Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures

Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the dump valve on these two appliances would have eliminated uncertainty in knowing when waste water was flowing and the recovery system operated. The study also suggested that capture of dryer exhaust heat to heat incoming air to the dryer should be examined as an alternative to using drying exhaust energy for water heating. The study found that over a 6-week test period, the system in each house was able to recover on average approximately 3000 W-h of waste heat daily from these appliance and showers with slightly less on simulated weekdays and slightly more on simulated weekends which were heavy wash/dry days. Most of these energy savings were due to the shower/GFX operation, and the least savings were for the dishwasher/GFX operation. Overall, the value of the 3000 W-h of displaced energy would have been $0.27/day based on an electricity price of $.09/kWh. Although small for today s convention house, these savings are significant for a home designed to approach maximum affordable efficiency where daily operating costs for the whole house are less than a dollar per day. In 2010 the actual measured cost of energy in one of the simulated occupancy houses which waste heat recovery testing was undertaken was $0.77/day.

Tomlinson, John J.↗

Boron-10 Lined Proportional Counter Model Validation

The decreasing supply of 3He is stimulating a search for alternative neutron detectors; one potential 3He replacement is 10B-lined proportional counters. Simulations are being performed to predict the performance of systems designed with 10B-lined tubes. Boron-10-lined tubes are challenging to model accurately because the neutron capture material is not the same as the signal generating material. Thus, to simulate the efficiency, the neutron capture reaction products that escape the lining and enter the signal generating fill gas must be tracked. The tube lining thickness and composition are typically proprietary vendor information, and therefore add additional variables to the system simulation. The modeling methodologies used to predict the neutron detection efficiency of 10B-lined proportional counters were validated by comparing simulated to measured results. The measurements were made with a 252Cf source positioned at several distances from a moderated 2.54-cm diameter 10B-lined tube. Models were constructed of the experimental configurations using the Monte Carlo transport code MCNPX, which is capable of tracking the reaction products from the (n,10B) reaction. Several different lining thicknesses and compositions were simulated for comparison with the measured data. This paper presents the results of the evaluation of the experimental and simulated data, and a summary of how the different linings affect the performance of a coincidence counter configuration designed with 10B-lined proportional counters.

Lintereur, Azaree T.↗

Histopomorphic Evaluation of Radiofrequency Mediated Débridement Chondroplasty

The use of radiofrequency devices has become widespread for surgical ablation procedures. When ablation devices have been deployed in treatment settings requiring tissue preservation like débridement chondroplasty, adoption has been limited due to the collateral damage caused by these devices in healthy tissue surrounding the treatment site. Ex vivo radiofrequency mediated débridement chondroplasty was performed on osteochondral specimens demonstrating surface fibrillation obtained from patients undergoing knee total joint replacement. Three radiofrequency systems designed to perform débridement chondroplasty were tested each demonstrating different energy delivery methods: monopolar ablation, bipolar ablation, and non-ablation energy. Treatment outcomes were compared with control specimens as to clinical endpoint and histopomorphic characteristics. Fibrillated cartilage was removed in all specimens; however, the residual tissue remaining at the treatment site displayed significantly different characteristics attributable to radiofrequency energy delivery method. Systems that delivered ablation-based energies caused tissue necrosis and collateral damage at the treatment site including corruption of cartilage Superficial and Transitional Zones; whereas, the non-ablation system created a smooth articular surface with Superficial Zone maintenance and without chondrocyte death or tissue necrosis. The mechanism of radiofrequency energy deposition upon tissues is particularly important in treatment settings requiring tissue preservation. Ablation-based device systems can cause a worsened state of articular cartilage from that of pre-treatment. Non-ablation energy can be successful in modifying/preconditioning tissue during débridement chondroplasty without causing collateral damage. Utilizing a non-ablation radiofrequency system provides the ability to perform successful débridement chondroplasty without causing additional articular cartilage tissue damage and may allow for other cartilage intervention success.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium Loaded Glass Fiber Neutron Detector Tests

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world and, thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of the lithium-loaded glass fibers option. This testing measured the neutron detection efficiency and gamma ray rejection capabilities of a small system manufactured by Nucsafe (Oak Ridge, TN).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generic and ML Workloads in an HPC Datacenter: Node Energy, Job Failures, and Node-Job Analysis

HPC datacenters offer a backbone to the modern digital society. Increasingly, they run Machine Learning (ML) jobs next to generic, compute-intensive workloads, supporting science, business, and other decision-making processes. However, understanding how ML jobs impact the operation of HPC datacenters, relative to generic jobs, remains desirable but understudied. In this work, we leverage long-term operational data, collected from a national-scale production HPC datacenter, and statistically compare how ML and generic jobs can impact the performance, failures, resource utilization, and energy consumption of HPC datacenters. Our study provides key insights, e.g., ML-related power usage causes GPU nodes to run into temperature limitations, median/mean runtime and failure rates are higher for ML jobs than for generic jobs, both ML and generic jobs exhibit highly variable arrival processes and resource demands, significant amounts of energy are spent on unsuccessfully terminating jobs, and concurrent jobs tend to terminate in the same state. We open-source our cleaned-up data traces on Zenodo (https://doi. org/10.5281/zenodo.13685426), and provide our analysis toolkit as software hosted on GitHub (https://github.com/atlarge-research/2024-icpads-hpc-workload-characterization). This study offers multiple benefits for data center administrators, who can improve operational efficiency, and for researchers, who can further improve system designs, scheduling techniques, etc.

crossanalysis↗

Distributed Solar PV for Electricity System Resiliency: Policy and Regulatory Considerations (Brochure)

Distributed Solar PV systems have the potential of increasing the grid's resiliency to unforeseen events, such as extreme weather events and attacks. This paper presents the role that distributed PV can play in electric grid resiliency, introduces basic system design requirements and options, and discusses the regulatory and policy options for supporting the use of distributed PV for the purpose of increased electricity resiliency.

14 SOLAR ENERGY↗

Conveyor technology rolls ahead to keep pace with industry demands

New drives, belts and rolling components maintain capacity but require less energy and maintenance. Computer-assisted component design and system modelling are becoming standard in improving conveyors for transporting ores, pellets or coal in open-cast mines. Continental Conveyor, for example, uses Statix modelling software to analyze existing conveyor systems and design new ones. Sandvik Materials Handling uses discrete element modelling. Developments by the major manufacturers including Veyance Technologies, Hagglunds Drives, and TPKL complings in drives, complings, conveyors, monitoring systems etc. are described in this article. 2 photos.

01 COAL, LIGNITE, AND PEAT↗

File I/O for MPI Applications in Redundant Execution Scenarios

As multi-petascale and exa-scale high-performance computing (HPC) systems inevitably have to deal with a number of resilience challenges, such as a significant growth in component count and smaller circuit sizes with lower circuit voltages, redundancy may offer an acceptable level of resilience that traditional fault tolerance techniques, such as checkpoint/restart, do not. Although redundancy in HPC is quite controversial due to the associated cost for redundant components, the constantly increasing number of cores-per-processor is tilting this cost calculation toward a system design where computation, such as for redundancy, is much cheaper and communication, needed for checkpoint/restart, is much more expensive. Recent research and development activities in redundancy for Message Passing Interface (MPI) applications focused on availability/reliability models and replication algorithms. This paper takes a first step toward solving an open research problem associated with running a parallel application redundantly, which is file I/O under redundancy. The approach intercepts file I/O calls made by a redundant application to employ coordination protocols that execute file I/O operations in a redundancy-oblivious fashion when accessing a node-local file system, or in a redundancy-aware fashion when accessing a shared networked file system. A proof-of concept prototype is presented and a number of coordination protocols are described and evaluated. The results show the performance impact for redundantly accessing a shared networked file system, but also demonstrate the capability to regain performance by utilizing MPI communication between replicas and parallel file I/O.

99 GENERAL AND MISCELLANEOUS↗

Co-optimization of fuel properties, combustion system geometry, and injection strategy for conventional diesel fuel

Here, studies have shown that fuel properties can impact an engine’s operation in several ways, including ignition delay, sooting tendency, mixture formation, and combustion temperature. In mixing-controlled compression ignition (MCCI) engines, the fuel system design and piston bowl geometry significantly affect combustion performance and emissions. Based on current information, it is difficult to draw conclusions about fuel property effects and sensitivities. The central fuel hypothesis approach used in the US Department of Energy Co-Optima program has worked well for spark ignition fuels: identifying critical fuel property ranges is sufficient to screen fuel blends that are expected to maximize efficiency and reduce pollutant emissions. However, for MCCI-relevant fuels, the information gained from past studies is not sufficient to build such a merit function or to allow for performing a similar screening of fuel blends. It is hypothesized that a co-optimization of a fuel’s physical and chemical properties, combustion system geometry, and injection strategy could leverage synergies between the effects of the fuel properties and geometries, resulting in improved performance over state-of-the-art. A machine learning–assisted unconstrained global optimization algorithm was used to explore a design space comprising 23 independent variables. The results show that physical property effects were minimal even for large variations in fuel properties, and the only interaction effect that was observed was the effect of varied fuel density parameters on fuel/air mixture formation. Nevertheless, these interactions were not sufficient in magnitude to significantly affect optimization results. Therefore, analysis of the results suggests that fuel physical properties cannot be leveraged in a co-optimization context to increase engine efficiency.

33 ADVANCED PROPULSION SYSTEMS↗

Pilot Scale Operation and Testing of Syngas Chemical Looping For Hydrogen Production

The Syngas Chemical looping (SCL) process provides efficient and economic means to utilize the abundant fossil reserve of coal. The main problem associated with coal utilization is the CO 2 emissions resulting from its combustion. Even though CO 2 regulation or carbon tax is currently not in place, its enforcement is expected in the near future. Such a greenhouse gas emission control, if adopted in current power plant systems, will drive the efficiency down and increase the cost of electricity, due to the energy and capital-intensive nature of current CO 2 separation techniques. This highlights the need to develop technologies that present a solution to the rising cost of electricity in the future. The integrated gasification combined cycle (IGCC) presents an improvement to the above predicament, but it is capital intensive due to the extensive unit operations involved. The efficiency for a CO 2 capture incorporated IGCC system is around ~32%, resulting in approximately 45% increase in cost of electricity. This is definitely a better path to traverse than the conventional pulverized coal (PC) power plants as it has improved economics and efficiencies accompanied by product flexibility. The SCL process advances the benefits even further when integrated with the IGCC process. The SCL process removes the expensive WGS system and CO 2 separation columns, thereby saving on capital and operational expenses. This integration results in a 12 – 21% increase in efficiency accompanied by a reduction in cost of electricity by 15 – 28%, over conventional IGCC systems. Therefore, SCL process provides the best route to harness the energy from coal. The overall project objective was to construct and operate a syngas chemical looping pilot scale test unit at the NCCC. The project scope of work was divided into 3 phases. In Phase I, cold flow model studies using a 1:1 scale acrylic test unit constructed at Particulate Solids Research, Inc. (PSRI) was successfully completed confirming robust solid flow control is achievable in the non-mechanical system design. In Phase II, the high pressure, high temperature, chemical looping reactor was successfully designed with all necessary equipment and safety instrumentation/controls specified to allow for fabrication, site construction, and assembly to commence in Phase III. In Phase III, the SCL pilot plant was successfully assembled and all necessary functional checks and pre-startup safety reviews completed. During unit commission over the course of 200 hours of testing, operational issues were observed with premix burner used for system startup. With the grants awarded by the National Energy Laboratory (NETL) and the Ohio Development Services Agency (ODSA) under awards DE-FE0023915 and D-14-18, the SCL pilot unit underwent three auxiliary equipment modifications to resolve all of the startup operational issues encountered. The unit was successfully demonstrated with 300+hr continuous operation. Key results obtained include high syngas conversion of 97.95% with 16.03% oxygen carrier conversion in the moving bed reducer and >99% purity H 2 produced from the moving bed oxidizer.

01 COAL, LIGNITE, AND PEAT↗

National labs examine effects of new fuels on current equipment

Here, studies at two national laboratories show that using existing transportation fuel infrastructure and systems designed for use and compatibility with gasoline and E10 at gas stations likely will create compatibility issues when used with new fuel chemistries. For more than 10 years, The National Renewable Energy Laboratory (NREL) in Golden, Colorado, and Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, have been evaluating what happens when new fuels come into contact with the current storage and dispensing systems.

42 ENGINEERING↗

Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants

Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable oxygen standards and practices for minimum safety requirements. A summary of operational hazards, along with oxygen safety and emergency procedures, are provided.

08 HYDROGEN↗

Study and Considerations of Nanometer and Nano-radian Surface Profiler

A Nanometer and Nano-radian Surface Profiler (NSP) is under development at Brookhaven National Laboratory. Nanometer and nano-radian accuracy is required for newest state-of-the-art synchrotron radiation optics and highprecision optical measurement. This test accuracy must be maintained in larger angle test range. In order to reach this accuracy we have to remove all error sources as much as possible or to reduce them to nano-radian level. We present the approaches in optimized optical system designing, scanning optical head mode selection, non-tilted reference method, quality control of optical components, and temperature stabilization. Some considerations and preliminary measurements are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

Distributed Solar Quality and Safety in India: Key Challenges and Potential Solutions

The quality and safety of solar systems and their installation has become a concern for investors, regulators, consumers, and Discoms in India. The push for low prices and lack of quality standards are driving project developers to install low quality products, with poor system design and execution on-site. Existing literature and stakeholder interviews point to the rampant use of low quality, sub-standard solar products in India. These products deliver less energy than expected, or have high detrition rates, or have lower product life–all of which are serious issues for developers whose return on investment depend on the amount of power generation from these solar systems for the expected life of the project. Equipment which does not conform to the minimum quality standards also creates safety risks for the distribution network. Performance and safety concerns lower investor and consumer confidence in solar products with the potential to threaten market development. This report formulates a set of recommendations to concerned authorities in India to improve the quality and safety of rooftop solar systems. Primary and secondary sources are employed to understand the current solar quality and safety scenario in India to provide the basis for future recommendations. An overview of international experiences and lessons learned on solar quality and safety issues is also conducted to understand potential solutions for India.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design screening and analysis of gas-fired ammonia-based chemisorption heat pumps for space heating in cold climate

Thermally-driven ammonia-based chemisorption heat pumps (CSHP) have the potential to provide high-efficiency space heating in cold climates. Using the reversible chemical bond between sorbent salt and ammonia, CSHP thermochemically pumps heat from the cold ambient to the end-uses of space heating at 50 °C. The heating coefficient of performance (COP) of a CSHP largely depends on the selection of the sorbent salts, cycle configuration, and the system operation. This study uses a thermodynamic model to investigate the performance of six CSHP system configurations, including four single-effect and two double-effect cycles. The feasibility and performance of 121 available NH 3 /salt reactions are studied for each configuration. The thermal COP of the cycles and the primary energy COP of the gas-fired CSHP systems are evaluated assuming 50 °C supply temperature for building space heating and the optimal system designs are identified. The highest thermal COP for single-effect and double-effect cycles under -25 °C ambient temperatures are predicted to be 1.22 and 1.57, respectively. The corresponding primary energy COPs are above 1.0 and 1.15, which are 30% higher than condensing furnaces and is sustained into the same cold temperatures.

42 ENGINEERING↗

Low Activity Waste Pretreatment System (LAWPS) Conceptual Design Approach - 16568

The Low Activity Waste Pretreatment System (LAWPS) will be capable of providing the Waste Treatment and Immobilization Project's (WTP) Low Activity Waste Facility (LAW) the feed material needed to operate both of the LAW melters at full capacity. LAWPS will receive supernatant from the Hanford AP tank farm, filter solids from the waste, remove cesium from the waste, and then stage the feed in storage tanks for supplying the LAW facility. The LAWPS project team is currently executing the preliminary design phase of the project leading to Critical Decision 2 (CD-2). CD-2 is the approval of the performance baseline. The Critical Decision 1 (CD-1) package was approved by the Department of Energy Deputy Under Secretary in May 2015. This paper will focus on creating and gaining approval of the CD-1 package and initiating execution of the preliminary design work. The intent of the paper will be to highlight the activities that facilitated achievement of the goals and present key activities that have been performed to increase the likelihood of preliminary design success. Initiating the immobilization of Hanford tank waste will be a tremendous accomplishment. LAWPS is one of the key projects required to achieve this accomplishment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗