Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy efficiency programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the performance of the drive system and diffuser of the Langley unitary plan wind tunnel

A broad program was initiated at the Langley Research Center in 1973 to reduce the energy consumption of the laboratory. As a part of this program, the performance characteristics of the Unitary Plan Wind Tunnel were reexamined to determine if potential methods for incresing the operating efficiencies of the tunnel could be formulated. The results of that study are summarized. The performance characteristics of the drive system components and the variable-geometry diffuser system of the tunnel are documented and analyzed. Several potential methods for reducing the energy requirements of the facility are discussed.

Hasel, L. E.↗

Computationally Efficient Control Co-Design Optimization Framework with Mixed-Fidelity Fluid and Structure Analysis: OpenTurbineCoDe (OTCD) - ARPA-E ATLANTIS Phase I Project (Final Technical Report)

The goal of the Department of Energy (DOE) Advanced Research Projects Agency-Energy (ARPA-E) Aerodynamic Turbines Lighter and Afloat with Nautical Technologies and Integrated Servo-control (ATLANTIS) Program is to develop new technologies for floating offshore wind turbines, or wind farms, using the discipline of control co-design (CCD.) In this context, our goal is to develop a computationally efficient optimization framework for design of floating offshore wind turbines. Our specific aim is to utilize high-fidelity structural, aerodynamic, aero-structural tools, and to derive control-oriented reduced- or low-order models directly from the high-fidelity tools. We proposed a mixed-fidelity modeling approach which means that we are also using low- and mid-fidelity tools when necessary. This research is conducted by a multidisciplinary team consisting of Rutgers University, University of Michigan, Brigham Young University, and the National Renewable Energy Laboratory (NREL). The computational framework, called OpenTurbineCoDe, is designed to integrate, where possible, traditional structural, aerodynamic, aeroelastic models (e.g., OpenFAST) and advanced control algorithms with higher fidelity simulation tools including Reynolds-averaged Navier–Stokes (RANS) solvers, and three-dimensional structural finite element solvers. All the high-fidelity tools used in this research provide numerically exact gradients to facilitate both efficient optimization and local linearization for control implementation.

17 WIND ENERGY↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An integrated approach to optimizing concentration shock wave electrodialysis using 2D multicell simulation and response surface models

Shock wave electrodialysis (SWED) is a highly promising technique for energy-efficient ion separation in the context of a circular economy. This paper presents a approach way of modeling and improving SWED using a two-dimensional multicell model combined with the COMSOL program and response surface methodology. The model integrates the Nernst-Planck equation, Darcy's law, and first-order electroosmosis to examine the local concentration, flux of ionic species, distribution of current, and velocity of flow in SWED cells under various operating conditions. We first illustrate the clear depiction of concentration, velocity, and electric potential distribution through contours which aids in identifying optimal operating conditions and designing scalable SWED systems. The results emphasize the significance of surface charge density and voltage in influencing the features of shock waves for obtaining effective ion separation while optimizing energy consumption and improving current efficiency by controlling the retention time of feed flow. Here, this study defines two crucial characteristics of shock waves, namely the length of the flat depletion zone of a fully developed shock wave (shock wave height) and the distance of shock wave propagation (shock wave length). These properties significantly impact separation performance, as determined by the simulation results. Additionally, the response surface methodology is incorporated with the COMSOL models to develop predictive models and graph responses, enabling a more comprehensive understanding of the interactions between parameters and performance indicators, such as removal ratio, energy consumption, and water recovery. Finally, this work suggests design tactics for expanding SWED processes and outlines potential areas for further research. This research provides valuable insights into the prospective applications, design optimization, and scalability of SWED in the field of electrokinetic separation technologies for green chemistry and a circular economy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Energy Storage Capacity Low Cost Iron Flow Battery

A new flow battery was proposed that utilizes low cost materials: iron as the only active element, cheap aqueous electrolytes, and inexpensive separators. During charging, ferrous iron (Fe 2+ ) is oxidized to ferric iron (Fe 3+ ) at the positive electrode while it (Fe 2+ ) is reduced to form iron metal (Fe 0 ) at the negative electrode. Because iron is plated at the negative electrode during charging, conventional electrode structures couple the energy storage capacity and the power rating of the battery. In order to decouple the energy and power ratings and regain the economic advantages of a flow battery, a slurry electrode design was proposed for use as the negative electrode. The slurry electrode is made by flowing electrically conductive particles in an electrolyte containing the dissolved iron species. On charging, iron is plated onto the particles. The particles can then carry the iron metal out of the cell to be stored in external reservoirs. This project looked to develop a slurry for the negative electrode of the all-iron flow battery that can operate at 200 mA/cm 2 with <100 mV overpotential, be pumped with parasitic energy costs < 10%, and promote plating on the particles. A scalable and stackable cell design of 1100 cm 2 was developed. The project was initially under contract in mid-January 2013. The project was converted from a one-year proof of concept seedling to an additional two-year program, then extended with an 18-month plus-up, and finally with an additional 6-month approved cost-overrun. During the seeding project, the concept of plating on carbon particles in a slurry was demonstrated. However, this was accomplished with high-cost multi-walled carbon nanotubes as the slurry material. The following two-year program discovered several low-cost carbon blacks that could also be used in this application. These findings were supported by an analysis that demonstrated the effectiveness of the carbon that takes into account not just the effective electronic conductivity of the slurry, but also the surface area per volume of the slurry. It was demonstrated that stable, flowable slurries could be created with these carbons, even when the carbons where fully loaded with iron during charging. During the two-year program, laboratory-scale 50 cm 2 single-cells demonstrated charge-discharge cycling at current densities of 150 mA/cm 2 and energy efficiencies of >50%. Meanwhile, cost modeling continued to show promise for this energy storage approach. Following the conversion period, the overall objective of the nominally 18-month plus up period was to close the technical gap of a 25X scale-up and reduce risk to enable commercial investment required to develop a slurry iron flow battery product. A specific objective was to demonstrate 150 cycles of performance exceeding 70% energy efficiency with a 10-cell stack of 1156 cm 2 cells operating at 100 mA/cm 2 . The 10-cell short stack was designed to have a power delivery rating of approximately 1 kW, which represents a size commensurate with the requirements of our commercialization partner at that time. A complete battery support system for the full-size cell was designed, fabricated, and tested. This includes pumps (multiple types were considered, and constant volume hose pumps were found to be acceptable for performance and cost), electrolyte rebalance reactor, and sensors and control systems. The support system proved to be well-behaved and worked well. A new low-cost membrane was developed for this system based on a microporous polymer support with a layer of hydrogel polymer. The membrane had low resistivity, and significantly reduced pressure driven fluid flow across the membrane (as compared to the un-coated microporous support). This membrane approach was scaled-up in conjunction with a commercial toll coating company, and a large amount of membrane was manufactured to support large cell and stack testing. A new concept for an electrolyte rebalance reactor to react hydrogen gas from the negative electrolyte (from plating inefficiency) with excess ferric ion in the positive electrolyte was developed. This design was very simple, low cost, and effective. The full scale 1156 cm 2 single-cell was designed, modeled, fabricated and tested. Modeling showed that uniform flow-distribution should be obtained with the designed flow distributor. The design took into consideration the need to stack the cells, and components were fabricated for a ten-cell stack. Testing of the cell for charge and discharge demonstrated current densities of 50 mA/cm 2 with efficiencies of 50%. However, optimization and long cycling could not be accomplished because the slurry electrode would plug within the cell and block the flow. This would shut down the cell after several charge-discharge cycles. Various approaches were pursued to address this problem with some progress. However, there was not adequate time to find solutions to the problem although several promising approaches were identified for future work. The final deliverable for this proposed 18-month effort was to be a 1 kW, 6 kWh slurry flow battery, with complete balance of plant, ready for testing at an ARPA-E ‘Charges’ site with an estimated capital cost less than $\$ $45/kWh for a six-hour system (excluding power electronics). The deliverable milestone was not achieved for reasons mentioned above related to the slurry plugging. At the completion of this project, it was determined that the cost targets are achievable. The cost estimate for a 1 MW system with a one-hour capacity was estimated at $\$ $140/kWh (including power electronics) and for a six-hour system was estimated at $\$ $40/kWh (including power electronics). These costs include the battery, the balance of plant, the power conditioning and a concrete pad. This program resulted in three patents including the slurry-based iron flow battery, the rebalance reactor, and the membrane separator. At the time of this report, slurry-based iron flow battery patents have been issued in the US, China, Japan, Korea, and Europe. The other patent applications were under various stages of examination. A licensee was identified and the company initiated a scale-up and development program to take this technology to the marketplace, and CWRU staff have transferred their know-how and knowledge base to the company. This technology will enhance the economic and energy security of the United States by enabling the use of intermittent renewable energy technology, such as wind and solar power, as dispatchable resources. This report summarizes the results of this research and development program.

25 ENERGY STORAGE↗

Wood Pellet-Fired Biomass Boiler Project at the Ketchikan Federal Building

Biomass boiler systems have existed for many years, but the technology has advanced in recent decades and can now provide automated and efficient operation for a relatively modest investment. Key advances in system monitoring and control allow for lower operating costs, since the control systems run all aspects of the boiler, including feed, load reduction and even tube cleaning. These advances have made such systems economical on a small scale in situations where inexpensive fuels like natural gas are not available. This creates an opportunity for building operators in remote, cold-climate locations to reduce the use of expensive fuels for heating buildings. GSA Region 10 installed the system at the federal building in Ketchikan, Alaska and submitted the project to the Green Proving Ground (GPG) program. GSA's GPG program contracted with the National Renewable Energy Laboratory (NREL) to assess the installation and the technology. The system serves as a demonstration to assess actual system efficiencies, as well as operating characteristics and financial benefits. In addition to installation and operational issues, the project team/researchers examined other issues, including fuel transportation costs, building energy savings, and overall economics.

09 BIOMASS FUELS↗

Low-Cost High-Concentration Photovoltaic Systems for Utility Power Generation

Under DOE's Technology Pathway Partnership (TPP) program, Amonix, Inc. developed a new generation of high-concentration photovoltaic systems using multijunction technology and established the manufacturing capacity needed to supply multi-megawatt power plants built using the new Amonix 7700-series solar energy systems. For this effort, Amonix Collaborated with a variety of suppliers and partners to complete project tasks. Subcontractors included: Evonik/Cyro; Hitek; the National Renewable Energy Laboratory (NREL); Raytech; Spectrolab; UL; University of Nevada, Las Vegas; and TUV Rheinland PTL. The Amonix TPP tasks included: Task 1: Multijunction Cell Optimization for Field Operation, Task 2: Fresnel Lens R&D, Task 3: Cell Package Design & Production, Task 4: Standards Compliance and Reliability Testing, Task 5: Receiver Plate Production, Task 6: MegaModule Performance, Task 7: MegaModule Cost Reduction, Task 8: Factory Setup and MegaModule Production, Task 9: Tracker and Tracking Controller, Task 10: Installation and Balance of System (BOS), Task 11: Field Testing, and Task 12: Solar Advisor Modeling and Market Analysis. Amonix's TPP addressed nearly the complete PV value chain from epitaxial layer design and wafer processing through system design, manufacturing, deployment and O&M. Amonix has made progress toward achieving these reduced costs through the development of its 28%+ efficient MegaModule, reduced manufacturing and installation cost through design for manufacturing and assembly, automated manufacturing processes, and reduced O&M costs. Program highlights include: (1) Optimized multijunction cell and cell package design to improve performance by > 10%; (2) Updated lens design provided 7% increased performance and higher concentration; (3) 28.7% DC STC MegaModule efficiency achieved in Phase II exceeded Phase III performance goal; (4) New 16' focal length MegaModule achieved target materials and manufacturing cost reduction; (5) Designed and placed into production 25 MW/yr manufacturing capacity for complete MegaModules, including cell packages, receiver plates, and structures with lenses; (6) Designed and deployed Amonix 7700 series systems rated at 63 kW PTC ac and higher. Based on an LCOE assessment using NREL's Solar Advisor Model, Amonix met DOE's LCOE targets: Amonix 2011 LCOE 12.8 cents/kWh (2010 DOE goal 10-15); 2015 LCOE 6.4 cents/kWh (2015 goal 5-7) Amonix and TPP participants would like to thank the U.S. Department of Energy Solar Energy Technology Program for funding received under this program through Agreement No. DE-FC36-07GO17042.

14 SOLAR ENERGY↗

Building Energy Codes: Policy Overview and Good Practices

Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Smart Matrix Development for Direct Carbonate Fuel Cell

FCE’s (FuelCell Energy, Inc.) SureSourceTM products based on high-temperature internal-reforming direct carbonate fuel cell (DFC®) technology are striving to meet growing worldwide demand for high-efficiency ultra-clean power for on-site electric and combined heat and power (CHP) generation. It promises ~20% higher energy conversion efficiency than existing technologies and its large-scale deployment would help to reduce GHG (Green House Gas) emission. In this program, FCE, teamed with University of Connecticut (UConn) and Illinois Institute of Technology (IIT), successfully developed an innovative electrolyte matrix (dubbed smart matrix since it promises higher power output, longer service life, and cost reduction gains concurrently) to enable the products to worldwide deployment. The electrolyte membrane (matrix) holds a very important key to fulfill these promises. The matrix, a porous microstructure consisting mainly of ultra-fine sub-micron α-LiAlO 2 powders sandwiched between two electrodes, immobilizes liquid electrolyte, isolates fuel from oxidant and facilitates ionic transport. However, faster coarsening of α-LiAlO 2 at the reducing anode side lowers capillary electrolyte-retention and eventually leads to matrix drying, limiting stack service life. This program, spanning over 3.5 years, successfully developed a high-yield cost-effective commercial-ready smart matrix with robust and stable fine-pore microstructure to enable the SureSource plants meeting DOE 2020 targets for CHP distributed generation fuel cell systems. Fundamental coarsening mechanism was established by investigating in detail the effects of electrolyte chemistry, powder morphology, powder purity, electrolyte chemistry, gas atmosphere and temperature. More stable powders with higher crystallinity, less surface disorder, less metastable impurities, less agglomeration and more uniform particle-size distribution have improved stability. FCE devised an innovative cost-effective additive approach to disrupt the fundamental coarsening process to enhance stability. The smart matrix design was validated in numerous long-term accelerated single cells and several 30kW technology stacks, many operated for >5,000 hours. Manufacturing process was successfully optimized to produce high-yield full-area (1 m 2 ) product-size smart matrices. Field deployment has been initiated. Successful development of this innovative smart matrix enables a quantum jump in useful life (100%) and power output (>20%). These improvements may project to >20% lower COE (Cost of Electricity) making the SureSource highly competitive with U.S. grid electricity cost leading to large-scale deployment, realizing the U.S. Government’s energy, environment, and economic agenda.

03 NATURAL GAS↗

Market Driven Residential Energy Codes: Comparing Performance in a Changing Technological Environment

The research project is undertaken to better understand the changing relationship between the two basic methods of building energy code compliance – prescriptive and performance – and how those methods relate to each other with respect to advancements in building energy computer simulation standards and capabilities. The International Energy Efficiency Code (IECC) is a model code adopted by many jurisdictions across the United States. Historically, the prescriptive compliance methodology has been preferred in most jurisdictions. The prescriptive methodology requires meeting or exceeding specific efficiency minimums for each envelope component. This tends to be a simple method to teach and verify. A more involved prescriptive alternative called the Total UA alternative is sometimes used. This method requires some multiplication, summing, and comparison to compute, so it is done with a fairly simple computer program. However, advances in computer and building energy simulation technology have resulted in increased use of more detailed performance compliance methods. The performance compliance method establishes the annual energy cost threshold via hourly simulation models. The compliance threshold is determined with a comparison building model simulation with geometry similar to the proposed home and with energy feature parameters and efficiencies as specified in the IECC. This project examines relationships between the two methods of building energy code compliance, including: • Overall annual energy use based on utility bill analysis by compliance method • Code official work processes with respect to compliance methods • Gaps and issues associated with building code compliance methods • Simulated energy use difference between compliance methods • Code compliance cost as a function of compliance method • Code compliance labeling effectiveness for high performance residences • Getting to net zero energy use and net zero greenhouse gas emissions through high performance code alternatives • Electronic code permitting and compliance alternatives

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration of Biological, Physical/Chemical and Energy Efficient Systems in the CELSS Antarctic Analog: Performance of Prototype Systems and Issues for Life Support

The Controlled Ecological Life Support System (CELSS) Antarctic Analog Project (CAAP) is a joint endeavor between the National Science Foundation, Office of Polar Programs (NSF-OPP), and the National Aeronautics and Space Administration (NASA). The fundamental objective is to develop, deploy, and operate a testbed of advanced life support technologies at the Amundsen-Scott South Pole Station that enable the objectives of both the NSF and NASA. The functions of food production, water purification, and waste treatment, recycle, and reduction provided by CAAP will improve the quality of life for the South Pole inhabitants, reduce logistics dependence, enhance safety, and minimize environmental impacts associated with human presence on the polar plateau. Because of the analogous technical, scientific, and mission features with Planetary missions, such as a mission to Mars, CAAP provides NASA with a method for validating technologies and overall approaches to supporting humans. Prototype systems for waste treatment, water recycle, resource recovery and crop production are being evaluated in a testbed at Ames Research Center. The combined performance of these biological and physical/chemical systems as an integrated function in support of the human habitat will be discussed. Overall system performance will be emphasized. The effectiveness and efficiency of component technologies will be discussed in the context of energy and mass flow within the system and contribution to achieving a mass and energy conservative system. Critical to the discussion are interfaces with habitat functions outside of the closed-loop life support: the ability of the system to satisfy the life support requirements of the habitat and the ability to define input requirements. The significance of analog functions in relation to future Mars habitats will be discussed.

Bubenheim, David L.↗

Daemen Alternative Energy/Geothermal Technologies Demonstration Program, Erie County

The purpose of the Daemen Alternative Energy/Geothermal Technologies Demonstration Project is to demonstrate the use of geothermal technology as model for energy and environmental efficiency in heating and cooling older, highly inefficient buildings. The former Marian Library building at Daemen College is a 19,000 square foot building located in the center of campus. Through this project, the building was equipped with geothermal technology and results were disseminated. Gold LEED certification for the building was awarded. 1) How the research adds to the understanding of the area investigated. This project is primarily a demonstration project. Information about the installation is available to other companies, organizations, and higher education institutions that may be interested in using geothermal energy for heating and cooling older buildings. 2) The technical effectiveness and economic feasibility of the methods or techniques investigated or demonstrated. According to the modeling and estimates through Stantec, the energy-efficiency cost savings is estimated at 20%, or $24,000 per year. Over 20 years this represents $480,000 in unrestricted revenue available for College operations. See attached technical assistance report. 3) How the project is otherwise of benefit to the public. The Daemen College Geothermal Technologies Ground Source Heat Pumps project sets a standard for retrofitting older, highly inefficient, energy wasting and environmentally irresponsible buildings that are quite typical of many of the buildings on the campuses of regional colleges and universities. As a model, the project serves as an energy-efficient system with significant environmental advantages. Information about the energy-efficiency measures is available to other colleges and universities, organizations and companies, students, and other interested parties. The installation and renovation provided employment for 120 individuals during the award period. Through the new Center, Daemen will continue to host a range of events on campus for the general public. The College does not charge fees for speakers or most other events. This has been a long-standing tradition of the College.

15 GEOTHERMAL ENERGY↗

ARMD Fundamental Aeronautics Program

This slide presentation focuses work of the Aeronautics Research Mission Directorate (ARMD) with particular interest on the work being done to address the environmental and energy efficiency challenges. Particular interest is on the Subsonic Fixed Wing (SFW) project, though there is discussion of the rotorcraft and the supersonics environmental challenges.

Dryer, Jay↗

Chapter 6: Residential Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Given new regulations, increased complexity in the market, and the general shift from CFLs to LEDs, this evaluation protocol was updated in 2017 to shift the focus of the protocols toward LEDs and away from CFLs and to resolve evaluation uncertainties affecting residential lighting incentive programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Home Case Study: Dwell Development, Seattle, Washington

This Challenge Home is one of 42 homes in a micro-community of ultra-modern, energy-efficient homes built by Dwell Development on an urban gray-field site in South Seattle. Every home will achieve a 5-Star Built Green rating from the regional master builders association and meet the criteria of the Northwest ENERGY STAR program, which is more strict than the national ENERGY STAR criteria. Also, the home won a 2013 Housing Innovation Award in the "systems builder" category.

Building America↗

Accomplishments and Mid-Year Performance Report: Wind Energy Program Fiscal Year 2020

Through transformative science and innovation, the U.S. Department of Energy's (DOE's) National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory's (NREL's) Flatirons Campus helps lead the way to a sustainable energy future that powers America with significant levels of reliable, low-cost, and accessible wind energy. Since 1976, NREL has provided an ideal environment for the research and development (R&D) of advanced energy technologies through: Wind energy resource assessments, World-class research facilities, High-performance computing and modeling, Data and technology analysis, Manufacturing breakthroughs, Environmental analysis and wildlife conservation efforts, Education and training programs for a future workforce. These activities enable the innovations needed to advance U.S. wind systems, address market and deployment barriers, and drive down the cost of wind energy with more efficient, more reliable, and more predictable wind energy systems. This report provides an overview of the achievements NREL delivered on behalf of DOE's Wind Energy Technologies Office (WETO) and other partners during the first and second quarters of Fiscal Year (FY) 2020.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

A performant energy-conserving particle reweighting method for Particle-in-Cell simulations

A new particle-based reweighting method is developed and demonstrated in the Aleph Particle-in-Cell with Direct Simulation Monte Carlo (PIC-DSMC) program. Novel splitting and merging algorithms ensure that modified particles maintain physically consistent positions and velocities. This method allows a single reweighting simulation to efficiently model plasma evolution over orders of magnitude variation in density, while accurately preserving energy distribution functions (EDFs). Demonstrations on electrostatic sheath and collisional rate dynamics show that reweighting simulations achieve accuracy comparable to fixed weight simulations with substantial computational time savings. This highly performant reweighting method is recommended for modeling plasma applications that require accurate resolution of EDFs or exhibit significant density variations in time or space.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗