Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Characterization of Senecavirus A Isolates Collected From the Environment of U.S. Sow Slaughter Plants

Vesicular disease caused by Senecavirus A (SVA) is clinically indistinguishable from foot-and-mouth disease (FMD) and other vesicular diseases of swine. When a vesicle is observed in FMD-free countries, a costly and time-consuming foreign animal disease investigation (FADI) is performed to rule out FMD. Recently, there has been an increase in the number of FADIs and SVA positive samples at slaughter plants in the U.S. The objectives of this investigation were to: (1) describe the environmental burden of SVA in sow slaughter plants; (2) determine whether there was a correlation between PCR diagnostics, virus isolation (VI), and swine bioassay results; and (3) phylogenetically characterize the genetic diversity of contemporary SVA isolates. Environmental swabs were collected from three sow slaughter plants (Plants 1-3) and one market-weight slaughter plant (Plant 4) between June to December 2020. Of the 426 samples taken from Plants 1-3, 304 samples were PCR positive and 107 were VI positive. There was no detection of SVA by PCR or VI at Plant 4. SVA positive samples were most frequently found in the summer (78.3% June-September, vs. 59.4% October-December), with a peak at 85% in August. Eighteen PCR positive environmental samples with a range of C t values were selected for a swine bioassay: a single sample infected piglets ( n = 2). A random subset of the PCR positive samples was sequenced; and phylogenetic analysis demonstrated co-circulation and divergence of two genetically distinct groups of SVA. These data demonstrate that SVA was frequently found in the environment of sow slaughter plants, but environmental persistence and diagnostic detection was not indicative of whether a sampled was infectious to swine. Consequently, a more detailed understanding of the epidemiology of SVA and its environmental persistence in the marketing chain is necessary to reduce the number of FADIs and aide in the development of control measures to reduce the spread of SVA.

59 BASIC BIOLOGICAL SCIENCES↗

Atom probe tomography analysis of the reference Zircon GJ-1: An interlaboratory study

In recent years, atom probe tomography (APT) has been increasingly used to study minerals, and in particular the mineral zircon. Zircon (ZrSiO 4 ) is ideally suited for geochronology by utilising the U-Th-Pb isotope systems, and trace element compositions are also widely used to constrain petrogenetic processes. However, while standard geoanalytical techniques provide information at micron scale lengths, the unique combination of chemical/isotopic sensitivity and spatial resolution of APT allows compositional and textural measurements at the nanoscale. This round robin study aims to define the reproducibility of APT data across research facilities and assess the role of different aspects of the atom probe workflow on reproducibility. This is essential to allow correct evaluation of APT results and full utilization of this emerging technique within the geoscience community. In this study, nine samples from the same homogemeous, GJ-1/87 zircon reference grain were sent to nine APT institutes in Europe, USA, Canada and Australia. Each institute conducted three different rounds of APT analyses: using (i) unconstrained analysis parameters, [1] pre-defined analysis parameters, and (iii) a data analysis exercise. Data such as the measured composition, acquisition parameters, or mass spectrum peak identifications, were recorded and analyzed. We observe a significant variation in the measured composition across this round robin study as well as the number of trace elements identified. These differences are thought to directly result from the user's choice of peak identification, ranging and background correction model. The type of instrument does not seem to be a critical factor. Consequently, comparison of absolute trace element data on zircon using APT between laboratories is only valid if the same workflow has been ensured.

round robin, atom probe tomography, reference zirc↗

Target-specific optimization of four-dimensional cone beam computed tomography

Purpose: Under-sampling artifacts are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) and may compromise evaluation of target motion. Several studies have addressed scan parameter selection for minimizing under-sampling artifacts; however, the role of the target characteristics in scan parameter selection has not been investigated. In this work, the authors evaluated 4D-CBCT performance by assessing the accuracy of target motion measurements for various target sizes and motions. The results may serve as patient-specific guidelines for scan parameters selection in 4D-CBCT. Methods: The authors acquired 4D-CBCT scans of a moving phantom consisting of six water-filled sphere targets of sizes 10-37 mm, using various scan times ranging from 30 s to 3 min., setting the motion to 3-s and 6-s periods. The authors used automatic image registration to extract the target motion trajectories and evaluated these measurements for various target sizes and motions over various combinations of scan parameters including scan time, detector configuration, number of respiration phases, and reconstruction filters. Results: The most important object parameter to 4D-CBCT performance was the period of motion. Measurements for the 6-s motion were always systematically less accurate than measurements for the 3-s motion for 34 of 36 objects of various sizes and periods of motion. The 6-s motion required a greater scan time than the 3-s motion for equivalent measurement accuracy. The second most influential parameter was the target size. For the 3-s period of motion, objects larger than 13 mm were tracked with sub-millimeter accuracy with a 1-min scan time. For the 6-s period of motion, objects larger than 22-mm were tracked with sub-millimeter accuracy with a 1.5-min scan time. For all sizes and motions, temporal blurring was observed when the number of phases was fewer than 8. Offset detector configuration provided the same performance as centered detector except for small targets (20 mm.) at short scan times ({<=}1 min). Finally, reconstruction filtering and number of respiratory phases did not affect performance. Conclusions: Scan time should be set according to target size and motion. The authors have provided figures that provide the minimum scan time needed to achieve the particular motion measurement accuracy for a particular size and motion period.

60 APPLIED LIFE SCIENCES↗

Methods for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry

A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE z = 5 QUASAR LUMINOSITY FUNCTION FROM SDSS STRIPE 82

We present a measurement of the Type I quasar luminosity function at z = 5 using a large sample of spectroscopically confirmed quasars selected from optical imaging data. We measure the bright end (M{sub 1450} < -26) with Sloan Digital Sky Survey (SDSS) data covering {approx}6000 deg{sup 2}, then extend to lower luminosities (M{sub 1450} < -24) with newly discovered, faint z {approx} 5 quasars selected from 235 deg{sup 2} of deep, coadded imaging in the SDSS Stripe 82 region (the celestial equator in the Southern Galactic Cap). The faint sample includes 14 quasars with spectra obtained as ancillary science targets in the SDSS-III Baryon Oscillation Spectroscopic Survey, and 59 quasars observed at the MMT and Magellan telescopes. We construct a well-defined sample of 4.7 < z < 5.1 quasars that is highly complete, with 73 spectroscopic identifications out of 92 candidates. Our color selection method is also highly efficient: of the 73 spectra obtained, 71 are high-redshift quasars. These observations reach below the break in the luminosity function (M{sub 1450}{sup *}{approx}-27). The bright-end slope is steep ({beta} {approx}< -4), with a constraint of {beta} < -3.1 at 95% confidence. The break luminosity appears to evolve strongly at high redshift, providing an explanation for the flattening of the bright-end slope reported previously. We find a factor of {approx}2 greater decrease in the number density of luminous quasars (M{sub 1450} < -26) from z = 5 to z = 6 than from z = 4 to z = 5, suggesting a more rapid decline in quasar activity at high redshift than found in previous surveys. Our model for the quasar luminosity function predicts that quasars generate {approx}30% of the ionizing photons required to keep hydrogen in the universe ionized at z = 5.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigations of Association Among Atmospheric Radionuclide Measurements

Large networks producing frequent atmospheric radionuclide measurements have additional power in characterizing and localizing radionuclide release events over the analysis done with four or fewer samples. However, adding unrelated samples to an analysis dilutes that advantage, unless models are extended to account for this complexity. A key steppingstone to obtaining network power is to select a group of related sample measurements that are associated with a release event. Such collections of measurements can be assembled by an analyst, or perhaps they can be selected by algorithm. The authors explore, using a year of atmospheric transport calculations and realistic sensor sensitivities, the potential for a computed radionuclide association tool.

Eslinger, Paul W.↗

Distinguishing the importance of fullerene phase separation from polymer ordering in the performance of low band gap polymer: Bis-fullerene heterojunctions

It is known, one way to improve power conversion efficiency (PCE) of polymer based bulk-heterojunction (BHJ) photovoltaic cells is to increase the open circuit voltage (V oc ). Replacing PCBM with bis-adduct fullerenes significantly improves V oc and the PCE in devices based on the conjugated polymer poly(3-hexyl thiophene) (P3HT). However, for the most promising low band-gap polymer (LBP) system, replacing PCBM with ICBA results in poor short-circuit current (J sc ) and PCE although V oc is significantly improved. The optimization of the morphology of as-cast LBP/bis-fullerene BHJ photovoltaics is attempted by adding a co-solvent to the polymer/fullerene solution prior to film deposition. Varying the solubility of polymer and fullerene in the co-solvent, bulk heterojunctions are fabricated with no change of polymer ordering, but with changes in fullerene phase separation. The morphologies of the as-cast samples are characterized by small angle neutron scattering and neutron reflectometry. A homogenous dispersion of ICBA in LBP is found in the samples where the co-solvent is selective to the polymer, giving poor device performance. Aggregates of ICBA are formed in samples where the co-solvent is selective to ICBA. Furthermore, the resultant morphology improves PCE by up to 246%. Finally, a quantitative analysis of the neutron data shows that the interfacial area between ICBA aggregates and its surrounding matrix is improved, facilitating charge transport and improving the PCE.

30 DIRECT ENERGY CONVERSION↗

Enhanced biofilm formation aids adaptation to extreme warming and environmental instability in the diatom Thalassiosira pseudonana and its associated bacteria

Abstract Recent studies have highlighted the capacity of marine diatoms at the foundation of ocean food webs and biogeochemical cycles to respond to environmental change. These responses are a combination of physiological acclimation and evolutionary responses. The latter occur rapidly within a few hundred generations (translating to a scale of months to years), due to the large standing genetic variation and short generation times of diatom populations. Studies are usually carried out on diatom species in their planktonic state, but this may constitute a stark oversimplification: diatoms readily form biofilms in the water column of shallow coastal areas, where biofilm formation affects carbon export, and in the benthos, where biofilms contribute significantly to sediment stability. Here, I have carried out a 400‐generation selection experiment, where I evolved the diatom Thalassiosira pseudonana and its associated bacteria. Bacteria and diatom were cultured in their planktonic form, and under strong selection for rapid biofilm formation in temperature and nutrient regimes differing in their severity and stability. I find that biofilm formation is enhanced under mild warming and rapid thermal fluctuations but not under extreme warming regardless of nutrient availability. Evolutionary responses are slower in biofilms under benign conditions but speed up under extreme and fluctuating conditions. Taxonomic composition of the associated bacteria is driven by the temperature selection regime in biofilms but not in planktonic samples. I also show that T. pseudonana , when selected for biofilm formation, presents predictable and sequential morphologies that are not usually observed in planktonic T. pseudonana.

Schaum, C. ‐E.↗

Structural and Dielectric Properties of Rare Earth Doped Lithium Nanoferrites for Sensing Applications

Nowadays it is the hot topic to analyze the behavior of different materials towards gasses so that they can be used for sensing purpose. Ferrites specifically lithium ferrites show very good response to gasses present in the environment. Lithium ferrite doped with Gd (Li{sub 0.5}Fe{sub 2.475}Gd{sub 0.025}O{sub 4}) was selected for this purpose. Sample was synthesized by simplified sol-gel technique. After that, pellets were formed and sintered at different temperatures. Spinel cubic phase was observed in x-ray diffraction (XRD). It is noted that by increasing sintering temperature, results slightly decrease in lattice constant. Scanning electron microscopy (SEM) was used to study the surface morphology of the samples. It was observed that particles were spherical in shape. AC electrical properties were studied at room temperature in the frequency range of 20 Hz to 3 MHz. AC electrical conductivity and dielectric constant decreased with the increase in sintering temperature. The maximum conductivity was observed in the sample that was sintered at temperature of 700 {sup ∘}C. Significant variation in electrical response with frequency made these samples suitable for sensing applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Representativeness-Based Sampling Network Design for the State of Alaska

Resource and logistical constraints limit the frequency and extent of environmental observations, particularly in the Arctic, necessitating the development of a systematic sampling strategy to maximize coverage and objectively represent environmental variability at desired scales. A quantitative methodology for stratifying sampling domains, informing site selection, and determining the representativeness of measurement sites and networks is described here.

Hoffman, Forrest M↗

Measuring Gas Transport and Sorption in Large Intact Geologic Specimens via the Piezometric Method

Uptake of noble gases into heterogeneous geologic core samples was measured using a piezometric methodology. In addition to measuring accessible porosity—as with gas pycnometry—by monitoring the rate of pressure decay, this method can also be used to estimate the gas effective diffusivity in the sample. In contrast to previous applications of this method, where milligram quantities of fractured grains are characterized, here approximately kilogram core samples were left intact when tested. In doing so, a more representative sample of the heterogeneous field geology is provided. Additionally, alteration of the pore structure and connectivity during sample preparation is avoided. Furthermore, to scale the piezometric method from milligrams to kilograms, the system was designed to operate at medium vacuum (1 to 100 Pa) to restrict transport in pores less than approximately 60 µm to large Knudsen numbers. To test the system performance, two samples of interest were selected: a rhyolitic welded tuff from Blue Canyon Dome at the Energetic Materials Research and Testing Center and a zeolitized non-welded rhyolitic tuff from the Nevada National Security Site. Three noble gases were utilized in this test series; Argon and xenon as they are of direct interest to nuclear monitoring efforts and helium as it is a weakly adsorbing reference standard. Additionally, mercury intrusion porosimetry measurements were made on subsamples of the core to compare the observed porosity by the two methods and to discuss gas transport rates in the context of the measured pore distribution.

58 GEOSCIENCES↗

Oxidation Resistance of Ti-Al-Cr-Nb-Based High-Entropy Alloys in Air at 1073 K

The effects of prolonged exposure to air at 1073 K on Al20Cr25Nb20Ti20Zr15 and Al20Cr25Nb19Ti20Zr15Y1 (at.%) high-entropy alloys (HEAs) were investigated in this work. Combined scanning electron microscopy and energy-dispersive x-ray spectroscopy (SEM–EDS) analysis revealed that scales containing all major elements in the systems are formed during the oxidation process. Thermogravimetric analysis carried out under the above-mentioned corrosive conditions indicates an initial parabolic kinetics course in the case of the sample with 1 at.% Y addition. However, after a certain period of time, the correlation between mass gain per unit surface area and time becomes linear. In the other case, oxidation proceeds according to the parabolic rate law for the entire process duration. The addition of 1 at.% Y decreases the parabolic rate constants by 1 order of magnitude, thereby improving the chemical stability of the studied Al-Cr-Nb-Ti-Zr system. This is confirmed by visual evaluation, as well as SEM–EDS cross-sectional analysis. Additionally, x-ray diffraction studies indicate that a multiphase oxide scale is formed on the metallic core of both samples. This means that selective oxidation does not occur and all constituent elements took part in the reaction. Taking all of the above into account, it can be concluded that more research is required to fully understand and improve the corrosion resistance of Ti-Al-Cr-Nb-based HEAs.

36 MATERIALS SCIENCE↗

Automatic and rapid calibration of urban building energy models by learning from energy performance database

Urban building energy modeling (UBEM) is attracting increasing attention in the energy modeling filed. Unlike modeling a single building using detailed building systems information, UBEM generally uses limited high-level building stock data to infer default assumptions about building characteristics and operations. Additionally, this practice inherently brings uncertainty to UBEM. This study introduced a novel method of automatic and rapid calibration of UBEM based on the annual electricity and natural gas energy use data by learning the correlations between crucial model input parameters and the building energy use from the reference building models. A case study was presented to calibrate 72 large office buildings built before 1978 in San Francisco. Seventeen model parameters were selected and Monte Carlo sampling was used to create 1000 samples that reasonably represent the parameter space. Then 1000 simulations were performed for the reference building model to create an energy performance database. The results showed that by learning from the energy performance database, it took less than four simulation runs on average to calibrate a building model. After the calibration, the distributions of each parameter were obtained to replace their single predefined default values. For example, the default lighting power density of 21.39 W/m 2 was calibrated to be 7.50 W/m 2 on average. The case study successfully demonstrated the effectiveness of the novel calibration method for UBEM in the mild climate. The method will be further tested in future for other climate zones and other building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracing fetal and childhood exposure to lead using isotope analysis of deciduous teeth

We report progress in using the isotopic composition and concentration of Pb in the dentine and enamel of deciduous teeth to provide a high resolution time frame of exposure to Pb during fetal development and early childhood. Isotope measurements (total Pb and {sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb ratios) were acquired by laser ablation inductively coupled mass spectrometry at contiguous 100 micron intervals across thin sections of the teeth; from the outer enamel surface to the pulp cavity. Teeth samples (n=10) were selected from two cohorts of children, aged 5–8 years, living in NE England. By integrating the isotope data with histological analysis of the teeth, using the daily incremental lines in dentine, we were able to assign true estimated ages to each ablation point (first 2–3 years for molars, first 1–2 years for incisors+pre-natal growth). Significant differences were observed in the isotope composition and concentration of Pb between children, reflecting differences in the timing and sources of exposure during early childhood. Those born in 2000, after the withdrawal of leaded petrol in 1999, have the lowest dentine Pb levels (<0.2 µg Pb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.126–2.079) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.879–0.856) ratios that correlate very closely with modern day Western European industrial aerosols (PM{sub 10}, PM{sub 2.5}) suggesting that diffuse airborne pollution was probably the primary source and exposure pathway. Legacy lead, if present, is insignificant. For those born in 1997, dentine lead levels are typically higher (>0.4 µgPb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.145–2.117) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.898–0.882) ratios that can be modelled as a binary mix between industrial aerosols and leaded petrol emissions. Short duration, high intensity exposure events (1–2 months) were readily identified, together with evidence that dentine provides a good proxy for childhood changes in the isotope composition of blood Pb. Our pilot study confirms that laser ablation Pb isotope analysis of deciduous teeth, when carried out in conjunction with histological analysis, permits a reconstruction of the timing, duration and source of exposure to Pb during early childhood. With further development, this approach has the potential to study larger cohorts and appraise environments where the levels of exposure to Pb are much higher. - Highlights: • Reconstructing a high resolution chronology of early childhood exposure to lead. • Combined laser ablation lead isotope – histological analysis of children's teeth. • Using dentine to recover information on the intensity, duration and source of lead. • Importance of industrial airborne lead pollution in a post-leaded petrol era.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Risk of Radiation-Induced Malignancy With Heterotopic Ossification Prophylaxis: A Case–Control Analysis

Purpose: To determine the risk of radiation-induced malignancy after prophylactic treatment for heterotopic ossification (HO). Methods and Materials: A matched case–control study was conducted within a population-based cohort of 3489 patients treated either for acetabular fractures with acetabular open reduction internal fixation or who underwent total hip arthroplasty from 1990 to 2009. Record-linkage techniques identified patients who were diagnosed with a malignancy from our state health registry. Patients with a prior history of malignancy were excluded from the cohort. For each documented case of cancer, 2 controls were selected by stratified random sampling from the cohort that did not develop a malignancy. Matching factors were sex, age at time of hip treatment, and duration of follow-up. Results: A total of 243 patients were diagnosed with a malignancy after hip treatment. Five patients were excluded owing to inadequate follow-up time in the corresponding control cohort. A cohort of 238 cases (control, 476 patients) was included. Mean follow-up was 10 years, 12 years in the control group. In the cancer cohort, 4% of patients had radiation therapy (RT), compared with 7% in the control group. Of the 9 patients diagnosed with cancer after RT, none occurred within the field. The mean latency period was 5.9 years in the patients who received RT and 6.6 years in the patients who did not. Median (range) age at time of cancer diagnosis in patients who received RT was 62 (43-75) years, compared with 70 (32-92) years in the non-RT patients. An ad hoc analysis was subsequently performed in all 2749 patients who were not matched and found neither an increased incidence of malignancy nor a difference in distribution of type of malignancy. Conclusion: We were unable to demonstrate an increased risk of malignancy in patients who were treated with RT for HO prophylaxis compared with those who were not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Environmental fate of radiocesium in biota inhabiting a contaminated ecosystem on the U.S. Department of Energy's Savannah River Site

Although biomagnification of radiocesium ( 137 Cs) has been reported in food webs, most previous research has been limited to select trophic linkages. Few studies have included a comprehensive survey of fauna associated with aquatic, semi-aquatic, and terrestrial habitats within a single study framework. The objectives of this study were to advance our understanding of the dynamics of 137 Cs accumulation within food webs by quantifying 137 Cs activity across a wide range of biota found within a contaminated canal, as well as test the hypothesis that life-stage and body size influence 137 Cs bioaccumulation in select herpetofauna. With extensive sampling across multiple taxa collected from a contaminated canal system and associated floodplain on the Savannah River Site, we assessed 137 Cs activity and stable nitrogen isotopes for both aquatic organisms that were restricted to the contaminated effluent canal, and semi-aquatic organisms able to move freely between the contaminated canal and the adjacent uncontaminated terrestrial habitat. We found 137 Cs activity to be highly variable among species, with evidence for and against biomagnification in semi-aquatic and aquatic organisms, respectively. Furthermore, 137 Cs activity decreased with life stage and body size in bullfrogs (Lithobates catesbeianus), despite post-metamorphic bullfrogs having a more carnivorous diet compared to tadpoles, while cottonmouths (Agkistrodon piscivorus) retained similar 137 Cs activity regardless of their age and size. While evidence of biomagnification has been observed in some contaminated systems, results of our study suggest the extent to which 137 Cs biomagnifies within food webs is context-dependent and likely influenced by a suite of biotic and abiotic factors. Further, our data indicate sampling of a broad suite of species and environmental attributes are needed to elucidate the fate and dynamics of anthropogenic pollutants within contaminated ecosystems.

54 ENVIRONMENTAL SCIENCES↗

An integrated approach to examine fuel-cladding chemical interaction in HT9/U-10Zr metallic fast reactor fuels: Coupling machine learning with electron microscopy and local mechanical properties analysis

The metallic U-Zr nuclear fuel alloy has garnered renewed interest as a promising candidate for next-generation sodium-cooled fast reactors. Recent studies and technology assessments have identified several areas requiring improvements, enhanced knowledge, and reliable data to strengthen the U-Zr fuel design basis for qualification and commercial applications. One of the most challenging phenomena impacting this fuel system’s performance is fuel-cladding chemical interaction (FCCI). This work aimed to harvest FCCI data by examining selected HT9/U-10Zr (wt. %) fuel samples of prototypic full-length fuel pins through an integrated approach. This approach integrated scanning electron microscopy (SEM) microstructure characterization with localized mechanical properties examination to deepen understanding of FCCI phenomenon in HT9/U-10Zr fuel system. Particularly, this study focused on MFF fuel pins irradiated at Fast Flux Test Facility (FFTF), which aimed to qualify metallic fuel as a driver fuel for FFTF and to assess its viability for larger-scale fast reactors. Electron microscopy provided high confidence in detecting and distinguishing the different FCCI layers, while small-scale mechanical testing (SSMT) probed the mechanical properties of these layers. SEM examination of a MFF-2 pin 192167, with a time averaged inner cladding temperature (TICT) slightly over 500°C, revealed minimal cladding-side FCCI (cladding wastage). In contrast, significantly thicker cladding wastage comprising two distinct sublayers was observed in samples from the thermally hot MFF-3 pin 193045 and MFF-5 pin 195011 where the TICT ranged from 610-635°C. SSMT indicated complete embrittlement in the sublayer adjacent to the fuel and a tendency toward embrittlement in the other sublayer. Additionally, a new machine learning method was developed, validated, and used to quantify cladding wastage thickness. The machine learning method reliably predicted the wastage thickness across various fuel pins and sample cross-sections. Furthermore, the available cladding wastage data from HT9/U-10Zr fuel system demonstrated a strong temperature dependency. However, the dataset remains small, and ongoing research activities are essential to further understand the FCCI phenomenon and develop a reliable FCCI model for enhanced fuel performance simulation under various conditions.

36 - MATERIALS SCIENCE↗