toxic impacts from leaching could not be disregarded. • Uncertainty of toxicity, due to background activities, determines LCA outcomes. • Parameters such as pH and L/S affect LCA results. • Data modelling consistency and coverage within an LCA are crucial. - Abstract: Residues from industrial processes and waste management systems (WMSs) have been increasingly reutilised, leading to landfilling rate reductions and the optimisation of mineral resource utilisation in society. Life cycle assessment (LCA) is a holistic methodology allowing for the analysis of systems and products and can be applied to waste management systems to identify environmental benefits and critical aspects thereof. From an LCA perspective, residue utilisation provides benefits such as avoiding the production and depletion of primary materials, but it can lead to environmental burdens, due to the potential leaching of toxic substances. In waste LCA studies where residue utilisation is included, leaching has generally been neglected. In this study, municipal solid waste incineration bottom ash (MSWI BA) was used as a case study into three LCA scenarios having different system boundaries. The importance of data quality and parameter selection in the overall LCA results was evaluated, and an innovative method to assess metal transport into the environment was applied, in order to determine emissions to the soil and water compartments for use in an LCA. It was found that toxic impacts as a result of leaching were dominant in systems including only MSWI BA utilisation, while leaching appeared negligible in larger scenarios including the entire waste system. However, leaching could not be disregarded a priori, due to large uncertainties characterising other activities in the scenario (e.g. electricity production). Based on the analysis of relevant parameters relative to leaching, and on general results of the study, recommendations are provided regarding the use of leaching data in LCA studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Development of Variable Design Lifetimes and Creep-Fatigue Evaluations for ASME Section III, Division 5, Class B Code Rules

This report summarizes the initial development of new ASME Section III, Division 5, Class B rules to address the gaps identified for new high temperature reactor designs. The overall objective is to introduce the design-by-analysis approach, the variable design lifetimes for primary load design, and the strain limits and creep-fatigue damage evaluations for Class B components. It is also desired that the new evaluation procedures do not require stress classification and stress linearization. Further, the data requirements to support the development of design parameters for the new Class B rules would not be overly burdensome, and less extensive than those supporting Class A rules. We have identified the Elastic, Perfectly Plastic (EPP) method as the design by-analysis approach for primary load design, and developed allowable stress criteria for variable design lifetimes, up to 500,000 hours, that only require data typical for the allowable stresses in Section II, Part D, Tables 1A and 1B. We have also adapted the elastic analysis approach from HBB-T-1400 and Section III, Mandatory Appendix XIII, XIII-2400 and XIII-3520(e) for the new Class B creep-fatigue evaluation procedure. A new elastic follow-up-based Isochronous Stress Strain Curve (ISSC) stress relaxation procedure has been developed to provide adequate conservatism commensurate with Class B constructions. No stress classification and stress linearization are required in the new procedure. Future work needed to complete the development is also summarized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Correlated Trajectory Uncertainty for Adaptive Sequential Decision Making

One of the great challenges with decision making tasks on real world systems is the fact that data is sparse and acquiring additional data is expensive. In these cases, it is often crucial to make a model of the environment to assist in making decisions. At the same time, limited data means that learned models are erroneous, making it just as important to equip the model with good predictive uncertainties. In the context of learning sequential decision making policies, these uncertainties can prove useful for informing which data to collect for the greatest improvement in policy performance \citep{mehta2021experimental, mehta2022exploration} or informing the policy about unsure regions of state and action space to avoid during test time \citep{yu2020mopo}. Additionally, assuming that realistic samples of the environment can be drawn, an adaptable policy can be trained that attempts to make optimal decisions for any given possible instance of the environment \citep{ghosh2022offline, chen2021offline}. In this work, we examine the so-called ``probabilistic neural network'' (PNN) model that is ubiquitous in model-based reinforcement learning (MBRL) works. We argue that while PNN models may have good marginal uncertainties, they form a distribution of non-smooth transition functions. Not only are these samples unrealistic and may hamper adaptability, but we also assert that this leads to poor uncertainty estimates when predicting multiple step trajectory estimates. To address this issue, we propose a simple sampling method that can be implemented on top of pre-existing models.We evaluate our sampling technique on a number of environments, including a realistic nuclear fusion task, and find that, not only do smooth transition function samples produce more calibrated uncertainties, but they also lead to better downstream performance for an adaptive policy.

Offline Reinforcement Learning↗

Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods

The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Method to Extract the Charge Distribution Arriving at the TPC Wire Planes in MicroBooNE

In this technote, we describe the concept and general strategy of LArTPC drifted-charge extraction, which converts the raw digitized TPC waveform to the number of ionized electrons passing through the wire plane at a given time. The proper recovery of the number of ionized electrons from all wire planes is important to the success of the subsequent reconstruction algorithms. A number of building blocks for the processing algorithm are described and characterized. An example of implementation of the algorithm was realized inside the Wire-Cell reconstruction package. The performance was qualitatively illustrated on MicroBooNE data with event display pictures, which shows significant improvements. Some metrics to evaluate the performance of the TPC signal extraction procedure are described. Next steps towards the quantification of the effect of the proposed concept and optimization of the procedure are outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Neutron Scattering Law (TNSL) Implementation and Testing in FUDGE

Thermal neutron scattering law processing capabilities have been recently implemented in the LLNL code FUDGE (For Updating Data and Generating Evaluations). FUDGE is now capable of producing processed TNSL data for use in Monte Carlo or deterministic transport. To test this new capability, LLNL scientists performed an extensive intercomparison between the Mercury, Ardra, COG and MCNP transport codes. This intercomparison helped probe differences between how TNSL data are handled by the transport codes and by two different processing codes (LLNL’s FUDGE and LANL’s NJOY). This report summarizes recent improvements in FUDGE TNSL capabilities as well as results from the code intercomparison.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty quantification for Multiphase-CFD simulations of bubbly flows: a machine learning-based Bayesian approach supported by high-resolution experiments

In this paper, we developed a machine learning-based Bayesian approach to inversely quantify and reduce the uncertainties of multiphase computational fluid dynamics (MCFD) simulations for bubbly flows. The proposed approach is supported by high-resolution two-phase flow measurements, including those by double-sensor conductivity probes, high-speed imaging, and particle image velocimetry. Local distributions of key physical quantities of interest (QoIs), including the void fraction and phasic velocities, are obtained to support the Bayesian inference. In the process, the epistemic uncertainties of the closure relations are inversely quantified while the aleatory uncertainties from stochastic fluctuations of the system are evaluated based on experimental uncertainty analysis. The combined uncertainties are then propagated through the MCFD solver to obtain uncertainties of the QoIs, based on which probability-boxes are constructed for validation. The proposed approach relies on three machine learning methods: feedforward neural networks and principal component analysis for surrogate modeling, and Gaussian processes for model form uncertainty modeling. The whole process is implemented within the framework of an open-source deep learning library PyTorch with graphics processing unit (GPU) acceleration, thus ensuring the efficiency of the computation. The results demonstrate that with the support of high-resolution data, the uncertainties of MCFD simulations can be significantly reduced. The proposed approach has the potential for other applications that involve numerical models with empirical parameters.

42 ENGINEERING↗

Hyperpolarizabilities of one and two electron ions under strongly coupled plasma

Systematic investigations on the hyperpolarizabilities of hydrogen and helium like ions up to nuclear charge Z = 7 under strongly coupled plasma environment have been performed. Variation perturbation theory has been adopted to evaluate such properties for the one and two electron systems. For the two electron systems coupled Hartree-Fock theory, which takes care of partial electron correlation effects, has been utilised. Ion sphere model of the strongly coupled plasma, valid for ionic systems only, has been adopted for estimating the effect of plasma environment on the hyperpolarizability. The calculated free ion hyperpolarizability for all the systems is in good agreement with the existing data. Under confinement hyperpolarizabilities of one and two electron ions show interesting trend with respect to plasma coupling strength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neurohumoral indicators of efficacy radiofrequency cardiac denervation

In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are We Appropriately Selecting Therapy For Patients With Cervical Cancer? Longitudinal Patterns-of-Care Analysis for Stage IB-IIB Cervical Cancer

Purpose: We performed a patterns-of-care analysis evaluating the effects of newer technology and recent research findings on treatment decisions over 26 years to determine whether patients with cervical cancer are being appropriately selected for treatment to optimize the therapeutic ratio. Methods and Materials: A retrospective analysis was conducted using the Surveillance, Epidemiology and End Results (SEER) program from 1983 to 2009. We identified 10,933 women with stage IB-IIB cervical carcinoma. Results: Of the 10,933 subjects identified, 40.1% received surgery, 26.8% received radiation (RT), and 33.1% received surgery plus RT. RT use increased after 2000 compared to prior to 2000, with a corresponding decrease in surgery and surgery plus RT. Among patients with risk factors including tumor size >4 cm, positive parametria, and positive lymph nodes, declining use of surgery plus RT was observed. However, 23% of patients with tumors >4 cm, 20% of patients with positive parametria, and 55% of node-positive patients continued to receive surgery plus RT as of 2009. Factors associated with increased use of surgery plus RT included patient age <50 and node-positive status. Conclusions: In this largest patterns-of-care analysis to date for patients with locally advanced cervical cancer, we found a substantial proportion of patients continue to undergo surgery followed by radiation, despite randomized data supporting the use of definitive radiation therapy, with lower morbidity than surgery and radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Doses to Carotid Arteries After Modern Radiation Therapy for Hodgkin Lymphoma: Is Stroke Still a Late Effect of Treatment?

Purpose: Hodgkin lymphoma (HL) survivors are at an increased risk of stroke because of carotid artery irradiation. However, for early-stage HL involved node radiation therapy (INRT) reduces the volume of normal tissue exposed to high doses. Here, we evaluate 3-dimensional conformal radiation therapy (3D-CRT), volumetric-modulated arc therapy (VMAT), and proton therapy (PT) delivered as INRT along with the extensive mantle field (MF) by comparing doses to the carotid arteries and corresponding risk estimates. Methods and Materials: We included a cohort of 46 supradiaphragmatic stage I-II classical HL patients. All patients were initially treated with chemotherapy and INRT delivered as 3D-CRT (30 Gy). For each patient, we simulated MF (36 Gy) and INRT plans using VMAT and PT (30 Gy). Linear dose-response curves for the 20-, 25-, and 30-year risk of stroke were derived from published HL data. Risks of stroke with each technique were calculated for all patients. Statistical analyses were performed with repeated measures analysis of variance. Results: The mean doses to the right and left common carotid artery were significantly lower with modern treatment compared with MF, with substantial patient variability. The estimated excess risk of stroke after 20, 25, and 30 years was 0.6%, 0.86%, and 1.3% for 3D-CRT; 0.67%, 0.96%, and 1.47% for VMAT; 0.61%, 0.96%, and 1.33% for PT; and 1.3%, 1.72%, and 2.61% for MF. Conclusions: INRT reduces the dose delivered to the carotid arteries and corresponding estimated risk of stroke for HL survivors. Even for the subset of patients with lymphoma close to the carotid arteries, the estimated risk is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Positron Emission Tomography–Based Isotoxic Accelerated Radiation Therapy Is Cost-Effective Compared With Conventional Radiation Therapy: A Model-Based Evaluation

Purpose: To evaluate long-term health effects, costs, and cost-effectiveness of positron emission tomography (PET)-based isotoxic accelerated radiation therapy treatment (PET-ART) compared with conventional fixed-dose CT-based radiation therapy treatment (CRT) in non-small cell lung cancer (NSCLC). Methods and Materials: Our analysis uses a validated decision model, based on data of 200 NSCLC patients with inoperable stage I-IIIB. Clinical outcomes, resource use, costs, and utilities were obtained from the Maastro Clinic and the literature. Primary model outcomes were the difference in life-years (LYs), quality-adjusted life-years (QALYs), costs, and the incremental cost-effectiveness and cost/utility ratio (ICER and ICUR) of PET-ART versus CRT. Model outcomes were obtained from averaging the predictions for 50,000 simulated patients. A probabilistic sensitivity analysis and scenario analyses were carried out. Results: The average incremental costs per patient of PET-ART were €569 (95% confidence interval [CI] €−5327-€6936) for 0.42 incremental LYs (95% CI 0.19-0.61) and 0.33 QALYs gained (95% CI 0.13-0.49). The base-case scenario resulted in an ICER of €1360 per LY gained and an ICUR of €1744 per QALY gained. The probabilistic analysis gave a 36% probability that PET-ART improves health outcomes at reduced costs and a 64% probability that PET-ART is more effective at slightly higher costs. Conclusion: On the basis of the available data, individualized PET-ART for NSCLC seems to be cost-effective compared with CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗