Search NASA⌕ Search

SEARCH · Search NASA

Results for “control systems platform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Computerized procedures system

An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

Lipner, Melvin H↗

Volttron: An Agent Platform for the Smart Grid

VOLLTRON platform enables the deployment of intelligent sensors and controllers in the smart grid and provides a stable, secure and flexible framework that expands the sensing and control capabilities. VOLTTRON platform provides services fulfilling the essential requirements of resource management and security for agent operation in the power grid. The facilities provided by the platform allow agent developers to focus on the implementation of their agent system and not on the necessary "plumbing' code. For example, a simple collaborative demand response application was written in less than 200 lines of Python.

agents↗

CEEP (Cyber-Energy Emulation Platform) [SWR-20-102]

NREL's Cyber-Energy Emulation Platform (CEEP) provides the capability to realize cyber-energy security and resilience through automation and orchestration of virtualized systems and software defined networks for the electric grid. CEEP enables testing and validation of grid-security and -control methodologies as the grid evolves to include smart technologies/systems, such as virtualization and containerization of grid components, software defined networking, simulation and co-simulation frameworks, and hardware in the loop. CEEP is a modular system that can be distributed and deployed across different hardware infrastructure sizes and network architectures. For example, CEEP can visualize, emulate, and/or coordinate the Smart-Grid Network Visualization, Intrusion Detection, and Network Healing system. Using CEEP, intrusion-detection and network-self-healing solutions can be deployed at grid control centers, within secure private clouds, and in cyber-energy appliances.

Vaughan, Evan↗

Cyber Energy Emulation Platform (CEEP) [SWR-20-102]

NREL's Cyber-Energy Emulation Platform (CEEP) provides the capability to realize cyber-energy security and resilience through automation and orchestration of virtualized systems and software defined networks for the electric grid. CEEP enables testing and validation of grid-security and -control methodologies as the grid evolves to include smart technologies/systems, such as virtualization and containerization of grid components, software defined networking, simulation and co-simulation frameworks, and hardware in the loop. CEEP is a modular system that can be distributed and deployed across different hardware infrastructure sizes and network architectures. For example, CEEP can visualize, emulate, and/or coordinate the Smart-Grid Network Visualization, Intrusion Detection, and Network Healing system. Using CEEP, intrusion-detection and network-self-healing solutions can be deployed at grid control centers, within secure private clouds, and in cyber-energy appliances.

Rivera, Joshua↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing Results from the Low Activity Waste Pretreatment System (LAWPS) Full-Scale Ion Exchange Column Test and Engineering Scale Integrated System Test - 18634

The U.S. Department of Energy (DOE), Office of River Protection's (ORP) primary mission is to retrieve and treat Hanford's tank waste and close the Tank Farms to protect the Columbia River. Mixed radioactive waste is stored in 177 underground tanks at the Hanford Site as reported in DOE/ORP 2003- 02, Environmental Impact Statement for Retrieval, Treatment, and Disposal of Tank Waste and Closure of the Single Shell Tanks at the Hanford Site, Richland WA, Inventory and Source Term Data Package. The 177 underground tanks are estimated to contain about 56 million gallons of waste. The Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low activity waste (ILAW) by feeding LAW directly from Tank Farms to the Hanford Waste Treatment Plant's (WTP's) LAW Facility, bypassing the Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria. The LAWPS will also facilitate the return of secondary liquid wastes from the WTP LAW Vitrification Facility to the Tank Farms. In November of 2015 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to the AECOM team to design, fabricate and operate two test platforms to generate performance data at two different scales and demonstrate technology maturation. The first platform models the ion exchange (IX) columns at full scale, and the second platform models the integrated flowsheet (cross flow filter (CFF) and IX) at 1/9. scale. Overarching technical objectives of performing the full-scale ion exchange test and the engineering-scale integrated test are to: 1. Test interactions between unit process operations; 2. Test removal of non-radioactive cesium from process stream; 3. Test removal of undissolved solids from process stream; 4. Confirm operational flow rate range and stability; 5. Confirm volumetric throughput of waste stream over flow operating range; 6. Confirm range of process temperatures over planned operating range; 7. Establish system hydraulics and process criteria; 8. Coordinate key control and monitoring components; 9. Establish treated product chemistry meets requirements (cesium, solids, and pH); and 10. Test the hazard control strategy for a no flow condition through the IX column. Data collected during testing will be used by WRPS to validate the preliminary design, inform the final design of the permanent plant equipment, and demonstrate that the critical technology elements have advanced to a technology readiness level of 6 (prototypical system validation in a relevant environment). Testing on both platforms started in fall of 2016 generating NQA-1 data. This paper covers test results from the first five phases of testing on the 1/9. scale integrated test platform. A further three phases of testing are currently being executed, these including a 5.6 M sodium simulant containing foulant, a high viscosity simulant and finally a run performed with a lower Cs concentration (all earlier tests were spiked to 4 x Cs to reduce volume and cost). Results from these tests were not available at the time of writing available. Results are also presented from the full scale IX testing. Eight test were performed covering column loading, elution and regeneration; column loading, elution and regeneration with upflow displacement; IX column loading and gas migration; resin removal; solids accumulation; and IX column emergency recirculation and vent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling and control of flexible space platforms with articulated payloads

The first steps in developing a methodology for spacecraft control-structure interaction (CSI) optimization are identification and classification of anticipated missions, and the development of tractable mathematical models in each mission class. A mathematical model of a generic large flexible space platform (LFSP) with multiple independently pointed rigid payloads is considered. The objective is not to develop a general purpose numerical simulation, but rather to develop an analytically tractable mathematical model of such composite systems. The equations of motion for a single payload case are derived, and are linearized about zero steady-state. The resulting model is then extended to include multiple rigid payloads, yielding the desired analytical form. The mathematical models developed clearly show the internal inertial/elastic couplings, and are therefore suitable for analytical and numerical studies. A simple decentralized control law is proposed for fine pointing the payloads and LFSP attitude control, and simulation results are presented for an example problem. The decentralized controller is shown to be adequate for the example problem chosen, but does not, in general, guarantee stability. A centralized dissipative controller is then proposed, requiring a symmetric form of the composite system equations. Such a controller guarantees robust closed loop stability despite unmodeled elastic dynamics and parameter uncertainties.

Graves, Philip C.↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

Quantum Fourier Transform with Leakage Control

In circuit QED (cQED) systems, one can manipulate the cavity Fock states to use quantum processing unit (QPU). Since the coherence times of the Fock states are long, qudit based computation can be possible. One of the most basic gate that can be engineered in this cQED platform is the displacement gate, $D(\alpha)$. However, accessible number of qudit-levels is finite. The truncated displacement gate on the qudit is the source of theoretical error above the logical states and needs to be addressed. In this work, we monitor and minimize the leakage in qudit systems that involves displacement gate by introducing so-called `bumper' states and a modified cost function.

Kurkcuoglu, D. [Fermilab] (ORCID:0000000311097074)↗

Ground data system for Space Flyer Unit (SFU)

The Space Flyer Unit (SFU) is an unmanned, multi-purpose, retrievable and reusable space platform. The first mission of SFU (SFU-1) will be launched by NASDA's H-2 launch vehicle in early 1995 and retrieved by NASA's Space Shuttle after several months in orbit. Two Japanese ground stations, several ground stations belonging to NASA, and a ground station in Chile will be used for tracking of SFU-1. The control center of SFU-1 is the Sagamihara Operations Center (SOC) of ISAS located in Sagamihara, Japan. This paper describes the tracking and data acquisition network for SFU-1, the configuration and design policy of the SFU operations control system, and data processing schemes used for mission operations of SFU.

Yamada, Takahiro↗

ADX: a high field, high power density, advanced divertor and RF tokamak

The MIT Plasma Science and Fusion Center and collaborators are proposing a high-performance Advanced Divertor and RF tokamak eXperiment (ADX) – a tokamak specifically designed to address critical gaps in the world fusion research program on the pathway to next step devices: fusion nuclear science facility (FNSF), fusion pilot plant (FPP), and/or demonstration power plant (DEMO). This high field (≥ 6.5 tesla, 1.5 MA), high power density facility (P/S ~ 1.5 MW/m2) will test innovative divertor ideas, including an ‘X-point target divertor’ concept, at the required performance parameters – reactor-level boundary plasma pressures, magnetic field strengths and parallel heat flux densities entering into the divertor region – while simultaneously producing high performance core plasma conditions that are prototypical of a reactor: equilibrated electrons and ions, regimes with low or no torque, and no fueling from external heating and current drive systems. Equally important, the experimental platform will test innovative concepts for lower hybrid current drive (LHCD) and ion-cyclotron range of frequency (ICRF) actuators with the unprecedented ability to deploy launch structures both on the lowmagnetic- field side and the high-magnetic-field side – the latter being a location where energetic plasma-material interactions can be controlled and favorable RF wave physics leads to efficient current drive, current profile control, heating and flow drive. This triple combination – advanced divertors, advanced RF actuators, reactor-prototypical core plasma conditions – will enable ADX to explore enhanced core confinement physics, such as made possible by reversed central shear, using only the types of external drive systems that are considered viable for a fusion power plant. Such an integrated demonstration of high-performance core-divertor operation with steady state sustainment would pave the way toward an attractive pilot plant, as envisioned in the ARC concept (Affordable, Robust, Compact) [B. N. Sorbom, et al., submitted to Fusion Engineering Design, 2014] that makes use of high-temperature superconductor technology – a high-field (9.25 tesla) tokamak the size of the Joint European Torus that produces 270 MW of net electricity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of the handling and positioning aid

The handling and positioning aid which (HPA) provides a wide range of adjustable work stations both inboard and outboard of the cargo bay is discussed. It can assist with berthing and docking, it is robust, stiff, has a simple control system, and is modular. An articulated arm version of HPA employed in a typical servicing mission is shown. Mounted on a base frame that spans the Orbiter cargo bay, the 6 m arm is long enough to hold the satellite being serviced and keep its solar array clear of the Orbiter radiators. By adjusting the length and angle of the support platform mast, and rotating the tip of the HPA arm, almost every item on the satellite can be reached. Spares and change-out units can be brought to and from the work site by the RMS, which is controlled from the aft flight deck. The fore and aft position of the base frame can be changed between Orbiter flights and this, together with the 5 degrees of freedom (DOF) of the long arm, allows work sites to be chosen that meet the clearance, reach and vision requirements of many missions. Flight article activities are shown are shown above the dashed horizontal line and Development Test Article (DTA) work below. Flight article requirements and concepts and the design of the DTA are developed.

Goodwin, C. J.↗

Control of the flexible modes of an advanced technology geostationary platform

A controls analysis is conducted on an advanced technology geostationary platform. This spacecraft is a large flexible structure with a payload of Earth-sensing instruments which will collect data from Earth's oceans, land, and atmosphere as a part of the bold initiative mission to Planet Earth proposed by NASA. This program will provide a collection of data from a family of spacecraft in both low-Earth orbit and geostationary orbit, which will afford a global definition of the Earth as a system with the capability to predict future events resulting from human and natural forces. The platform concept studied here is a large flexible structure with a payload of eighteen instruments. Because the platform is in geostationary orbit, these instruments have sensitive pointing accuracy requirements, in the range of 0.1 to 0.0001 degrees, which must be satisfied. The structure housing the instruments is large and flexible with characteristic low natural frequencies, so active control is necessary for vibration suppression.

Dewalt, Diane V.↗

Retrieval of high time resolution growth factor probability density function from a humidity-controlled fast integrated mobility spectrometer

Hygroscopicity describes the tendency of aerosol particle to uptake water and is among the key parameters in determining the impact of atmospheric aerosols on global radiation and climate. A hygroscopicity tandem differential mobility analyzer (HTDMA) system is the most widely utilized instrument for determining the aerosol hygroscopic growth. Because of the time needed to scan the classifying voltage of the DMA, HTDMA measurement normally requires a minimum of 30 min to characterize the particle hygroscopic growth at a single relative humidity for five to six different sizes. This slow speed is often inadequate for measurements onboard mobile platforms or when aerosols evolve rapidly. Recently, a humidity-controlled fast integrated mobility spectrometer (HFIMS) was developed for measuring the hygroscopic growth of particles. The measurement speed of the HFIMS is about one order of magnitude faster than that of the conventional HTDMA. Here, a data inversion routine is developed to retrieve the growth factor probability density function (GF-PDF) of particles measured by the HFIMS. The inversion routine considers the transfer functions of the upstream DMA and the downstream water-based fast integrated mobility spectrometer (FIMS), and derives the GF-PDF that reproduces the measured responses of the HFIMS. The performance of the inversion routine is examined using ambient measurements with different assumptions for the spectral shape of the particle GF-PDF (multimodal lognormal or piecewise linear). The influences of the data inversion parameters and counting statistics on the inverted GF-PDFs were further investigated, and an approach to determine the optimized inversion parameters is presented.

47 OTHER INSTRUMENTATION↗

Human factors issues in the use of artificial intelligence in air traffic control. October 1990 Workshop

The objective of the workshop was to explore the role of human factors in facilitating the introduction of artificial intelligence (AI) to advanced air traffic control (ATC) automation concepts. AI is an umbrella term which is continually expanding to cover a variety of techniques where machines are performing actions taken based upon dynamic, external stimuli. AI methods can be implemented using more traditional programming languages such as LISP or PROLOG, or they can be implemented using state-of-the-art techniques such as object-oriented programming, neural nets (hardware or software), and knowledge based expert systems. As this technology advances and as increasingly powerful computing platforms become available, the use of AI to enhance ATC systems can be realized. Substantial efforts along these lines are already being undertaken at the FAA Technical Center, NASA Ames Research Center, academic institutions, industry, and elsewhere. Although it is clear that the technology is ripe for bringing computer automation to ATC systems, the proper scope and role of automation are not at all apparent. The major concern is how to combine human controllers with computer technology. A wide spectrum of options exists, ranging from using automation only to provide extra tools to augment decision making by human controllers to turning over moment-by-moment control to automated systems and using humans as supervisors and system managers. Across this spectrum, it is now obvious that the difficulties that occur when tying human and automated systems together must be resolved so that automation can be introduced safely and effectively. The focus of the workshop was to further explore the role of injecting AI into ATC systems and to identify the human factors that need to be considered for successful application of the technology to present and future ATC systems.

Hockaday, Stephen↗

Resilient Information Architecture Platform for Smart Grid (RIAPS)

A number of emerging trends will substantially alter the operation and control of the electric grid over the next several decades. These trends include ensuring resiliency under severe weather events, increasing integration of renewable electricity generation, supporting changing electricity demand patterns, and the improving cost effectiveness of distributed energy resources. To address these challenges, the future “Smart Grid” management will need to transition from centralized to coordinated distributed control paradigm. Reliable operation of the Smart Grid depends on distributed intelligence realized through software applications that run on distributed computing devices attached to the power system to collect data and collaboratively manage resources. However, much of the existing software for Smart Grid-enabled devices is either proprietary or developed with custom solutions, which limits interoperability among the heterogeneous devices and hinders the ability to manage system-level reliability, security, and resiliency requirements. Additionally, this approach makes Smart Grid applications hard to maintain, evolve, verify, and replace; resulting in high development and deployment costs. Further development of the Smart Grid requires a reusable software base-layer to move from hard-coded functionality to a plug-and-play architecture capable of managing system-level objectives and constraints in addition to providing consistent common services across heterogeneous devices and applications. Vanderbilt University, in collaboration with North Carolina State University and Washington State University has developed a foundation ‘software platform’ for developing and deploying robust, reliable, effective and secure software applications for the Smart Grid. The Resilient Information Architecture Platform for the Smart Grid (RIAPS) provides core services for building effective and powerful smart grid applications. It offers unique services for real-time data dissemination, fault tolerance, and coordination across apps distributed over the network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lab-Scale Cable-Driven Parallel Robot Prototype for Automated Prefabricated Component Manipulation

This paper presents the design and evaluation of a lab-scale cable-driven parallel robot (CDPR) developed as a flexible platform for automated installation of prefabricated components onto exterior building envelopes. Traditional manual installation methods for prefabricated components, which depend on scaffolding, cranes, cherry pickers, and verbal coordination, are not only labor-intensive and error-prone but also face significant limitations in dense urban environments due to site access constraints. To address these challenges, we developed a lab-scale CDPR platform capable of autonomously transporting building envelope components from a designated pickup zone to their target installation location, minimizing the need for human intervention. This study describes the system’s mechanical design, actuation architecture, real-time feedback system, and control strategy of the CDPR, and evaluates its performance in a laboratory environment. The robot’s actuation system uses torque control for end-effector manipulation. The robot’s real-time pose feedback comes from a construction-grade total station and a wireless inertial measurement unit (IMU), which together support precise end-effector control. Experimental results demonstrate the successful integration of the hardware, sensing, state estimation, and control subsystems. Preliminary tests showed that our lab-scale prototype can position the end effector with an error of less than 3 mm, which is a level of precision not previously achieved by existing CDPRs in construction applications. The key findings are twofold: (1) torque-only control is necessary but not sufficient for minimizing final pose error, and (2) incorporating real-time pose feedback can achieve the desired placement accuracy.

Liu, Yifang [Oak Ridge National Laboratory (ORNL),↗

WaterTAP v1.0.0

WaterTAP is a new open source library of water-specific models built on the IDAES Integrated Platform to support the design and optimization of integrated water treatment systems, improve existing systems and enable the analysis of new designs incorporating emerging technologies. WaterTAP enables advanced modeling and optimization for: conceptual and multiscale design, dynamics and model predictive control of water systems and networks.

Beattie, KeithS↗