Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Time-Dependent Failure Assessment of Ceramic Receivers

The outlet temperature targets for Gen 3 Concentrating Solar Power (CSP) systems pose a significant challenge to the structural reliability of high temperature metallic components, including those manufactured from nickel-based superalloys. Advanced ceramics present a potential solution due to their excellent high-temperature strength. However, accurate assessment of ceramic components requires an entirely different approach compared to metallic components. This paper describes the implementation of time-dependent reliability analysis of ceramic components in srlife – an open-source software package for estimating the life of high temperature CSP components. This new capability will allow high temperature CSP designers to make fair comparisons between competing metallic and ceramic designs and accurately assess the performance of different ceramic materials for CSP receivers and other components. The current version of the tool is available at https://github.com/Argonne-National-Laboratory/srlife.

Barua, Bipul (ORCID:0000000247184113)↗

FY11 Facility Assessment Study for Aeronautics Test Program

This paper presents the approach and results for the Aeronautics Test Program (ATP) FY11 Facility Assessment Project. ATP commissioned assessments in FY07 and FY11 to aid in the understanding of the current condition and reliability of its facilities and their ability to meet current and future (five year horizon) test requirements. The principle output of the assessment was a database of facility unique, prioritized investments projects with budgetary cost estimates. This database was also used to identify trends for the condition of facility systems.

Loboda, John A.↗

Efficient marine environmental characterisation to support monitoring of geological CO 2 storage

Carbon capture and storage is key for mitigating greenhouse gas emissions, and offshore geological formations provide vast CO 2 storage potential. Monitoring of sub-seabed CO 2 storage sites requires that anomalies signifying a loss of containment be detected, and if attributed to storage, quantified and their impact assessed. However, monitoring at or above the seabed is only useful if one can reliably differentiate abnormal signals from natural variability. Baseline acquisition is the default option for describing the natural state, however we argue that a comprehensive baseline assessment is likely expensive and time-bound, given the multi-decadal nature of CCS operations and the dynamic heterogeneity of the marine environment. We present an outline of the elements comprising an efficient marine environmental baseline to support offshore monitoring. We demonstrate that many of these elements can be derived from pre-existing and ongoing sources, not necessarily related to CCS project development. We argue that a sufficient baseline can be achieved by identifying key emergent properties of the system rather than assembling an extensive description of the physical, chemical and biological states. Further, that contemporary comparisons between impacted and non-impacted sites are likely to be as valuable as before and after comparisons. Furthermore, as these emergent properties may be nuanced between sites and seasons and comparative studies need to be validated by the careful choice of reference site, a site-specific understanding of the scales of heterogeneity will be an invaluable component of a baseline.

54 ENVIRONMENTAL SCIENCES↗

Determination of Thermoelectric Module Efficiency A Survey

The development of thermoelectrics (TE) for energy conversion is in the transition phase from laboratory research to device development. There is an increasing demand to accurately determine the module efficiency, especially for the power generation mode. For many thermoelectrics, the figure of merit, ZT, of the material sometimes cannot be fully realized at the device level. Reliable efficiency testing of thermoelectric modules is important to assess the device ZT and provide the end-users with realistic values on how much power can be generated under specific conditions. We conducted a general survey of efficiency testing devices and their performance. The results indicated the lack of industry standards and test procedures. This study included a commercial test system and several laboratory systems. Most systems are based on the heat flow meter method and some are based on the Harman method. They are usually reproducible in evaluating thermoelectric modules. However, cross-checking among different systems often showed large errors that are likely caused by unaccounted heat loss and thermal resistance. Efficiency testing is an important area for the thermoelectric community to focus on. A follow-up international standardization effort is planned.

efficiency↗

Use of Cardiac Imaging to Evaluate Cardiac Function and Pulmonary Hemodynamics in Patients with Heart Failure

Purpose of Review: Noninvasive hemodynamic assessments in patients with heart failure (HF) are essential for appropriate diagnosis and establishment of the best treatment strategies. Recently, the impact of pulmonary circulation and right ventricular function on prognosis in HF patients has drawn increasing attention. In this article, we explore the usefulness of cardiac imaging for hemodynamic assessments, mainly focusing on echocardiographic evaluation. Recent Findings: The reliability of Doppler echocardiography as a noninvasive alternative to Swan-Ganz catheterization has been well investigated with higher than 80% accuracy for estimating pulmonary artery pressure. Strain measurement and three-dimensional echocardiography are useful for evaluating right ventricular function together with pulmonary circulation. The accuracy of analyzing left and right ventricular functions by cardiac computed tomography and cardiac magnetic resonate imaging has also been established. These modalities can provide myocardial tissue information and allow calculation of the extracellular volume fraction as well. Summary: According to the rapid improvement of technologies, cardiac imaging has become an essential tool for hemodynamic evaluation in HF management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling and experimental assessment of a buried Leu–Ile mutation in dengue envelope domain III

Envelope protein domain III (ED3) of the dengue virus is important for both antibody binding and host cell interaction. Here, we focused on how a L387I mutation in the protein core could take place in DEN4 ED3, but cannot be accommodated in DEN3 ED3 without destabilizing its structure. To this end, we modeled a DEN4-L387I structure using the Penultimate Rotamer Library and taking the DEN4 ED3 main-chain as a fixed template. We found that three out of seven Ile{sup 387} conformers fit in DEN4 ED3 without introducing the severe atomic clashes that are observed when DEN3 serotype’s ED3 is used as a template. A more extensive search using 273 side-chain rotamers of the residues surrounding Ile{sup 387} confirmed this prediction. In order to assess the prediction, we determined the crystal structure of DEN4-L387I at 2 Å resolution. Ile{sup 387} indeed adopted one of the three predicted rotamers. Altogether, this study demonstrates that the effects of single mutations are to a large extent successfully predicted by systematically modeling the side-chain structures of the mutated as well as those of its surrounding residues using fixed main-chain structures and assessing inter-atomic steric clashes. More accurate and reliable predictions require considering sub-angstrom main-chain deformation, which remains a challenging task. - Highlights: • We mutated L387I of DEN4 ED3 and examined its effects on structure and stability. • We modeled the side-chain of Ile{sup 387} using DEN4 ED3's structure as a template. • We determined the crystal structure of DEN4-L387I and confirmed the modeling. • Side-chain repacking occurring around Ile{sup 387} involved >3 inter-connected residues. • These results explained why L387I mutation in DEN4 ED3 conserves thermostability.

60 APPLIED LIFE SCIENCES↗

Dependence of predicted bulk properties of hexagonal hydroxyapatite on exchange-correlation functional

Hydroxyapatite (HA) is the main component of human bones and teeth. HA has also been widely applied in various technological fields due to its unique properties. Reliable computational simulations for this critical material often require input parameters obtained from the first-principles density functional theory (DFT) calculations with appropriate exchange–correlation functionals. Previous DFT calculations are insufficient to verify the reliabilities of various functionals, particularly as they fail to assess predictions for multiple properties of the material. In this paper, we first select 18 different functionals to calculate geometric, elastic, electronic, and thermodynamic properties of hexagonal HA bulk crystal. We find that the results from optB86b-vdW and optB88-vdW functionals with dispersion corrections have the overall best agreement with available experimental data. Then, we choose optB88-vdW functional, as well as PBE functional without dispersion corrections as a comparison, to perform extensive first-principles DFT phonon calculations under the quasiharmonic approximation. Various thermodynamic properties (including phonon contributions to internal energy, entropy, and Helmholtz free energy) and thermal parameters (including thermal expansions of volume, thermal expansion coefficients, heat capacities, isothermal bulk moduli, etc.) versus temperature are consequently obtained. By comparing these quantities, we report that the results from optB88-vdW functional have significantly better agreement with available experimental data than those from PBE functional although the latter has been widely used in previous DFT calculations for HA-based material systems.

36 MATERIALS SCIENCE↗

Evaluating hydrogen permeation through medium-density and high-density polyethylene pipes to enable a hydrogen-compatible infrastructure

As the United States and the global community pursue energy abundance and resilience, hydrogen is becoming a critical energy carrier. The future of hydrogen transport depends on one thing: verifying that today’s pipelines are hydrogen ready. This study investigates the permeation behavior of medium-density polyethylene (MDPE) and high-density polyethylene (HDPE) pipelines under pure hydrogen gas environment at various pressures and temperatures. Using thermal desorption analysis (TDA) and direct pipe permeability measurements, hydrogen loss rates are quantified, revealing minimal permeation losses (< 10.5 g/km/day) under realistic operating conditions. Effects of temperature and pressure with Standard Dimension Ratios (SDR), were evaluated to determine their influence on permeation rates of MDPE and HDPE pipelines. In addition, ex-situ density and degree of crystallinity (DOC) of MDPE and HDPEs after hydrogen exposure were also investigated to understand pressure-dependency of polymer properties. The findings provide essential data for assessing polymer-based pipeline materials for safe and reliable hydrogen transport.

08 HYDROGEN↗

A call to standardize metrics for monitoring baleen whales near marine construction activities

Effective monitoring is necessary to protect marine mammal species during the construction of offshore infrastructure. The tools for detecting or monitoring marine mammals span traditional (e.g., visual observers, optical cameras), to newer (e.g., passive acoustic monitoring, infrared cameras, tags), and emerging (e.g., satellite imagery, environmental DNA, dimethyl sulfide concentration) technologies. Some are better suited for use during offshore development; however, peer-reviewed literature does not typically evaluate and report on the performance of these various technologies. We define a minimum set of metrics related to efficacy (i.e., confusion matrix, precision and recall, probability of missed mitigation), detection range (i.e., maximum and reliable detection range, spatial resolution), and data delivery (i.e., detection latency, system reliability, temporal resolution) that we recommend are needed to assess the utility of monitoring technologies for this purpose. Following a literature review of relevant studies, we highlight which publications reported these metrics and used multiple technologies to compare relative performance. We also emphasize the benefits of multi-modal approaches and recommend performance assessments through modeling or large-scale collaborative field testing. These metrics will standardize data collection, reporting, and analysis; promote consistent and comparable results; and foster collaboration among developers, regulatory agencies, and scientists. This may lead to the co-development of technology that achieves multiple goals, has greater application, and can answer research questions while collecting data to fulfill permitting requirements. These metrics may also inform decisions on what systems regulatory agencies might consider using and reduce monitoring costs, which is critical to support the marine sector's rapid growth alongside marine mammal conservation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comprehensive assessment of metrology techniques for heliostat efficiency and performance evaluation

Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.

14 SOLAR ENERGY↗

General Multifidelity Surrogate Models: Framework and Active-Learning Strategies for Efficient Rare Event Simulation

Estimating the probability of failure for complex real-world systems using high-fidelity computational models is often prohibitively expensive, especially when the probability is small. Exploiting low-fidelity models can make this process more feasible, but merging information from multiple low-fidelity and high-fidelity models poses several challenges. Here, this paper presents a robust multi-fidelity surrogate modeling strategy in which the multi-fidelity surrogate is assembled using an active learning strategy using an on-the-fly model adequacy assessment set within a subset simulation framework for efficient reliability analysis. The multi-fidelity surrogate is assembled by first applying a Gaussian process correction to each low-fidelity model and assigning a model probability based on the model's local predictive accuracy and cost. Three strategies are proposed to fuse these individual surrogates into an overall surrogate model based on model averaging and deterministic/stochastic model selection. The strategies also dictate which model evaluations are necessary. No assumptions are made about the relationships between low-fidelity models, while the high-fidelity model is assumed to be the most accurate and most computationally expensive model. Through two analytical and two numerical case studies, including a case study evaluating the failure probability of Tristructural isotropic-coated (TRISO) nuclear fuels, the algorithm is shown to be highly accurate while drastically reducing the number of high-fidelity model calls (and hence computational cost).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Oxide thickness dependence of swift heavy ion-induced surface tracks formation in silicon dioxide on silicon structures at grazing incidence

The influence of the oxide thickness in the surface tracks formation in thin silicon dioxide layered-silicon substrate (SiO{sub 2}-Si) irradiated with swift heavy ion is dealt with. In this respect, SiO{sub 2}-Si samples with different oxide thicknesses have been characterized using atomic force microscopy before and after 7.51 MeV/u Xe ion irradiation at a grazing incident angle of 1 deg. relative to the surface plane. Experimental evidence of the existence of a threshold thickness in the formation of swift heavy ion-induced surface tracks has been addressed and discussed according to the thermal spike theory. This experimental upshot can be helpful when assessing metal-oxide-semiconductor ultrathin-gate oxide reliability issues and for growth of silicon-based nanostructures.

36 MATERIALS SCIENCE↗

High voltage stability performance of a gamma ray detection device

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing the accuracy of high-dimensional neural network potentials and the systematic molecular fragmentation method: A benchmark study for all-trans alkanes

Many approaches, which have been developed to express the potential energy of large systems, exploit the locality of the atomic interactions. A prominent example is the fragmentation methods in which the quantum chemical calculations are carried out for overlapping small fragments of a given molecule that are then combined in a second step to yield the system’s total energy. Here we compare the accuracy of the systematic molecular fragmentation approach with the performance of high-dimensional neural network (HDNN) potentials introduced by Behler and Parrinello. HDNN potentials are similar in spirit to the fragmentation approach in that the total energy is constructed as a sum of environment-dependent atomic energies, which are derived indirectly from electronic structure calculations. As a benchmark set, we use all-trans alkanes containing up to eleven carbon atoms at the coupled cluster level of theory. These molecules have been chosen because they allow to extrapolate reliable reference energies for very long chains, enabling an assessment of the energies obtained by both methods for alkanes including up to 10 000 carbon atoms. We find that both methods predict high-quality energies with the HDNN potentials yielding smaller errors with respect to the coupled cluster reference.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-AB-207A-03: A CBCT Head Scanner for Point-Of-Care Imaging of Intracranial Hemorrhage

Purpose: This work reports the design, development, and first technical assessment of a cone-beam CT (CBCT) scanner developed specifically for imaging of acute intracranial hemorrhage (ICH) at the point of care, with target applications in diagnosis and monitoring of traumatic brain injury, stroke, and postsurgical hemorrhage. Methods: System design employed a task-based image quality model to quantify the influence of factors such as additive noise and high-gain (HG) detector readout on ICH detectability. Three bowtie filters with varying bare-beam attenuation strength and curvature were designed to enable HG readout without detector saturation, and a polyenergetic gain correction was developed to minimize artifacts from bowtie flood-field calibration. Image reconstruction used an iterative penalized weighted least squares (PWLS) method with artifact correction including Monte Carlo scatter estimation, Joseph-Spital beam hardening correction, and spatiotemporal deconvolution of detector glare and lag. Radiation dose was characterized for half-scan and full-scan protocols at various kV, and imaging performance was assessed in a head phantom presenting simulated ICH with diameter ranging 2–12 mm. Results: The image quality model guided system design and was validated by measurements on a CBCT imaging bench. Compared to low-gain readout without a bowtie filter, the combination of HG readout and a modest bowtie improved the contrast-to-noise ratio (CNR per unit square-root dose) by 20% in the center of the image but degraded noise performance near the periphery (20% reduction in CNR). Low-frequency bowtie artifacts (∼100 HU magnitude) were corrected by the polyenergetic gain correction. Image reconstructions on the prototype scanner demonstrate clear visibility of the smallest ICH insert (2 mm diameter) in both HG readout (with a bowtie) and dual-gain readout (without bowtie). Conclusion: Technical assessment of the prototype scanner suggests the capability for reliable visualization of small (2 mm), low-contrast (50 HU) ICH at <20 mGy dose and motivates translation to clinical studies, now underway. Xiaohui Wang and David Foos (co-authors) are employees of Carestream Health. Research funding support from Carestream Health.

60 APPLIED LIFE SCIENCES↗

Regulation of Yeast-to-Hyphae Transition in Yarrowia lipolytica

Many yeasts undergo a morphological transition from yeast-to-hyphal growth in response to environmental conditions. We used forward and reverse genetic techniques to identify genes regulating this transition in Yarrowia lipolytica . We confirmed that the transcription factor Yl msn2 is required for the transition to hyphal growth and found that signaling by the histidine kinases Yl chk1 and Yl nik1 as well as the MAP kinases of the HOG pathway (Yl ssk2 , Yl pbs2 , and Yl hog1 ) regulates the transition to hyphal growth. These results suggest that Y. lipolytica transitions to hyphal growth in response to stress through multiple kinase pathways. Intriguingly, we found that a repetitive portion of the genome containing telomere-like and rDNA repeats may be involved in the transition to hyphal growth, suggesting a link between this region and the general stress response.

59 BASIC BIOLOGICAL SCIENCES↗

An integrated approach for the in vitro dosimetry of engineered nanomaterials

Background: There is a great need for screening tools capable of rapidly assessing nanomaterial toxicity. One impediment to the development of reliable in vitro screening methods is the need for accurate measures of cellular dose. We present here a methodology that enables accurate determination of delivered to cell dose metrics. This methodology includes (1) standardization of engineered nanomaterial (ENM) suspension reparation; (2) measurement of ENM characteristics controlling delivery to cells in culture; and (3) calculation of delivered dose as a function of exposure time using the ISDD model. The approach is validated against experimentally measured doses, and simplified analytical expressions for the delivered dose (Relevant In Vitro Dose (RID)f function) are derived for 20 ENMs. These functions can be used by nanotoxicologists to accurately calculate the total mass (RIDM), surface area (RIDSA), or particle number (RIDN) delivered to cells as a function of exposure time. Results: The proposed methodology was used to derive the effective density, agglomerate diameter and RID functions for 17 industrially-relevant metal and metal oxide ENMs, two carbonaceous nanoparticles, and non-agglomerating gold nanospheres, for two well plate configurations (96 and 384 well plates). For agglomerating ENMs, the measured effective density was on average 60% below the material density. We report great variability in delivered dose metrics, with some materials depositing within 24 hours while others require over 100 hours for delivery to cells. A neutron-activated tracer particle system was employed to validate the proposed in vitro dosimetry methodology for a number of ENMs (measured delivered to cell dose within 9% of estimated). Conclusions: Our findings confirm and extend experimental and computational evidence that agglomerate characteristics affect the dose delivered to cells. Therefore measurement of these characteristics is critical for effective use of in vitro systems for nanotoxicology. The mixed experimental/computational approach to cellular dosimetry proposed and validated here can be used by nanotoxicologists to accurately calculate the delivered to cell dose metrics for various ENMs and in vitro conditions as a function of exposure time. The RID functions and characterization data for widely used ENMs presented here can together be used by experimentalists to design and interpret toxicity studies.

Cohen, J.↗