Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Two-dimensional analytical model of twin jet shielding

Estimation of the impact of jet noise requires analytical modeling not only of the noise source mechanism, but also of the propagation of noise from the source to receiver. One factor which influences the jet noise path is shielding of one jet by another in a twin jet configuration. An analytical model is developed to investigate the shielding phenomenon. The two-dimensional wave equation is solved for a stationary line source impinging upon a cylinder of heated flow. The solution estimates the diffraction and scattering of the incident sound wave by the shielding jet in a plane normal to the jet axis. The frequency dependence of the normalized sound pressure estimated by the model is found to agree in form with empirical data. The azimuthal redistribution of the incident sound shows that, as the frequency of maximum shielding is approached, the scattered sound becomes more highly concentrated into lobes adjacent to the shielding zone.

Gerhold, C. H.↗

MAGNETIC FIELD CONFIGURATION AT THE GALACTIC CENTER INVESTIGATED BY WIDE-FIELD NEAR-INFRARED POLARIMETRY: TRANSITION FROM A TOROIDAL TO A POLOIDAL MAGNETIC FIELD

We present a large-scale view of the magnetic field (MF) in the central 2{sup 0} x 2{sup 0} region of our Galaxy. The polarization of point sources has been measured in the J, H, and K{sub S} bands using the near-infrared polarimetric camera SIRPOL on the 1.4 m Infrared Survey Facility telescope. Comparing the Stokes parameters between high extinction stars and relatively low extinction ones, we obtain polarization originating from magnetically aligned dust grains in the central few hundred parsecs of our Galaxy. We find that near the Galactic plane, the MF is almost parallel to the Galactic plane (i.e., toroidal configuration), but at high Galactic latitudes (|b | >0.{sup 0}4) the field is nearly perpendicular to the plane (i.e., poloidal configuration). This is the first detection of a smooth transition of the large-scale MF configuration in this region.

79 ASTRONOMY AND ASTROPHYSICS↗

3D modeling of the electron energy distribution function in negative hydrogen ion sources

For optimization and accurate prediction of the amount of H-ion production in negative ion sources, analysis of electron energy distribution function (EEDF) is necessary. We are developing a numerical code which analyzes EEDF in the tandem-type arc-discharge source. It is a three-dimensional Monte Carlo simulation code with realistic geometry and magnetic configuration. Coulomb collision between electrons is treated with the ''binary collision'' model and collisions with hydrogen species are treated with the ''null-collision'' method. We applied this code to the analysis of the JAEA 10 A negative ion source. The numerical result shows that the obtained EEDF is in good agreement with experimental results.

43 PARTICLE ACCELERATORS↗

Hybrid Natural Gas Geothermal Combined Cycle Power Plant Analysis

Low temperature geothermal resources, including those associated with oil and gas production, are an underutilized source of low carbon energy. The present work investigates coupling of low-temperature geothermal resources with concentrating solar and/or natural gas energy sources to increase the number of locations at which power generation from low temperature geothermal resources would be technically and economically viable. Stand-alone and hybrid geothermal power cycles are simulated using SimTech IPSEpro process modeling software. Design point strategies for a hybrid power cycle that may operate with either a single heat source or two simultaneous heat input sources are considered. Additionally, off-design power plant operation is investigated to consider the impacts of the heat source availability and ambient temperature variations. The off-design analysis utilizes a modeling tool that predicts power plant performance at each time step as a function of topping cycle heat input (from gas or solar), bottoming cycle heat input (from geothermal), and ambient temperature. Addition of a steam topping cycle to an organic Rankine cycle geothermal power plant provides opportunities to increase the efficiency and power output relative to a stand-alone geothermal power plant. Additionally, use of the waste heat from gas turbine power generation in a geothermal bottoming cycle provides opportunities to increase the amount of power generation associated with each unit of carbon dioxide emitted. This paper will describe the hybrid plant configuration evaluated, discuss the predicted power cycle performance, and compare with stand-alone natural gas and geothermal power generation cases. The power cycle investigated is expected to be applicable for use with conventional hydrothermal resources as well as with geologic thermal energy storage applications and/or enhanced geothermal systems. The steam topping cycle could use a concentrated solar heat source for fully renewable hybrid plant configuration. A plant initially constructed with a natural gas topping cycle heat source could be converted to a solar heat source part way though the power cycle operational life to achieve life cycle carbon emission reductions.

concentrating solar power↗

Ferroelectric Devices Emit Charged Particles and Radiation

Devices called solid-state ferroelectric- based sources (SSFBSs) are under development as sources of electrons, ions, ultraviolet light, and x-rays for diverse applications in characterization and processing of materials. Whereas heretofore it has been necessary to use a different device to generate each of the aforementioned species of charged particles or radiation, a single SSFBS can be configured and operated to selectively generate any of the species as needed using a single source. Relative to comparable prior sources based, variously, on field emission, thermionic emission, and gaseous discharge plasmas, SSFBSs demand less power, and are compact and lightweight. An SSFBS exploits the unique physical characteristics of a ferroelectric material in the presence of a high-frequency pulsed electric field. The basic building block of an SSFBS is a ferroelectric cathode -- a ferroelectric wafer with a solid electrode covering its rear face and a grid electrode on its front face (see figure). The application of a voltage pulse -- typically having amplitude of several kilovolts and duration of several nanoseconds -- causes dense surface plasma to form near the grid wires on the front surface.

Bar-Cohen, Yoseph↗

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.

07 ISOTOPE AND RADIATION SOURCES↗

Recent progress on the APOLLO3 calculation scheme for the FLUOLE2 experiment

Studies of the neutron fluence on reactor pressure vessel and the correlated reactor lifetime issues require very good knowledge of the neutron source distribution in the reactor core and especially in the peripheral region. The FLUOLE2 experiment offers an appropriate starting configuration to investigate the possibility of using the APOLLO3 deterministic code with a two-step calculation scheme. It enables us to calculate a pin-by-pin neutron source distribution in the core, then to carry out the neutron propagation from the core to neutron detectors. In this paper, we focus on a calculation scheme dedicated to the determination of core neutron source distribution using APOLLO3 with the SHEM281 energy mesh, a Method of Characteristics (MOC) to solve the transport equation for the lattice computation step and a 20-groups 3D computation using the MINARET SN solver of APOLLO3. Reactivity and pin-by-pin reaction rate results have been analyzed. Results obtained with both lattice and core computations show a good agreement with those produced through a reference calculation using the TRIPOLI-4 Monte Carlo transport code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The DELVE Quadruple Quasar Search. I. A Lensed Low-luminosity Active Galactic Nucleus

A quadruply lensed source, J125856.3–031944, has been discovered using the DELVE survey and Wide-field Infrared Survey Explorer W1–W2 colors. Follow-up direct imaging carried out with the Magellan Baade 6.5 m telescope is analyzed, as is spectroscopy from the 2.5 m Nordic Optical Telescope. The lensed image configuration is kite-like, with the major axis of the lensing galaxy along the symmetry axis of the kite, and with the faintest image at its tail. Redward of 6000 Å, the tail image is strongly blended with the lensing galaxy. The Sloan g direct imaging carried out with Magellan permits deblending. As the lensed image configuration is nearly circular, simple models give high predicted magnifications for all four images. The source’s narrow emission lines at redshift z = 2.225 and low intrinsic luminosity qualify it as a type 2 active galactic nucleus. The Magellan image shows a substantial residual that suggests a second lensing galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Problems with Some Current Water Models for Close Pair Interactions That Are Not Near the Minimum Energy

The ability of an empirical, polarizable model of water to predict a thermal ensemble of molecular configurations at ambient conditions was examined using first-principle quantum mechanics. The empirical model of water selected for this evaluation was the TTM2-F model. The quantum mechanical methodology selected was the second-order Møller-Plesset model (MP2). Only pairwise interaction energies were considered. Significant deviations from the empirical model were found. Similar results were found for ad-hoc comparisons with several other common water models including the TIP3P, TIP4P, TIP4P-FQ, TIP5P, TTM2.1-F, TTM2.2- F, TTM3-F, and POL5/QZ potential models. Our results show that spatially close dimer configurations with interaction energies notably above the potential well minimum (but are still thermally accessible at ambient conditions) are the source of the largest deviations. To assist others in future water model parametrizations we report the MP2 near complete basis set limit energies for 840 water dimer configurations sampled from an approximate thermal ensemble at ambient conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study on an azimuthal line cusp ion source for the KSTAR neutral beam injector

In this study it is found that the cusp magnetic field configuration of an anode bucket influences the primary electron behavior. An electron orbit code (ELEORBIT code) showed that an azimuthal line cusp (cusp lines run azimuthally with respect to the beam extraction direction) provides a longer primary electron confinement time than an axial line cusp configuration. Experimentally higher plasma densities were obtained under the same arc power when the azimuthal cusp chamber was used. The newly designed azimuthal cusp bucket has been investigated in an effort to increase the plasma density in its plasma generator per arc power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Base Engine for Solar Stirling Power

A new concept in Stirling engine technology is embodied in the base engine now being developed at Stirling Thermal Motors, Inc. This is a versatile energy conversion unit suitable for many different applications and heat sources. The base engine, rated 40 kW at 2800 RPM, is a four-cylinder, double-acting variable displacement Stirling engine with pressurized crankcase and rotating shaft seal. Remote-heating technology is incorporated with a stacked-heat-exchanger configuration and a liquid metal heat pipe connected to a distinctly separate combustor or other heat source. High efficiency over a wide range of operating conditions, long life, low manufacturing cost and low material cost are specifically emphasized. The base engine, its design philosophy and approach, its projected performance, and some of its more attractive applications are described.

Meijer, R. J.↗

Design and development of a portable flash X-ray source driven by battery powered compact Marx generator

The design, construction and operational characteristics of a portable flash X-ray source driven by battery-powered compact Marx is reported. The novel configuration of compact Marx utilizes hollow capacitors in successive stages to enhance the erection reliability. The characteristic impedance of this system is ∼ 200 Ω. At discharge of ∼ 22 kV, >200 kV output pulse of 60 ns duration (FWHM) with rise time of <5 ns (10% - 90%) is produced. The pulser requires Nitrogen gas pressurization up to 3 atm for operation at maximum rating. The Marx generator assembly is fitted in to a stainless steel tube of 10 cm diameter and 1.2 m length. While using a demountable sealed X-ray tube of matched impedance, this device produces an X-ray pulse of approximately ∼ 30 ns duration and has maximum energy of ∼ 200 keV. This true tabletop device is able to produce dose up to 100 mR per shot, measured at the distance of 30 cm from output window. The focal spot size has been passively confirmed to be in the sub-millimeter (<1 mm) range. (author)

43 PARTICLE ACCELERATORS↗

Surface Slope Metrology on Deformable Soft X-ray Mirrors

We report on the current state of surface slope metrology on deformable mirrors for soft x-rays at the Advanced Light Source (ALS). While we are developing techniques for in situ at-wavelength tuning, we are refining methods of ex situ visible-light optical metrology to achieve sub-100-nrad accuracy. This paper reports on laboratory studies, measurements and tuning of a deformable test-KB mirror prior to its use. The test mirror was bent to a much different optical configuration than its original design, achieving a 0.38 micro-radian residual slope error. Modeling shows that in some cases, by including the image conjugate distance as an additional free parameter in the alignment, along with the two force couples, fourth-order tangential shape errors (the so-called bird shape) can be reduced or eliminated.

47 OTHER INSTRUMENTATION↗

Surface Slope Metrology on Deformable Soft X-ray Mirrors

We report on the current state of surface slope metrology on deformable mirrors for soft x-rays at the Advanced Light Source (ALS). While we are developing techniques for in situ at-wavelength tuning, we are refining methods of ex situvisible-light optical metrology to achieve sub-100-nrad accuracy. This paper reports on laboratory studies, measurements and tuning of a deformable test-KB mirror prior to its use. The test mirror was bent to a much different optical configuration than its original design, achieving a 0.38 micro-radian residual slope error. Modeling shows that in some cases, by including the image conjugate distance as an additional free parameter in the alignment, along with the two force couples, fourth-order tangential shape errors (the so-called bird shape) can be reduced or eliminated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion beams extraction and measurements of plasma parameters on a multi-frequencies microwaves large bore ECRIS with permanent magnets

We have developed an all-permanent magnet large bore electron cyclotron resonance ion source (ECRIS) for broad ion beam processing. The cylindrically comb-shaped magnetic field configuration is adopted for efficient plasma production and good magnetic confinement. To compensate for disadvantages of fixed magnetic configuration, a traveling wave tube amplifier (TWTA) is used. In the comb-shaped ECRIS, it is difficult to achieve controlling ion beam profiles in the whole inside the chamber by using even single frequency-controllable TWTA (11-13GHz), because of large bore size with all-magnets. We have tried controlling profiles of plasma parameters and then those of extracted ion beams by launching two largely different frequencies simultaneously, i.e., multi-frequencies microwaves. Here we report ion beam profiles and corresponding plasma parameters under various experimental conditions, dependence of ion beams against extraction voltages, and influence of different electrode positions on the electron density profile.

43 PARTICLE ACCELERATORS↗

Combining configurational energies and forces for molecular force field optimization

While quantum chemical simulations have been increasingly used as an invaluable source of information for atomistic model development, the high computational expenses typically associated with these techniques often limit thorough sampling of the systems of interest. It is therefore of great practical importance to use all available information as efficiently as possible, and in a way that allows for consistent addition of constraints that may be provided by macroscopic experiments. We propose a simple approach that combines information from configurational energies and forces generated in a molecular dynamics simulation to increase the effective number of samples. Subsequently, this information is used to optimize a molecular force field by minimizing the statistical distance similarity metric. We also illustrate the methodology on an example of a trajectory of configurations generated in equilibrium molecular dynamics simulations of argon and water and compare the results with those based on the force matching method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High efficiency light source using solid-state emitter and down-conversion material

A light emitting apparatus includes a source of light for emitting light; a down conversion material receiving the emitted light, and converting the emitted light into transmitted light and backward transmitted light; and an optic device configured to receive the backward transmitted light and transfer the backward transmitted light outside of the optic device. The source of light is a semiconductor light emitting diode, a laser diode (LD), or a resonant cavity light emitting diode (RCLED). The down conversion material includes one of phosphor or other material for absorbing light in one spectral region and emitting light in another spectral region. The optic device, or lens, includes light transmissive material.

Narendran, Nadarajah↗

Undulator beamline of the Brockhouse sector at the Canadian Light Source

The Brockhouse project at the Canadian Light Source plans the construction of three beamlines, two wiggler beamlines, and one undulator beamline, that will be dedicated to x-ray diffraction and scattering. In this work, we will describe the undulator beamline main components and performance parameters, obtained from ray tracing using XOP-SHADOW codes. The undulator beamline will operate from 4.95 to 21 keV, using a 20 mm period hybrid undulator placed upstream of the wiggler in the same straight section. The beamline optics design was developed in cooperation with the Brazilian Synchrotron - LNLS. The beamline will have a double crystal monochromator with the options of Si(111) or Si(311) crystal pairs followed by two mirrors in the KB configuration to focus the beam at the sample position. The high brilliance of the undulator source will produce a very high flux of ∼10{sup 13} photons/s and high energy resolution into a small focus of 170 μm horizontal and 20-60 μm vertical, depending on the optical configuration and energy chosen. Two multi-axis goniometer experimental stations with area detectors and analyzers are foreseen to enable diffraction, resonant and inelastic scattering experiments, and SAXS/WAXS experiments with high resolution and time resolving capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗