Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

JSPEC: A Program for IBS and Electron Cooling Simulation

Intrabeam scattering is an important collective effect that can deteriorate the properties of a high-intensity beam, and electron cooling is a method to mitigate the IBS effect. JSPEC (JLab Simulation Package for Electron Cooling) is an open-source program developed at Jefferson Lab, which simulates the evolution of the ion beam under the IBS and/or the electron cooling effect. JSPEC has been benchmarked with BETACOOL and experimental data. In this report, we will introduce the features of JSPEC, including the friction force calculation, the IBS expansion rate and electron cooling rate calculation, and the beam-dynamic simulations for the electron cooling process; explain how to set up the simulations in JSPEC; and demonstrate the benchmarking results.

Zhang, He↗

Tunable intense Airy beams and tailored femtosecond laser filaments

Optical aberrations are usually considered a drawback in optical systems. Here we show that through them a net cubic phase modulation can be imprinted on the wave front of a light beam, which after spatial Fourier transformation creates Airy beams. Experiments and supporting simulations demonstrate that appropriately adjusted cylindrical lenses can produce both one- and two-dimensional tunable Airy beams. The use of simple optical elements makes the approach attractive and convenient for generating intense femtosecond Airy beams and filaments. Moreover, we show that the Airy tunability is an excellent means of obtaining tailored filaments in both size and intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linearization of an Electron Beam’s Longitudinal Phase Space Using a Hollow-Channel Plasma

The removal of undesired beam nonlinear energy chirp (time-energy correlation) or linearization of the beam longitudinal phase space (LPS) is crucial for high-brightness linac-based scientific applications, such as x-ray free-electron lasers. In this paper, we propose that a low-density hollow channel plasma can be used as a near-ideal passive linearizer to significantly linearize the beam LPS and, at the same time, preserve the beam emittance. Physically, the passage of the beam through the hollow plasma channel excites a strong quasicosinoidal longitudinal wakefield that acts to mitigate the beam nonlinear energy chirp by superimposing a reverse chirp on the beam. The theoretical analyses and large-scale three-dimensional start-to-end simulations confirm that the beam longitudinal phase space can be almost completely linearized without noticeable beam emittance growth. In conclusion, application of such a near-ideal linearizer may significantly improve the performance of numerous accelerator-based applications.

43 PARTICLE ACCELERATORS↗

Towards robust laser beam propagation in atmospheric turbulence

High-fidelity optical propagation through the atmosphere is essential for free-space optical technologies, including laser-based remote sensing and optical communication. However, atmospheric turbulence severely distorts beams and compromises system performance. In this work, we employ hypergeometric-Gaussian (HyGG) vortex beams as probes to characterize and mitigate atmospheric turbulence. Using over 250,000 experimental and simulated frames, we show that refining the power spectrum density (PSD) can reduce numerical prediction errors by up to 79.8%. Concurrently, experimental observations supported by numerical simulations demonstrate that HyGG beams exhibit superior turbulence resilience across multiple metrics compared to conventional Gaussian beams, particularly in their ability to withstand over 5 times stronger turbulence while maintaining similar intensity fluctuations. These dual investigations, on both turbulence mitigation and robust beam solutions, converge to form a unified strategy for enhancing free-space optical system performance. Collectively, our findings provide new insights into light–turbulence interactions and highlight the practical utility of vortex beams under atmospheric conditions.

Zhang, Boyu↗

Whistler Wave Excitation and Effects of Self-Focusing on Ion Beam Propagation through a Background Plasma along a Solenoidal Magnetic Field

This paper extends studies of ion beam transport through a background plasma along a solenoidal magnetic field [I. Kaganovich et al., Phys. Plasmas 15, 103108 (2008)] to the important regime of moderate magnetic field strength satisfying ωce > 2βbωpe . Here, ωce and ω pe are the electron cyclotron frequency and electron plasma frequency, respectively, and βb = vb/ c is the directed ion beam velocity normalized to the speed of light. The electromagnetic field perturbations excited by the ion beam pulse in this regime are calculated analytically, and verified by comparison with the numerical simulations. The degrees of beam charge neutralization and current neutralization are estimated, and the transverse component of the Lorentz force associated with the excited electromagnetic field is calculated. It is found that the plasma response to the ion beam pulse is significantly different depending on whether the value of the solenoidal magnetic field is below or above the threshold value specified by ω cr ce = 2βbωpe, and corresponding to the resonant excitation of large-amplitude whistler waves. The use of intense whistler wave excitations for diagnostic purposes is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MEIC Design Progress

This paper will report the recent progress in the conceptual design of MEIC, a high luminosity medium energy polarized ring-ring electron-ion collider at Jefferson lab. The topics and achievements that will be covered are design of the ion large booster and the ERL-circulator-ring-based electron cooling facility, optimization of chromatic corrections and dynamic aperture studies, schemes and tracking simulations of lepton and ion polarization in the figure-8 collider ring, and the beam-beam and electron cooling simulations. A proposal of a test facility for the MEIC electron cooler will also be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of a localized chaos by rf-phase modulations in phase-space dilution

Physics of chaos in a localized phase-space region is exploited to produce a longitudinally uniformly distributed beam. Theoretical study and simulations are used to study its origin and applicability in phase-space dilution of beam bunch. Through phase modulation to a double-rf system, a central region of localized chaos bounded by invariant tori are generated by overlapping parametric resonances. Condition and stability of the chaos will be analyzed. Applications include high-power beam, beam distribution uniformization, and industrial beam irradiation.

43 PARTICLE ACCELERATORS↗

Kilovoltage Rotational External Beam Radiotherapy on a Breast Computed Tomography Platform: A Feasibility Study

Purpose: To demonstrate the feasibility of a dedicated breast computed tomography (bCT) platform to deliver rotational kilovoltage (kV) external beam radiotherapy (RT) for partial breast irradiation, whole breast irradiation, and dose painting. Methods and Materials: Rotational kV-external beam RT using the geometry of a prototype bCT platform was evaluated using a Monte Carlo simulator. A point source emitting 178 keV photons (approximating a 320-kVp spectrum with 4-mm copper filtration) was rotated around a 14-cm voxelized polyethylene disk (0.1 cm tall) or cylinder (9 cm tall) to simulate primary and primary plus scattered photon interactions, respectively. Simulations were also performed using voxelized bCT patient images. Beam collimation was varied in the x-y plane (1-14 cm) and in the z-direction (0.1-10 cm). Dose painting for multiple foci, line, and ring distributions was demonstrated using multiple rotations with varying beam collimation. Simulations using the scanner's native hardware (120 kVp filtered by 0.2-mm copper) were validated experimentally. Results: As the x-y collimator was narrowed, the two-dimensional dose profiles shifted from a cupped profile with a high edge dose to an increasingly peaked central dose distribution with a sharp dose falloff. Using a 1-cm beam, the cylinder edge dose was <7% of the dose deposition at the cylinder center. Simulations using 120-kVp X-rays showed distributions similar to the experimental measurements. A homogeneous dose distribution (<2.5% dose fluctuation) with a 20% decrease in dose deposition at the cylinder edge (i.e., skin sparing) was demonstrated by weighted summation of four dose profiles using different collimation widths. Simulations using patient bCT images demonstrated the potential for treatment planning and image-guided RT. Conclusions: Rotational kV-external beam RT for partial breast irradiation, dose painting, and whole breast irradiation with skin sparing is feasible on a bCT platform with the potential for high-resolution image-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rotation of a 1-GeV particle beam by a fan system of thin crystals

The deflection of a 1-GeV charged particle beam by a system formed by fan-oriented thin silicon wafers has been studied theoretically and experimentally. Software has been developed for numerical simulation of a particle beam transmission through a fan crystal system. In the U-70 experiment on a proton beam, the particles were deflected by such a system through an angle exceeding 1 mrad. Thus, a new method has been demonstrated for rotating a particle beam, which can be used for creating accelerator beams for medical purposes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid Automated Diagnosis of Discrete/Continuous Systems

A recently conceived method of automated diagnosis of a complex electromechanical system affords a complete set of capabilities for hybrid diagnosis in the case in which the state of the electromechanical system is characterized by both continuous and discrete values (as represented by analog and digital signals, respectively). The method is an integration of two complementary diagnostic systems: (1) beacon-based exception analysis for multi-missions (BEAM), which is primarily useful in the continuous domain and easily performs diagnoses in the presence of transients; and (2) Livingstone, which is primarily useful in the discrete domain and is typically restricted to quasi-steady conditions. BEAM has been described in several prior NASA Tech Briefs articles: "Software for Autonomous Diagnosis of Complex Systems" (NPO-20803), Vol. 26, No. 3 (March 2002), page 33; "Beacon-Based Exception Analysis for Multimissions" (NPO-20827), Vol. 26, No. 9 (September 2002), page 32; "Wavelet-Based Real-Time Diagnosis of Complex Systems" (NPO-20830), Vol. 27, No. 1 (January 2003), page 67; and "Integrated Formulation of Beacon-Based Exception Analysis for Multimissions" (NPO-21126), Vol. 27, No. 3 (March 2003), page 74. Briefly, BEAM is a complete data-analysis method, implemented in software, for real-time or off-line detection and characterization of faults. The basic premise of BEAM is to characterize a system from all available observations and train the characterization with respect to normal phases of operation. The observations are primarily continuous in nature. BEAM isolates anomalies by analyzing the deviations from nominal for each phase of operation. Livingstone is a model-based reasoner that uses a model of a system, controller commands, and sensor observations to track the system s state, and detect and diagnose faults. Livingstone models a system within the discrete domain. Therefore, continuous sensor readings, as well as time, must be discretized. To reason about continuous systems, Livingstone uses monitors that discretize the sensor readings using trending and thresholding techniques. In development of the a hybrid method, BEAM results were sent to Livingstone to serve as an independent source of evidence that is in addition to the evidence gathered by Livingstone standard monitors. The figure depicts the flow of data in an early version of a hybrid system dedicated to diagnosing a simulated electromechanical system. In effect, BEAM served as a "smart" monitor for Livingstone. BEAM read the simulation data, processed the data to form observations, and stored the observations in a file. A monitor stub synchronized the events recorded by BEAM with the output of the Livingstone standard monitors according to time tags. This information was fed to a real-time interface, which buffered and fed the information to Livingstone, and requested diagnoses at the appropriate times. In a test, the hybrid system was found to correctly identify a failed component in an electromechanical system for which neither BEAM nor Livingstone alone yielded the correct diagnosis.

Park, Han↗

Extraction Simulations and Emittance Measurements of a Holifield Radioactive Ion Beam Facility Electron Beam Plasma Source for Radioactive Ion Beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

Liu, Yuan↗

Implementation of an iterative matching scheme for the Kapchinskij-Vladimirskij equations in the WARP code

The WARP code is a robust electrostatic particle-in-cell simulation package used to model charged particle beams with strong space-charge forces. A fundamental operation associated with seeding detailed simulations of a beam transport channel is to generate initial conditions where the beam distribution is matched to the structure of a periodic focusing lattice. This is done by solving for periodic, matched solutions to a coupled set of ODEs called the Kapchinskij-Vladimirskij (KV) envelope equations, which describe the evolution of low-order beam moments subject to applied lattice focusing, space-charge defocusing, and thermal defocusing forces. Recently, an iterative numerical method was developed (Lund, Chilton, and Lee, Efficient computation of matched solutions to the KV envelope equations for periodic focusing lattices, Physical Review Special Topics-Accelerators and Beams 9, 064201 2006) to generate matching conditions in a highly flexible, convergent, and fail-safe manner. This method is extended and implemented in the WARP code as a Python package to vastly ease the setup of detailed simulations. In particular, the Python package accommodates any linear applied lattice focusing functions without skew coupling, and a more general set of beam parameter specifications than its predecessor. Lattice strength iteration tools were added to facilitate the implementation of problems with specific applied focusing strengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of an interactive matching scheme for the Kapchinskij-Vladimirskij equations in the WARP code

The WARP code is a robust electrostatic particle-in-cell simulation package used to model charged particle beams with strong space-charge forces. A fundamental operation associated with seeding detailed simulations of a beam transport channel is to generate initial conditions where the beam distribution is matched to the structure of a periodic focusing lattice. This is done by solving for periodic, matched solutions to a coupled set of ODEs called the Kapchinskij-Vladimirskij (KV) envelope equations, which describe the evolution of low-order beam moments subject to applied lattice focusing, space-charge defocusing, and thermal defocusing forces. Recently, an iterative numerical method was developed (Lund, Chilton, and Lee, Efficient computation of matched solutions to the KV envelope equations for periodic focusing lattices, Physical Review Special Topics-Accelerators and Beams 9, 064201 2006) to generate matching conditions in a highly flexible, convergent, and fail-safe manner. This method is extended and implemented in the WARP code as a Python package to vastly ease the setup of detailed simulations. In particular, the Python package accommodates any linear applied lattice focusing functions without skew coupling, and a more general set of beam parameter specifications than its predecessor. Lattice strength iteration tools were added to facilitate the implementation of problems with specific applied focusing strengths.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-657: In-Room Neutron Dose From High Energy Photon Beams

Purpose: To estimate neutron dose inside the treatment room from photodisintegration events in high energy photon beams using Monte Carlo simulations and experimental measurements. Methods: The Monte Carlo code MCNP6 was used for the simulations. An Eberline ESP-1 Smart Portable Neutron Detector was used to measure neutron dose. A water phantom was centered at isocenter on the treatment couch, and the detector was placed near the phantom. A Varian 2100EX linear accelerator delivered an 18MV open field photon beam to the phantom at 400MU/min, and a camera captured the detector readings. The experimental setup was modeled in the Monte Carlo simulation. The source was modeled for two extreme cases: a) hemispherical photon source emitting from the target and b) cone source with an angle of the primary collimator cone. The model includes the target, primary collimator, flattening filter, secondary collimators, water phantom, detector and concrete walls. Energy deposition tallies were measured for neutrons in the detector and for photons at the center of the phantom. Results: For an 18MV beam with an open 10cm by 10cm field and the gantry at 180°, the Monte Carlo simulations predict the neutron dose in the detector to be 0.11% of the photon dose in the water phantom for case a) and 0.01% for case b). The measured neutron dose is 0.04% of the photon dose. Considering the range of neutron dose predicted by Monte Carlo simulations, the calculated results are in good agreement with measurements. Conclusion: We calculated in-room neutron dose by using Monte Carlo techniques, and the predicted neutron dose is confirmed by experimental measurements. If we remodel the source as an electron beam hitting the target for a more accurate representation of the bremsstrahlung fluence, it is feasible that the Monte Carlo simulations can be used to help in shielding designs.

60 APPLIED LIFE SCIENCES↗

Parallel Simulation Algorithms for the Three Dimensional Strong-Strong Beam-Beam Interaction

The strong-strong beam-beam effect is one of the most important effects limiting the luminosity of ring colliders. Little is known about it analytically, so most studies utilize numeric simulations. The two-dimensional realm is readily accessible to workstation-class computers (cf.,e.g.,[1, 2]), while three dimensions, which add effects such as phase averaging and the hourglass effect, require vastly higher amounts of CPU time. Thus, parallelization of three-dimensional simulation techniques is imperative; in the following we discuss parallelization strategies and describe the algorithms used in our simulation code, which will reach almost linear scaling of performance vs. number of CPUs for typical setups.

43 PARTICLE ACCELERATORS↗

TH-A-19A-07: The Effect of Particle Tracking Step Size Limit On Monte Carlo- Computed LET Spectrum of Therapeutic Proton Beams

Purpose: To investigate the effect of charged particle tracking step size limit in the determination of the LET spectrum of therapeutic proton beams using Monte Carlo simulations. Methods: The LET spectra at different depths in a water phantom from a 79.7 MeV spot-scanning proton beam were calculated using Geant4. Five different tracking step limits 0.5 mm, 0.1 mm, 0.05 mm, 0.01 mm and 1 μm were adopted. The field size was set to 10×10 cm{sup 2} on the isocenter plane. A 40×40×6 cm{sup 3} water phantom was modelled as the irradiation target. The voxel size was set to 1×1×0.5 mm{sup 3} to obtain high resolution results. The LET spectra were scored ranging from 0.01 keV/μm to 10{sup 4}keV/μm in the logarithm scale. In addition, the proton energy spectra at different depths were also scored. Results: The LET spectra calculated using different step size limits were compared at four depths along the Bragg curve. At any depths, the spread of the LET spectra increases with the decrease of step size limit. In the dose buildup region (z = 1.9 cm) and in the region proximal to the Bragg peak (z = 3.95 cm), the frequency mean LET does not vary with decreasing step size limit. At Bragg peak (z = 4.75 cm) and in the distal edge (z = 4.85 cm), frequency mean LET decreases with decreasing step size limit. The energy spectrum at any specified depths does not vary with the step size limit. Conclusion: The calculated LET has a spectral distribution rather than a single value at any depths along the Bragg curve and the spread of the computed spectrum depends on the tracking step limit. Incorporating the LET spectrum distribution into the robust IMPT optimization plan may provide more accurate biological dose distribution than using the dose- or fluence-averaged LET. NIH Program Project Grant P01CA021239.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams

Purpose: By using Monte Carlo simulations, the authors investigated the energy and angular dependence of the response of plastic scintillation detectors (PSDs) in photon beams. Methods: Three PSDs were modeled in this study: A plastic scintillator (BC-400) and a scintillating fiber (BCF-12), both attached by a plastic-core optical fiber stem, and a plastic scintillator (BC-400) attached by an air-core optical fiber stem with a silica tube coated with silver. The authors then calculated, with low statistical uncertainty, the energy and angular dependences of the PSDs' responses in a water phantom. For energy dependence, the response of the detectors is calculated as the detector dose per unit water dose. The perturbation caused by the optical fiber stem connected to the PSD to guide the optical light to a photodetector was studied in simulations using different optical fiber materials. Results: For the energy dependence of the PSDs in photon beams, the PSDs with plastic-core fiber have excellent energy independence within about 0.5% at photon energies ranging from 300 keV (monoenergetic) to 18 MV (linac beam). The PSD with an air-core optical fiber with a silica tube also has good energy independence within 1% in the same photon energy range. For the angular dependence, the relative response of all the three modeled PSDs is within 2% for all the angles in a 6 MV photon beam. This is also true in a 300 keV monoenergetic photon beam for PSDs with plastic-core fiber. For the PSD with an air-core fiber with a silica tube in the 300 keV beam, the relative response varies within 1% for most of the angles, except in the case when the fiber stem is pointing right to the radiation source in which case the PSD may over-response by more than 10%. Conclusions: At {+-}1% level, no beam energy correction is necessary for the response of all three PSDs modeled in this study in the photon energy ranges from 200 keV (monoenergetic) to 18 MV (linac beam). The PSD would be even closer to water equivalent if there is a silica tube around the sensitive volume. The angular dependence of the response of the three PSDs in a 6 MV photon beam is not of concern at 2% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of breast tissue composition with dual energy cone-beam computed tomography: A postmortem study

Purpose: To investigate the feasibility of a three-material compositional measurement of water, lipid, and protein content of breast tissue with dual kVp cone-beam computed tomography (CT) for diagnostic purposes. Methods: Simulations were performed on a flat panel-based computed tomography system with a dual kVp technique in order to guide the selection of experimental acquisition parameters. The expected errors induced by using the proposed calibration materials were also estimated by simulation. Twenty pairs of postmortem breast samples were imaged with a flat-panel based dual kVp cone-beam CT system, followed by image-based material decomposition using calibration data obtained from a three-material phantom consisting of water, vegetable oil, and polyoxymethylene plastic. The tissue samples were then chemically decomposed into their respective water, lipid, and protein contents after imaging to allow direct comparison with data from dual energy decomposition. Results: Guided by results from simulation, the beam energies for the dual kVp cone-beam CT system were selected to be 50 and 120 kVp with the mean glandular dose divided equally between each exposure. The simulation also suggested that the use of polyoxymethylene as the calibration material for the measurement of pure protein may introduce an error of -11.0%. However, the tissue decomposition experiments, which employed a calibration phantom made out of water, oil, and polyoxymethylene, exhibited strong correlation with data from the chemical analysis. The average root-mean-square percentage error for water, lipid, and protein contents was 3.58% as compared with chemical analysis. Conclusions: The results of this study suggest that the water, lipid, and protein contents can be accurately measured using dual kVp cone-beam CT. The tissue compositional information may improve the sensitivity and specificity for breast cancer diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗