Fe{sub 3}O{sub 4}/Zeolite nanocomposites synthesized by microwave assisted coprecipitation and its performance in reducing viscosity of heavy oil

Fe{sub 3}O{sub 4}/Zeolite nanocomposites have been synthesized via microwave assisted coprecipitation method and show to be efficient in reducing viscosity of heavy oil compared to other Fe{sub 3}O{sub 4}/Zeolite nanocomposites prepared by conventional method. The following precursors such as FeCl{sub 3}⋅6H{sub 2}O, FeSO{sub 4}⋅7H{sub 2}O, NH{sub 4}OH, and natural zeolite of heulandite type were used in the sample preparation. In this study, the effect of Fe{sub 3}O{sub 4} composition in the composite and microwave time heating were investigated. Fe{sub 3}O{sub 4}/Zeolite nanocomposites were then characterized to study the influence on crystal structures, morphology and physicochemical properties. The characterization techniques include X-ray diffraction (XRD), scanning electron microscopy (SEM) and nitrogen physisorption. The results show that by increasing the microwave heating time, the degree of nanocomposite intergrowth can be enhanced. The nanocomposite was tested in catalytic aquathermolysis of heavy oil at 200°C for 6 h and the Fe{sub 3}O{sub 4}/zeolite of 1 to 4 ratios performed the highest viscosity reduction of heavy oil reaching 92%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation between structural, magnetic, and dielectric properties of manganese substituted cobalt ferrite

Manganese (Mn) substituted cobalt ferrites (CoFe{sub 2−x}Mn{sub x}O{sub 4}, referred to CFMO) were synthesized and their structural, magnetic, and dielectric properties were evaluated. X-ray diffraction measurements coupled with Rietveld refinement indicate that the CFMO materials crystallize in the inverse cubic spinel phase. Temperature (T = 300 K and 10 K) dependent magnetization (M(H)) measurements indicate the long range ferromagnetic ordering in CoFe{sub 2−x}Mn{sub x}O{sub 4} (x = 0.00–0.15) ferrites. The cubic anisotropy constant (K{sub 1}(T)) and saturation magnetization (M{sub s}(T)) were derived by using the “law of approach” to saturation that describes the field dependence of M(H) for magnetic fields much higher than the coercive field (H{sub c}). Saturation magnetization (M{sub s}), obtained from the model, decreases with increasing temperature. For CoFe{sub 2}O{sub 4}, M{sub s} decreases from 3.63 μ{sub B} per formula unit (f.u.) to 3.47 μ{sub B}/f.u. with increasing temperature from 10 to 300 K. CFMO (0.00–0.15) exhibit the similar trend while the magnitude of M{sub s} is dependent on Mn-concentration. M{sub s}-T functional relationship obeys the Bloch's law. The lattice parameter and magnetic moment calculated for CFMO reveals that Mn ions occupying the Fe and Co position at the octahedral site in the inverse cubic spinel phase. The structure and magnetism in CFMO are further corroborated by bond length and bond angle calculations. The dielectric constant dispersion of CFMO in the frequency range of 20 Hz–1 MHz fits to the modified Debye's function with more than one ion contributing to the relaxation. The relaxation time and spread factor derived from modeling the experimental data are ∼10{sup −4} s and ∼0.35(±0.05), respectively.

36 MATERIALS SCIENCE↗

Microarcsecond relative astrometry from the ground with a diffractive pupil

The practical use of astrometry to detect exoplanets via the reflex motion of the parent star depends critically on the elimination of systematic floors in imaging systems. In the diffractive pupil technique proposed for space-based detection of exo-earths, extended diffraction spikes generated by a dotted primary mirror are referenced against a wide-field grid of background stars to calibrate changing optical distortion and achieve microarcsecond astrometric precision on bright targets (Guyon et al. 2010). We describe applications of this concept to ground-based uncrowded astrometry using a diffractive, monopupil telescope and a wide-field camera to image as many as {approx}4000 background reference stars. Final relative astrometric precision is limited by differential tip/tilt jitter caused by high altitude layers of turbulence. A diffractive 3-meter telescope is capable of reaching {approx}35 {micro}as relative astrometric error per coordinate perpendicular to the zenith vector in three hours on a bright target star (I < 10) in fields of moderate stellar density ({approx}40 stars arcmin{sup -2} with I < 23). Smaller diffractive apertures (D < 1 m) can achieve 100-200 {micro}as performance with the same stellar density and exposure time and a large telescope (6.5-10 m) could achieve as low as 10 {micro}as, nearly an order of magnitude better than current space-based facilities. The diffractive pupil enables the use of larger fields of view through calibration of changing optical distortion as well as brighter target stars (V < 6) by preventing star saturation. Permitting the sky to naturally roll to average signals over many thousands of pixels can mitigate the effects of detector imperfections.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface Modification of Nickel Foams by a Slurry Aluminizing Process

A novel slurry-based process for aluminizing nickel foams while improving the mechanical properties and conserving the excellent ductility is reported. Cellular unalloyed nickel foams with 92% porosity and uniform pore size and distribution were used as a starting material. Several slurries of different compositions were examined to investigate the possibility of developing an aluminide-nickel intermetallic coating on a Ni foam without considerably degrading the original ductile properties of the foam. The process temperature was varying from 400 to 850 deg. C and the process holding time was ranging between 2h to 6h. Scanning electron microscopy with an energy dispersive X-ray spectrometry and X-Ray diffraction were applied to assess the effectiveness of the aluminizing process and determine both the optimum parameters of the procedure (slurry composition, holding temperature and time) and the concentration profiles across the coating cross-section. The mechanical behavior of the aluminized Ni-foams was evaluated by the conduction of micro-tension tests. The resulting Ni-foams after aluminization retain the pore structure of original Ni-foams and present a thick outer surface layer which consists of a range of aluminide phases. The mechanical properties of the Ni-foams aluminized in low process temperature were insignificantly affected.

36 MATERIALS SCIENCE↗

Synthesis of lithium cobalt oxide by single-step soft hydrothermal method

Lithium cobalt double oxide LiCoO{sub 2} was synthesized at 220 Degree-Sign C by soft hydrothermal method using Co(OH){sub 2} and LiOH as precursors, LiOH/NaOH as mineralizers and H{sub 2}O{sub 2} as oxidant. The soft hydrothermal synthesis method offers the dual advantage of a much lower synthesis time and a higher purity in comparison with other synthesis methods. The compound was identified by X-ray diffraction and its purity was checked by magnetic and electron magnetic resonance measurements. The grain morphology was studied by Scanning Electron Microscopy and an exponential growth of particle size with synthesis time was observed. - Graphical abstract: Concave cuboctohedrons obtained after 60 h reaction time. Highlights: Black-Right-Pointing-Pointer An optimized soft hydrothermal method for a fast synthesis of high purity LiCoO{sub 2} compound is reported. Black-Right-Pointing-Pointer Both lamellar and cuboctahedral particles could be stabilized. Black-Right-Pointing-Pointer Secondary phases content is lower than 0.1%. Black-Right-Pointing-Pointer Close to surface defects were evidenced using EMR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Breakdown of partial conservation of axial current in diffractive neutrino interactions

We test the hypothesis of partially conserved axial current in high-energy diffractive neutrino production of pions. Since the pion pole contribution to the Adler relation (AR) is forbidden by conservation of the lepton current, the heavier states, like the a{sub 1} pole, {rho}-{pi} cut, etc., control the lifetime of the hadronic fluctuations of the neutrino. We evaluate the deviation from the AR in diffractive neutrino production of pions on proton and nuclear targets. At high energies, when all the relevant time scales considerably exceed the size of the target, the AR explicitly breaks down on an absorptive target, such as a heavy nucleus. In this regime, close to the black disk limit, the off-diagonal diffractive amplitudes vanish, while the diagonal one, {pi}{yields}{pi}, which enters the AR, maximizes and saturates the unitarity bound. At lower energies, in the regime of short lifetime of heavy hadronic fluctuations the AR is restored, i.e., it is not altered by the nuclear effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated optical signal processing with magnetostatic waves

Magneto-optical devices based on Bragg diffraction of light by magnetostatic waves (MSW's) offer the potential of large time-bandwidth optical signal processing at microwave frequencies of 1 to 20 GHz and higher. A thin-film integrated-optical configuration, with the interacting MSW and guided-optical wave both propagating in a common ferrite layer, is necessary to avoid shape-factor demagnetization effects. The underlying theory of the MSW-optical interaction is outlined, including the development of expressions for optical diffraction efficiency as a function of MSW power and other relevant parameters. Bradd diffraction of guided-optical waves by transversely-propagating magnetostatic waves and collinear TE/TM mode conversion included by MSW's have been demonstrated in yttrium iron garnet (YIG) thin films. Diffraction levels as large as 4% (7 mm interaction length) and a modulation dynamic range of approx 30 dB have been observed. Advantages of these MSW-based devices over the analogous acousto-optical devices include: much greater operating frequencies, tunability of the MSW dispersion relation by varying either the RF frequency or the applied bias magnetic field, simple broad-band MSW transducer structures (e.g., a single stripline), and the potential for very high diffraction efficiencies.

Fisher, A. D.↗

CRDS with a VECSEL for broad-band high sensitivity spectroscopy in the 2.3 μm window

The integration of an industry ready packaged Sb-based Vertical-External-Cavity Surface-Emitting-Laser (VECSEL) into a Cavity Ring Down Spectrometer (CRDS) is presented. The instrument operates in the important 2.3 μm atmospheric transparency window and provides a high sensitivity (minimum detectable absorption of 9 × 10{sup −11} cm{sup −1}) over a wide spectra range. The VECSEL performances combine a large continuous tunability over 120 cm{sup −1} around 4300 cm{sup −1} together with a powerful (∼5 mW) TEM{sub 00} diffraction limited beam and linewidth at MHz level (for 1 ms of integration time). The achieved performances are illustrated by high sensitivity recordings of the very weak absorption spectrum of water vapor in the region. The developed method gives potential access to the 2-2.7 μm range for CRDS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Benchmark Study on Casting Residual Stress

Stringent regulatory requirements, such as Tier IV norms, have pushed the cast iron for automotive applications to its limit. The castings need to be designed with closer tolerances by incorporating hitherto unknowns, such as residual stresses arising due to thermal gradients, phase and microstructural changes during solidification phenomenon. Residual stresses were earlier neglected in the casting designs by incorporating large factors of safety. Experimental measurement of residual stress in a casting through neutron or X-ray diffraction, sectioning or hole drilling, magnetic, electric or photoelastic measurements is very difficult and time consuming exercise. A detailed multi-physics model, incorporating thermo-mechanical and phase transformation phenomenon, provides an attractive alternative to assess the residual stresses generated during casting. However, before relying on the simulation methodology, it is important to rigorously validate the prediction capability by comparing it to experimental measurements. In the present work, a benchmark study was undertaken for casting residual stress measurements through neutron diffraction, which was subsequently used to validate the accuracy of simulation prediction. The stress lattice specimen geometry was designed such that subsequent castings would generate adequate residual stresses during solidification and cooling, without any cracks. The residual stresses in the cast specimen were measured using neutron diffraction. Considering the difficulty in accessing the neutron diffraction facility, these measurements can be considered as benchmark for casting simulation validations. Simulations were performed using the identical specimen geometry and casting conditions for predictions of residual stresses. The simulation predictions were found to agree well with the experimentally measured residual stresses. The experimentally validated model can be subsequently used to predict residual stresses in different cast components. This enables incorporation of the residual stresses at the design phase along with external loads for accurate predictions of fatigue and fracture performance of the cast components.

36 MATERIALS SCIENCE↗

Acousto-Optic Diffraction in Paratellurite by a Slow Acoustic Mode. Increase of Diffraction Efficiency of Divergent Light

Peculiarities of anisotropic acousto-optic Bragg diffraction in paratellurite by a slow acoustic wave have been considered. The ranges of frequency-angular dependences have been found, in which effective diffraction occurs, and their practical relevance has been formulated. The numerical values for light radiation with a wavelength of 1.06 μm have been obtained. We have proposed the method of enhancement of a diffraction efficiency of divergent optical radiation, which in turn leads to the increase of the response time of an acousto-optical modulator. The method is based on a multifrequency electric control of the acousto-optical modulator. We have shown experimentally that, as distinct from the single-frequency control, a considerable intensity suppression of the zero diffraction order from 30 to 8% is achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of crystallization time on the physico-chemical and catalytic properties of the hierarchical porous materials

A series of hierarchical porous materials were prepared by a dual template method. The effect of different crystallization time on the channel architecture, morphology, acid performance of the hierarchical porous materials was investigated. X-ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy, nitrogen adsorption and {sup 27}Al nuclear magnetic resonance were performed to obtain information on the physico-chemical properties of the materials. It was shown that the change in crystallization time could influence the structure/texture and surface acid properties of the hierarchical porous materials. In addition, alkylation of phenol with tert-butanol reaction was carried out to investigate the catalytic performance of the hierarchical porous materials. The results showed that the catalytic activity of the hierarchical porous materials and the selectivity to the bulkly product 2,4-di-tert-butyl-phenol decreased with processing time.

36 MATERIALS SCIENCE↗

Method for phase retrieval to reduce a sampling requirement when imaging a dynamic process

A method for retrieving phase information in a coherent diffraction imaging process includes acquiring a plurality of 3D data sets, each 3D data set corresponding to one of a plurality of time states, and reconstructing a 3D image of the object at a given time state using the 3D data set from all of the time states. Each 3D data set is acquired by: illuminating an object positioned in a first position with a coherent beam; measuring a first 2D diffraction pattern using an area detector; rotating the object around a tilt axis thereof to a second position that is different from the first position; re-illuminating the object positioned in the second position with the coherent beam; re-measuring a second 2D diffraction pattern using the area detector; and repeating the rotating, re-illuminating and re-measuring steps such that each 3D data set includes a predetermined number of diffraction patterns.

36 MATERIALS SCIENCE↗

Dynamical Slowing-Down in an Ultrafast Photoinduced Phase Transition

Complex systems, which consist of a large number of interacting constituents, often exhibit universal behavior near a phase transition. A slowdown of certain dynamical observables is one such recurring feature found in a vast array of contexts. This phenomenon, known as critical slowing-down, is well studied mostly in thermodynamic phase transitions. However, it is less understood in highly nonequilibrium settings, where the time it takes to traverse the phase boundary becomes comparable to the timescale of dynamical fluctuations. Using transient optical spectroscopy and femtosecond electron diffraction, we studied a photoinduced transition of a model charge-density-wave (CDW) compound LaTe 3 . We observed that it takes the longest time to suppress the order parameter at the threshold photoexcitation density, where the CDW transiently vanishes. Here, this finding can be captured by generalizing the time-dependent Landau theory to a system far from equilibrium. The experimental observation and theoretical understanding of dynamical slowing-down may offer insight into other general principles behind nonequilibrium phase transitions in many-body systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Milli-Arcsecond (MAS) Imaging with SmallSat Enabled Super-resolution

The objective of this project is to demonstrate a new imaging technology with unprecedented capabilities for scientific exploration. This technology innovation will enable extremely high-resolution imaging capability, otherwise unattainable with conventional approaches. It is based on a unique combination of novel diffractive optical sensing (photon sieve), advanced image processing, and small satellite formation flying. The spatial resolution of current solar instruments are more than 100 times coarser than the size of energy dissipation features in coronal heating (<100 km) since conventional optics cannot be figured to near diffraction-limited accuracy at extreme ultraviolet (EUV) wavelengths. This project will demonstrate the feasibility of imaging of a few milli-arcseconds (MAS) to study the structure and development of these dissipation regions.

Farzad Kamalabadi↗

Variable-beamwidth monopulse antennas

The merits of nine methods for zooming microwave amplitude-sensing monopulse antenna patterns are discussed. Of these, six are directly related to the TDRSS (Tracking Data Relay Satellite System) and are compatible with a deployable-mesh pseudo-paraboloidal main reflector. The remaining three methods utilize radically different geometrical configurations that depart considerably from the TDRSS parameters existing at this time. Preservation of the monopulse postulates is considered to be of prime importance for any variable-beamwidth candidate, however, it is allowed that approximate satisfaction of the postulates should be accepted for practical reasons. All of the methods discussed admit free choice of the polarization state, and the zooming function is never predicated on polarization. Exploration of the zooming techniques was carried out almost entirely by means of the Kirchhoff-Kottler vector diffraction program. The program generates electric and magnetic field intensity, associated phase, and time-average Poynting vector power flow in the intermediate near-field and far-field zones in both receive and transmit modes of operation. A few of the concepts have been verified experimentally with excellent agreement between theory and practice.

Schmidt, R. F.↗

Coherent X-Ray Diffraction Imaging with Nanofocused Illumination

Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions {approx_equal}100x100 nm{sup 2}) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Random forest prediction of crystal structure from electron diffraction patterns incorporating multiple scattering

Diffraction is the most common method to solve for unknown or partially known crystal structures. However, it remains a challenge to determine the crystal structure of a new material that may have nanoscale size or heterogeneities. Here, in this study, we train an architecture of hierarchical random forest models capable of predicting the crystal system, space group, and lattice parameters from one or more unknown two-dimensional electron diffraction patterns. Our initial model correctly identifies the crystal system of a simulated electron diffraction pattern from a 20-nm-thick specimen of arbitrary orientation 67% of the time. We achieve a topline accuracy of 79% when aggregating predictions from ten patterns of the same material but different zone axes. The space group and lattice predictions range from 70% to 90% accuracy and median errors of 0.01-0.5Å, respectively, for cubic, hexagonal, trigonal, and tetragonal crystal systems while being less reliable on orthorhombic and monoclinic systems. We apply this architecture to a four-dimensional scanning transmission electron microscopy scan of gold nanoparticles, where it accurately predicts the crystal structure and lattice constants. These random forest models can be used to significantly accelerate the analysis of electron diffraction patterns, particularly in the case of unknown crystal structures. Additionally, due to the speed of inference, these models could be integrated into live transmission electron microscopy experiments, allowing real-Time labeling of a specimen.

36 MATERIALS SCIENCE↗

Grazing-Angle Neutron Diffraction Study of the Water Distribution in Membrane Hemifusion: From the Lamellar to Rhombohedral Phase

The water distribution between lipid bilayers is important in understanding the role of the hydration force at different steps of the membrane fusion pathway. Here in this study, we used grazing-angle neutron diffraction to map out the water distribution in lipid bilayers transiting from a lamellar structure to the hemifusion “stalk” structure in a rhombohedral phase. Under osmotic pressure exerted by different levels of relative humidity, the lipid membrane sample was maintained in equilibrium at different lattices suitable for neutron diffraction. The D 2 O used to hydrate the lipid membrane sample stood out from the lipid in the reconstructed structure because of its much higher coherent neutron scattering length density. The density map indicates that water dissociated from the headgroup in the lamellar phase. In the rhombohedral phase, water was significantly reduced and was squeezed into pockets around the stalk. This study complements earlier structural studies by grazing-angle X-ray diffraction, which is sensitive to only the parts of the structure with high electron density (such as phosphors). The experiment also demonstrated that the recently developed time-of-flight small-angle neutron scattering beamline at the Spallation Neutron Source is suitable for grazing-angle neutron diffraction to provide the structures of large unit cells on the order of a few nanometers, such as biomembrane structures.