Automated Generation of F-16 Flight Paths from Recorded Maneuvers.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Irradiation of aligned nanowire arrays with ultrashort laser pulses of relativistic intensity produces matter in the ultrahigh-energy density regime characterized by gigabar pressures, warranting new experiments in high-energy physics.
Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.
It is recognized that beneficial electrification of most space heating will be necessary to avert the worst consequences of climate change. Fifth generation district heating and cooling (5GDHC) networks operate at near-ambient temperatures and thus facilitate heating electrification, as well as the use of waste heat sources at a wide range of temperatures. In this paper, we analyze the potential of waste heat to supply the required heat to these networks and describe the business models that could expand the use of these waste heat sources. Showcase single family and commercial districts in the US are discussed to demonstrate emerging technologies, district infrastructure approaches, and third-party thermal utility funding models for these leading 5GDHC networks. As part of this work, heat flow and temperature profiles from five different types of waste heat sources are analyzed. An example district is used to examine the integration potential and to quantify the potential reduction in energy consumption. The results indicate that 5GDHC networks are highly suitable systems for utilizing low to moderate temperature waste heat sources. In the studied district, waste heat can cover a share of up to 66% of the heat supplied to the ambient loop and reduce the overall electricity consumption for heating by up to 51%, depending on the characteristics of the specific power, temperature, and type of waste heat source. Through their moderate operating temperatures and use of waste heat sources combined with third party financed infrastructure, 5GDHC districts have significant potential to reduce carbon emissions associated with space conditioning.
Explore the source record for details and available documents.
Abstract not provided.
Today's marine energy industry is at an exciting turning point. Companies are testing out their early-stage prototypes - designed to harness the clean energy in ocean and river waves, currents, and tides - in their first open-water trials. But while such trials are a necessary step toward commercialization, they can come with high costs and risk if the deployments do not go as planned.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Scaling circulating fluidized bed risers has been a point of contention for nearly a century. There have been numerous attempts to define various methodologies. These have all fallen short of providing a robust approach, primarily due to a lack of maintaining microstructure dynamics – a key factor in maintain interphase heat and mass transfer. Recent work by the author put forward an approach based up maintaining dynamic similarity at different scales by ensuring that the microstructure remained similar by maintaining statistical and chaotic parameters across the scale. That work relied on a dimensionless regime map in which the x-axis was defined by the ratio of the solids flux to the saturation carrying capacity. This latter property was only good within the range of the data and it became evident that extrapolation beyond the limits of the data could induce unrealistic conditions. Therefore, literature was reviewed to develop a better correlation for the saturation carrying capacity. In doing so, a critical diameter concept was developed and applied to the correlations for both Geldart Group A and B materials. The critical diameter for Geldart Group A and B materials is 0.2 m and 0.3 m, respectively. The paper then gives examples on how to use the scaling approach to maintain dynamic similarity across the scales.<br>
Embodiment of the present invention includes a magnetic structure and a magnetic structure used in a direct current (DC) to DC energy converter. The magnetic structure has an E-core and a plate, with the plate positioned in contact or in near contact with the post surfaces of the E-core. The E-core has a base, a no-winding leg, a transformer leg, and an inductor leg. The no-winding leg, the transformer leg, and the inductor leg are perpendicular and magnetically in contact with the base. The plate is a flat slab with lateral dimensions generally larger than its thickness. The plate has a plate nose that overlaps a top no-winding leg surface of the no-winding leg with a no-winding gap area to form a no-winding gap with a no-winding gap reluctance. The plate also has a plate end that overlaps a top inductor leg surface of the inductor leg with an inductor gap area to form an inductor gap with an inductor gap reluctance. In some embodiments, e.g., where the duty cycle is less than 50 percent, the inductor gap reluctance will be designed to be less than the no-winding gap reluctance. In these cases, the majority of the magnetic flux that passes through the transformer leg will return through the inductor leg, instead of through the no-winding leg. The inductor and no-winding gap reluctances can he adjusted, so that the electromotive force applied to a charge passing through the inductor will partially cancel the electromotive force applied by the transformer secondary. The gap reluctance ratio can be defined, so that the difference in secondary and inductor electromotive forces is equal to the output voltage defined by an optimal no-ripple duty cycle. In this way no changing current is required through the inductor to create a dI/dt inductive voltage drop across the output inductor. Zero output current ripple is achieved.Various embodiments of the plate, plate shape, and no-winding leg are disclosed. These embodiments allow achieving a high ratio of no-winding gap reluctance to inductor gap reluctance, for practical, affordable magnetic material structures and aspect ratios. A high gap reluctance ratio enables zero output current ripple for the high transformer turns ratios that are needed to achieve high input to output voltage ratios. The embodiments therefore allow achieving low output current ripple for 48 V or higher input voltages, 1 V or lower output voltages, and high output currents.
A system for determining a travel direction that avoids objects when a vehicle travels from a current location to a target location is provided. The system determines a travel direction based on an attract-repel model. The system assigns a repel value to the object locations and an attract value. A repel represents a magnitude of a directional repulsive force, and the attract value represents the magnitude of a directional repulsive force. The system calculates an attract-repel field having an attract-repel magnitude and attract-repel direction for the current location based on the repel values and their directions and the attract value and its direction. The system then determines the travel direction for a vehicle to be the direction of the attract-repel field at the current location.
Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.
Abstract not provided.
The US power industry's story in 2009 will be all about change, to borrow a now-familiar theme. Though the new administration's policy specifics had not been revealed as this report was prepared, it appears that flat load growth in 2009 will give the new Obama administration a unique opportunity to formulate new energy policy without risking that the lights will go out. New coal projects are now facing increasing difficulties. It looks as though the electricity supply industry will continue to muddle through. It may see an advancement in infrastructure investment, significant new generation or new technology development. It also faces the possibility that policies necessary to achieving those goals will not materialize, for political and economic reasons. 4 figs.