Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Org.Lcsim: Event Reconstruction in Java

Maximizing the physics performance of detectors being designed for the International Linear Collider, while remaining sensitive to cost constraints, requires a powerful, efficient, and flexible simulation, reconstruction and analysis environment to study the capabilities of a large number of different detector designs. The preparation of Letters Of Intent for the International Linear Collider involved the detailed study of dozens of detector options, layouts and readout technologies; the final physics benchmarking studies required the reconstruction and analysis of hundreds of millions of events. We describe the Java-based software toolkit (org.lcsim) which was used for full event reconstruction and analysis. The components are fully modular and are available for tasks from digitization of tracking detector signals through to cluster finding, pattern recognition, track-fitting, calorimeter clustering, individual particle reconstruction, jet-finding, and analysis. The detector is defined by the same xml input files used for the detector response simulation, ensuring the simulation and reconstruction geometries are always commensurate by construction. We discuss the architecture as well as the performance.

43 PARTICLE ACCELERATORS↗

Measurement and applications: Exploring the challenges and opportunities of hierarchical federated learning in sensor applications

Sensor applications have become ubiquitous in modern society as the digital age continues to advance. AI-based techniques (e.g., machine learning) are effective at extracting actionable information from large amounts of data. An example would be an automated water irrigation system that uses AI-based techniques on soil quality data to decide how to best distribute water. However, these AI-based techniques are costly in terms of hardware resources, and Internet-of-Things (IoT) sensors are resource-constrained with respect to processing power, energy, and storage capacity. These limitations can compromise the security, performance, and reliability of sensor-driven applications. To address these concerns, cloud computing services can be used by sensor applications for data storage and processing. Unfortunately, cloud-based sensor applications that require real-time processing, such as medical applications (e.g., fall detection and stroke prediction), are vulnerable to issues such as network latency due to the sparse and unreliable networks between the sensor nodes and the cloud server [1]. As users approach the edge of the communications network, latency issues become more severe and frequent. A promising alternative is edge computing, which provides cloud-like capabilities at the edge of the network by pushing storage and processing capabilities from centralized nodes to edge devices that are closer to where the data are gathered, resulting in reduced network delays [2], [3].

Po-Leen Ooi, Melanie↗

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION↗

TALENT User's Manual

The Ground-Based Monitoring R and E Component Evaluation project performs testing on the hardware components that make up Seismic and Infrasound monitoring systems. The majority of the testing is focused on the Digital Waveform Recorder (DWR), Seismic Sensor, and Infrasound Sensor. The software tool used to capture and analyze the data collected from testing is called TALENT: Test and Analysis Evaluation Tool. This document is the manual for using TALENT. Other reports document the testing procedures that are in place (Kromer, 2007) and the algorithms employed in the test analysis (Merchant, 2011).

99 GENERAL AND MISCELLANEOUS↗

Summary Statistics for LC_TA03_130719: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_TA03_130719, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MP03_130620: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MP03_130620, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MH03_130828: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MH03_130828, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MH01_130826: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MH01_130826, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MH02_130827: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MH03_130827, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MC03_130806: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MC03_130806, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MC02_130701: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MC02_130701, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_ST01_130731: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_ST01_130731, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_SH02_130820: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_SH02_130820, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT03_130730: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT03_130730, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_SH01_130819: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_SH01_130819, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT01_130725: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT01_130725, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT02_130729: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT02_130729, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT02_130812: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT02_130812, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗