Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Development of the electrochemically regenerable carbon dioxide absorber for portable life support system application

As the length of manned space missions increase, more ambitious extravehicular activities (EVAs) are required. For the projected longer mission the use of expendables in the portable life support system (PLSS) will become prohibited due to high launch weight and volume requirements. Therefore, the development of a regenerable CO2 absorber for the PLSS application is highly desirable. The paper discusses the concept, regeneration mechanism, performance, system design, and absorption/regeneration cycle testing of a most promising concept known as ERCA (Electrochemically Regenerable CO2 Absorber). This concept is based on absorbing CO2 into an alkaline absorbent similar to LiOH. The absorbent is an aqueous solution supported in a porous matrix which can be electrochemically regenerated on board the primary space vehicle. With the metabolic CO2 recovery the ERCA concept results in a totally regenerable CO2 scrubber. The ERCA test hardware has passed 200 absorption/regeneration cycles without performance degradation.

Woods, R. R.↗

Charon Message-Passing Toolkit for Scientific Computations

The Charon toolkit for piecemeal development of high-efficiency parallel programs for scientific computing is described. The portable toolkit, callable from C and Fortran, provides flexible domain decompositions and high-level distributed constructs for easy translation of serial legacy code or design to distributed environments. Gradual tuning can subsequently be applied to obtain high performance, possibly by using explicit message passing. Charon also features general structured communications that support stencil-based computations with complex recurrences. Through the separation of partitioning and distribution, the toolkit can also be used for blocking of uni-processor code, and for debugging of parallel algorithms on serial machines. An elaborate review of recent parallelization aids is presented to highlight the need for a toolkit like Charon. Some performance results of parallelizing the NAS Parallel Benchmark SP program using Charon are given, showing good scalability.

VanderWijngaart, Rob F.↗

Charon Message-Passing Toolkit for Scientific Computations

The Charon toolkit for piecemeal development of high-efficiency parallel programs for scientific computing is described. The portable toolkit, callable from C and Fortran, provides flexible domain decompositions and high-level distributed constructs for easy translation of serial legacy code or design to distributed environments. Gradual tuning can subsequently be applied to obtain high performance, possibly by using explicit message passing. Charon also features general structured communications that support stencil-based computations with complex recurrences. Through the separation of partitioning and distribution, the toolkit can also be used for blocking of uni-processor code, and for debugging of parallel algorithms on serial machines. An elaborate review of recent parallelization aids is presented to highlight the need for a toolkit like Charon. Some performance results of parallelizing the NAS Parallel Benchmark SP program using Charon are given, showing good scalability. Some performance results of parallelizing the NAS Parallel Benchmark SP program using Charon are given, showing good scalability.

VanderWijngarrt, Rob F.↗

Monitoring Outpatient Care

Each year, health care costs for managing chronically ill patients increase as the life expectancy of Americans continues to grow. To handle this situation, many hospitals, doctors practices, and home care providers are turning to disease management, a system of coordinated health care interventions and communications, to improve outpatient care. By participating in daily monitoring programs, patients with congestive heart failure, chronic obstructive pulmonary disease, diabetes, and other chronic conditions requiring significant self-care are facing fewer emergency situations and hospitalizations. Cybernet Medical, a division of Ann Arbor, Michigan-based Cybernet Systems Corporation, is using the latest communications technology to augment the ways health care professionals monitor and assess patients with chronic diseases, while at the same time simplifying the patients interaction with technology. Cybernet s newest commercial product for this purpose evolved from research funded by NASA, the National Institute of Mental Health, and the Advanced Research Projects Agency. The research focused on the physiological assessment of astronauts and soldiers, human performance evaluation, and human-computer interaction. Cybernet Medical's MedStar Disease Management Data Collection System is an affordable, widely deployable solution for improving in-home-patient chronic disease management. The system's battery-powered and portable interface device collects physiological data from off-the-shelf instruments.

Source record↗

Contributions of Astronauts Aerobic Exercise Intensity and Time on Change in VO2peak during Spaceflight

There is considerable variability among astronauts with respect to changes in maximal aerobic capacity (VO2peak) during International Space Station (ISS) missions, ranging from a 5% increase to 30% decline. Individual differences may be due to in-flight aerobic exercise time and intensity. PURPOSE: To evaluate the effects of in-flight aerobic exercise time and intensity on change in VO2peak during ISS missions. METHODS: Astronauts (N=11) performed peak cycle tests approx 60 days before flight (L-60), on flight day (FD) approx 14, and every approx 30 days thereafter. Metabolic gas analysis and heart rate (HR) were measured continuously during the test using the portable pulmonary function system. HR and duration of each in-flight cycle ergometer and treadmill (TM) session were recorded and averaged in time segments corresponding to each peak test. Mixed effects linear regression with exercise mode (TM or cycle) as a categorical variable was used to assess the contributions of exercise intensity (%time >70% peak HR or %time >90% peak HR) and time (min/wk), adjusted for body weight, on %change in VO2peak during the mission, and incorporating the repeated-measures experimental design. RESULTS: 110 observations were included in the model (4-6 peak cycle tests per astronaut, 2 exercise devices). VO2peak was reduced from preflight throughout the mission (FD14: 13+/-13% and FD 105: 8+/-10%). Exercise intensity (%peak HR: FD14=66+/-14; FD105=75+/-8) and time (min/wk: FD14=82+/-46; FD105=158+/-40) increased during flight. The models showed main effects for exercise time and intensity with no interactions between time, intensity, and device (70% peak HR: time [z-score=2.39; P=0.017], intensity [z-score=3.51; P=0.000]; 90% peak HR: time [zscore= 3.31; P=0.001], intensity [z-score=2.24; P=0.025]). CONCLUSION: Exercise time and intensity independently contribute to %change in VO2peak during ISS missions, indicating that there are minimal values for exercise time and intensity required to maintain VO2peak. As the FD105 average exercise intensity and time did not prevent a decline in VO2peak from preflight, astronauts' exercise prescriptions should target at least 160 min of weekly aerobic exercise at an average above 75% peak HR with increased time at intensities above 90% of peak HR starting early in the mission.

Downs, Meghan E.↗

Development of polymer 'chips' used in medical diagnostics

In recent years, there has been growing interest in creating bio-inspired devices that feature artificial bilayer lipid membranes (BLM), or lipid bilayers. These membranes can be tailored to mimic the structure and transport properties of cellular walls and can be used to selectively transport ions and other species between aqueous volumes. One application of this research is the formation of a standardized BLM contained within a portable and disposable housing for use in medical diagnostics. This concept utilizes a flexible polymer 'chip' that has internal compartments for housing both an organic solvent and an aqueous solution, which contains phospholipid molecules, proteins, and specific analyte molecules. The formation of a BLM within the chip enables integration of the chip into an electronic reader to perform diagnostic measurements of the sample. A key element of the bilayer formation process requires a single aqueous volume to first be separated into multiple volumes such that it can then be reattached to form a bilayer at the interface. This process, called the regulated attachment method, relies on the geometry of the deformable 'chip' to separate and reattach the aqueous contents held inside by opening and closing an aperture that divides adjacent compartments through the application of mechanical force. The purpose of this research is to develop an optimized chip that provides a controllable method for initially separating the aqueous phase via dynamic excitation. This study focuses on two specific aspects: designing an efficient excitation method for separating the aqueous volume, and optimizing the geometry of the chip to decrease the required input energy and better target the location and duration of the separation. Finite Element (FE) models are used to optimize the chip geometry and to identify suitable excitation signals. A series of experimental studies are also presented to validate the FE models.

42 ENGINEERING↗

OpenSHMEM: Towards a Unified RMA Model

For many problem domains, one-sided communication paradigms, such as RMA (remote memory access), dominate the solution space on massively parallel systems through their ability to preserve problem tractability, high scalability, and overall performance. How- ever, unlike the MPI standard for two-sided communication, there is no single, successful standard RMA model or interface for one-sided communication, though the SHMEM family of APIs have a long history of success spanning many years and multiple platforms. While the various SHMEM implementations have remained similar across numerous implementations, the subtle differences have hindered acceptance, portability, and in some cases, program cor- rectness. In this paper, we will discuss the differences between SHMEM implementations and contrast SHMEM with other extant libraries supporting RMA semantics to provide motivation for a standards-based OpenSHMEM with the requisite breadth of functionality.

99 GENERAL AND MISCELLANEOUS↗

An Effectively Activated Hierarchical Nano-/Microspherical Li 1.2 Ni 0.2 Mn 0.6 O 2 Cathode for Long-Life and High-Rate Lithium-Ion Batteries

Rechargeable lithium-ion batteries with high energy and high power density are required in the application of electric vehicles and portable electronics. Herein, we introduce a type of spherical Li-rich cathode material, Li1.2Ni0.2Mn0.6O2, assembled from uniform nanocubes by a facile polyvinylpyrrolidone (PVP)-assisted hydrothermal method. The material with a hierarchical nano-/microstructure exhibits stable high-rate performance. Furthermore, the precipitant (i.e., urea) and the structure-directing agent (i.e., PVP) effectively activated the Li2MnO3 components in the microscale material to achieve a high specific capacity of 298.5 mAh g-1 in the first cycle. This Li-rich cathode material still delivered 243 mAh g-1 at 0.1 C after 200 cycles and the capacity retentions at 0.5, 1, 2, and 5mC were 94.4, 78.7, 76.3, and 67.8 % after 150 cycles, respectively. The results make this Li-rich nano-/microstructure a promising cathode material for long-life and high-performance lithium-ion batteries.

25 ENERGY STORAGE↗

An isotope identification injection study with GammaTracker

GammaTracker is a portable handheld radioisotope identifier using position sensitive CdZnTe detectors. High confidence isotope identification is possible on GammaTracker owing to the system's relatively high energy resolution and count rate sensitivity. A study was undertaken to evaluate the isotope identification performance of a prototype unit. Background and source spectra for various nuclides were measured and then randomly sampled to simulate various integration times and source intensities. The resulting spectral data sets were then run through the isotope identification algorithm to determine the probability of detection and the false alarm rate for each nuclide. The process was repeated for various isotope identification input parameters until an optimized set was achieved. This paper presents results from the injection study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-Assembled Framework Formed During Lithiation of SnS 2 Nanoplates Revealed by in Situ Electron Microscopy

Lithium-ion batteries (LIBs) commercially dominate portable energy storage and have been extended to hybrid/electric vehicles by utilizing electrode materials with enhanced energy density. However, the energy density and cycling life of LIBs must extend beyond the current reach of commercial electrodes to meet the performance requirements for transportation applications. Carbon-based anodes, serving as the main negative electrodes in LIBs, have an intrinsic capacity limitation due to the intercalation mechanism. Some nanostructured carbon materials offer very interesting reversible capacities and can be considered as future anode materials. However, their fabrication processes are often complicated and expensive. Theoretically, using a lithium metal anode is the best way of delivering high energy density due to its largest theoretical capacity of more than 3800 mAh g -1 ; however, lithium metal is highly reactive with liquid electrolytes. Alternative anodes are being explored, including other lithium-reactive metals, such as Si, Ge, Zn, V, and so forth. These metals react reversibly with a large amount of Li per formula unit to form lithium–metal alloys, rendering these materials promising candidates for next-generation LIBs with high energy density. Though, most of these pure metallic anodes experience large volume changes during lithiation and delithiation processes that often results in cracking of the anode material and a loss electrical contact between the particles.Nanosized metal sulfides were recently found to possess better cycling stability and larger reversible capacities over pure metals. Further improvements and developments of metal sulfide-based anodes rely on a fundamental understanding of their electrochemical cycling mechanisms. Not only must the specific electrochemical reactions be correctly identified, but also the microstructural evolution upon electrochemical cycling, which often dictates the cyclability and stability of nanomaterials in batteries, must be clearly understood. Probing these dynamic evolution processes, i.e. the lithiation reactions and morphology evolutions, are often challenging. It requires both high-resolution chemical analysis and microstructural identification. In situ transmission electron microscopy (TEM) coupled with electron energy loss spectroscopy (EELS) has recently been raised as one of the most powerful techniques for monitoring electrochemical processes in anode materials for LIBs.In this work, we focus on elucidating the origin of the structural stability of SnS 2 during electrochemical cycling by revealing the microstructural evolution of SnS 2 upon lithiation using in situ TEM. Crystalline SnS 2 was observed to undergo a two-step reaction after the initial lithium intercalation: (1) irreversible formation of metallic tin and amorphous lithium sulfide and (2) reversible transformation of metallic tin to Li–Sn alloys, which is determined to be the rate-determining step. More interestingly, it was discovered that a self-assembled composite framework formed during the irreversible conversion reaction, which has not been previously reported. Crystalline Sn nanoparticles are well arranged within an amorphous Li 2 S “matrix” in this self-assembled framework. This nanoscale framework confines the locations of individual Sn nanoparticles and prevents particle agglomeration during the subsequent cycling processes, therefore providing desired structural tolerance and warranting a sufficientelectron pathway. Finally, our results not only explain the outstanding cycling stability of SnS 2 over metallic tin anodes, but also provide important mechanistic insights into the design of high-performance electrodes for next-generation LIBs through the integration of a unique nanoframework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shear-horizontal surface acoustic wave phononic device with high density filling material for ultra-low power sensing applications

Finite element simulations of a phononic shear-horizontal surface acoustic wave (SAW) sensor based on ST 90°-X Quartz reveal a dramatic reduction in power consumption. The phononic sensor is realized by artificially structuring the delay path to form an acoustic meta-material comprised of a periodic microcavity array incorporating high-density materials such as tantalum or tungsten. Constructive interference of the scattered and secondary reflected waves at every microcavity interface leads to acoustic energy confinement in the high-density regions translating into reduced power loss. Tantalum filled cavities show the best performance while tungsten inclusions create a phononic bandgap. Based on our simulation results, SAW devices with tantalum filled microcavities were fabricated and shown to significantly decrease insertion loss. Our findings offer encouraging prospects for designing low power, highly sensitive portable biosensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗

Architectural study of the design and operation of advanced force feedback manual controllers

A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof concepts is presented as a feasible test-bed for enhanced performance in a 9-dof system.

Tesar, Delbert↗

Testing and Oxygen Assessment Results for a Next Generation Extravehicular Activity Portable Life Support System Fan

NASA is designing a next generation Extravehicular Activity (EVA) Portable Life Support System (PLSS) for use in future surface exploration endeavors. To meet the new requirements for ventilation flow at nominal and buddy modes, a fan has been developed and tested. This paper summarizes the results of the performance and life cycle testing efforts conducted at the NASA Johnson Space Center. Additionally, oxygen compatibility assessment results from an evaluation conducted at White Sands Test Facility (WSTF) are provided, and lessons learned and future recommendations are outlined.

Paul, Heather L.↗

Space Evaporator-Absorber-Radiator (SEAR)

A system for non-venting thermal control for spacesuits was built by integrating two previously developed technologies, namely NASA s Spacesuit Water Membrane Evaporator (SWME), and Creare s flexible version of the Lithium Chloride Absorber Radiator (LCAR). This SEAR system was tested in relevant thermal vacuum conditions. These tests show that a 1 m2 radiator having about three times as much absorption media as in the test article would be required to support a 7 hour spacewalk. The serial flow arrangement of the LCAR of the flexible version proved to be inefficient for venting non-condensable gas (NCG). A different LCAR packaging arrangement was conceived wherein the Portable Life Support System (PLSS) housing would be made with a high-strength carbon fiber composite honeycomb, the cells of which would be filled with the chemical absorption media. This new packaging reduces the mass and volume impact of the SEAR on the Portable Life Support System (PLSS) compared to the flexible design. A 0.2 sq m panel with flight-like honeycomb geometry is being constructed and will be tested in thermal and thermal vacuum conditions. Design analyses forecast improved system performance and improved NCG control. A flight-like regeneration system also is also being built and tested. Design analyses for the structurally integrated prototype as well as the earlier test data show that SEAR is not only practical for spacesuits but also has useful applications in spacecraft thermal control.

Bue, Grant C.↗

Multifunctional Space Evaporator-Absorber-Radiator (SEAR)

A system for non-venting thermal control for spacesuits was built by integrating two previously developed technologies, namely NASA's Spacesuit Water Membrane Evaporator (SWME), and Creare's flexible version of the Lithium Chloride Absorber Radiator (LCAR). This SEAR system was tested in relevant thermal vacuum conditions. These tests show that a 1 sq m radiator having about three times as much absorption media as in the test article would be required to support a 7 hour spacewalk. The serial flow arrangement of the LCAR of the flexible version proved to be inefficient for venting non-condensable gas (NCG). A different LCAR packaging arrangement was conceived wherein the Portable Life Support System (PLSS) housing would be made with a high-strength carbon fiber composite honeycomb, the cells of which would be filled with the chemical absorption media. This new packaging reduce the mass and volume impact of the SEAR on the Portable Life Support System (PLSS) compared to the flexible design. A 0.2 sq m panel with flight-like honeycomb geometry is being constructed and will be tested in thermal and thermal vacuum conditions. Design analyses forecast improved system performance and improved NCG control. A flight-like regeneration system also is also being built and tested. Design analyses for the structurally integrated prototype as well as the earlier test data show that SEAR is not only practical for spacesuits but also has useful applications in spacecraft thermal control.

Bue, Grant C.↗

Development of Field-Portable CdZnTe (CZT) Radiation Detectors to Monitor and Localize Special Nuclear Materials

For nearly 40 years, CdTe and later CZT have been the room temperature detector of choice for critical applications where traditional scintillators were inadequate and the cost and cooling requirements of germanium were prohibitive. This situation has not changed. At the low end of performance, the detector needs of the vast majority of commercial applications are satisfied with the very low costs scintillators, NaI(Tl) and CsI(Tl). Prices can be as low as a few dollars per cubic centimeter and in sizes up to thousands of cubic centimeters. The availability of these materials stifles the market driven incentive to develop more cost effective production techniques for semiconductor detector materials. Thus, it is unlikely that any semiconductor will replace these materials in the foreseeable future.

36 MATERIALS SCIENCE↗

Flexible, highly efficient all-polymer solar cells

All-polymer solar cells have shown great potential as flexible and portable power generators. These devices should offer good mechanical endurance with high power-conversion efficiency for viability in commercial applications. In this work, we develop highly efficient and mechanically robust all-polymer solar cells that are based on the PBDTTTPD polymer donor and the P(NDI2HD-T) polymer acceptor. These systems exhibit high power-conversion efficiency of 6.64%. Also, the proposed all-polymer solar cells have even better performance than the control polymer-fullerene devices with phenyl-C61-butyric acid methyl ester (PCBM) as the electron acceptor (6.12%). More importantly, our all-polymer solar cells exhibit dramatically enhanced strength and flexibility compared with polymer/PCBM devices, with 60- and 470-fold improvements in elongation at break and toughness, respectively. The superior mechanical properties of all-polymer solar cells afford greater tolerance to severe deformations than conventional polymer-fullerene solar cells, making them much better candidates for applications in flexible and portable devices.

14 SOLAR ENERGY↗