Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

An Orbital Trap Mass Analyzer Using a Hybrid Magnetic-Electric Field: A Simulation Study

An orbital ion trap mass analyzer employing hybrid magnetic-electric field was designed and simulated. The trap has a rotational symmetrical structure and the hybrid trapping field was created in a toroidal space between 12 pairs of sector detection electrodes. Ion injection and ion orbital motion inside the trap were simulated using SIMION 8.1 with a user Lua program, and the required electric and magnetic field were investigated. The image charge signal can be picked up by the 12 pairs of detection electrodes and the mass resolution was evaluated using FFT. The simulated resolving power for the optimized configuration over 79,000 FWHM was obtained at the magnetic induction intensity of 0.5 Tesla in the simulation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Program Simulates Spacecraft Communication Scenarios

Dynamic Environment Communications Alalysis Testbed (DECAT) computer program is modular simulation program. Computes effects of motion, antenna radiation patterns, noise, interference, and other phenomena. Flexibility enables users to analyze many communications scenarios quickly and easily, eliminating need for users to create specific computer programs. Users create simulations involving any number of vehicles, receivers, transmitters, and antennas via graphical user interface (GUI). DECAT GUI implemented by use of software tool called "Transportable Applications Environment Plus" (TAE Plus). Written in C language. Graphical user interface requires TAE Plus, Version 5.1 package available from COSMIC (GSC-13463).

Land, Kenneth P.↗

TESTING STRICT HYDROSTATIC EQUILIBRIUM IN SIMULATED CLUSTERS OF GALAXIES: IMPLICATIONS FOR A1689

Accurate mass determination of clusters of galaxies is crucial if they are to be used as cosmological probes. However, there are some discrepancies between cluster masses determined based on gravitational lensing and X-ray observations assuming strict hydrostatic equilibrium (i.e., the equilibrium gas pressure is provided entirely by thermal pressure). Cosmological simulations suggest that turbulent gas motions remaining from hierarchical structure formation may provide a significant contribution to the equilibrium pressure in clusters. We analyze a sample of massive clusters of galaxies drawn from high-resolution cosmological simulations and find a significant contribution (20%-45%) from non-thermal pressure near the center of relaxed clusters, and, in accord with previous studies, a minimum contribution at about 0.1 R {sub vir}, growing to about 30%-45% at the virial radius, R {sub vir}. Our results strongly suggest that relaxed clusters should have significant non-thermal support in their core region. As an example, we test the validity of strict hydrostatic equilibrium in the well-studied massive galaxy cluster A1689 using the latest high-resolution gravitational lensing and X-ray observations. We find a contribution of about 40% from non-thermal pressure within the core region of A1689, suggesting an alternate explanation for the mass discrepancy: the strict hydrostatic equilibrium is not valid in this region.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical Simulation of Flow Field Within Parallel Plate Plastometer

Parallel Plate Plastometer (PPP) is a device commonly used for measuring the viscosity of high polymers at low rates of shear in the range 10 4 to 10 9 poises. This device is being validated for use in measuring the viscosity of liquid glasses at high temperatures having similar ranges for the viscosity values. PPP instrument consists of two similar parallel plates, both in the range of 1 inch in diameter with the upper plate being movable while the lower one is kept stationary. Load is applied to the upper plate by means of a beam connected to shaft attached to the upper plate. The viscosity of the fluid is deduced from measuring the variation of the plate separation, h, as a function of time when a specified fixed load is applied on the beam. Operating plate speeds measured with the PPP is usually in the range of 10 -3 cm/s or lower. The flow field within the PPP can be simulated using the equations of motion of fluid flow for this configuration. With flow speeds in the range quoted above the flow field between the two plates is certainly incompressible and laminar. Such flows can be easily simulated using numerical modeling with computational fluid dynamics (CFD) codes. We present below the mathematical model used to simulate this flow field and also the solutions obtained for the flow using a commercially available finite element CFD code.

Basil N. Antar↗

SU-F-T-673: Effects of Cardiac Induced Brain Pulsations On Proton Minibeams

Purpose: To quantify the dosimetric impact of internal motion within the brain on spatially modulated proton minibeam radiation therapy (pMRT) for small animal research. Methods: The peak-to-valley dose ratio (PVDR) is an essential dosimetric factor for pMRT. Motion of an animal brain caused by cardiac-induced pulsations (CIP) can impact dose deposition. For synchrotron generated high dose rate X-ray microbeams this effect is evaded due to the quasi-instantaneous delivery. By comparison, pMRT potentially suffers increased spread due to lower dose rates. However, for a given dose rate it is less susceptible to beam spread than microbeams, due to the spatial modulation being an order of magnitude larger. Monte Carlo simulations in TOPAS were used to model the beam spread for a 50.5MeV pMRT beam. Motion effects were simulated for a 50mm thick brass collimator with 0.3mm slit width and 1.0mm center-to-center spacing in a water phantom. The maximum motion in a rat brain due to CIP has been reported to be 0.06mm. Motion was simulated with a peak amplitude in the range 0–0.2mm. Results: The impact of 0.06mm peak motion was minimal and reduced the PVDR by about 1% at a depth of 10mm. For 0.2mm peak motion the PVDR was reduced by 16% at a depth of 10mm. Conclusion: For the pMRT beam the magnitude of cardiac-induced brain motion has minimal impact on the PVDR for the investigated collimator geometry. For more narrow beams the effect is likely to be larger. This indicates that delivery of pMRT to small animal brains should not be affected considerably by beamlines with linac compatible dose rates.

60 APPLIED LIFE SCIENCES↗

Mars Tumbleweed Simulation Using Singular Perturbation Theory

The Mars Tumbleweed is a new surface rover concept that utilizes Martian winds as the primary source of mobility. Several designs have been proposed for the Mars Tumbleweed, all using aerodynamic drag to generate force for traveling about the surface. The Mars Tumbleweed, in its deployed configuration, must be large and lightweight to provide the ratio of drag force to rolling resistance necessary to initiate motion from the Martian surface. This paper discusses the dynamic simulation details of a candidate Tumbleweed design. The dynamic simulation model must properly evaluate and characterize the motion of the tumbleweed rover to support proper selection of system design parameters. Several factors, such as model flexibility, simulation run times, and model accuracy needed to be considered in modeling assumptions. The simulation was required to address the flexibility of the rover and its interaction with the ground, and properly evaluate its mobility. Proper assumptions needed to be made such that the simulated dynamic motion is accurate and realistic while not overly burdened by long simulation run times. This paper also shows results that provided reasonable correlation between the simulation and a drop/roll test of a tumbleweed prototype.

Raiszadeh, Behzad↗

Vestibular selection criteria development

The experimental elicitation of motion sickness using a short arm centrifuge or a rotating chair surrounded by a striped cylindrical enclosure failed to reveal any systematic group or consistent individual relationship between changes in heart rate, blood pressure, and body temperature and the appearance of symptoms of motion sickness. A study of the influence of vision on susceptability to motion sickness during sudden stop simulation shows that having the eyes open during any part of the sudden stop assessment is more stressful than having them closed throughout the test. Subjects were found to be highly susceptible to motion sickness when tested in free fall and in high force phases of flight. The effect of touch and pressure cues on body orientation during rotation and in parabolic flight are considered as sensory as well as motor adaptation.

Lackner, J. R.↗

Computational studies in low speed rotor aerodynamics

Recently, curved vortex elements have been developed for use in helicopter free wake calculations. As previously documented, these elements allow more efficient and accurate calculation of the wake-on-wake interactions than do traditional straight vortex elements. Curved elements have been applied here to the prediction of the rotor wake geometry and its associated inflow distribution in low speed forward flight. By coupling the wake model to a blade dynamic analysis, a simulation capable of predicting blade motion and hub moments in forward flight has been developed. The resulting code has been validated by successful predictions of the lateral flapping of articulated rotors in low speed level flight, and additional simulators of climb and descent have been undertaken. Successful correlation of other experimental data, including moments due to cyclic on hingeless rotors and transient thrust response in hover, has given encouraging evidence of the capabilities of this code as a tool for analysis of the low speed regime.

Quackenbush, Todd R.↗

Dynamic analysis of an unrestrained, rotating structure through nonlinear simulation

An alternate derivation based on Hamilton's principle of equations of motion of a flexible body for use in nonlinear simulation modeling is presented. The equations include terms representing variation in the inertial properties of the body resulting from flexibility as well as terms coupling rigid body and flexible momenta that arise from satisfaction of only the linear part of the mean axis conditions. An approximate method for including the centrifugal stiffening in a way that permits a variable spin vector is given. The equations are exercised in a simulation program on an example structure initially spinning about its unstable principal axis in a gravity-free vacuum.

Zeiler, Thomas A.↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Statistics of Point Vortex Turbulence in Non-neutral Flows and in Flows with Translational and Rotational Symmetries

A theory (Esler and Ashbee in J Fluid Mech 779:275–308, 2015) describing the statistics of N freely-evolving point vortices in a bounded two-dimensional domain is extended. First, the case of a non-neutral vortex gas is addressed, and it is shown that the density of states function can be identified with the probability density function of an infinite sum of independent non-central chi-squared random variables, the details of which depend only on the shape of the domain. Equations for the equilibrium energy spectrum and other statistical quantities follow, the validity of which are verified against direct numerical simulations of the equations of motion. Second, domains with additional conserved quantities associated with a symmetry (e.g., circle, periodic channel) are investigated, and it is shown that the treatment of the non-neutral case can be modified to account for the additional constraint.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Changes in the dark focus of accommodation associated with simulator sickness

The relationship between the dark focus of accommodation and simulator sickness, a form of motion sickness, was examined in three experiments. In Experiment 1, dark focus was measured in 18 college students in a laboratory setting before and after they viewed a projected motion scene depicting low altitude helicopter flight. In Experiments 2 and 3, dark focus was measured in pilots (N = 16 and 23, respectively) before and after they 'flew' in moving-base helicopter flight simulators with optical infinity CRT visual systems. The results showed that individuals who experienced simulator sickness had either an inward (myopic) change in dark focus (Experiments 1 and 3) or attenuated outward shifts in dark focus (Experiment 2) relative to participants who did not get sick. These results are consonant with the hypothesis that parasympathetic activity, which may be associated with simulator sickness, should result in changes in dark focus that are in a myopic direction. Night vision goggles, virtual environments, extended periods in microgravity, and heads-up displays all produce related visual symptomatology. Changes in dark focus may occur in these conditions, as well, and should be measured.

Fowlkes, Jennifer E.↗

Effects of Relativity Lead to"Warp Speed" Computations

A scientist at Lawrence Berkeley National Laboratory has discovered that a previously unnoticed consequence of Einstein's special theory of relativity can lead to speedup of computer calculations by orders of magnitude when applied to the computer modeling of a certain class of physical systems. This new finding offers the possibility of tackling some problems in a much shorter time and with far more precision than was possible before, as well as studying some configurations in every detail for the first time. The basis of Einstein's theory is the principle of relativity, which states that the laws of physics are the same for all observers, whether the 'observer' is a turtle 'racing' with a rabbit, or a beam of particles moving at near light speed. From the invariance of the laws of physics, one may be tempted to infer that the complexity of a system is independent of the motion of the observer, and consequently, a computer simulation will require the same number of mathematical operations, independently of the reference frame that is used for the calculation. Length contraction and time dilation are well known consequences of the special theory of relativity which lead to very counterintuitive effects. An alien observing human activity through a telescope in a spaceship traveling in the Vicinity of the earth near the speed of light would see everything flattened in the direction of propagation of its spaceship (for him, the earth would have the shape of a pancake), while all motions on earth would appear extremely slow, slowed almost to a standstill. Conversely, a space scientist observing the alien through a telescope based on earth would see a flattened alien almost to a standstill in a flattened spaceship. Meanwhile, an astronaut sitting in a spaceship moving at some lower velocity than the alien spaceship with regard to earth might see both the alien spaceship and the earth flattened in the same proportion and the motion unfolding in each of them at the same speed. Let us now assume that each protagonist (the alien, the space scientist and the astronaut) is to run a computer simulation describing the motion of all of them in a single calculation. In order to model a physical system on a computer, scientists often divide space and time into small chunks. Since the computer must calculated some things for each chunk, having a large system containing numerous small chunks translates to long calculations requiring many computational steps on supercomputers. Let us assume that each protagonist of our intergalactic story uses the space and time slicing as described and chooses to perform the calculation in its own frame of reference. For the alien and the space scientist, the slicing of space and time results in an exceedingly large number of chunks, due to the wide disparity of spatial and time scales needed to describe both their own environment and motion together with the other extremely flattened environment and slowed motion. Since the disparity of scales is reduced for the astronaut, who is traveling at an intermediate velocity, the number of computer operations needed to complete the calculation in his frame of reference will be significantly lower, possibly by many orders of magnitude. Analogously, the new discovery at Lawrence Berkeley National Laboratory shows that there exists a frame of reference minimizing the number of computational operations needed for studying the interaction of beams of particles or light (lasers) interacting at, or near, light speed with other particles or with surrounding structures. Speedups ranging from ten to a million times or more are predicted for the modeling of beams interacting with electron clouds, such as those in the upcoming Large Hadron Collider 'atom smasher' accelerator at CERN (Switzerland), and in free electron lasers and tabletop laser wakefield accelerators. The discovery has surprised many physicists and was received initially with much skepticism. It sounded too much like a 'free lunch'. Yet, the demonstration of a speedup of a stunning one thousand times in a test simulation of a particle beam interacting with a background of electrons (see image), has proven that the effect is real and can be applied successfully, at least to some problems. Work is being actively pursued at Berkeley Lab and elsewhere to validate the feasibility of the method for a wider range of applications, as well as to apply the already successful method to more problems, where it might help getting better understanding of some processes and eventually lead to new findings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle simulation of radio frequency waves with fully-kinetic ions and gyrokinetic electrons

A toroidal particle-in-cell (PIC) code, suitable for investigating nonlinear phenomena in radio frequency (RF) heating and current drive, is developed and verified thereafter through a series of fidelity tests for field solvers and single particle motions in toroidal geometry, where simulation results show good coincidence with analytical prediction. The RF capability is then demonstrated through the integrated benchmarks with linear lower hybrid wave and ion Bernstein wave theory in cylindrical geometry, where the analytic result is easily available. The frequency and mode structure in the simulations agree well with the theoretical prediction.

Lin, Jingbo↗

Catecholaminergic responses to stressful motion stimuli, scopolamine plus amphetamine, and dexamethasone

Peripheral levels of epinephrine (EPI) and neoepinephrine (NE) generally rise following stressful motion stimuli. Effective anti-motion sickness drugs, scopolamine plus, d-amphetamine (S/D) and dexamthasone (DEX) modulate release of EPI and NE. This modulation may be of etiological relevance. Methods: Severe nausea was induced by exposure to coriolis simulation using a rotating chair. Chronic administration of S/D (0.4 and 5 mg/da) DEX (3 mg/day) and placebo preceded coriolis simulation. EPI and NE were measured immediately before and after simulation. A double-blind crossover design was used. Results: Nausea-induced elevations of EPI (2.5 fold, p less than .01) and NE were not diminished upon repeated exposure and adaptation to the stressor. Subjects with more pronounced elevations of EPI following simulation displayed higher resistance to stressful motion (p less .05). Alteration of peripheral catechlomaine levels following drug suggested that motion sickness was not mediated by peripheral catechlolamine receptor simulation. EPI and NE levels were 2.8 and 3.6-fold higher (p less than .03 and .01) after nausea without DEX treatment. DEX loading halved pre-stress levels of EPI and NE (p less than .05). Conclusions: Marked differences were noted in individual responses to drug and systematic responses of EPI and NE. It is possible that the responses of EPI to motion sickness may predict resistance to stressful motion and represent a peripheral manifestation of some as yet unknown central event of etiologic relevance.

Kohl, R. L.↗

UCLA Final Technical Report for the "Community Petascale Project for Accelerator Science and Simulation”.

The UCLA Plasma Simulation Group is a major partner of the “Community Petascale Project for Accelerator Science and Simulation”. This is the final technical report. We include an overall summary, a list of publications, progress for the most recent year, and individual progress reports for each year. We have made tremendous progress during the three years. SciDAC funds have contributed to the development of a large number of skeleton codes that illustrate how to write PIC codes with a hierarchy of parallelism. These codes cover 2D and 3D as well as electrostatic solvers (which are used in beam dynamics codes and quasi-static codes) and electromagnetic solvers (which are used in plasma based accelerator codes). We also used these ideas to develop a GPU enabled version of OSIRIS. SciDAC funds were also contributed to the development of strategies to eliminate the Numerical Cerenkov Instability (NCI) which is an issue when carrying laser wakefield accelerator (LWFA) simulations in a boosted frame and when quantifying the emittance and energy spread of self-injected electron beams. This work included the development of a new code called UPIC-EMMA which is an FFT based electromagnetic PIC code and to new hybrid algorithms in OSIRIS. A new hybrid (PIC in r-z and gridless in φ) algorithm was implemented into OSIRIS. In this algorithm the fields and current are expanded into azimuthal harmonics and the complex amplitude for each harmonic is calculated separately. The contributions from each harmonic are summed and then used to push the particles. This algorithm permits modeling plasma based acceleration with some 3D effects but with the computational load of an 2D r-z PIC code. We developed a rigorously charge conserving current deposit for this algorithm. Very recently, we made progress in combining the speed up from the quasi-3D algorithm with that from the Lorentz boosted frame. SciDAC funds also contributed to the improvement and speed up of the quasi-static PIC code QuickPIC. We have also used our suite of PIC codes to make scientific discovery. Highlights include supporting FACET experiments which achieved the milestones of showing high beam loading and energy transfer efficiency from a drive electron beam to a witness electron beam and the discovery of a self-loading regime a for high gradient acceleration of a positron beam. Both of these experimental milestones were published in Nature together with supporting QuickPIC simulation results. Simulation results from QuickPIC were used on the cover of Nature in one case. We are also making progress on using highly resolved QuickPIC simulations to show that ion motion may not lead to catastrophic emittance growth for tightly focused electron bunches loaded into nonlinear wakefields. This could mean that fully self-consistent beam loading scenarios are possible. This work remains in progress. OSIRIS simulations were used to discover how 200 MeV electron rings are formed in LWFA experiments, on how to generate electrons that have a series of bunches on nanometer scale, and how to transport electron beams from (into) plasma sections into (from) conventional beam optic sections.

43 PARTICLE ACCELERATORS↗

Investigation of the equatorial orographic-dynamic mechanism applying the bounded derivative method

A system of equations which describe the motion of a barotropic fluid in the presence of bottom topography are presented. The mathematical expression for orography is developed and the bounded derivative initialization method is applied to suppress gravitational oscillations. A stationary orographic trough is simulated. The geopotential and zonal motion have maximum deviation from the mean state at the top of the mountain. Regarding meridional speed, outflow occurs on the windward slope and inflow on the leeward slope. Divergence of order (10(-6)s(-1) is found on the windward slope while convergence of the same order of magnitude resides on the leeward slope. This outcome may have interesting implications regarding real climatology occurring over the equatorial regions of continental land masses.

Semazzi, F. H. M.↗