Nonlinear Acoustic Response of an Aircraft Fuselage Sidewall Structure by a Reduced-Order Analysis

A reduced-order nonlinear analysis of a structurally complex aircraft fuselage sidewall panel is undertaken to explore issues associated with application of such analyses to practical structures. Of primary interest is the trade-off between computational efficiency and accuracy. An approach to modal basis selection is offered based upon the modal participation in the linear regime. The nonlinear static response to a uniform pressure loading and nonlinear random response to a uniformly distributed acoustic loading are computed. Comparisons of the static response with a nonlinear static solution in physical degrees-of-freedom demonstrate the efficacy of the approach taken for modal basis selection. Changes in the modal participation as a function of static and random loading levels suggest a means for improvement in the basis selection.

Przekop, Adam↗

Tethered Space Satellite-1 (TSS-1): Wound About a Bolt

In the early 1990's US and Italian scientists collaborated to study the electrodynamics on a long tether between two satellites as it moved through the electrically charged portion of Earth's atmosphere called the ionosphere. Potential uses for the electrical current induced in the long wire include power and thrust generation for a satellite, momentum exchange, artificial gravity, deployment of sensors or antennas, and gravity-gradient stabilization. The Tethered Space Satellite (TSS) was a first-of-its-kind experiment with long tethers in space. It consisted of a satellite with science experiments attached to a 12.5 mile long, very thin (0.10 inch diameter) copper wire assembly wound around a spool in the deployer reel mechanism. The whole mechanism sits on a pallet that is installed into the Shuttle bay. At an altitude of 160 nautical miles above earth, the satellite would be deplodeployed from the Shuttle bay by raising it on a boom facing away from Earth. Once cleared of the bay, the deployer mechanism would slowly feed out the 12-plus miles of tether. Scientific data would be collected throughout the operation, after which the satellite would be reeled back in. A receiver spool to catch the 12.5 mile tether as it was being unwound by the deployer reel mechanism was set up to do the system-level test of deployer real mechanism prior to installing the loaded pallet into the Shuttle bay. The system level tests were required before the pallet could be installed into the Space Shuttle cargo bay. A few months before flight, the system level tests, including unreeling and reeling the tether, were completed at Kennedy Space Center (KSC) and the TSS payload was installed onto the Spacelab pallet. Some of this testing equipment was then shipped back to the contractor, Martin Marietta. Integration with the Shuttle began. Systems-level load analyses, which cannot be run until all information about each payload is finalized, was run in parallel with the physical integration of the hardware into the Shuttle payload bay. An analysis, called Coupled loads analysis, incorporates any updates to the model due to system level tests of all the different payloads, and any changes that were found during integration. Engineering analysis examines the worst case scenarios for the loads the hardware will see. The two times during the mission where the dynamic loads are the worst were 1) the first 10-second portion of Shuttle lift off, and 2) a 2-second time during landing when the landing gears hit the ground. The coupled loads analysis using the final verification loads showed that a single bolt attaching the deployer reel mechanism to the support structure had a "negative margin" - which is an indication that it might fail - during touch down. Hardware certification rules do not allow for hardware to fly with negative margins. A structural failure of one payload could have serious or catastrophic consequences to other payloads, or may significantly damage the Orbiter. The issue had to be resolved before the flight.

O'Connor, Brian↗

Emerging Technologies for Improved Plug Load Management Systems: Learning Behavior Algorithms and Automatic and Dynamic Load Detection

Plug loads are responsible for a significant portion of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them one of the most challenging building end uses to manage. Plug load management systems exist today that utilize smart plugs to meter and control devices at the outlet level, however, their uptake has been relatively slow in part due to the significant labor required for installation and maintenance. Learning behavior algorithms and automatic and dynamic load detection have been identified as two technology areas that could accelerate the adoption of plug load management systems by reducing these labor demands and providing additional energy efficiency and non-energy benefits. Learning behavior algorithms learn occupant behavior and adjust plug load management systems accordingly, allowing for the automatic creation of optimized control schedules. Automatic and dynamic load detection allows a plug load management system to identify devices as they are plugged in to a building and keeps the system up to date as devices are moved throughout a building. In this paper, we present our findings with respect to the current state of these two technologies based on a review of existing research and patents, as well as a series of interviews with companies working in the plug load space. We have found that, as of now, no commercialized solutions exist for these plug load technologies and that more work is needed to bring them to market. In addition, we summarize our findings related to the technology challenges, market barriers, drivers, and opportunities for these technologies moving forward.

30 DIRECT ENERGY CONVERSION↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

X-ray Characterization of Conformational Changes of Human Apo- and Holo-Transferrin

Human serum transferrin (Tf) is a bilobed glycoprotein whose function is to transport iron through receptor-mediated endocytosis. The mechanism for iron release is pH-dependent and involves conformational changes in the protein, thus making it an attractive system for possible biomedical applications. In this contribution, two powerful X-ray techniques, namely Macromolecular X-ray Crystallography (MX) and Small Angle X-ray Scattering (SAXS), were used to study the conformational changes of iron-free (apo) and iron-loaded (holo) transferrin in crystal and solution states, respectively, at three different pH values of physiological relevance. A crystallographic model of glycosylated apo-Tf was obtained at 3.0 Å resolution, which did not resolve further despite many efforts to improve crystal quality. In the solution, apo-Tf remained mostly globular in all the pH conditions tested; however, the co-existence of closed, partially open, and open conformations was observed for holo-Tf, which showed a more elongated and flexible shape overall.

59 BASIC BIOLOGICAL SCIENCES↗

Degradation mechanisms of Platinum Nanoparticle Catalysts in Proton Exchange Membrane Fuel Cells: The Role of Particle Size

Five membrane-electrode assemblies (MEAs) with different average sizes of platinum (Pt) nanoparticles (2.2, 3.5, 5.0, 6.7, and 11.3 nm) in the cathode were analyzed before and after potential cycling (0.6 to 1.0 V, 50 mV/s) by transmission electron microscopy. Cathodes loaded with 2.2 nm and 3.5 nm catalyst nanoparticles exhibit the following changes during electrochemical cycling: (i) substantial broadening of the size distribution relative to the initial size distribution, (ii) presence of coalesced particles within the electrode, and (iii) precipitation of sub-micron-sized particles with complex shapes within the membrane. In contrast, cathodes loaded with 5.0 nm, 6.7 nm and 11.3 nm size catalyst nanoparticles are significantly less prone to the aforementioned effects. As a result, the electrochemically-active surface area (ECA) of MEA cathodes loaded with 2.2 nm and 3.5 nm nanoparticle catalysts degrades dramatically within 1,000 cycles of operation, while the electrochemically-active surface area of MEA cathodes loaded with 5.0 nm, 6.7 nm and 11.3 nm nanoparticle catalysts appears to be stable even after 10,000 cycles. The loss in MEA performance for cathodes loaded with 2.2 nm and 3.5 nm nanoparticle catalysts appears to be due to the loss in electrochemically-active surface area concomitant with the observed morphological changes in these nanoparticle catalysts

DISSOLUTION↗

Thermal Radiator Pointing for International Space Station

In order to provide thermal radiation environments that result in adequate beat rejection, the single-phase, liquid ammonia (NH3) heat rejection system on the International Space Station (ISS) requires that its two thermal radiator wings be dynamically rotated as the ISS travels through its orbit. This paper discusses the closed-loop, thermal radiator pointing system that is used on ISS to ensure adequate heat rejection by the radiators, while preventing freezing of the ammonia under low heat loads and cold-environmental conditions. Although initial designs used an open-loop approach for radiator pointing, concerns about performance robustness, algorithm complexity, memory requirements, and sustaining support drove the development of a more robust, simpler, closed-loop system. Hence, the challenge of the closed-loop system was to utilize existing sensors, actuators and computers to fit into the existing hardware and software architecture of the ISS. Using a proportional-integral (PI) control architecture with limited output and an anti-windup integrator, the temperature of the ammonia coming out of the radiator is measured and controlled by adjusting the radiator wing orientation. The radiator wing orientation for the local minimum environment is fed forward to the control system, and the closed-loop controller is used to generate a bias off of that local minimum environment in order to heat up the ammonia when necessary to avoid freezing. In the earth's shadow, the controller is suspended and the radiator wing is oriented to face the earth, the local maximum thermal environment which further prevents freezing of the ammonia. This control architecture is shown to provide adequate heat rejection and avoid freezing of the ammonia, even though the physical system consists of large transport delays and time-varying dynamics which change dramatically due to orbit motion and variable heat loads.

Green, Scott↗

Dynamic Thermal Performance Analysis of PCM Products Used for Energy Efficiency and Internal Climate Control in Buildings

PCMs are attractive for the future generation of buildings, where energy efficiency targets and thermal comfort expectations are increasingly prioritized. Experimental analysis of local thermal processes in these dynamic components and whole-building energy consumption predictions are essential for the proper implementation of PCMs in buildings. This paper discusses the experimental analysis of the thermophysical characteristics of both a latent heat storage material (PCM) and a product containing this PCM. The prototype product under investigation is a panelized PCM technology containing inorganic, salt-hydrate-based PCM. The thermal analysis includes studies of melting and freezing temperatures, enthalpy changes during phase change processes, nucleation intensity, sub-cooling effects, and PCM stability. The PCM’s stability is also investigated, as is the ability of PCM products to control local temperatures and peak load transmission times. Two inorganic PCM formulations based on calcium chloride hexahydrate (CaCl 2 .6H 2 O) were prepared and tested in laboratory conditions. Material-scale testing results were compared with outcomes from the system-scale analysis, using both laboratory test methods as well as field exposure in test huts. This work demonstrates that PCM technologies used in buildings can effectively control both the magnitude of thermal storage capacity as well as the time of the peak thermal load. It was found that commonly used material-scale testing methods may not always be beneficial in assessing the dynamic thermal performance characteristics of building technologies containing PCMs.

42 ENGINEERING↗

Dynamic response of additively manufactured Ti–5Al–5V–5Mo–3Cr as a function of heat treatment

Both shock and shockless compression experiments were performed on laser powder bed fusion (LPBF) Ti–5Al–5V–5Mo–3Cr (Ti-5553) to peak compressive stresses near 15 GPa. Experiments were performed on the as-built material, containing a purely β (body centered cubic) microstructure, and two differing heat treatments resulting in a dual phase α (hexagonal close packed) and β microstructure. The Hugoniot, Hugoniot elastic limit (HEL), and spallation strength were measured and compared to wrought Ti-6Al-4V (Ti-64). The results indicate the LPBF Ti-5553 Hugoniot response is similar between heat treatments and to Ti-64. The HEL stress observed in the LPBF Ti-5553 was considerably higher than Ti-64, with the as-built, fully β alloy exhibiting the largest values. The spallation strength of the LPBF Ti-5553 was also similar to Ti-64. Clear evidence of initial porosity serving as initiation sites for spallation damage was observed when comparing computed tomography measurements before and after loading. Post-mortem scanning electron microscopy images of the recovered spallation samples showed no evidence of retained phase changes near the spall plane. The spall plane was found to have kinks aligned with the loading direction near areas with large concentrations of twin-like, crystallographic defects in the as-built condition. For the heat-treated samples, the concentrations of twin-like, crystallographic defects were absent, and no preference for failure at the interface between the α and β phases was observed.

36 MATERIALS SCIENCE↗

Paclitaxel loading in cationic liposome vectors is enhanced by replacement of oleoyl with linoleoyl tails with distinct lipid shapes

Abstract Lipid carriers of hydrophobic paclitaxel (PTX) are used in clinical trials for cancer chemotherapy. Improving their loading capacity requires enhanced PTX solubilization. We compared the time-dependence of PTX membrane solubility as a function of PTX content in cationic liposomes (CLs) with lipid tails containing one (oleoyl; DOPC/DOTAP) or two (linoleoyl; DLinPC/newly synthesized DLinTAP) cis double bonds by using microscopy to generate kinetic phase diagrams. The DLin lipids displayed significantly increased PTX membrane solubility over DO lipids. Remarkably, 8 mol% PTX in DLinTAP/DLinPC CLs remained soluble for approximately as long as 3 mol% PTX (the solubility limit, which has been the focus of most previous studies and clinical trials) in DOTAP/DOPC CLs. The increase in solubility is likely caused by enhanced molecular affinity between lipid tails and PTX, rather than by the transition in membrane structure from bilayers to inverse cylindrical micelles observed with small-angle X-ray scattering. Importantly, the efficacy of PTX-loaded CLs against prostate cancer cells (their IC50 of PTX cytotoxicity) was unaffected by changing the lipid tails, and toxicity of the CL carrier was negligible. Moreover, efficacy was approximately doubled against melanoma cells for PTX-loaded DLinTAP/DLinPC over DOTAP/DOPC CLs. Our findings demonstrate the potential of chemical modifications of the lipid tails to increase the PTX membrane loading while maintaining (and in some cases even increasing) the efficacy of CLs. The increased PTX solubility will aid the development of liposomal PTX carriers that require significantly less lipid to deliver a given amount of PTX, reducing side effects and costs.

36 MATERIALS SCIENCE↗

VO2 kinetics of constant-load exercise following bed-rest-induced deconditioning

Previous studies have shown that the oxygen uptake kinetics during exercise and recovery may be changed by alterations in work intensity, prior exercise, muscle group involvement, ambient conditions, posture, disease state, and level of physical conditioning. However, the effects of detraining on oxygen uptake kinetics have not been determined. The present investigation has the objective to determine the effects of deconditioning following seven days of continuous head-down bed rest on changes in steady-state oxygen uptake, O2 deficit, and recovery oxygen uptake during the performance of constant-load exercise. The obtained results may provide support for previous proposals that submaximal oxygen uptake was significantly reduced following bed rest. The major finding was that bed-rest deconditioning resulted in a reduction of total O2 transport/utilization capacity during the transient phase of upright but not supine exercise.

Convertino, V. A.↗

The effect of Tricresyl-Phosphate (TCP) as an additive on wear of Iron (Fe)

The effect of tricresyl phosphate (TCP) as an antiwear additive in lubricant trimethyol propane triheptanoate (TMPTH) was investigated. The objective was to examine step loading wear by use of surface analysis, wetting, and chemical bonding changes in the lubricant. The investigation consisted of steploading wear studies by a pin or disk tribometer, the effects on wear related to wetting by contact angle and surface tension measurements of various liquid systems, the chemical bonding changes between lubricant and TCP chromatographic analysis, and by determining the reaction between the TCP and metal surfaces through wear scar analysis by Auger emission spectroscopy (AES). The steploading curve for the base fluid alone shows rapid increase of wear rate with load. The steploading curve for the base fluid in presence of 4.25 percent by volume TCP under dry air purge has shown a great reduction of wear rate with all loads studied. It has also been found that the addition of 4.25 percent by volume TCP plus 0.33 percent by volume water to the base lubricant under N2 purge also greatly reduces the wear rate with all loads studied. AES surface analysis reveals a phosphate type wear resistant film, which greatly increases load-bearing capacity, formed on the iron disk. Preliminary chromatographic studies suggest that this film forms either because of ester oxidation or TCP degradation. Wetting studies show direct correlation between the spreading coefficient and the wear rate.

Ghose, Hiren M.↗

Condition Monitoring of Wind Turbine Planetary Gearboxes Under Different Operating Conditions

Digitally enhanced services for wind power could reduce Operations and Maintenance (O&M) costs as well as the Levelised Cost Of Energy (LCOE). Therefore, there is a continuous need for advanced monitoring techniques which can exploit the opportunities of Internet of Things (IoT) and Big Data Analytics, revolutionizing the future of the energy sector. The heart of wind turbines is a rather complex epicyclic gearbox. Among others, extremely critical gearbox components which are often responsible for machinery stops are the rolling element bearings. The vibration signatures of bearings are rather weak compared to other components, such as gears, and as a result an extended number of signal processing techniques and tools have been proposed during the last decades, focusing towards accurate, early, and on time bearing fault detection with limited false alarms and missed detections. Envelope Analysis is one of the most important methodologies, where an envelope of the vibration signal is estimated usually after filtering around a frequency band excited by impacts due to the bearing faults. Different tools, such as Kurtogram, have been proposed in order to accurately select the optimum filter parameters (center frequency and bandwidth). Cyclic Spectral Correlation and Cyclic Spectral Coherence, based on Cyclostationary Analysis, have been proved as very powerful tools for condition monitoring. The monitoring techniques seem to have reached a mature level in case a machinery operates under steady speed and load. On the other hand, in case the operating conditions change, it is still unclear whether the change of the monitoring indicators is due to the change of the health of the machinery or due to the change of the operating parameters. Recently, the authors have proposed a new tool called IESFOgram, which is based on Cyclic Spectral Coherence and can automatically select the filtering band. Furthermore, the Cyclic Spectral Coherence is integrated along the selected frequency band leading to an Improved Envelope Spectrum. In this paper, the performance of the tool is evaluated and further extended on cases operating under different speeds and different loads. The effectiveness of the methodology is tested and validated on the National Renewable Energy Laboratory (NREL) wind turbine gearbox vibration condition monitoring benchmarking data set which includes various faults with different levels of diagnostic complexity as well as various speed and load operating conditions.

17 WIND ENERGY↗

The human brainome: network analysis identifies HSPA2 as a novel Alzheimer’s disease target

Our hypothesis is that changes in gene and protein expression are crucial to the development of late onset Alzheimer’s disease (LOAD). Previously we examined how DNA alleles control downstream expression of RNA transcripts and how those relationships are changed in late onset Alzheimer’s diseaseLOAD. We have now examined how proteins are incorporated into networks in two separate series and evaluated our outputs in two different cell lines. Our pipeline included the following steps: 1. Predicting expression quantitative trait loci (eQTLs), 2. Determining differential expression, 3. Analyzing networks of transcript and peptide relationships and 4. Validating effects in two separate cell lines. We performed all our analysis in two separate brain series to validate effects. Our two series included 345 samples in the first set (177 controls, 168 cases; age range 65-105; 58% female; KRONOSII cohort) and 409 samples in the replicate set (153 controls, 141 cases, 115 mild cognitive impairmentMCI; age range 66-107; 63% female; RUSH cohort). Our top target is Heat Shock Protein Family A Member 2 (HSPA2), which was identified as a key driver in our two datasets. HSPA2 was validated in two cell lines, with overexpression driving further elevation of Abeta40 and Abeta42 levels in amyloid precursor protein APP mutant cells as well as significant elevation of microtubule associated protein Tau and phospho- Tau in a modified neuroglioma line. This work further demonstrates that studying changes in gene and protein expression is crucial to understanding late onset disease and further nominates HSPA2 as a specific key regulator of late onset Alzheimer’s diseaseLOAD processes.

Petyuk, Vladislav A.↗

Modeled Impacts of LULC and Climate Change Predictions on Water Quality in Belize

Land use and land cover (LULC) change can have detrimental effects on water quality. In Belize, agricultural expansion creates the risk of increased sediment load and excess nutrients in runoff water, while deforestation removes potential infiltration sites for this outflow. Climate change and evolving precipitation rates can intensify the quantity of runoff, further enabling the flow of sediments and excess nutrients out to the lagoon surrounding the Belize Barrier Reef Reserve System (BBRRS). This study estimated future water quality in Belize by projecting LULC change through 2090 across Belize’s major watersheds based on observed trends from 2008-2018. Those LULC projections were subsequently combined with soil type data, elevation, and precipitation rates into a hydrologic model to produce runoff estimates as a proxy for water quality. The two Coupled Model Intercomparison Project phase 6 (CMIP-6) scenarios employed in the study represented bookend climate change scenarios, and both predicted lower precipitation rates in Belize over the next century due to climate change. When holding LULC change constant, these climate scenarios projected a decrease in runoff, suggesting a positive relationship between precipitation and runoff. The southern watersheds in particular are projected to experience greater decreases in annual rainfall and runoff by 2090. When holding climate constant, runoff increased by approximately 2.8% in the Conservation-focused LULC scenario by 2090, which was 28% lower than the Business as Usual scenario and 42% lower than the Development scenario.

water resources↗

Custom Controls for Improved Demand Response from Heat Pump Water Heaters

As part of a Grid Modernization Laboratory Consortium (GMLC) project looking at defining grid services for a range of devices, NREL used a custom controller to investigate the ability of a HPWH to provide load add and load shed in hybrid and electric resistance mode using standard set point control. Based on those results, changes were made to the controls to increase the amount of grid services delivered, especially in the load-add case, and speed up the recovery from those events. The custom controls also include less common methods, such as duty cycling of the heat pump or elements. The improved controls led to an increase the amount of demand response that could be provided and enabled faster recovery. Results from the laboratory experiments will be presented, along with details about the custom controls that were implemented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of slots on the buckling and postbuckling behavior of laminated plates

An experimental study was conducted to evaluate the effect of lateral slots on the buckling response, the postbuckling response, and the failure characteristics of flat rectangular graphite-epoxy plates loaded in compression. The slots did not significantly affect the prebuckling and buckling behavior of the plates. The slots caused local changes in the strain distribution and out-of-plane deformations near the slot. Failure loads and modes were strongly affected by slot location. Centrally located slots did not affect the failure loads or failure modes of the plates. Slots located close to an unloaded edge of a plate reduced the postbuckling strength of the plate and affected the failure mode. For one slightly offset slot location, interaction of out-of-plane deformations with the slot tip was observed to affect the failure mode significantly without affecting the failure load.

Gurdal, Z.↗

Altered susceptibility to motion sickness as a function of subgravity level

Large interindividual differences among 74 normal subjects in the change in susceptibility to motion sickness with effective lifting of the normal g-load by parabolic flight maneuvers were recorded with high test-retest reliability. Most subjects, who were required to make standardized head movements while seated in a chair rotating at a constant speed, demonstrated either a substantial increase or a decrease in susceptibility, in confirmation of a previous study, while a few appeared to be more or less unaffected by the 1 g to 0 g gravitational change. A similar test procedure conducted with eighteen of the subjects at lunar- and Martian-gravity levels revealed further interindividual differences in susceptiblity as a function of g-level. The subjects with gravity-dependent susceptibility revealed: (1) a progressive change in susceptibility as a function of g-load in either the positive or negative direction that was characteristic of the individual, (2) a susceptibility level that appeared to be maintained at the fractional g-load, and (3) immunity to motion sickness at all g-levels tested below the earth standard. The case history as well as ground-based functional and provocative tests of normal subjects proved to be inadequate in predicting susceptibility to motion sickness under subgravity conditions.

Miller, E. F., II↗