Indium doped Cd1-xZnxO alloys as wide window transparent conductors

We have synthesized Indium doped Cd 1-x Zn x O alloys across the full composition range using magnetron sputtering method. The crystallographic structure of these alloys changes from rocksalt (RS) to wurtzite (WZ) when the Zn content is higher than 30%. The rocksalt phase alloys in the composition range 0 < x < 0.3 can be efficiently n-type doped, shifting the absorption edge to 3.25 eV and reducing resistivity to about 2.0 × 10 -4 Ω-cm. Here, we found that In doped CdO (ICO) transmits more solar photons than commercial fluorine doped tin oxide (FTO) with comparable sheet conductivity. The infrared transmittance is further extended to longer than 1500 nm wavelengths by depositing the In doped Cd 1-x Zn x O in ~ 1% of O 2 . This material has a potential for applications as a transparent conductor for silicon and multi-junction solar cells.

36 MATERIALS SCIENCE↗

Violation of the Cauchy–Born rule in multi-principal element alloys

Multi-principal element alloys are a novel class of materials that are formed by combining multiple elements in high concentrations and show exceptional properties compared to conventional alloys. These alloys have high configurational entropy due to inherent atomic disorder. The Cauchy–Born rule is a popular homogenization method for linking atomistic to continuum length scales. In this Letter, we use ab initio density functional theory calculations to report that the Cauchy–Born rule, which holds in conventional alloys in the absence of defects, is not valid in multi-principal element alloys. Further, the violation of the Cauchy–Born rule in these alloys is attributed to the presence of atomic disorder due to which the deformations are inhomogeneous. Our results also show the deviations in deformation are related to the magnitude of the stretch and shear by power laws.

36 MATERIALS SCIENCE↗

Characterization of Used Nuclear Fuel with Multivariate Analysis for Process Monitoring

The Multi-Isotope Process (MIP) Monitor combines gamma spectroscopy and multivariate analysis to detect anomalies in various process streams in a nuclear fuel reprocessing system. Measured spectra are compared to models of nominal behavior at each measurement location to detect unexpected changes in system behavior. In order to improve the accuracy and specificity of process monitoring, fuel characterization may be used to more accurately train subsequent models in a full analysis scheme. This paper presents initial development of a reactor-type classifier that is used to select a reactor-specific partial least squares model to predict fuel burnup. Nuclide activities for prototypic used fuel samples were generated in ORIGEN-ARP and used to investigate techniques to characterize used nuclear fuel in terms of reactor type (pressurized or boiling water reactor) and burnup. A variety of reactor type classification algorithms, including k-nearest neighbors, linear and quadratic discriminant analyses, and support vector machines, were evaluated to differentiate used fuel from pressurized and boiling water reactors. Then, reactor type-specific partial least squares models were developed to predict the burnup of the fuel. Using these reactor type-specific models instead of a model trained for all light water reactors improved the accuracy of burnup predictions. The developed classification and prediction models were combined and applied to a large dataset that included eight fuel assembly designs, two of which were not used in training the models, and spanned the range of the initial 235U enrichment, cooling time, and burnup values expected of future commercial used fuel for reprocessing. Error rates were consistent across the range of considered enrichment, cooling time, and burnup values. Average absolute relative errors in burnup predictions for validation data both within and outside the training space were 0.0574% and 0.0597%, respectively. The errors seen in this work are artificially low, because the models were trained, optimized, and tested on simulated, noise-free data. However, these results indicate that the developed models may generalize well to new data and that the proposed approach constitutes a viable first step in developing a fuel characterization algorithm based on gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FOSTERING MULTI-LATERAL COOPERATION BETWEEN THE GOVERNMENTS OF MEXICO, COLOMBIA, AND THE UNITED STATES TO ENHANCE THE PROTECTION OF HIGH-ACTIVITY RADIOACTIVE SOURCES

The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide from sabotage, theft or diversion. The GTRI program has worked successfully with foreign countries to remove and protect nuclear and radioactive materials including high-activity sources used in medical, commercial, and research applications. There are many barriers to successful bilateral cooperation that must be overcome including language, preconceived perceptions, long distances, and different views on the threat and protection requirements. Successful cooperation is often based on relationships and building trusting relationships takes time. In the case of Mexico, GTRI first made contact in 2005. The project then lost momentum and stalled. At the same time, GTRI’s cooperation with the Republic of Colombia was a resounding success resulting in the securing of forty sites; the consolidation of numerous disused/orphan sources at a secure national storage facility; and, the development of a comprehensive approach to security including, inter alia, training and sustainability. The government of Colombia also showcased this comprehensive approach to thirteen Central American and Caribbean countries at a GTRI regional security conference held in Panama in October 2004. Representatives from the Colombian government were aware of GTRI’s interest in initiating cooperation with the Government of Mexico and to facilitate this cooperation, they offered to invite their Mexican counterparts to Colombia to observe its successful cooperation with GTRI. Shortly after that visit, the Government of Mexico agreed to move forward and requested that the cooperative efforts in Mexico be performed in a tripartite manner, leveraging the skills, experience, and resources of the Colombians. As a result, 22 of Mexico’s largest radioactive sites have had security upgrades in place within 18 months of cooperation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unveiling the Hidden Evolution of Crystal Defects and Disorder in Energy Materials

Control of point defects and disorder in functional thin films and 2D materials is critical to realizing their full potential in applications ranging from energy storage to advanced electronics. However, these phenomena are often poorly understood, difficult to characterize, and challenging to direct with precision. This presentation explores emerging multi-modal computer vision to decipher and predict order in materials across multiple length scales in the electron microscope, from the atomic to the nanoscale. By fusing data from diverse sources, these powerful models provide unprecedented insights into materials' lifecycles, enabling the control of defects and their associated properties at a fundamental level. This capability promises to transform materials design and accelerate the development of next-generation technologies.

97 MATHEMATICS AND COMPUTING↗

Robotically Assembled Aerospace Structures: Digital Material Assembly using a Gantry-Type Assembler

This paper evaluates the development of automated assembly techniques for discrete lattice structures using a multi-axis gantry type CNC machine. These lattices are made of discrete components called digital materials. We present the development of a specialized end effector that works in conjunction with the CNC machine to assemble these lattices. With this configuration we are able to place voxels at a rate of 1.5 per minute. The scalability of digital material structures due to the incremental modular assembly is one of its key traits and an important metric of interest. We investigate the build times of a 5x5 beam structure on the scale of 1 meter (325 parts), 10 meters (3,250 parts), and 30 meters (9,750 parts). Utilizing the current configuration with a single end effector, performing serial assembly with a globally fixed feed station at the edge of the build volume, the build time increases according to a scaling law of n4, where n is the build scale. Build times can be reduced significantly by integrating feed systems into the gantry itself, resulting in a scaling law of n3. A completely serial assembly process will encounter time limitations as build scale increases. Automated assembly for digital materials can assemble high performance structures from discrete parts, and techniques such as built in feed systems, parallelization, and optimization of the fastening process will yield much higher throughput.

Mechanical Structure↗

Robotically Assembled Aerospace Structures: Digital Material Assembly using a Gantry-Type Assembler

This paper evaluates the development of automated assembly techniques for discrete lattice structures using a multi-axis gantry type CNC machine. These lattices are made of discrete components called "digital materials." We present the development of a specialized end effector that works in conjunction with the CNC machine to assemble these lattices. With this configuration we are able to place voxels at a rate of 1.5 per minute. The scalability of digital material structures due to the incremental modular assembly is one of its key traits and an important metric of interest. We investigate the build times of a 5x5 beam structure on the scale of 1 meter (325 parts), 10 meters (3,250 parts), and 30 meters (9,750 parts). Utilizing the current configuration with a single end effector, performing serial assembly with a globally fixed feed station at the edge of the build volume, the build time increases according to a scaling law of n4, where n is the build scale. Build times can be reduced significantly by integrating feed systems into the gantry itself, resulting in a scaling law of n3. A completely serial assembly process will encounter time limitations as build scale increases. Automated assembly for digital materials can assemble high performance structures from discrete parts, and techniques such as built in feed systems, parallelization, and optimization of the fastening process will yield much higher throughput.

Manufacturing↗

Efficient multi-keV X-ray sources from laser-exploded metallic thin foils

A set of materials--titanium, copper, and germanium--has been experimented with at the OMEGA laser facility [Boehly, Opt. Commun. 133, 495 (1997)] by irradiating thin foils with a prepulse prior to a main pulse with variable delay, in order to design efficient x-ray laser-sources for backlighting, material testing, and code validation. This concept led to increasing factors from 2 to 4 comparing to cases without prepulse, in the experimental conditions. As a result, high multi-keV x-ray conversion rates have been obtained: 9% for titanium around 4 keV, 1% for copper around 8 keV, and 2.5 to 3% for germanium around 10 keV, which places these pre-exploded metallic targets close to the gas with respect to their performance, with wider energy range. A good agreement with hydroradiative code FCI2[Schurtz, Phys. Plasmas 7, 4238 (2000)] calculations is found for titanium and copper on all diagnostics, with nonlocal-thermal-equilibrium atomic physics and, either nonlocal thermal conduction taking self-generated B-fields into account, or limited thermal conduction with intensity-dependent factor f. The results for germanium indicate that dielectronic processes could play a more significant role when higher irradiation intensity on higher Z material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combinatorial Discovery of Lanthanum–Tantalum Oxynitride Solar Light Absorbers with Dilute Nitrogen for Solar Fuel Applications

© 2017 American Chemical Society. Oxynitrides with the photoelectrochemical stability of oxides and desirable band energetics of nitrides comprise a promising class of materials for solar photochemistry. Challenges in synthesizing a wide variety of oxynitride materials has limited exploration of this class of functional materials, which we address using a reactive cosputtering combined with rapid thermal processing method to synthesize multi-cation-multi-anion libraries. We demonstrate the synthesis of a LaxTa1-xOyNzthin film composition spread library and its characterization by both traditional thin film materials characterization and custom combinatorial optical spectroscopy and X-ray absorption near edge spectroscopy (XANES) techniques, ultimately establishing structure-chemistry-property relationships. We observe that over a substantial La-Ta composition range the thin films crystallize in the same perovskite LaTaON2structure with significant variation of anion chemistry. The relative invariance in optical band gap demonstrates a remarkable decoupling of composition and band energetics so that the composition can be optimized while retaining the desirable 2 eV band gap energy. We also demonstrate the intercalation of diatomic nitrogen into the La3TaO7structure, which gives rise to a direct-allowed optical transition at 2.2 eV, less than half the value of the oxide's band gap. These findings motivate further exploration of the visible light response of this material that is predicted to be stable over a wide range of electrochemical potential.

Suram, Santosh K.↗

A stochastic solver based on the residence time algorithm for crystal plasticity models

Abstract The deformation of crystalline materials by dislocation motion takes place in discrete amounts determined by the Burgers vector. Dislocations may move individually or in bundles, potentially giving rise to intermittent slip. This confers plastic deformation with a certain degree of variability that can be interpreted as being caused by stochastic fluctuations in dislocation behavior. However, crystal plasticity (CP) models are almost always formulated in a continuum sense, assuming that fluctuations average out over large material volumes and/or cancel out due to multi-slip contributions. Nevertheless, plastic fluctuations are known to be important in confined volumes at or below the micron scale, at high temperatures, and under low strain rate/stress deformation conditions. Here, we develop a stochastic solver for CP models based on the residence-time algorithm that naturally captures plastic fluctuations by sampling among the set of active slip systems in the crystal. The method solves the evolution equations of explicit CP formulations, which are recast as stochastic ordinary differential equations and integrated discretely in time. The stochastic CP model is numerically stable by design and naturally breaks the symmetry of plastic slip by sampling among the active plastic shear rates with the correct probability. This can lead to phenomena such as intermittent slip or plastic localization without adding external symmetry-breaking operations to the model. The method is applied to body-centered cubic tungsten single crystals under a variety of temperatures, loading orientations, and imposed strain rates.

42 ENGINEERING↗

Characterization of Highly Nonlinear and Anisotropic Vascular Tissues from Experimental Inflation Data: a Validation Study Towards the Use of Clinical Data for In-vivo Modeling and Analysis

A new ¯nite element (FE) modeling approach is proposed to model blood vessel by using data from blood vessel during in°ation instead of using data from biaxial test to estimate the tissue property. A particular constitutive equation is used to model the tissue property as a dispersed transverse isotropic hyperelastic material under both single-layer and multi-layer assumption for comparison. In order to compensate the drawback of using this type of data that does not provide su±cient information to estimate the tissue property in axial direction, the axial/circumferential elastic moduli ratio is being constrained in a typical range. The semi-global inverse method is applied with the pressure-diameter test data from porcine thoracic aorta to esti- mate the optimal tissue property. The simulated data of all cases is then compared with the biaxial test data. It is found that the single-layer model without the con- straint ¯ts well with the pressure-diameter test data but not with the biaxial test data at the axial direction, so it is suitable only for pressure-diameter analysis. The multi-layer model with the constraint ¯ts well with the pressure-diameter data and also the biaxial test data, so it is suitable to estimate the tissue property and for stress-strain analysis. The constitutive equation and the semi-global inverse method are found e±cient in this study. We believe that this new approach that uses this type of data, such as magnetic resonance imaging (MRI) data that could be ob- tained non-invasive in vivo, is time-e±cient and would be bene¯cial for pre-surgical analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Microstructural stability and mechanical behavior of FeNiMnCr high entropy alloy under ion irradiation

In recent years, high entropy alloys (HEAs) have attracted significant attention due to their excellent mechanical properties and good corrosion resistance, making them potential candidates for high temperature fission and fusion structural applications. However there is very little known about their radiation resistance, particularly at elevated temperatures relevant for energy applications. In the present study, a single phase (face centered cubic) concentrated solid solution alloy of composition 27%Fe-28%Ni-27%Mn-18%Cr was irradiated with 3 or 5.8 MeV Ni ions at temperatures ranging from room temperature to 700 °C and midrange doses from 0.03 to 10 displacements per atom (dpa). Transmission electron microscopy (TEM), scanning transmission electron microscopy with energy dispersive x-ray spectrometry (STEM/EDS) and X-ray diffraction (XRD) were used to characterize the radiation defects and microstructural changes. Irradiation at higher temperatures showed evidence of relatively sluggish solute diffusion with limited solute depletion or enrichment at grain boundaries. The main microstructural feature at all temperatures was high-density small dislocation loops. Voids were not observed at any irradiation condition. Nano-indentation tests on specimens irradiated at room temperature showed a rapid increase in hardness ~35% and ~80% higher than the unirradiated value at 0.03 and 0.3 dpa midrange doses, respectively. The irradiation-induced hardening was less pronounced for 500 °C irradiations (<20% increase after 3 dpa). Overall, the examined HEA material exhibits superior radiation resistance compared to conventional single phase Fe-Cr-Ni austenitic alloys such as stainless steels. Furthermore, the present study provides insight on the fundamental irradiation behavior of a single phase HEA material over a broad range of irradiation temperatures.

36 MATERIALS SCIENCE↗

Clinical Outcome of Patients Treated With 3D Conformal Radiation Therapy (3D-CRT) for Prostate Cancer on RTOG 9406

Purpose: Report of clinical cancer control outcomes on Radiation Therapy Oncology Group (RTOG) 9406, a three-dimensional conformal radiation therapy (3D-CRT) dose escalation trial for localized adenocarcinoma of the prostate. Methods and Materials: RTOG 9406 is a Phase I/II multi-institutional dose escalation study of 3D-CRT for men with localized prostate cancer. Patients were registered on five sequential dose levels: 68.4 Gy, 73.8 Gy, 79.2 Gy, 74 Gy, and 78 Gy with 1.8 Gy/day (levels I-III) or 2.0 Gy/day (levels IV and V). Neoadjuvant hormone therapy (NHT) from 2 to 6 months was allowed. Protocol-specific, American Society for Therapeutic Radiation Oncology (ASTRO), and Phoenix biochemical failure definitions are reported. Results: Thirty-four institutions enrolled 1,084 patients and 1,051 patients are analyzable. Median follow-up for levels I, II, III, IV, and V was 11.7, 10.4, 11.8, 10.4, and 9.2 years, respectively. Thirty-six percent of patients received NHT. The 5-year overall survival was 90%, 87%, 88%, 89%, and 88% for dose levels I-V, respectively. The 5-year clinical disease-free survival (excluding protocol prostate-specific antigen definition) for levels I-V is 84%, 78%, 81%, 82%, and 82%, respectively. By ASTRO definition, the 5-year disease-free survivals were 57%, 59%, 52%, 64% and 75% (low risk); 46%, 52%, 54%, 56%, and 63% (intermediate risk); and 50%, 34%, 46%, 34%, and 61% (high risk) for levels I-V, respectively. By the Phoenix definition, the 5-year disease-free survivals were 68%, 73%, 67%, 84%, and 80% (low risk); 70%, 62%, 70%, 74%, and 69% (intermediate risk); and 42%, 62%, 68%, 54%, and 67% (high risk) for levels I-V, respectively. Conclusion: Dose-escalated 3D-CRT yields favorable outcomes for localized prostate cancer. This multi-institutional experience allows comparison to other experiences with modern radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality of Life in a Prospective, Multicenter Phase 2 Trial of Neoadjuvant Full-Dose Gemcitabine, Oxaliplatin, and Radiation in Patients With Resectable or Borderline Resectable Pancreatic Adenocarcinoma

Purpose: To determine the health-related quality of life (QOL) during and after neoadjuvant chemoradiation therapy and surgery for patients with pancreatic adenocarcinoma. Methods and Materials: Participants of a prospective, phase 2 multi-institutional trial treated with neoadjuvant chemoradiation followed by surgery completed QOL questionnaires (European Organization for Research and Treatment in Cancer Quality of Life Questionnaire version 3.0 [EORTC-QLQ C30], EORTC-Pancreatic Cancer module [EORTC-PAN 26], and Functional Assessment of Cancer Therapy Hepatobiliary and Pancreatic subscale [FACT-Hep]) at baseline, after 2 cycles of neoadjuvant therapy, after surgery, at 6 months from initiation of therapy, and at 6-month intervals for 2 years. Mean scores were compared with baseline. A change >10% was considered a minimal clinically important difference. Results: Of 71 participants in the trial, 55 were eligible for QOL analysis. Compliance ranged from 32% to 74%. The EORTC-QLQ C30 global QOL did not significantly decline after neoadjuvant therapy, whereas the Functional Assessment of Cancer Therapy global health measure showed a statistically, but not clinically significant decline (−8, P=.02). This was in parallel with deterioration in physical functioning (−14.1, P=.001), increase in diarrhea (+16.7, P=.044), and an improvement in pancreatic pain (−13, P=.01) as per EORTC-PAN 26. Because of poor patient compliance in the nonsurgical group, long-term analysis was performed only from surgically resected participants (n=36). Among those, global QOL returned to baseline levels after 6 months, remaining near baseline through the 24-month visit. Conclusions: The study regimen consisting of 2 cycles of neoadjuvant therapy was completed without a clinically significant QOL deterioration. A transient increase in gastrointestinal symptoms and a decrease in physical functioning were seen after neoadjuvant chemoradiation. In those patients who underwent surgical resection, most domains returned back to baseline levels by 6 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Quality T2-Weighted 4-Dimensional Magnetic Resonance Imaging for Radiation Therapy Applications

Purpose: The purpose of this study was to improve triggering efficiency of the prospective respiratory amplitude-triggered 4-dimensional magnetic resonance imaging (4DMRI) method and to develop a 4DMRI imaging protocol that could offer T2 weighting for better tumor visualization, good spatial coverage and spatial resolution, and respiratory motion sampling within a reasonable amount of time for radiation therapy applications. Methods and Materials: The respiratory state splitting (RSS) and multi-shot acquisition (MSA) methods were analytically compared and validated in a simulation study by using the respiratory signals from 10 healthy human subjects. The RSS method was more effective in improving triggering efficiency. It was implemented in prospective respiratory amplitude-triggered 4DMRI. 4DMRI image datasets were acquired from 5 healthy human subjects. Liver motion was estimated using the acquired 4DMRI image datasets. Results: The simulation study showed the RSS method was more effective for improving triggering efficiency than the MSA method. The average reductions in 4DMRI acquisition times were 36% and 10% for the RSS and MSA methods, respectively. The human subject study showed that T2-weighted 4DMRI with 10 respiratory states, 60 slices at a spatial resolution of 1.5 × 1.5 × 3.0 mm{sup 3} could be acquired in 9 to 18 minutes, depending on the individual's breath pattern. Based on the acquired 4DMRI image datasets, the ranges of peak-to-peak liver displacements among 5 human subjects were 9.0 to 12.9 mm, 2.5 to 3.9 mm, and 0.5 to 2.3 mm in superior-inferior, anterior-posterior, and left-right directions, respectively. Conclusions: We demonstrated that with the RSS method, it was feasible to acquire high-quality T2-weighted 4DMRI within a reasonable amount of time for radiation therapy applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical simulations of vertical growth of hydraulic fractures and brine migration in geological formations above the Marcellus shale

One of the critical environmental questions about hydraulic fracturing in shales is the potential for contamination of ground and surface water. There are two specific concerns arising from hydraulic treatments: 1) whether hydraulic fractures extend upward through overlying strata to reach overlying aquifers containing drinking water, and 2) whether injected fluids push native fluids upward into these overlying aquifers. In this work, the extent of likely fracture growth through overlying layers during hydraulic treatment of the Marcellus shale was estimated using a hydraulic fracture model. A wide range of material and fluid flow properties in a multi-layered geologic model was considered. The model was based on conditions and characteristics applicable to the Marcellus shale in that part of the Appalachian basin within southwestern Pennsylvania. Predictions of vertical termination frequencies for hydraulic fractures were used in a multi-layer model of the strata and natural fractures for studying brine migration through the natural and induced fracture network. NFFLOW, the software for explicitly modeling flow within networks of fractures, was utilized to compute transient flow rates according to the schedule of injected fluid during hydraulic fracturing. To aid our analysis, the modeled sequence of geologic strata was capped with a fictitious unfractured, but moderately-permeable layer, which serves as a monitoring zone. The analysis assumes one well lateral was placed in the middle of the Marcellus shale with hydraulic fractures penetrating layers in the model. The newly-developed geomechanical module within NFFLOW was used to represent stress-sensitivity of the fractures. This allows the opening and closing of fracture apertures with changes in fluid pressures within fracture segments. Pressure increases in the formations overlying the Tully limestone, indicating fluid flow, was observed due to the hydraulic stimulation; and the impact of these increased pressures on brine migration towards the surface was considered.

03 NATURAL GAS↗

A polyoxometalate flow battery

A redox flow battery utilizing two, three-electron polyoxometalate redox couples (SiV V 3 W VI 9 O 40 7– /SiV IV 3 W VI 9 O 40 10- and SiV IV 3 W VI 9 O 40 10- /SiV IV 3 W V 3 W VI 6 O 40 13- ) was investigated for use in stationary storage in either aqueous or non-aqueous conditions. The aqueous battery had coulombic efficiencies greater than 95% with relatively low capacity fading over 100 cycles. Infrared studies showed there was no decomposition of the compound under these conditions. The non-aqueous analog had a higher operating voltage but at the expense of coulombic efficiency. The spontaneous formation of these clusters by self-assembly facilitates recovery of the battery after being subjected to reversed polarity. Polyoxometalates offer a new approach to stationary storage materials because they are capable of undergoing multi-electron reactions and are stable over a wide range of pH values and temperatures.