Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Evolution of irradiation defects in Ti 2 AlC ceramics during heavy ion irradiation

Here, the evolution of irradiation defects in Ti 2 AlC under Kr ion irradiation at room and elevated temperatures has been investigated. The dependence of defect size and density on the irradiation dose and temperature was characterized by in-situ transmission electron microscopy (TEM) irradiation experiments. At 25-800 °C, interstitial-type dislocation loops with several nanometers in diameter form on the basal plane of Ti 2 AlC mostly with a Burgers vector of 1/2[0 0 0 1], and no voids have been observed. The number density of dislocation loops approaches saturation at a level of about 2 dpa at 800 °C. Ti 2 AlC samples remain crystalline in structure without amorphization or phase transformation. However, the localized disorder of atomic positions on the basal plane of the irradiated Ti 2 AlC was revealed by high-resolution transmission electron microscopy (HRTEM) studies, which increases with irradiation dose while decreases with elevated temperatures.

36 MATERIALS SCIENCE↗

Global and local texture development during initial plastic deformation of cold-pilgered Zircaloy-4 tubing

In this work we present a thorough characterization of the texture development during the initial step of a cold pilgering process of a Zircaloy-4 TREX tube, on which the axial cross section is reduced by 80% over a 40cm length with an overall Q-ratio of 2.34, followed by a recrystallization thermal treatment. Texture across a tapered specimen representing this working zone was characterized by neutron diffraction and high energy synchrotron x-ray diffraction at 28 positions (4 locations along its length and 7 locations across its thickness with 0.3 mm spatial resolution), and on the deformed end after the thermal treatment. Results show that the starting material (TREX tube) presents a texture gradient through its wall thickness, with the c poles aligned to the hoop direction at the outer surface (with radial and hoop Kearns factors: f R =0.36, f H = 0.50), and gradually rotating around the axial direction to become a quasi-radial orientation (~35 o out of the radial direction) at the inner surface ( f R =0.43, f H =0.35). The overall texture becomes more radial due to the cold pilgering, but the texture gradient remains during the whole deformation process, being always more radial at the inner surface, ( f R =0.53, f H =0.37 at 80%) than at the outer surface ( f R =0.41, f H =0.50at 80%). The most remarkable changes in texture produced by the rolling process is a 30 o rotation of the grains around their c-axis, producing a marked increase of the <11 2 ¯ 0> // axial fiber texture at expenses of the original <10 1 ¯ 0> // axial fiber texture observed in the TREX tube. The observed changes in texture during deformation were correctly explained by visco-plastic self-consistent (VPSC) modelling. This was achieved after the inclusion of the basal <a> slip system, which plays a central role to explain the 30 o rotation around the c-axis during deformation. The texture evolution was correctly described after the inclusion of a drag effect to grain rotation due to the interaction with neighbouring grains. The through thickness texture differences are greatly reduced by the recrystallization thermal treatment, with similar Kearns factors at the inner surface ( f R =0.50, f H =0.28) and the outer surface ( f R =0.48, f H =0.39). The predominance of the <10 1 ¯ 0> // axial fiber texture is recovered after recrystallization.

36 MATERIALS SCIENCE↗

Crystal structure and magnetic properties of complex oxides Mg{sub 4-x}Ni{sub x}Nb{sub 2}O{sub 9}, 0{<=}x{<=}4

In the Mg{sub 4-x}Ni{sub x}Nb{sub 2}O{sub 9} (0{<=}x{<=}4) system two ranges of solid solution have been found. One of the solid solutions has a corundum-related structure type (space group P3-barc1); the second one adopts the II-Ni{sub 4}Nb{sub 2}O{sub 9} structure type (space group Pbcn). The unit cell constants and atomic positions have been determined and refined using neutron powder diffraction data. Electron diffraction and high-resolution transmission electron microscopy (HRTEM) from MgNi{sub 3}Nb{sub 2}O{sub 9} crystals identify the presence of planar defects and the intergrowth of several (structurally related) phases. The magnetic susceptibility of Mg{sub 3}NiNb{sub 2}O{sub 9}, measured in the temperature range T=2-300 K, shows no indications of magnetic ordering at low temperatures, while for MgNi{sub 3}Nb{sub 2}O{sub 9} there is a magnetic ordering at temperatures below 45.5 K. - Graphical abstract: HREM image showing planar defects in MgNi{sub 3}Nb{sub 2}O{sub 9} and their schematic representation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio structure determination and Rietveld refinement of Bi{sub 10}Mo{sub 3}O{sub 24} the member n=3 of the Bi{sub 2n+4}Mo{sub n}O{sub 6(n+1)} series

Bi{sub 2}O{sub 3}-MoO{sub 3} system shows a large panoply of phases depending on Bi/Mo ratio, among them, the low temperature phases of the homologous series Bi{sub 2(n+2)}Mo{sub n}O{sub 6(n+1)} with n=3, 4, 5 and 6. They exhibit, alike most of the phases of this system, strong fluorite sub-network. Nevertheless, a multitechnique approach has been followed in order to solve the crystal structure of the n=3 member, i.e. Bi{sub 10}Mo{sub 3}O{sub 24}. From ab initio indexing X-ray powder pattern cell parameters were derived. It belongs to the monoclinic system, space group C2, with cell parameters: a=23.7282(2) A, b=5.64906(6) A, c=8.68173(9) A, beta=95.8668(7){sup o} with Z=2. The matrix relating this cell with the fluorite one is 4 0 1/0 1 0/-1/2 0 3/2 and a cationic localization was derived. HRTEM allowed the cationic Bi and Mo order to be modified and specified, as well as to build up a full structural ab initio model on the basis of crystal chemistry considerations. Simultaneous Rietveld refinement of multipattern X-ray and neutron powder diffraction data taking advantage of the neutron scattering length for O location have been performed. The goodness of the model was ascertained by low reliability factors, weighted R{sub b}=4.97% and R{sub f}=3.21%. This complex Bi{sub 10}Mo{sub 3}O{sub 24} structure, with 5Bi, 2Mo and 13O in different crystallographic positions of the asymmetric unit, shows good agreement between observed and calculated patterns within the data resolution. Moreover, the determination of this structure sets the basis for the crystallographic characterization of the complete family Bi{sub 2(n+2)}Mo{sub n}O{sub 6(n+1)}, whose guidelines are also evidenced in this paper. - Graphical abstract: This work reports on the ab initio determination of Bi{sub 10}Mo{sub 3}O{sub 24} structure, as well as its refinement by using the Rietveld method, from the combination of X-ray and neutron diffraction powder data. It belongs to the monoclinic system, space group C2, with cell parameters: a=23.7282(2) A, b=5.64906(6) A, c=8.68173(9) A, beta=95.8668(7){sup o} with Z=2.

36 MATERIALS SCIENCE↗

Site specific porosity-thermal performance correlations in neutron irradiated U-10Zr fuel

In this work, we present a site-specific three-dimensional analysis of porosity evolution in neutron-irradiated U–10Zr metallic fuel using high-resolution synchrotron X-ray tomography. Focused ion beam cubic lift-outs from four radial positions—fuel center, middle, edge, and fuel-cladding interaction (FCCI) zones—were imaged, reconstructed, and segmented to quantify pore volume, density, morphology, and pore connectivity. Porosity increased modestly from 5.5% at the center to 10.5% at the edge, yet pore number density increased by over two orders of magnitude in the fuel portion near the FCCI interface (from 4.8 x 10 4 to 6.0 x 10 6 pores/mm 3 ). Morphological classification revealed a progression from small spherical pores at the center to equiaxed and tortuous networks at the periphery, with enhanced orientation along the radial direction. Connectivity and permeability analysis reveal that the FCCI region maintains dense, highly interconnected pores despite a moderate volume fraction, enabling rapid fission gas transport and lanthanide migration. Effective thermal conductivity models incorporating sodium logging confirm that these site-specific pore features critically influenced heat transport during reactor irradiation. These findings demonstrate that pore topology—not just porosity fraction—controls thermal performance and thermal pathways in U–10Zr fuels, impacting fuel thermal performance in a reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Adeno-associated virus-2 and its primary cellular receptor-Cryo-EM structure of a heparin complex

Adeno-associated virus serotype 2 (AAV-2) is a leading candidate vector for gene therapy. Cell entry starts with attachment to a primary receptor, Heparan Sulfate Proteoglycan (HSPG) before binding to a co-receptor. Here, cryo-electron microscopy provides direct visualization of the virus-HSPG interactions. Single particle analysis was performed on AAV-2 complexed with a 17 kDa heparin fragment at 8.3 A resolution. Heparin density covers the shoulder of spikes surrounding viral 3-fold symmetry axes. Previously implicated, positively charged residues R{sub 448/585}, R{sub 451/588} and R{sub 350/487} from another subunit cluster at the center of the heparin footprint. The footprint is much more extensive than apparent through mutagenesis, including R{sub 347/484}, K{sub 395/532} and K{sub 390/527} that are more conserved, but whose roles have been controversial. It also includes much of a region proposed as a co-receptor site, because prior studies had not revealed heparin interactions. Heparin density bridges over the viral 3-fold axes, indicating multi-valent attachment to symmetry-related binding sites.

60 APPLIED LIFE SCIENCES↗

TANAMI blazars in the IceCube PeV-neutrino fields

The IceCube Collaboration has announced the discovery of a neutrino flux in excess of the atmospheric background. Owing to the steeply falling atmospheric background spectrum, events at PeV energies most likely have an extraterrestrial origin. We present the multiwavelength properties of the six radio-brightest blazars that are positionally coincident with these events using contemporaneous data of the TANAMI blazar sample, including high-resolution images and spectral energy distributions. Assuming the X-ray to γ-ray emission originates in the photoproduction of pions by accelerated protons, the integrated predicted neutrino luminosity of these sources is high enough to explain the two detected PeV events.

79 ASTRONOMY AND ASTROPHYSICS↗

Pattern recognition techniques to reduce backgrounds in the search for the {sup 136}Xe double beta decay with gaseous TPCs

The observation of the neutrinoless double beta decay may provide essential information on the nature of neutrinos. Among the current experimental approaches, a high pressure gaseous TPC is an attractive option for the search of double beta decay due to its good energy resolution and the detailed topological information of each event. We present in this talk a detailed study of the ionization topology of the {sup 136}Xe double beta decay events in a High Pressure Xenon TPC, as well as that of the typical competing backgrounds. We define some observables based on graph theory concepts to develop automated discrimination algorithms. Our criteria are able to reduce the background level by about three orders of magnitude in the region of interest of the {sup 136}Xe Q{sub ββ} for a signal acceptance of 40%. This result provides a quantitative assessment of the benefit of topological information offered by gaseous TPCs for double beta decay search, and proves that it is a promising feature in view of future experiments in the field. Possible ideas for further improvement in the discrimination algorithms and the dependency of these results with the gas diffusion and readout granularity will be also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of extended magnetic probe set to improve 3D field detection in NSTX-U

Adding toroidal arrays of magnetic probes at the top and bottom of NSTX-U would improve both the detection of the multimodal plasma response to applied magnetic perturbations and the identification of the poloidal structure of unstable plasma modes, as well as contribute to the validation of MHD models, improve the understanding of the plasma response to external fields, and improve the error field correction. In this paper, the linear MHD code MARS-F/K has been used to identify poloidal locations that would improve the capability to measure stationary or near-stationary 3D fields that may result from the plasma response to external sources of non-axisymmetric fields. The study highlighted 6 poloidal positions where new arrays of both poloidal and radial magnetic field sensors would improve the poloidal resolution. Here, the proposed set of new arrays combined with the present ones is shown to be capable of measuring the poloidal structure of perturbations with n ≤ 6 and of detecting the multimodal plasma response. Assessment of the trade-off in the poloidal length of the probes leads to an ideal length between 10 cm and 30 cm. A method to configure the probes of a toroidal array based on the singular value decomposition condition number is proposed, and an ideal solution and a low-cost one are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VLBI DETECTION OF AN ACTIVE GALACTIC NUCLEUS PAIR IN THE BINARY BLACK HOLE CANDIDATE SDSS J1536+0441

We present the first pc-scale radio imaging of the radio-quiet candidate binary black hole system SDSS J1536+0441. The observations were carried out by the European VLBI Network at a frequency of 5 GHz, allowing the imaging of SDSS J1536+0441 with a resolution of {approx}10 mas ({approx}50 pc). Two compact radio cores are detected at the position of the kpc-scale components VLA-A and VLA-B, proving the presence of two compact active nuclei with radio luminosity L{sub R} {approx} 10{sup 40} erg s{sup -1}, thus ruling out the possibility that both radio sources are powered by a 0.1 pc binary black hole. From a comparison with published 8.5 GHz flux densities, we derived an estimate of the radio spectral index of the two pc-scale cores. Both cores have a flat or an inverted spectral index, and at least for the case of VLA-A we can rule out the possibility that synchrotron self-absorption is responsible for the inverted radio spectrum. We suggest that thermal free-free emission from an X-ray-heated disk wind may be powering the radio emission in VLA-A.

79 ASTRONOMY AND ASTROPHYSICS↗

TOTAL MOLECULAR GAS MASSES OF z {approx} 3 LYMAN- BREAK GALAXIES: CO(J = 1 {yields} 0) EMISSION IN MS 1512-cB58 AND THE COSMIC EYE

We report the detection of CO(J = 1 {yields} 0) emission toward the lensed L {sup *} {sub UV} Lyman-break galaxies (LBGs) MS 1512-cB58 (z = 2.73) and the Cosmic Eye (z = 3.07), using the Expanded Very Large Array. The strength of the CO line emission reveals molecular gas reservoirs with masses of (4.6 {+-} 1.1) x 10{sup 8} ({mu}{sub L}/32){sup -1} ({alpha}{sub CO}/0.8) M {sub sun} and (9.3 {+-} 1.6) x 10{sup 8} ({mu}{sub L}/28){sup -1} ({alpha}{sub CO}/0.8) M {sub sun}, respectively. These observations suggest {approx}30%-40% larger gas reservoirs than previously estimated based on CO(J = 3 {yields} 2) observations due to subthermal excitation of the J = 3 line. These observations also suggest gas mass fractions of 0.46 {+-} 0.17 and 0.16 {+-} 0.06. The CO(J = 1 {yields} 0) emission in the Cosmic Eye is slightly resolved on scales of 4.''5 {+-} 1.''5, consistent with previous studies of nebular emission lines. This suggests that the molecular gas is associated with the most intensely star-forming regions seen in the ultraviolet (UV). We do not resolve the CO(J = 1 {yields} 0) emission in cB58 at {approx}2'' resolution, but find that the CO(J = 1 {yields} 0) emission is also consistent with the position of the UV-brightest emission peak. The gas masses, gas fractions, moderate CO line excitation, and star formation efficiencies in these galaxies are consistent with what is found in nearby luminous infrared galaxies. These observations thus currently represent the best constraints on the molecular gas content of 'ordinary' (i.e., {approx}L* {sub UV}) z {approx} 3 star-forming galaxies. Despite comparable star formation rates, the gas properties of these young LBGs seem to be different from the recently identified optical/infrared-selected high-z massive, gas-rich star-forming galaxies, which are more gas-rich and massive, but have lower star formation efficiencies, and presumably trace a different galaxy population.

79 ASTRONOMY AND ASTROPHYSICS↗

AROUND THE RING WE GO: THE COLD, DENSE RING OF MOLECULAR GAS IN NGC 1614

We present high-resolution archival Atacama Large Millimeter/submillimeter Array (ALMA) {sup 12}CO J = 3-2 and J = 6-5 and HCO{sup +} J = 4-3 observations and new CARMA {sup 12}CO and {sup 13}CO J = 1-0 observations of the luminous infrared galaxy NGC 1614. The high-resolution maps show the previously identified ring-like structure while the {sup 12}CO J = 3-2 map shows extended emission that traces the extended dusty features. We combined these new observations with previously published Submillimeter Array {sup 12}CO and {sup 13}CO J = 2-1 observations to constrain the physical conditions of the molecular gas at a resolution of 230 pc using a radiative transfer code and a Bayesian likelihood analysis. At several positions around the central ring-like structure, the molecular gas is cold (20-40 K) and dense (>10{sup 3.0} cm{sup –3}). The only region that shows evidence of a second molecular gas component is the ''hole'' in the ring. The {sup 12}CO-to-{sup 13}CO abundance ratio is found to be greater than 130, more than twice the local interstellar medium value. We also measure the CO-to-H{sub 2} conversion factor, α{sub CO}, to range from 0.9 to 1.5 M {sub ☉} (K km s{sup –1} pc{sup 2}){sup –1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning-based spatiotemporal multi-event reconstruction for delay line detectors

Abstract Accurate observation of two or more particles within a very narrow time window has always been a challenge in modern physics. It creates the possibility of correlation experiments, such as the ground-breaking Hanbury Brown–Twiss experiment, leading to new physical insights. For low-energy electrons, one possibility is to use a Microchannel plate with subsequent delay lines for the readout of the incident particle hits, a setup called a Delay Line Detector. The spatial and temporal coordinates of more than one particle can be fully reconstructed outside a region called the dead radius. For interesting events, where two electrons are close in space and time, the determination of the individual positions of the electrons requires elaborate peak finding algorithms. While classical methods work well with single particle hits, they fail to identify and reconstruct events caused by multiple nearby particles. To address this challenge, we present a new spatiotemporal machine learning model to identify and reconstruct the position and time of such multi-hit particle signals. This model achieves a much better resolution for nearby particle hits compared to the classical approach, removing some of the artifacts and reducing the dead radius a factor of eight. We show that machine learning models can be effective in improving the spatiotemporal performance of delay line detectors.

Computer Science↗

Role of Cross-Helicity in Magnetohydrodynamic Turbulence

Strong incompressible three-dimensional magnetohydrodynamic turbulence is investigated by means of high-resolution direct numerical simulations. The simulations show that the configuration space is characterized by regions of positive and negative cross-helicity, corresponding to highly aligned or antialigned velocity and magnetic field fluctuations, even when the average cross-helicity is zero. To elucidate the role of cross-helicity, the spectra and structure of turbulence are obtained in 'imbalanced' regions where cross-helicity is nonzero. When averaged over regions of positive and negative cross-helicity, the result is consistent with the simulations of balanced turbulence. An analytical explanation for the obtained results is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sweep-tracing algorithm: in silico slip crystallography and tension-compression asymmetry in BCC metals

Abstract Direct Molecular Dynamics (MD) simulations are being increasingly employed to model dislocation-mediated crystal plasticity with atomic resolution. Thanks to the dislocation extraction algorithm (DXA), dislocation lines can be now accurately detected and positioned in space and their Burgers vector unambiguously identified in silico, while the simulation is being performed. However, DXA extracts static snapshots of dislocation configurations that by themselves present no information on dislocation motion. Referred to as a sweep-tracing algorithm (STA), here we introduce a practical computational method to observe dislocation motion and to accurately quantify its important characteristics such as preferential slip planes (slip crystallography). STA reconnects pairs of successive snapshots extracted by DXA and computes elementary slip facets thus precisely tracing the motion of dislocation segments from one snapshot to the next. As a testbed for our new method, we apply STA to the analysis of dislocation motion in large-scale MD simulations of single crystal plasticity in BCC metals. We observe that, when the crystal is subjected to uniaxial deformation along its [001] axis, dislocation slip predominantly occurs on the {112} maximum resolved shear stress plane under tension, while in compression slip is non-crystallographic (pencil) resulting in asymmetric mechanical response. The marked contrast in the observed slip crystallography is attributed to the twinning/anti-twinning asymmetry of shears in the {112} planes relatively favoring dislocation motion in the twinning sense while hindering dislocations from moving in the anti-twinning directions.

36 MATERIALS SCIENCE↗

High-Resolution PET Detector. Final report

The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗