Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ranking methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

SU-F-R-24: Identifying Prognostic Imaging Biomarkers in Early Stage Lung Cancer Using Radiomics

Purpose: Patients diagnosed with early stage lung cancer have favorable outcomes when treated with surgery or stereotactic radiotherapy. However, a significant proportion (∼20%) of patients will develop metastatic disease and eventually die of the disease. The purpose of this work is to identify quantitative imaging biomarkers from CT for predicting overall survival in early stage lung cancer. Methods: In this institutional review board-approved HIPPA-compliant retrospective study, we retrospectively analyzed the diagnostic CT scans of 110 patients with early stage lung cancer. Data from 70 patients were used for training/discovery purposes, while those of remaining 40 patients were used for independent validation. We extracted 191 radiomic features, including statistical, histogram, morphological, and texture features. Cox proportional hazard regression model, coupled with the least absolute shrinkage and selection operator (LASSO), was used to predict overall survival based on the radiomic features. Results: The optimal prognostic model included three image features from the Law’s feature and wavelet texture. In the discovery cohort, this model achieved a concordance index or CI=0.67, and it separated the low-risk from high-risk groups in predicting overall survival (hazard ratio=2.72, log-rank p=0.007). In the independent validation cohort, this radiomic signature achieved a CI=0.62, and significantly stratified the low-risk and high-risk groups in terms of overall survival (hazard ratio=2.20, log-rank p=0.042). Conclusion: We identified CT imaging characteristics associated with overall survival in early stage lung cancer. If prospectively validated, this could potentially help identify high-risk patients who might benefit from adjuvant systemic therapy.

60 APPLIED LIFE SCIENCES↗

Unified many-worlds browsing of arbitrary physics-based animations

Manually tuning physics-based animation parameters to explore a simulation outcome space or achieve desired motion outcomes can be notoriously tedious. This problem has motivated many sophisticated and specialized optimization-based methods for fine-grained (keyframe) control, each of which are typically limited to specific animation phenomena, usually complicated, and, unfortunately, not widely used. In this paper, we propose Unified Many-Worlds Browsing (UMWB), a practical method for sample-level control and exploration of physics-based animations. Our approach supports browsing of large simulation ensembles of arbitrary animation phenomena by using a unified volumetric WORLDPACK representation based on spatiotemporally compressed voxel data associated with geometric occupancy and other low-fidelity animation state. Beyond memory reduction, the WORLDPACK representation also enables unified query support for interactive browsing: it provides fast evaluation of approximate spatiotemporal queries, such as occupancy tests that find ensemble samples ("worlds") where material is either IN or NOT IN a user-specified spacetime region. WORLDPACKS also support real-time hardware-accelerated voxel rendering by exploiting the spatially hierarchical and temporal RLE raster data structure. Our UMWB implementation supports interactive browsing (and offline refinement) of ensembles containing thousands of simulation samples, and fast spatiotemporal queries and ranking. We show UMWB results using a wide variety of physics-based animation phenomena---not just JELL-O ® .

Computer Science↗

5-Fluorouracil induced liver toxicity in patients with colorectal cancer: role of computed tomography texture analysis as a potential biomarker

Purpose: To assess if CT texture analysis (TA) can serve as a biomarker of liver toxicity in patients with colorectal cancer treated with 5-fluorouracil (5-FU)-based chemotherapy. Methods: In this IRB-approved, HIPAA-compliant retrospective study, patients with colorectal cancer treated with 5-FU-based regimens during 2008–2010 were identified from institutional electronic database. Total 43 patients (23 women; mean age 56 years) with normal baseline liver function tests (LFTs), availability of baseline (pre-chemotherapy) and first follow-up CT (median 1.7 months, interquartile range (IQR) 1.5–2.5) performed during chemotherapy were included. Two single-slice ROI of right and left liver lobe were obtained on baseline and first follow-up CT for TA. Texture features [mean, entropy, kurtosis, skewness, mean of positive pixel, standard deviation (SD)] were extracted using a commercially available software (TexRAD; Feedback Medical Ltd, Cambridge, UK). Changes in texture parameters between baseline and follow-up CT were evaluated with Wilcoxon signed-rank test for patients with and without LFT elevation during chemotherapy. Results: Patients with LFT elevation (n = 34; 79%) showed significantly different mean, entropy, skewness, and SD (p values range 0.007–0.047) between baseline and first follow-up CT. No significant changes in features were observed in patients without LFT elevation (n = 9; 21%). In 19 patients (56%), first follow-up CT was performed before elevation of LFTs was observed. Conclusions: This proof-of-concept study shows that there are early changes in liver texture on first follow-up CT in patients with LFT elevation during 5-FU-based chemotherapy for colorectal cancer. In more than 50% of cases, these changes occur before LFT elevation becomes evident on blood tests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting kinase inhibitors using bioactivity matrix derived informer sets

Prediction of compounds that are active against a desired biological target is a common step in drug discovery efforts. Virtual screening methods seek some active-enriched fraction of a library for experimental testing. Where data are too scarce to train supervised learning models for compound prioritization, initial screening must provide the necessary data. Commonly, such an initial library is selected on the basis of chemical diversity by some pseudo-random process (for example, the first few plates of a larger library) or by selecting an entire smaller library. These approaches may not produce a sufficient number or diversity of actives. An alternative approach is to select an informer set of screening compounds on the basis of chemogenomic information from previous testing of compounds against a large number of targets. We compare different ways of using chemogenomic data to choose a small informer set of compounds based on previously measured bioactivity data. We develop this Informer-Based-Ranking (IBR) approach using the Published Kinase Inhibitor Sets (PKIS) as the chemogenomic data to select the informer sets. We test the informer compounds on a target that is not part of the chemogenomic data, then predict the activity of the remaining compounds based on the experimental informer data and the chemogenomic data. Through new chemical screening experiments, we demonstrate the utility of IBR strategies in a prospective test on three kinase targets not included in the PKIS.

59 BASIC BIOLOGICAL SCIENCES↗

Canopy Cover Predictions using Ground Observations and Remotely Sensed Data

Maps of vegetation status are needed at many scales, from the field level to monitor ecosystem condition to the global level to understand the carbon cycle. Status is quantified by such variables as leaf area index, biomass, and fraction of canopy cover. Current methods of predicting vegetation variables use remote sensing data to provide a spatially exhaustive data source. In a study in western Montana, several hundred ground observations made by the US Forest Service on tenth-acre conifer plots were used to develop aspatial regression and geostatistical prediction models. Normalized Difference Vegetation Index (NDVI) values from Landsat Thematic Mapper images were used as ancillary data. These models were then used to predict canopy cover at unsampled locations in a 97 square kilometer region on the boundary of the Flathead National Forest and the Bob Marshall Wilderness. Independent data from two dates six years apart were used for validation. Given the assumption that actual canopy cover remained relatively unchanged within this time period, partial validation can be achieved by measuring the correspondence of the two maps. This criterion results in ranking the aspatial regression maps as less accurate than the geostatistically generated maps. The geostatistical approach emphasizes ground measurements more heavily than does aspatid regression. Geostatistical simulations of canopy cover also provide a means of describing uncertainty about the patterns of canopy cover.

Dungan, Jennifer L.↗

LPV Modeling of a Flexible Wing Aircraft Using Modal Alignment and Adaptive Gridding Methods

One of the earliest approaches in gain-scheduling control is the gridding based approach, in which a set of local linear time-invariant models are obtained at various gridded points corresponding to the varying parameters within the flight envelop. In order to ensure smooth and effective Linear Parameter-Varying control, aligning all the flexible modes within each local model and maintaining small number of representative local models over the gridded parameter space are crucial. In addition, since the flexible structural models tend to have large dimensions, a tractable model reduction process is necessary. In this paper, the notion of s-shifted H2- and H Infinity-norm are introduced and used as a metric to measure the model mismatch. A new modal alignment algorithm is developed which utilizes the defined metric for aligning all the local models over the entire gridded parameter space. Furthermore, an Adaptive Grid Step Size Determination algorithm is developed to minimize the number of local models required to represent the gridded parameter space. For model reduction, we propose to utilize the concept of Composite Modal Cost Analysis, through which the collective contribution of each flexible mode is computed and ranked. Therefore, a reduced-order model is constructed by retaining only those modes with significant contribution. The NASA Generic Transport Model operating at various flight speeds is studied for verification purpose, and the analysis and simulation results demonstrate the effectiveness of the proposed modeling approach.

LPV Modeling↗

SU-E-J-260: Quantitative Image Feature Analysis of Multiphase Liver CT for Hepatocellular Carcinoma (HCC) in Radiation Therapy

Purpose: To identify the effective quantitative image features (radiomics features) for prediction of response, survival, recurrence and metastasis of hepatocellular carcinoma (HCC) in radiotherapy. Methods: Multiphase contrast enhanced liver CT images were acquired in 16 patients with HCC on pre and post radiation therapy (RT). In this study, arterial phase CT images were selected to analyze the effectiveness of image features for the prediction of treatment outcome of HCC to RT. Response evaluated by RECIST criteria, survival, local recurrence (LR), distant metastasis (DM) and liver metastasis (LM) were examined. A radiation oncologist manually delineated the tumor and normal liver on pre and post CT scans, respectively. Quantitative image features were extracted to characterize the intensity distribution (n=8), spatial patterns (texture, n=36), and shape (n=16) of the tumor and liver, respectively. Moreover, differences between pre and post image features were calculated (n=120). A total of 360 features were extracted and then analyzed by unpaired student’s t-test to rank the effectiveness of features for the prediction of response. Results: The five most effective features were selected for prediction of each outcome. Significant predictors for tumor response and survival are changes in tumor shape (Second Major Axes Length, p= 0.002; Eccentricity, p=0.0002), for LR, liver texture (Standard Deviation (SD) of High Grey Level Run Emphasis and SD of Entropy, both p=0.005) on pre and post CT images, for DM, tumor texture (SD of Entropy, p=0.01) on pre CT image and for LM, liver (Mean of Cluster Shade, p=0.004) and tumor texture (SD of Entropy, p=0.006) on pre CT image. Intensity distribution features were not significant (p>0.09). Conclusion: Quantitative CT image features were found to be potential predictors of the five endpoints of HCC in RT. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

A study of transfer of UNF from non-disposable canisters - 15388

A study was performed by AREVA and URS for the Department of Energy (DOE) [1] to establish optimal methods for the opening of dry storage canisters (DSC) and the subsequent repackaging of used nuclear fuel (UNF) from the DSCs into generic standard transportation, aging, and disposal canisters (STADs) in wet or dry environments at reactor, consolidated storage, or repository sites. Eight dry and wet cutting technologies were evaluated: (1) skiving; (2) milling; (3) arc gouging/plasma torch; (4) cutting wheel; (5) diamond cable cutting; (6) laser cutting; (7) sawing; and (8) electrical discharge machining. The evaluated UNF repackaging technologies options included: (1) wet transfer in a pool; (2) dry transfer in a dry transfer system (DTS); (3) dry transfer in a fixed hot cell (FHC); (4) dry transfer in a mobile hot cell (MHC), and (5) a hybrid approach utilizing wet transfer in a pool and dry transfer in a FHC. A systems engineering evaluation was utilized for ranking the eight viable cutting options and the five different repackaging approaches for each of the sites. The systems engineering evaluation took into account six criteria (i.e., life cycle costs, worker dose, operational efficiency, technical maturity, ease of licensing, and waste generation) and performed a qualitative pairwise ranking of their relative importance to one another. Then quantitative or qualitative factors associated with each criterion (e.g., cost in millions of dollars, relative ease of licensing, etc.) for each option at each location (reactor, consolidated storage facility [CSF], repository) were developed based on historical experience, existing design studies, current 'state-of-the art', and/or engineering judgment. Using this input, the systems engineering evaluation identified dry skiving as the preferred cutting technology, with the wheel cutting technology in either a dry or wet environment identified as a promising technology that, with some RD and D, could mature to a better option (depending also on the disposition of the used DSC). For a reactor and a CSF/repository site, the systems engineering evaluation ranked the repackaging option using the skiving dry cutting technique and wet transfer of UNF in a pool as the highest option. However for a CSF and a repository site, the team recommended the hybrid option using the skiving dry cutting technique and both dry and wet transfer of UNF in a pool and FHC as a potentially better option (providing specific benefits such as higher throughput and more flexibility in operation). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-E-T-294: Dosimetric Analysis of Planning Phase Using Overlap Volume Histogram for Respiratory Gated Radiotherapy

Purpose: End-of-exhale (EOE) phase is generally preferred for gating window because tumor position is more reproducible. However, other gating windows might be more appropriate for dose distribution perspective. In this pilot study, we proposed to utilize overlap volume histogram (OVH) to search optimized gating window and demonstrated its feasibility. Methods: We acquired 4DCT of 10 phases for 3 lung patients (2 with a target at right middle lobe and 1 at right upper lobe). After structures were defined in every phase, the OVH of each OAR was generated to quantify the three dimensional spatial relationship between the PTV and OARs (bronchus, esophagus, heart and cord etc.) at each phase. OVH tells the overlap volume of an OAR according to outward distance from the PTV. Relative overlap volume at 20 mm outward distance from the PTV (ROV-20) was also defined as a metric for measuring overlap volume and obtained. For dose calculation, 3D CRT plans were made for all phases under the same beam angles and objectives (e.g., 95% of the PTV coverage with at least 100% of the prescription dose of 50 Gy). The gating window phase was ranked according to ROV-20, and the relationship between the OVH and dose distribution at each phase was evaluated by comparing the maximum dose, mean dose, and equivalent uniform dose of OAR. Results: OVHs showed noticeable difference from phase to phase, implying it is possible to find optimal phases for gating window. For 2 out of 3 patients (both with a target at RML), maximum dose, mean dose, and EUD increased as ROV-20 increased. Conclusion: It is demonstrated that optimal phases (in dose distribution perspective) for gating window could exist and OVH can be a useful tool for determining such phases without performing dose optimization calculations in all phases. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2012-007883) through the National Research Foundation (NRF) funded by the Ministry of Science, ICT & Future Planning (MSIP) of Korea.

60 APPLIED LIFE SCIENCES↗

A Parametric Geometry Computational Fluid Dynamics (CFD) Study Utilizing Design of Experiments (DOE)

Design of Experiments (DOE) techniques were applied to the Launch Abort System (LAS) of the NASA Crew Exploration Vehicle (CEV) parametric geometry Computational Fluid Dynamics (CFD) study to efficiently identify and rank the primary contributors to the integrated drag over the vehicles ascent trajectory. Typical approaches to these types of activities involve developing all possible combinations of geometries changing one variable at a time, analyzing them with CFD, and predicting the main effects on an aerodynamic parameter, which in this application is integrated drag. The original plan for the LAS study team was to generate and analyze more than1000 geometry configurations to study 7 geometric parameters. By utilizing DOE techniques the number of geometries was strategically reduced to 84. In addition, critical information on interaction effects among the geometric factors were identified that would not have been possible with the traditional technique. Therefore, the study was performed in less time and provided more information on the geometric main effects and interactions impacting drag generated by the LAS. This paper discusses the methods utilized to develop the experimental design, execution, and data analysis.

Rhew, Ray D.↗

Radiotherapy Is Associated With Improved Survival in Adjuvant and Palliative Treatment of Extrahepatic Cholangiocarcinomas

Purpose: Extrahepatic cholangiocarcinomas (EHC) are rare tumors of the biliary tree because of their low incidence, large randomized studies examining radiotherapy (RT) for EHC have not been performed. The purpose of this study was to examine the role of adjuvant and palliative RT in the treatment of EHC in a large patient population. Methods and Materials: This was a retrospective analysis of 4,758 patients with EHC collected from the Surveillance, Epidemiology, and End Results database. The primary endpoint was overall survival. Results: Patients underwent surgery (28.8%), RT (10.0%), surgery and RT (14.7%), or no RT or surgery (46.4%). The median age of the patient population was 73 years (range, 23-104), 52.5% were men, and 80.7% were white. The median overall survival time was 16 months (95% confidence interval [CI] 15-17), 9 months (95% CI 9-11), 9 months (95% CI 9-10), and 4 months (95% CI 3-4) for surgery and RT, surgery, RT, and no RT or surgery, respectively. The overall survival was significantly different between the surgery and surgery and RT groups (p < .0001) and RT and no RT or surgery groups (p < .0001) on the log-rank test. The propensity score-adjusted analyses of surgery and RT vs. surgery (hazard ratio, 0.94; 95% CI, 0.84-1.05) were not significantly different, but that for RT vs. no RT or surgery (hazard ratio, 0.61; 95% CI, 0.54-0.70) was significantly different. Conclusion: These results suggest that palliative RT prolongs survival in patients with EHC. The benefit associated with surgery and RT was significant on univariate analysis but not after controlling for potential confounders using the propensity score. Future studies should evaluate the addition of chemotherapy and biologic agents for the treatment of EHC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3-Dimensional Magnetic Resonance Spectroscopic Imaging at 3 Tesla for Early Response Assessment of Glioblastoma Patients During External Beam Radiation Therapy

Purpose: To evaluate the utility of 3-dimensional magnetic resonance (3D-MR) proton spectroscopic imaging for treatment planning and its implications for early response assessment in glioblastoma multiforme. Methods and Materials: Eighteen patients with newly diagnosed, histologically confirmed glioblastoma had 3D-MR proton spectroscopic imaging (MRSI) along with T2 and T1 gadolinium-enhanced MR images at simulation and at boost treatment planning after 17 to 20 fractions of radiation therapy. All patients received standard radiation therapy (RT) with concurrent temozolomide followed by adjuvant temozolomide. Imaging for response assessment consisted of MR scans every 2 months. Progression-free survival was defined by the criteria of MacDonald et al. MRSI images obtained at initial simulation were analyzed for choline/N-acetylaspartate ratios (Cho/NAA) on a voxel-by-voxel basis with abnormal activity defined as Cho/NAA ≥2. These images were compared on anatomically matched MRSI data collected after 3 weeks of RT. Changes in Cho/NAA between pretherapy and third-week RT scans were tested using Wilcoxon matched-pairs signed rank tests and correlated with progression-free survival, radiation dose and location of recurrence using Cox proportional hazards regression. Results: After a median follow-up time of 8.6 months, 50% of patients had experienced progression based on imaging. Patients with a decreased or stable mean or median Cho/NAA values had less risk of progression (P<.01). Patients with an increase in mean or median Cho/NAA values at the third-week RT scan had a significantly greater chance of early progression (P<.01). An increased Cho/NAA at the third-week MRSI scan carried a hazard ratio of 2.72 (95% confidence interval, 1.10-6.71; P=.03). Most patients received the prescription dose of RT to the Cho/NAA ≥2 volume, where recurrence most often occurred. Conclusion: Change in mean and median Cho/NAA detected at 3 weeks was a significant predictor of early progression. The potential impact for risk-adaptive therapy based on early spectroscopic findings is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy

Purpose: Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. Methods: A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantry angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman’s rank correlation coefficients (r{sub s}) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MI{sub SPORT}) were calculated, and their correlations were analyzed in the same way. Results: There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The r{sub s} values of contrast to the global gamma passing rates with criteria of 2%/2 mm, 2%/1 mm, and 1%/2 mm were 0.536, 0.473, and 0.718, respectively. The respective values for variance were 0.551, 0.481, and 0.688. In the case of local gamma passing rates, the r{sub s} values of contrast were 0.547, 0.578, and 0.620, respectively, and those of variance were 0.519, 0.527, and 0.569. All of the r{sub s} values in those cases were statistically significant (p < 0.003). In the cases of global and local gamma passing rates, MI{sub SPORT} showed the highest correlations among the conventional modulation indices. For global passing rates, r{sub s} values of MI{sub SPORT} were −0.420, −0.330, and −0.632, respectively, and those for local passing rates were −0.455, −0.490 and −0.502. The values of r{sub s} of contrast, variance, and MI{sub SPORT} with the MLC errors were −0.863, −0.828, and 0.795, respectively, all with statistical significances (p < 0.001). The correlations with statistical significances between variance and dose-volumetric differences were observed more frequently than the others. Conclusions: The contrast (d = 1) and variance (d = 1) calculated from fluence maps of VMAT plans showed considerable correlations with the plan deliverability, indicating their potential use as indicators for assessing the degree of modulation of VMAT plans. Both contrast and variance consistently showed better performance than the conventional modulation indices for VMAT.

60 APPLIED LIFE SCIENCES↗

Structure and Reactivity of Low-Rank Coal Chars Prepared from Fluidized Bed and Moving Bed Pyrolyzers and the Potential for Using Them in Pulverized Coal Injection (PCI)

Utilizing pyrolysis chars as the injection fuel in a blast furnace can reduce the dependence on high-quality pulverized coal injection (PCI) coal. In this study, the physical properties and reaction characteristics of chars prepared from two different industrial-scale pyrolyzers (fluidized bed and moving bed) are investigated. The results reveal remarkable component segregation in the char particles with different particle sizes. The properties of large-size char particles are found to better satisfy the PCI fuel requirement in a blast furnace. Compared with PCI coal, the char particles exhibit a rough surface, well-developed pore structure, and less-ordered chemical structure of carbon. Results from isothermal combustion, isothermal gasification, and drop tube furnace experiments show that both types of chars exhibit a better reactivity than PCI coal. The excellent reactivity of chars is closely related to its high Brunauer–Emmett–Teller surface area and relatively poor chemical ordering during conversion. Based on these characteristics, both fluidized bed char (FBC) and moving bed char (MBC) have a great potential to be used as PCI fuels. The application method of chars for PCI in a blast furnace is proposed finally.

01 COAL, LIGNITE, AND PEAT↗

WE-AB-207B-08: Exploring and Refining the QUANTEC Guideline to Reduce Severe Hyposalivation Following IMRT for Head and Neck Cancer

Purpose: The aim of this study was to investigate the usefulness of the QUANTEC guideline to prevent xerostomia after intensity-modulated radiotherapy (IMRT) for head and neck cancer (HNC) with respect to follow-up time. In addition, we explored alternative guidelines to further reduce xerostomia. Methods: The QUANTEC guideline suggests a mean dose to the contralateral (Dmeancontra) parotid<20 Gy, or Dmeancontra and Dmean to the ipsilateral parotid (Dmeanipsi)<25 Gy. Stimulated whole mouth saliva flow measurements (WMSFM) were conducted at a median of 11 (3–24) months for 63 patients treated with IMRT for HNC to a median dose of 70 Gy in 2006–2015. Severe hyposalivation/xerostomia was defined as WMSFM ≤25% post- relative to pre-RT. Patients were stratified into a <6m (xerostomia: 27% (n=15)), and a 6–24m (xerostomia: 19% (n=10)) follow-up group. Dose-response modeling was performed using logistic regression including Dmeancontra, or Dmeancontra and Dmeanipsi. The area under the receiver-operating characteristics curve (AUC) was used to assess discriminative ability, and the agreement between the estimated and observed rate of xerostomia was given by Spearman’s rank correlation coefficient (Rs), and related p-values. Results: Of the non-xerostomia patients, 65% (<6m) and 56% (6–24m) fulfilled Dmeancontra<20 Gy. The estimated and observed rate of xerostomia agreed at <6m (AUC=0.78; Rs=0.46; p=0.001), and was 28% at Dmeancontra=20 Gy. A smaller number of non-xerostomia patients fulfilled the two-gland guideline (33% (<6m) and 26% (6–24m)), but the AUC was higher than using Dmeancontra only (<6m: AUC=0.90; Rs=0.63; p<0.0001; 6–24m: AUC=0.84; Rs=0.25; p=0.08), and the following amendment of the two-gland guideline was suggested: (0.17*Dmeancontra+0.11*Dmeanipsi-8.13)<-1.60 (<6m), and (0.05*Dmeancontra+0.02*Dmeanipsi-3.10)<-1.60 (6–24m). Conclusion: The QUANTEC guideline is effective to prevent xerostomia <6m post-RT, but its usefulness is reduced at later follow-up times. The suggested amendment to the two-gland QUANTEC guideline should be further investigated in an independent cohort of HNC patients treated with IMRT.

60 APPLIED LIFE SCIENCES↗

classLog: Logistic regression for the classification of genetic sequences

Introduction Sequencing and phylogenetic classification have become a common task in human and animal diagnostic laboratories. It is routine to sequence pathogens to identify genetic variations of diagnostic significance and to use these data in realtime genomic contact tracing and surveillance. Under this paradigm, unprecedented volumes of data are generated that require rapid analysis to provide meaningful inference. Methods We present a machine learning logistic regression pipeline that can assign classifications to genetic sequence data. The pipeline implements an intuitive and customizable approach to developing a trained prediction model that runs in linear time complexity, generating accurate output rapidly, even with incomplete data. Our approach was benchmarked against porcine respiratory and reproductive syndrome virus (PRRSv) and swine H1 influenza A virus (IAV) datasets. Trained classifiers were tested against sequences and simulated datasets that artificially degraded sequence quality at 0, 10, 20, 30, and 40%. Results When applied to a poor-quality sequence data, the classifier achieved between >85% to 95% accuracy for the PRRSv and the swine H1 IAV HA dataset and this increased to near perfect accuracy when using the full dataset. The model also identifies amino acid positions used to determine genetic clade identity through a feature selection ranking within the model. These positions can be mapped onto a maximum-likelihood phylogenetic tree, allowing for the inference of clade defining mutations. Discussion Our approach is implemented as a python package with code available at https://github.com/flu-crew/classLog .

Zeller, Michael A.↗