Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

DEVELOPMENT OF INEXPENSIVE HIGH TEMPERATURE NITI-BASED SHAPE MEMORY ALLOYS FOR POWDER BED ADDITIVE MANUFACTURING

NiTi and NiTi-based Shape Memory Alloys (SMA) exhibit a reversible solid-state phase transformation from martensite to austenite driven by thermal energy. High temperature (Mf>100°C) SMAs are martensite at room temperature and can be fabricated into solid-state actuators that return to a pre-programmed shape against a designed load after heating to transformation threshold. Reactive as-fabricated additively manufactured parts (4-D printing) is the current state of the art in manufacturing of SMAs but requires compositions compliant to rapid solidification. Existing actuator designs are developed from commercially available, highly investigated material compositions. However, existing high temperature high performance (high actuation strain, low thermal hysteresis) shape memory alloys contain significant (>10% at.) portions of high-cost Platinum Group Metals (PGMs). It is of significant scientific interest to investigate material compositions that are peer performing or superior to PGMs whose constituent elements represent a significant cost savings. Shape memory alloy properties vary significantly with small (0.1% at.) compositional changes making robust investigative sample sets very large. Computational material design can be deployed to shrink the compositional space of possible alloy combinations and reduce the experimental load in material discovery. Investigating shape memory effect (SME) and validating process additive process parameters for a single novel composition is cost intensive in both time and consumed materials. Additionally, sub-optimal processing, oxygen, or solidification rate sensitivity could render additively manufacturing specimens without micro, macro cracks, or significant chemical variance impossible. Unfortunately, such failure susceptibility cannot be simulated. Therefore, a research pathway to validate novel shape memory alloy compositions for powder bed fusion additive manufacturing without the need for powdered feedstock is also proposed. This research investigates novel high temperature shape memory alloys for actuators without platinum group alloying elements to discover one that could be commercially viable as an additive manufacturing feedstock.

Sundermann, Tayler↗

Ultrasonic Phased Arrays and Interactive Reflectivity Tomography for Nondestructive Inspection of Injection and Production Wells in Geothermal Energy Systems (Quarterly Research Performance Progress Report (2015 Q3))

For the past quarter, we have placed our effort in implementing the first version of the Model-Based Iterative Reconstruction (MBIR) algorithm, assembling and testing the electronics, designing transducers mounts, and defining our laboratory test samples. We have successfully developed the first implementation of MBIR for ultrasound imaging. The current algorithm was tested with synthetic data and we are currently making new modifications for the reconstruction of real ultrasound data. Beside assembling and testing the electronics, we developed a LabView graphic user interface (GUI) to fully control the ultrasonic phased array, adjust the time-delays of the transducers, and store the measured reflections. As part of preparing for a laboratory-scale demonstration, the design and fabrication of the laboratory samples has begun. Three cement blocks with embedded objects will be fabricated, characterized, and used to demonstrate the capabilities of the system. During the next quarter, we will continue to improve the current MBIR forward model and integrate the reconstruction code with the LabView GUI. In addition, we will define focal laws for the ultrasonic phased array and perform the laboratory demonstration. We expect to perform laboratory demonstration by the end of October 2015.

15 GEOTHERMAL ENERGY↗

Initial experimental demonstration of the principles of a xenon gas shield designed to protect optical components from soft x-ray induced opacity (blanking) in high energy density experiments

The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1 , 250–300 eV). Blanking of fused silica (SiO 2 ) was measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2 . A shield test device consisting of a 30 nm silicon nitride (Si 3 N 4 ) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.

42 ENGINEERING↗

Simple Check Valves for Microfluidic Devices

A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

Willis, Peter A.↗

Mars aqueous chemistry experiment

Mars Aqueous Chemistry Experiment (MACE) is designed to conduct a variety of measurements on regolith samples, encompassing mineral phase analyses, chemical interactions with H2O, and physical properties determinations. From these data, much can be learned or inferred regarding the past weathering environment, the contemporaneous soil micro-environments, and the general chemical and physical state of the Martian regolith. By analyzing both soil and duricrust samples, the nature of the latter may become more apparent. Sites may be characterized for comparative purposes and criteria could be set for selection of high priority materials on future sample return missions. The second year of the MACE project has shown significant progress in two major areas. MACE Instrument concept definition is a baseline design that has been generated for the complete MACE instrument, including definition of analysis modes, mass estimates and thermal model. The design includes multiple reagent reservoirs, 10 discrete analysis cells, sample manipulation capability, and thermal control. The MACE Measurement subsystems development progress is reported regarding measurement capabilities for aqueous ion sensing, evolved gas sensing, solution conductivity measurement, reagent addition (titration) capabilities, and optical sensing of suspended particles.

Clark, Benton C.↗

Spatial identification of traps in AlGaN/GaN heterostructures by the combination of lateral and vertical electrical stress measurements

We present a methodology and the corresponding experimental results to identify the exact location of the traps that induce hot electron trapping in AlGaN/GaN heterostructures grown on Si substrates. The methodology is based on a combination of lateral and vertical electrical stress measurements employing three ohmic terminals on the test sample structure with different GaN buffer designs. By monitoring the evolution of the lateral current during lateral as well as vertical stress application, we investigate the trapping/detrapping behaviors of the hot electrons and identify that the traps correlated with current degradation are in fact located in the GaN buffer layers. The trap activation energies (0.38–0.39 eV and 0.57–0.59 eV) extracted from either lateral or vertical stress measurements are in good agreement with each other, also confirming the identification. By further comparing the trapping behaviors in two samples with different growth conditions of an unintentionally doped GaN layer, we conclude that the traps are most likely in the unintentionally doped GaN layer but of different origins. It is suggested that the 0.38–0.39 eV trap is related to residual carbon incorporation while the 0.57–0.59 eV trap is correlated with native defects or complexes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and feasibility of a novel program of cervical screening in Nigeria: self-sampled HPV testing paired with visual triage

Background: Accelerated global control of cervical cancer would require primary prevention with human papillomavirus (HPV) vaccination in addition to novel screening program strategies that are simple, inexpensive, and effective. We present the feasibility and outcome of a community-based HPV self-sampled screening program. Methods: In Ile Ife, Nigeria, 9406 women aged 30–49 years collected vaginal self-samples, which were tested for HPV in the local study laboratory using Hybrid Capture-2 (HC2) (Qiagen). HPV-positive women were referred to the colposcopy clinic. Gynecologist colposcopic impression dictated immediate management; biopsies were taken when definite acetowhitening was present to produce a histopathologic reference standard of precancer (and to determine final clinical management). Retrospective linkage to the medical records identified 442 of 9406 women living with HIV (WLWH). Results: With self-sampling, it was possible to screen more than 100 women per day per clinic. Following an audio-visual presentation and in-person instructions, overall acceptability of self-sampling was very high (81.2% women preferring self-sampling over clinician collection). HPV positivity was found in 17.3% of women. Intensive follow-up contributed to 85.9% attendance at the colposcopy clinic. Of those referred, 8.2% were initially treated with thermal ablation and 5.6% with large loop excision of transformation zone (LLETZ). Full visibility of the squamocolumnar junction, necessary for optimal visual triage and ablation, declined from 68.5% at age 30 to 35.4% at age 49. CIN2+ and CIN3+ (CIN- Cervical intraepithelial neoplasia), including five cancers, were identified by histology in 5.9 and 3.2% of the HPV-positive women, respectively (0.9 and 0.5% of the total screening population), leading to additional treatment as indicated. The prevalences of HPV infection and CIN2+ were substantially higher (40.5 and 2.5%, respectively) among WLWH. Colposcopic impression led to over- and under-treatment compared to the histopathology reference standard. Conclusion: A cervical cancer screening program using self-sampled HPV testing, with colposcopic immediate management of women positive for HPV, proved feasible in Nigeria. Based on the collected specimens and images, we are now evaluating the use of a combination of partial HPV typing and automated visual evaluation (AVE) of cervical images to improve the accuracy of the screening program.

59 BASIC BIOLOGICAL SCIENCES↗

Magnet Lab Highlight: Upper critical field reaches 90 tesla near the Mott transition in fulleride superconductors

The alkali-doped fullerides provide the first example of a transition from a three-dimensional Mott insulator to a superconductor, enabling the effects of both dimensionality and electron correlation on superconductivity to be explored. Chemically the alkali species tunes the superconductivity in the vicinity of the the Mott transition via sample volume. Measuring the relationship between the superconducting transition temperature and upper critical field reveals a crossover from weak- to strong-coupling associated with the dynamical Jahn–Teller effect as the Mott transition is approached. The use of pulsed magnets is required because the upper critical field is enhanced in the vicinity of the Mott insulating phase, reaching 90 T for RbxCs3-xC60 — the highest among cubic crystals. This required close collaboration between Prof Kasahara’s group and the Mag Lab to design rf-measurements compatible with sample encapsulation in an inert atmosphere. The concomitant increase of pairing strength with lattice volume near the Mott transition suggest that the cooperative interplay between molecular electronic structure and strong electron correlations plays a key role in realizing robust superconductivity (with high-T C and high-H C2 ).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data sampling system for monitor and control station

System design is based on development of standardized, interchangeable modules that minimize power dissipation, interconnecting cables and size. Maximum flexibility is achieved by using building block approach where all data modules are identical and are connected at any remote location and addressed in random fashion from central unit.

Source record↗

A review of design concepts for the Advanced Fluids Module (AFM) project

This paper reviews preliminary fluid module design concepts for the Advanced Fluids Module (AFM) project. The objective of this effort is to provide a facility that can handle a wide variety of fluids experiments. Sample science requirements were written and conceptual designs were subsequently generated during the last year. Experiments from the following fluid physics subject areas were used as conceptual design drivers: static and dynamic interfacial phenomena; bubble/droplet thermocapillary migration; surface tension convection and instabilities; thermal/solutal convection; pool boiling; and multiphase flow. After the conceptual designs were completed, the next phase attempted to combine experiments capabilities into a multipurpose, multiuser apparatus configured for the Space Station Freedom. It was found that all the fluid subject areas considered could be accommodated by three basic types of fluids modules. These modules are the Static Fluid Cell Module, the Dynamic Fluid Cell Module, and the Multiphase Flow Module. Descriptions of these preliminary modules designs and their particular sub-systems (e.g., fluid and thermal systems) are discussed. These designs will be refined as the nature of the flight program becomes clearer over the next six to twelve months.

Hill, Myron E.↗

Development of Experiment Kits for Processing Biological Samples In-Flight on SLS-2

The design of the hematology experiment kits for SLS-2 has resulted in a modular, flexible configuration which maximizes crew efficiency and minimizes error and confusion when dealing with over 1200 different components over the course of the mission. The kit layouts proved to be very easy to use and their packaging design provided for positive, secure containment of the many small components. The secondary Zero(Tm) box enclosure also provided an effective means for transport of the kits within the Spacelab and for grouping individual kits by flight day usage. The kits are readily adaptable to use on future flights by simply replacing the inner components as required and changing the labelling scheme to match new mission requirements.

Jaquez, R.↗

Returning Geological Samples from Mars

Mars Ascent Vehicle (MAV) Study: Design challenges associated with Mars; Remote; Temperature; Atmosphere; Radiation; Dust. Challenges unique to MAV: No vehicle has ever left the surface of Mars; Completely autonomous; Physical system extremely limited; Martian environment creates a number of issues with traditional propulsion systems.

Yaghoubi, Darius↗

A Mars Ascent Vehicle for Potential Mars Sample Return

This paper will cover the conceptual design of a Mars Ascent Vehicle (MAV) and efforts underway to raise the TRL at both the component and system levels. A system down select was executed resulting in a Hybrid Propulsion based Single Stage To Orbit (SSTO) MAV baseline architecture. This paper covers the Point o f Departure design, as well as results of hardware developments that will be tested in several upcoming flight opportunities.

Shotwell, Robert↗

Genesis Mission Design

The Genesis spacecraft will collect solar wind samples from a halo orbit about the Sun-Earth L1 point for two years, returning those samples to Earth in 2003 for on-Earth analysis and examination.

Genesis↗

A Mars Ascent Vehicle for Potential Mars Sample Return

This paper will cover the conceptual design of a Mars Ascent Vehicle (MAV) and efforts underway to raise the TRL at both the component and system levels. A system down select was executed resulting in a Hybrid Propulsion based Single Stage To Orbit (SSTO) MAV baseline architecture. This paper covers the Point of Departure design, as well as results of hardware developments that will be tested in several upcoming flight opportunities.

Dankanich, John↗

Vehicle Modeling During the Burning of Thermally Thick Samples in the Saffire V Experiments

In order to design a safer spacecraft in terms of fire prevention, detection and cleanup, the transport of combustion products and heat must be predicted. Large-scale fire data was provided by the Saffire payload within Northrup Grumman’s Cygnus vehicle after a resupply mission to the ISS. Solid materials, including thick thermoplastic samples were ignited to study flame spread and the effect a fire has on a vehicle. Sensors that measured species and temperature were placed within Cygnus. A model using Pyrosim was developed to predict the thick fuel burn events from Saffire V by using sensor data from Cygnus. The heat transfer coefficient between the cabin air and cargo was previously calibrated using the cotton fuel burn event, and provided a good prediction of the temperature response within the vehicle during the two thick fuel experiments. The difference between the Saffire inlet CO 2 sensor, and the forward port standoff CO 2 sensor, which is the closest to the Saffire outlet, was used as an input into the model. This method provided an excellent prediction of the CO 2 response in the other parts of the Cygnus.

fire safety↗

Correction for turbidity and pH interference for in situ hexavalent chromium monitoring - 16297

Hexavalent chromium is of increasing concern worldwide because of its toxicity, mobility in aqueous media, and relative abundance in waste effluent from a variety of industrial processes. Some of that waste has reached groundwater aquifers. Because of these factors, the fate and transport of hexavalent chromium in aquifers is of great importance for evaluating risk to fresh water sources and to the biosphere, and for designing means for abatement or remediation. Conventional sampling and analysis of groundwater samples from wells is labor intensive and therefore budget limited. The result is inadequate temporal and spatial characterization of contaminant plumes with respect to rate of movement, concentrations, and contaminant flux. A submersible hexavalent chromium sensor designed for extended-term deployment and based on ultraviolet colorimetry has been developed and tested at the Hanford Site, Washington. Adaptation of the method for in situ measurements requires automatic correction for sample turbidity and pH for every measurement. Turbidity is compensated nephelometrically. A method for estimating sample pH based on absorbance measurements made using two different wavelengths is presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗