Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results On The Imaging Capabilities Of A DROID Array In The UV/Visible

Within the SCAM project of the European Space Agency the next step in the development of a cryogenic optical photon counting imaging spectrometer would be to increase the field of view using DROIDs (Distributed Read-Out Imaging Detector). We present the results of the first system test using an array of 60 360x33.5 {mu}m{sup 2} DROIDs in a 3x20 format for optical photon detection. This is an increase in area by a factor of 5.5 compared to the successful S-Cam 3 detector. The responsivity of the DROID array tested is too low for actual use on the telescope. However the spatial resolution of {approx}35 {mu}m is just above the size of a virtual pixel and imaging capabilities of the array can be demonstrated. With increasing responsivity this will improve, yielding a DROID array which can be used as an astronomical optical photon counting imaging spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Layered semiconductor neutron detectors

Room temperature operating solid state hand held neutron detectors integrate one or more relatively thin layers of a high neutron interaction cross-section element or materials with semiconductor detectors. The high neutron interaction cross-section element (e.g., Gd, B or Li) or materials comprising at least one high neutron interaction cross-section element can be in the form of unstructured layers or micro- or nano-structured arrays. Such architecture provides high efficiency neutron detector devices by capturing substantially more carriers produced from high energy .alpha.-particles or .gamma.-photons generated by neutron interaction.

47 OTHER INSTRUMENTATION↗

Assay Methods for 238U, 232Th, and 210Pb in Lead and Calibration of 210Bi Bremsstrahlung Emission from Lead

Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are assayed via inductively coupled plasma mass spectrometry (ICP-MS) after anion exchange column separation on dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical precipitation separation on dissolved lead samples. Subsequent to the 210Po α-spectroscopy assay, a method for evaluating 210Pb concentrations in solid lead samples was developed via measurement of bremsstrahlung radiation from β-decay of a daughter isotope, 210Bi, by employing a 14-crystal array of high purity germanium (HPGe) detectors. Ten sources of refined lead were assayed. The 238U concentrations were <34 microBq/kg and the 232Th concentrations ranged <0.6 – 15 microBq/kg, as determined by the ICP-MS assay method. The 210Pb concentrations ranged from ~0.1 – 75 Bq/kg, as inferred by the 210Po α-spectroscopy assay method.

Orrell, John L.↗

Performance Evaluation of PETbox: A Low Cost Bench Top Preclinical PET Scanner

Purpose: PETbox is a low cost bench top preclinical PET scanner dedicated to pharmacokinetic and pharmacodynamic mouse studies. A prototype system was developed at our institute, and this manuscript characterizes the performance of the prototype system. Procedures: The PETbox detector consists of a 20×44 bismuth germanate crystal array with a thickness of 5 mm and cross-section size of 2.05×2.05 mm. Two such detectors are placed facing each other at a spacing of 5 cm, forming a dual-head geometry optimized for imaging mice. The detectors are kept stationary during the scan, making PETbox a limited angle tomography system. 3D images are reconstructed using a maximum likelihood and expectation maximization (ML–EM) method. The performance of the prototype system was characterized based on a modified set of the NEMA NU 4-2008 standards. Results: In-plane image spatial resolution was measured to be an average of 1.53 mm full width at half maximum for coronal images and 2.65 mm for the anterior–posterior direction. The volumetric reconstructed resolution was below 8 mm 3 at most locations in the field of view (FOV). The sensitivity, scatter fraction, and noise equivalent count rate (NECR) were measured for different energy windows. With an energy window of 150 - 650 keV and a timing window of 20 ns optimized for mouse imaging, the peak absolute sensitivity was 3.99% at the center of FOV and a peak NECR of 20 kcps was achieved for a total activity of 3.2 MBq (86.8 μCi). Phantom and in vivo imaging studies were performed and demonstrated the utility of the system at low activity levels. The quantitation capabilities of the system were also characterized showing that despite the limited angle tomography, reasonably good quantification accuracy was achieved over a large dynamic range of activity levels. Conclusions: The presented results demonstrate the potential of this new tomograph for small animal imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Patient-Specific 3D Pretreatment and Potential 3D Online Dose Verification of Monte Carlo-Calculated IMRT Prostate Treatment Plans

Purpose: Fast and reliable comprehensive quality assurance tools are required to validate the safety and accuracy of complex intensity-modulated radiotherapy (IMRT) plans for prostate treatment. In this study, we evaluated the performance of the COMPASS system for both off-line and potential online procedures for the verification of IMRT treatment plans. Methods and Materials: COMPASS has a dedicated beam model and dose engine, it can reconstruct three-dimensional dose distributions on the patient anatomy based on measured fluences using either the MatriXX two-dimensional (2D) array (offline) or a 2D transmission detector (T2D) (online). For benchmarking the COMPASS dose calculation, various dose-volume indices were compared against Monte Carlo-calculated dose distributions for five prostate patient treatment plans. Gamma index evaluation and absolute point dose measurements were also performed in an inhomogeneous pelvis phantom using extended dose range films and ion chamber for five additional treatment plans. Results: MatriXX-based dose reconstruction showed excellent agreement with the ion chamber (<0.5%, except for one treatment plan, which showed 1.5%), film ({approx}100% pixels passing gamma criteria 3%/3 mm) and mean dose-volume indices (<2%). The T2D based dose reconstruction showed good agreement as well with ion chamber (<2%), film ({approx}99% pixels passing gamma criteria 3%/3 mm), and mean dose-volume indices (<5.5%). Conclusion: The COMPASS system qualifies for routine prostate IMRT pretreatment verification with the MatriXX detector and has the potential for on-line verification of treatment delivery using T2D.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Telescope Array Radar (TARA) Observatory for Ultra-High Energy Cosmic Rays

Construction was completed during summer 2013 on the Telescope Array RAdar (TARA) bi-static radar observatory for Ultra-High Energy Cosmic Rays (UHECR). TARA is co-located with the Telescope Array, the largest “conventional” cosmic ray detector in the Northern Hemisphere, in radio-quiet Western Utah. TARA employs an 8 MW Effective Radiated Power (ERP) VHF transmitter and smart receiver system based on a 250 MS/s data acquisition system in an effort to detect the scatter of sounding radiation by UHECR-induced atmospheric ionization. TARA seeks to demonstrate bi-static radar as a useful new remote sensing technique for UHECRs. In this report, we describe the design and performance of the TARA transmitter and receiver systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Majorana Demonstrator Status and Preliminary Results

The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76 Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76 Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Q ββ . The MAJORANA collaboration began taking physics data in 2016. Here, this paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear structure analysis using the Orange Spectrometer

Recently, an Orange spectrometer, a focusing iron-free magnetic spectrometer, has been installed at a beam line of the 10 MV Tandem accelerator of the IKP of the University of Cologne. The high efficiency of 15% of 4{pi} for the detection of conversion electrons and the energy resolution of 1% makes the Orange spectrometer a powerful instrument. From the conversion electron spectrum, transition multipolarities can be determined using the so called K to L ratio. In combination with an array of germanium and lanthanum bromide detectors, e{sup -}-{gamma}-coincidences can be performed to investigate the level scheme. Moreover, the very fast lanthanum bromide scintillator with an energy resolution of 3% allows e{sup -}-{gamma} lifetime measurements down to 0.3 ns. A second Orange spectrometer can be added to build the Double Orange Spectrometer for e{sup -}-e{sup -}-coincidences. It is indispensable for lifetime measurements of low intensity or nearby lying transitions as often occur in odd-A and odd-odd nuclei. The capabilities are illustrated with several examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tri-axial Shape Coexistence and a New Aligned Band in {sup 178}Os

The Os nuclei lie in the beginning of the transitional region between the well deformed rare earth and spherical lead isotopes. The nuclei in this region are believed to be soft to changes in gamma deformation due to the softness of nuclear potential which may result in the shape coexistence. The neutron Fermi levels in Os nuclei from A = 170 to A = 186 lie in the middle of i{sub 13/2} orbital so that their shape in the ground state tends to take an appreciable prolate deformation. Hence collective bands with the well defined moment of inertia occur and the effect of different proton orbitals is observed as a modulation of the prolate structure. The anomalies in the yrast sequence, an effect attributed to change in moment of inertia of the ground state rotational band and the band crossing phenomena, are very important and vary strongly with neutron number in case of Os nuclei. The nuclear structure of {sup 178}Os nucleus has been studied using the reaction {sup 165}Ho({sup 20}Ne, p6n){sup 178}Os. Indian National Gamma Array (INGA) consisting of six Clover detectors with anti Compton shields was used for the detection of resulting gamma rays. The Direction Correlation of {gamma}-rays de-exciting Oriented states (DCO) ratio and polarization of gamma rays were measured to assign spin, parity and multipolarity of transitions. Twenty one new transitions belonging to the {sup 178}Os nucleus have been identified. The sudden and rather strong gain in aligned angular momentum is observed in the yrast band of {sup 178}Os. A new aligned rotational band similar to {sup 180}Os is also discovered in this nucleus. This band exhibits a very complex decay pattern with a single linking transition of 1778 keV to the ground state band. The tri-axial shape co-existence is also observed in this nucleus at higher excitation. The experimental results are compared with the Microscopic Hartree-Fock model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission neutron spectra measurements at LANSCE - status and plans

A program to measure fission neutron spectra from neutron-induced fission of actinides is underway at the Los Alamos Neutron Science Center (LANSCE) in a collaboration among the CEA laboratory at Bruyeres-le-Chatel, Lawrence Livermore National Laboratory and Los Alamos National Laboratory. The spallation source of fast neutrons at LANSCE is used to provide incident neutron energies from less than 1 MeV to 100 MeV or higher. The fission events take place in a gas-ionization fission chamber, and the time of flight from the neutron source to that chamber gives the energy of the incident neutron. Outgoing neutrons are detected by an array of organic liquid scintillator neutron detectors, and their energies are deduced from the time of flight from the fission chamber to the neutron detector. Measurements have been made of the fission neutrons from fission of {sup 235}U, {sup 238}U, {sup 237}Np and {sup 239}Pu. The range of outgoing energies measured so far is from 1 MeV to approximately 8 MeV. These partial spectra and average fission neutron energies are compared with evaluated data and with models of fission neutron emission. Results to date will be presented and a discussion of uncertainties will be given in this presentation. Future plans are to make significant improvements in the fission chambers, neutron detectors, signal processing, data acquisition and the experimental environment to provide high fidelity data including mea urements of fission neutrons below 1 MeV and improvements in the data above 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elastic Scattering of {sup 7}Li+{sup 27}Al at Backward Angles in the 7-11 MeV Energy Range for Application in RBS

We have measured elastic excitation functions for the {sup 7}Li+{sup 27}Al system, in an energy range close to its Coulomb barrier (E{sub lab} = 8.4 MeV) in steps of 0.25 MeV. For this purpose, an array of eight surface-barrier detectors was used. To get an insight on the background composition (mainly {alpha} particles), a telescope-detector was used for atomic-number identification. Identical measurements for the {sup 6}Li+{sup 27}Al system are planned for the near future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lifetime measurement of the 6.79 MeV state in {sup 15}O with the AGATA demonstrator

The {sup 14}N(p,{gamma}){sup 15}O reaction is the slowest process of the CN cycle, and thus it is of high astrophysical interest since it regulates the total rate of energy and neutrinos production through the cycle. The {sup 14}N+p ground state capture is strongly influenced by a sub-threshold resonance corresponding to the 6.79 MeV state in {sup 15}O. The width of this resonance is a major source of uncertainty in the extrapolation of the reaction cross section in the Gamow energy window. Preliminary results of a new Doppler Shift Attenuation measurement of the lifetime of the 6.79 MeV state in {sup 15}O are discussed. The level of interest was populated via the {sup 2}H({sup 14}N,n){sup 15}O reaction in inverse kinematics at 32 MeV beam energy. The gamma-rays emitted in the decay of the 6.79 MeV level to the ground state were detected with the AGATA Demonstrator array of high-purity germanium detectors. The sensitivity of the shape of the peak in the gamma-ray energy spectrum to the level lifetime is investigated comparing the experimental peaks with detailed Monte Carlo simulations of the reaction mechanisms and the gamma-ray emission and detection. Nuclear levels in {sup 15}N (also populated in the {sup 14}N+{sup 2}H reaction) for which the lifetimes are known in the literature provided a test of the analysis technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of near- and far-field impurity flows during pellet-induced rapid shutdown in DIII-D

Both near-field (<1 m away toroidally from the pellet) and far-field (>1 m away toroidally from the pellet) poloidal and toroidal impurity (carbon ion) flows are measured using visible imaging and fast bolometry during a polypropylene pellet-induced rapid plasma shutdown in the DIII-D tokamak. In the near field, the pellet appears to increase poloidal flow in the ion diamagnetic direction, possibly due to the strong radial temperature gradient caused by the pellet ablation. In the far field, the poloidal impurity flow typically appears slower and in the opposite direction. Toroidal impurity flow appears to be strongly influenced by the plasma initial toroidal rotation, especially in the far field. These results demonstrate that rapid shutdown impurity flows are not necessarily global in structure but can be quite different close to and far from the injected pellet.

Electromagnetic radiation detectors↗

SOFT X-RAY SPECTROSCOPY OF THE CYGNUS LOOP SUPERNOVA REMNANT

We present the results of a suborbital rocket flight whose scientific target was the Cygnus Loop Supernova Remnant. The payload consists of wire grid collimators, off-plane grating arrays, and gaseous electron multiplier (GEM) detectors. The system is designed for spectral measurements in the 17-107 A bandpass with a resolution up to {approx}60 ({lambda}/{Delta}{lambda}). The Extended X-ray Off-plane Spectrometer (EXOS) was launched on a Terrier-Black Brant rocket on 2009 November 13 from White Sands Missile Range and obtained 340 s of useable scientific data. The X-ray emission is dominated by O VII and O VIII, including the He-like O VII triplet at {approx}22 A. Another emission feature at {approx}45 A is composed primarily of Si XI and Si XII. The best-fit model to this spectrum is an equilibrium plasma model at a temperature of log(T) = 6.4 (0.23 keV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TeV gamma-ray survey of the northern sky using the ARGO-YBJ detector

The Astrophysical Radiation with Ground-based Observatory at Yang Ba Jing (ARGO-YBJ) detector is an extensive air shower array that has been used to monitor the northern γ-ray sky at energies above 0.3 TeV from 2007 November to 2013 January. In this paper, we present the results of a sky survey in the declination band from –10° to 70°, using data recorded over the past five years. With an integrated sensitivity ranging from 0.24 to ∼1 Crab units depending on the declination, six sources have been detected with a statistical significance greater than five standard deviations. Several excesses are also reported as potential γ-ray emitters. The features of each source are presented and discussed. Additionally, 95% confidence level upper limits of the flux from the investigated sky region are shown. Specific upper limits for 663 GeV γ-ray active galactic nuclei inside the ARGO-YBJ field of view are reported. The effect of the absorption of γ-rays due to the interaction with extragalactic background light is estimated.

79 ASTRONOMY AND ASTROPHYSICS↗

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the theoretical background and experimental method and report on preliminary analysis of the LANSCE data. The second phase of the program to measure A{sub {Gamma}Y} is in progress at the Spallation Neutron Source at Oak Ridge National Laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗