Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Feasibility Study of Economics and Performance of Biopower at the Chanute Air Force Base in Rantoul, Illinois. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Former Chanute Air Force Base site in Rantoul, Illinois, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) was contacted to provide technical assistance for this project. The purpose of this study was to assess the site for a possible biopower system installation and estimate the cost, performance, and impacts of different biopower options.

09 BIOMASS FUELS↗

Feasibility Study of Economics and Performance of Solar Photovoltaics at the Standard Chlorine of Delaware Superfund Site in Delaware City, Delaware - A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Standard Chlorine of Delaware site in Delaware City, Delaware, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) provided technical assistance for this project. The purpose of this report is to assess the site for a possible photovoltaic (PV) system installation and estimate the cost, performance, and site impacts of different PV options. In addition, the report recommends financing options that could assist in the implementation of a PV system at the site.

14 SOLAR ENERGY↗

Y-12 Groundwater Protection Program CY 2009 Triennial Report Of The Monitoring Well Inspection And Maintenance Program, Y-12 National Security Complex, Oak Ridge, Tennessee

This document is the triennial report for the Well Inspection and Maintenance Program of the Y- 12 Groundwater Protection Program (GWPP), at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12). This report formally documents well inspection events conducted on active and inactive wells at Y-12 during calendar years (CY) 2007 through 2009; it documents well maintenance and plugging and abandonment activities completed since the last triennial inspection event (CY 2006); and provides summary tables of well inspection events, well maintenance events, and well plugging and abandonment events during the reference time period.

54 ENVIRONMENTAL SCIENCES↗

Y-12 Groundwater Protection Program CY2012 Triennial Report Of The Monitoring Well Inspection And Maintenance Program Y-12 National Security Complex, Oak Ridge, Tennessee

This document is the triennial report for the Well Inspection and Maintenance Program of the Y- 12 Groundwater Protection Program (GWPP), at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12). This report formally documents well inspections completed by the GWPP on active and inactive wells at Y-12 during calendar years (CY) 2010 through 2012. In addition, this report also documents well inspections performed under the Y-12 Water Resources Restoration Program, which is administered by URS|CH2M Oak Ridge (UCOR). This report documents well maintenance activities completed since the last triennial inspection event (CY 2009); and provides summary tables of well inspections and well maintenance activities during the reference time period.

54 ENVIRONMENTAL SCIENCES↗

Y-12 Groundwater Protection Program Monitoring Optimization Plan For Groundwater Monitoring Wells At The U.S. Department Of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

This document is the monitoring optimization plan for groundwater monitoring wells associated with the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee. The plan describes the technical approach that is implemented under the Y-12 Groundwater Protection Program (GWPP) to focus available resources on the monitoring wells at Y-12 that provide the most useful hydrologic and groundwater quality monitoring data. The technical approach is based on the GWPP status designation for each well. Under this approach, wells granted "active" status are used by the GWPP for hydrologic monitoring and/or groundwater quality sampling, whereas wells granted "inactive" status are not used for either purpose. The status designation also defines the frequency at which the GWPP will inspect applicable wells, the scope of these well inspections, and extent of any maintenance actions initiated by the GWPP. Details regarding the ancillary activities associated with implementation of this plan (e.g., well inspection) are deferred to the referenced GWPP plans. This plan applies to groundwater wells associated with Y-12 and related waste management areas and facilities located within three hydrogeologic regimes.

54 ENVIRONMENTAL SCIENCES↗

Feasibility Study of Economics and Performance of Solar Photovoltaics at the Ft. Hood Military Base Outside Killeen, Texas - A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative through the Region 6 contract, selected Ft. Hood Army Base in Killeen, Texas, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) provided technical assistance for this project. The purpose of this study is to assess the site for possible photovoltaic (PV) system installations and estimate the cost, performance, and site impacts of different PV options. In addition, the report recommends financing options that could assist in the implementation of a PV system at the site.

14 SOLAR ENERGY↗

ESA Protection for the American Eel: Implications for US Hydropower

The American eel (Anguilla rostrata) has been proposed for special protection in the United States under the Endangered Species Act (ESA). This conservation action could impact a significant number of hydropower plants. A spatial analysis of data from Oak Ridge National Laboratory’s HydroGIS estimated that 32,719 MW of nameplate capacity is at risk at existing hydropower projects in the eastern United States. Most of these plants, with a combined capacity of 20,827 MW, are located in coastal river basins, and many of these occur in New England and Mid-Atlantic states. For eels, upstream passage is both effective and relatively inexpensive to provide. However, ensuring safe downstream passage presents significant challenges. Combinations of technologies for guiding and/or collecting large, maturing eels during their downstream migration through the hydro-system are still in the early stages of development. Several promising future directions emerged from our review. These included design of eel-friendly turbines, intake screens, and bypasses and strategic approaches to bypass multiple hydropower projects by trapping eels upstream and transporting them around dams. In this report, we review the state of the science in eel passage, including both upstream and downstream passage, where considerations include turbine impacts, and eel biology. We highlight promising avenues to guide future research and development efforts toward effective solutions that minimize impacts to hydropower production. From a broader geographic perspective, we recommend evaluating where the best opportunities for eel recovery exist. Unlike other fish species that migrate between freshwater and the ocean, juvenile eels do not necessarily return to one of the rivers occupied by their parents. This implies that the species will likely be managed as a single genetic stock, and efforts to avoid listing under ESA by preventing decline will be most effective if they are coordinated. By understanding the species’ biology, it should be possible to focus eel conservation efforts in river systems with reduced impact to US hydropower production.

Jager, Henriette (Yetta) I.↗

Data sharing report characterization of population 7: Personal protective equipment, dry active waste, and miscellaneous debris, surveillance and maintenance project Oak Ridge National Laboratory Oak Ridge, Tennessee

The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management (EM-OR) requested that Oak Ridge Associated Universities (ORAU), working under the Oak Ridge Institute for Science and Education (ORISE) contract, provide technical and independent waste management planning support under the American Recovery and Reinvestment Act (ARRA). Specifically, DOE EM-OR requested that ORAU plan and implement a sampling and analysis campaign targeting certain URS|CH2M Oak Ridge, LLC (UCOR) surveillance and maintenance (S&M) process inventory waste. Eight populations of historical and reoccurring S&M waste at the Oak Ridge National Laboratory (ORNL) have been identified in the Waste Handling Plan for Surveillance and Maintenance Activities at the Oak Ridge National Laboratory, DOE/OR/01-2565&D2 (WHP) (DOE 2012) for evaluation and processing to determine a final pathway for disposal. Population 7 (POP 7) consists of 56 containers of aged, low-level and potentially mixed S&M waste that has been staged in various locations around ORNL. Several of these POP 7 containers primarily contain personal protective equipment (PPE) and dry active waste (DAW), but may contain other miscellaneous debris. This data sharing report addresses the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) specified waste in a 13-container subpopulation (including eight steel boxes, three 55-gal drums, one sealand, and one intermodal) that lacked sufficient characterization data for possible disposal at the Environmental Management Waste Management Facility (EMWMF) using the approved Waste Lot (WL) 108.1 profile.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility Study of Economics and Performance of Solar Photovoltaics at the TechCity East Campus Resource Conservation and Recovery Act Site in Kingston, New York. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the TechCity East Campus site in Kingston, New York, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) provided technical assistance for this project. The purpose of this study is to assess the site for a possible photovoltaic (PV) system installation and estimate the cost, performance, and site impacts of different PV options. In addition, the report recommends financing options that could assist in the implementation of a PV system at the site.

14 SOLAR ENERGY↗

Evaluation on the Feasibility of Using Ultrasonic Testing of Reactor Pressure Vessel Welds for Assessing Flaw Density/Distribution per 10 CFR 50.61a, Alternate Fracture Toughness Requirements for Protection Against Pressurized Thermal Shock

This technical letter report provides the status of an assessment undertaken by PNNL at the request of the NRC to verify the capability of periodic ASME-required volumetric examinations of reactor vessels to characterize the density and distribution of flaws of interest for applying §50.61a on a plant-by-plant basis. The PTS rule, described in the Code of Federal Regulations, Title 10, Section 50.61 (§50.61), "Fracture Toughness Requirements for Protection against Pressurized Thermal Shock Events," establishes screening criteria to ensure that the potential for a reactor vessel to fail due to a PTS event is deemed to be acceptably low. Recently, the NRC completed a research program that concluded that the risk of through-wall cracking due to a PTS event is much lower than previously estimated. The NRC subsequently developed and promulgated an alternate PTS rule, §50.61a, that can be implemented by PWR licensees. The §50.61a rule differs from §50.61 in that it requires licensees who choose to follow this alternate method to analyze the results from periodic volumetric examinations required by the ASME Code, Section XI, Rules for Inservice Inspection (ISI) of Nuclear Power Plants.

alternate PTS rule↗

Summary Report for the Environmental Protection Agency MERL/FRMAC/RAP Mission Alignment Exercise held at the Savannah River Site on June 9-13 2014

From June 9th thru June 13th 2014, members of the Federal Radiological Monitoring and Assessment Center (FRMAC), the Environmental Protection Agency (EPA) and the Department of Energy Radiological Assistance Program (DOE RAP) Region-3 participated in a joint nuclear incident emergency response exercise at the Savannah River Site (SRS) near Aiken, South Carolina. The purpose of this exercise was to strengthen the interoperability relationship between the FRMAC, RAP, and the EPA Mobile Environmental Radiation Laboratory (MERL) stationed in Montgomery, Alabama. The exercise was designed to allowed members of the DOE RAP Region-3 team to collect soil, water, vegetation and air samples from SRS and submit them through an established FRMAC hotline. Once received and processed through the hotline, FRMAC delivered the samples to the EPA MERL for sample preparation and laboratory radiological analysis. Upon completion of laboratory analysis, data was reviewed and submitted back to FRMAC via an electronic data deliverable (EDD). As part of the exercise, an evaluation was conducted to identify gaps and potential improvements in each step of the processes. Additionally, noteworthy practices and potential future areas of interoperability between FRMAC and EPA were acknowledged. The exercise also provided a unique opportunity for FRMAC personnel to observe EPA sample receipt and sample preparation processes and to gain familiarity with the MERL laboratory instrumentation and radiation detection capabilities. The observations and lessons-learned from this exercise will be critical for developing a more efficient, integrated response for future interactions between the FRMAC and EPA assets.

54 ENVIRONMENTAL SCIENCES↗

RHIC Prefire Protection Masks

The protection of the RHIC experimental detectors from damage due to beam hitting close upstream elements in cases of abort kicker prefires requires some dedicated precautionary measures with two general options: to bring the beam close to a limiting aperture (i.e. the beam pipe wall), as far upstream of the detector components as possible or, alternatively, to bring a limiting aperture close to the circulating beam. During the FY 2014 RHIC Heavy Ion run the first option was chosen because of the limited time available for preparation before the start of the run. For future runs the second option, in this case the installation of dual-sided movable masks, is preferred. The installation of the masks, one per ring, is planned before the start of the FY 2015 run.

43 PARTICLE ACCELERATORS↗

Statistical Analysis of Demographic and Temporal Differences in LANL's 2014 Voluntary Protection Program Survey

Voluntary Protection Program (VPP) surveys were conducted in 2013 and 2014 to assess the degree to which workers at Los Alamos National Laboratory feel that their safety is valued by their management and peers. The goal of this analysis is to determine whether the difference between the VPP survey scores in 2013 and 2014 is significant, and to present the data in a way such that it can help identify either positive changes or potential opportunities for improvement. Data for several questions intended to identify the demographic groups of the respondent are included in both the 2013 and 2014 VPP survey results. These can be used to identify any significant differences among groups of employees as well as to identify any temporal trends in these cohorts.

99 GENERAL AND MISCELLANEOUS↗

Commercial Building Motor Protection Response Report

When voltages recover, motors may immediately reenergize and reaccelerate, or delay for a few minutes, or stay stalled. The estimated motor response is given for both the voltage sag magnitude and voltage sag duration. These response estimates are based on experience and available test data. Good data is available for voltage sag response for many components such as relays and contactors, but little data is available for both voltage sag and recovery response. The tables in Appendix A include data from recent voltage sag and recovery tests performed by SCE and BPA on air conditioners and energy management systems. The response of the motor can vary greatly depending on the type of protection and control. The time duration for the voltage sag consists of those times that are of interest for bulk power system modelers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutron Generator Production Facility (NGPF), Building 870: Structural Fire Protection Analysis and Basis of Design Report

This report was prepared to provide an explanation of the prescriptive-based code approach for the Neutron Generator Production Facility’s (NGPF) structural fire protection and construction classification determinations based upon the original code-of-record (1991-UBC) and current International Building Code (2012-IBC) requirements. The code approach presented in this report included a determination of the required construction type in accordance with the 2012-IBC. Through the evaluation of the record design drawings and subsequent site surveys, a determination was made of the existing types of materials used to construct the columns, beams, floor assemblies, roof assembly, and exterior and interior walls and partitions. A summary is provided for the fire resistance requirements of the different elements of the building. In addition, a determination was made in regards to the fire resistance hourly ratings of the columns, beams, floor assemblies, roof assembly, exterior walls, interiors walls and partitions, door openings, joints and penetrations. Through design evaluation, site survey, code verification, and review of record documents, the actual construction classification (Type II-B) was confirmed to be compliant with the 2012-IBC.

42 ENGINEERING↗

Thermodynamic Properties of Aqueous Carbonate Species and Solid Carbonate Phases of Selected Trace Elements pertinent to Drinking Water Standards of the U.S. Environmental Protection Agency

This report contains a series of tables summarizing the thermodynamic properties of aqueous carbonate complexes and solid carbonate phases of the following elements: arsenic (As), barium (Ba), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), manganese (Mn), mercury (Hg), nickel (Ni) thallium (Tl), uranium (U) and zinc (Zn). Most of these elements are potentially hazardous as defined by extant primary drinking water standards of the United States Environmental Protection Agency (EPA). The remainder are not considered hazardous, but are either listed by EPA under secondary standards, or because they can adversely affect drinking water quality. Additional tables are included giving the thermodynamic properties for carbonates of the alkali metal and alkali earth elements, sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), and strontium (Sr), because of their value in developing correlative models to estimate the thermodynamic properties of carbonate minerals for which no such data currently exist. The purpose in creating the tables in this report is to provide future investigators with a convenient source for selecting and tracing the sources of thermodynamic data of the above listed elements for use in modeling their geochemical behavior in “underground sources of drinking water” (USDW). The incentive for doing so lies with a heightened concern over the potential consequences of the proposed capture and storage of carbon dioxide (CO2) generated by fossil fuel fired power plants in deep subsurface reservoirs. If CO2 were to leak from such reservoirs, it could migrate upward and contaminate USDWs with undesirable, but undetermined, consequences to water quality. The EPA, Office of Research and Development, through an Interagency Agreement with the U.S. Department of Energy at the Lawrence Berkeley National Laboratory, funded the preparation of this report.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗