Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Variability in Performance of a Machine Learning Seismicity Catalog: Central Italy, 2016–2017

Machine learning (ML) catalogs contain many more earthquakes than routine catalogs, but their performance in phase picking and earthquake detection has not been fully evaluated. We develop station‐level detection probabilities using logistic regression and combine them across a seismic network to compute spatial magnitude‐of‐completeness fields. We apply this approach to two catalogs from the 2016–2017 Central Italy sequence that were constructed from the same seismic network, one routine and one ML‐based. At the station level, the ML picker increases detection sensitivity by identifying smaller magnitude events and detecting earthquakes at greater distances. Spatially, the magnitude of completeness decreases substantially, with median values shifting from 1.6 to 0.5 for P waves and from 1.7 to 0.5 for S waves. However, the ML catalog also shows greater variability in station‐level performance than the routine catalog. These results demonstrate that ML‐based improvements in detectability are widespread but spatially nonuniform, highlighting their benefits, their limitations, and the potential for further improvements.

15 GEOTHERMAL ENERGY↗

A simulation of I 2 S-LWR selected transients

The Integral Inherently Safe (I 2 S-LWR) reactor was designed to improve the safety performance of PWR types reactors, and several design basis accidents were eliminated using innovative approaches to the I 2 S-LWR plant layout. However, some accidents such as station blackout (SBO), main steam line break (MSLB) type accident – the secondary hot leg break (SHLB) – were deemed statistically relevant, and the work performed here was to simulate these events using the system thermal–hydraulics code RELAP5 coupled to the 3D spatial kinetics code PARCS. The safety response of the reactor to a station blackout is predicted to be acceptable at both beginning of cycle (BOC) and end of cycle EOC core conditions with either the UO 2 or U 3 Si 2 fuel options considered here. In the analysis of the SHLB performed here, an unprotected (no SCRAM) condition was assumed to highlight the I 2 S-LWR capabilities. Results indicate that with the UO 2 core, the fuel temperatures rise notably, but no fuel melting was predicted and departure from nucleate boiling ratio (DNBR) limits were not exceeded. Similarly, the U 3 Si 2 fuel performed well, but with lower fuel temperatures and decreased DNBR. Following the break of the steam line in the I 2 S-LWR, shutdown is achieved after about two minutes via negative reactivity from loss of primary flow. In all cases considered, the I 2 S-LWR appears to accomplish the goals of increased safety performance. Further design improvements and other fuel options may marginally improve on the observed safety performance. Additionally, higher fidelity analysis with the next generation subchannel, Computational Fluid Dynamics (CFD), or full core transport may be useful in refining the prediction of the peak fuel and cladding temperatures, as well limiting DNBR during the accidents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Functional Distributed Fiber Sensors for Pipeline Monitoring and Methane Detections. Final Report

As an abundant and cheap fossil energy source, natural gas has become a significant energy supply to support the United States’ economy. However, the large-scale extraction and utilization of natural gas also impose significant challenges on methane leakage. This problem is exacerbated by aging gas utility delivery systems, including interstate high-pressure pipelines, storage, and transmission facilities. This project aims to develop a cost-effective fiber optical sensing method that can perform multi-parameter real-time measurements of natural gas pipelines across long interrogation distances up to 100 km with 1-meter spatial resolution. This sensing tool can evaluate overall pipeline efficiency and reduce methane emissions for mid-stream methane infrastructures. To accomplish this objective, research and development efforts funded by this project have resulted in the following accomplishments: This project successfully has developed new functional sensory polymer materials using Metal-Organic Frameworks (MOFs) that can be coated on optical fiber through the reel-to-reel coating process. Functional polymer-coated optical fibers can perform sensitive methane detection through evanescence wave interaction and strain-based measurements to achieve 1% detection sensitivities. The new sensors fibers support both distributed measurements and multiplexed fiber sensors array for multi-point measurements. This project developed and optimized a new multi-core optical fiber that supports simultaneous and distributed measurements of strain and temperatures with 1-meter spatial resolutions across up to 100-km interrogation distance. This new fiber, combined with sensory polymercoated fiber, could perform both distributed temperature and methane detections. This project developed a new artificial intelligence big data algorithm approach that can effectively analyze high-resolution data harnessed by distributed fiber sensors to protect natural gas pipelines against external threats and detect internal defects induced by corrosion. Working with our industry partner, this project developed new optical fibers that support fiber sensor fabrications through polymer coating after the fibers are drawn. These new fibers eliminate the need for direct sensor fabrication when the fiber is fabricated on a fiber draw tower, which drastically expands fiber sensors' applicability. This research project has significantly advanced the distributed fiber sensing technology. It will dramatically increase the applicability and adaptability of distributed fiber sensors for a wide array of applications in energy, sustainability, and environmental science, including structural health monitoring of natural gas pipelines, oil infrastructures, hydrogen facilities, and environmental monitoring of carbon storage sites, water supply systems, and others.

03 NATURAL GAS↗

Dual Polarity Ion Confinement and Mobility Separations

Structures for Lossless Ion Manipulations (SLIM) have been rapidly gaining prominence for applications where ultra-high resolution Ion Mobility (IM) separations are desired to provide performance features and information unattainable using the currently available IM platforms. Although most routine analyses are done in either positive or negative polarity modes, there are significant benefits to both, potentially making them highly complementary if performed simultaneously. In the effort to develop a robust dual polarity IM platform, we explored an evaluation of a novel SLIM platform developed to perform simultaneous cationic and anionic IM separations (i.e. without requiring polarity switching).

Attah, Isaac K.↗

Benchmarking a novel ultrasound-CT fusion system for respiratory motion management in radiotherapy: Assessment of spatio-temporal characteristics and comparison to 4DCT

Management of respiratory motion during radiation therapy requires treatment planning and simulation using imaging modalities that possess sufficient spatio-temporal accuracy and precision. An investigation into the use of a novel ultrasound (United States) imaging system for assessment of respiratory motion is presented, exploiting its good soft tissue contrast and temporal precision. The system dynamically superimposes the appropriate image plane sampled from a reference CT data set with the corresponding US B-mode image. An articulating arm is used for spatial registration. While the focus of the study was to quantify the system's ability to track respiratory motion, certain unique spatial calibration procedures were devised that render the software potentially valuable to the general research community. These include direct access to all transformation matrix elements and image scaling factors, a manual latency correction function, and a three-point spatial registration procedure that allows the system to be used in any room possessing a traditional radiotherapy laser localization system. Counter-intuitively, it was discovered that a manual procedure for calibrating certain transformation matrix elements produced superior accuracy to that of an algorithmic Levenberg-Marquardt optimization method. The absolute spatial accuracy was verified by comparing the physical locations of phantom test objects measured using the spatially registered US system, and using data from a 3DCT scan of the phantom as a reference. The spatial accuracy of the display superposition was also tested in a similar manner. The system's dynamic properties were then assessed using three methods. First, the overall system response time was studied using a programmable motion phantom. This included US video update, articulating arm update, CT data set resampling, and image display. The next investigation verified the system's ability to measure the range of motion of a moving anatomical test phantom that possessed both high and low contrast test objects. Finally, the system's performance was compared to that of a four-dimensional CT (4DCT) data set. The absolute spatial and display superposition accuracy was found to be better than 2 mm and typically 1 mm. Overall dynamic system response was adequate to produce a mean relative positional error of less than 1 mm if an empiric latency correction of 3 video frames was incorporated. The dynamic CT/US display mode was able to assess phantom motion for both high and low contrast test objects to within 1 mm, and compared favorably to the 4DCT data. The 4DCT movie loop accurately assessed the target motion for both of the high and low contrast objects tested, but the minimum intensity and average intensity reconstructions did not. This investigation demonstrated that this US system possesses sufficient spatio-temporal accuracy to properly assess respiratory motion. Future work will seek to demonstrate efficacy in its clinical application to respiratory motion assessment, particularly for sites in the upper abdomen, where low tissue contrast is evident.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absolute Hugoniot measurements from a spherically convergent shock using x-ray radiography

Here, the canonical high pressure equation of state measurement is to induce a shock wave in the sample material and measure two mechanical properties of the shocked material or shock wave. For accurate measurements, the experiment is normally designed to generate a planar shock which is as steady as possible in space and time, and a single state is measured. A converging shock strengthens as it propagates, so a range of shock pressures is induced in a single experiment. However, equation of state measurements must then account for spatial and temporal gradients. We have used x-ray radiography of spherically converging shocks to determine states along the shock Hugoniot. The radius-time history of the shock, and thus its speed, was measured by radiographing the position of the shock front as a function of time using an x-ray streak camera. The density profile of the shock was then inferred from the x-ray transmission at each instant of time. Simultaneous measurement of the density at the shock front and the shock speed determines an absolute mechanical Hugoniot state. The density profile was reconstructed using the known, unshocked density which strongly constrains the density jump at the shock front. The radiographic configuration and streak camera behavior were treated in detail to reduce systematic errors. Measurements were performed on the Omega and National Ignition Facility lasers, using a hohlraum to induce a spatially uniform drive over the outside of a solid, spherical sample and a laser-heated thermal plasma as an x-ray source for radiography. Absolute shock Hugoniot measurements were demonstrated for carbon-containing samples of different composition and initial density, up to temperatures at which K-shell ionization reduced the opacity behind the shock. Here we present the experimental method using measurements of polystyrene as an example.

47 OTHER INSTRUMENTATION↗

Directional Software Algorithms and Sensor Evaluations

This report evaluates the relative performance of two directional gamma-ray spectrometers and processing algorithms that are used to construct images and spatially resolved spectra. Polaris, which was developed by H3D Inc., uses 18 pixelated CZT crystals to construct gamma-ray images in either Compton camera(CC) or coded aperture (CA) mode. The other sensor that is referenced in this report incorporates a commercial high-purity germanium based imager, called GeGI, with a coded aperture mask and processing software developed by Oak Ridge National Laboratory (ORNL). H3D and the University of Michigan provided several algorithms that can be used to process data collected by Polaris in CC mode. This evaluation compares the performance of these algorithms with a Directional Unfolded Source Term (DUST) approach developed by Sandia National Laboratories (SNL). DUST differs from the other algorithms because its primary objective is synthesis of spatially-resolved gamma ray spectra as opposed to image reconstruction.

97 MATHEMATICS AND COMPUTING↗

Evaluation of sliding baseline methods for spatial estimation for cluster detection in the biosurveillance system

Background: The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods: The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results: Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion: The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Resonances on the Noise Performance of SQUID Susceptometers

Scanning Superconducting Quantum Interference Device (SQUID) Susceptometry simultaneously images the local magnetic fields and susceptibilities above a sample with sub-micron spatial resolution. Further development of this technique requires a thorough understanding of the current, voltage, and flux ( I V Φ ) characteristics of scanning SQUID susceptometers. These sensors often have striking anomalies in their current–voltage characteristics, which we believe to be due to electromagnetic resonances. The effect of these resonances on the performance of these SQUIDs is unknown. To explore the origin and impact of the resonances, we develop a model that qualitatively reproduces the experimentally-determined I V Φ characteristics of our scanning SQUID susceptometers. We use this model to calculate the noise characteristics of SQUIDs of different designs. We find that the calculated ultimate flux noise is better in susceptometers with damping resistors that diminish the resonances than in susceptometers without damping resistors. Such calculations will enable the optimization of the signal-to-noise characteristics of scanning SQUID susceptometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Purely spatial coincidences of twin photons in parametric spontaneous down-conversion

We have measured sub-shot-noise quantum correlations of spatial fluctuations in the far-field image of the parametric fluorescence created in a type I {beta}-barium-borate nonlinear crystal, either between opposite angular sectors (nondegenerate configuration) or between opposite pixels (degenerate configuration). Imaging is performed at a very low light level (0.2 photons per pixel) with an electron-multiplying CCD camera, resulting in purely spatial coincidences between single photons when detecting on pixels. Experimental results overcome the standard quantum-limit-shot-noise level without subtraction of the variance of the detection noise. We compare these experimental results with numerical results given by the quantum Green's function method, which is proved to have strong advantages over stochastic simulations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measuring pH Changes Inside a Bipolar Membrane Junction

Here, the local pH environment within bipolar membrane (BPM) junctions is complex and not well understood, yet it is important to control for advancing the performance of BPM-based electrochemical systems. We report a voltammetric strategy using an ultrathin Ni mesh pH probe to spatially resolve pH changes in the BPM junction during model BPM electrolyzer operation. Under reverse bias, we observe depletion of OH – at the anion-exchange layer (AEL) interface, with a degree diminishing with increasing distance from the AEL. These gradients correlate with current-dependent water dissociation (WD) and are modulated by the electric field and the surface charge state of the catalyst. By correlating spatial pH profiles with the surface-charging behavior of WD catalysts, we explore a mechanism of catalyst-mediated H + and OH – transfer facilitated by hydrogen-bonding networks. These findings highlight the role of local chemistry and electrostatics in BPM performance and offer new methods to probe and engineer catalytic junctions in electrochemical energy devices.

Hou, Shujin [University of California, Berkeley, C↗

Assembly and Characterization of a Prototype Laser-Optical Firing System

The design, assembly and characterization of the latest generation of a small, ruggedized laser-optical firing system will be discussed. This work builds upon earlier results in an effort to continue the development of robust fiber-coupled laseroptical firing systems.[1][2] This newest prototype strives to improve on earlier designs, while continuing to utilize many of the environmentally proven opto-mechanical sub-assemblies.[2][3] One area of improvement involves the implementation of a second optical safing and arming component. Several additional design improvements were also incorporated to address shortcomings uncovered during environmental testing.[4][5] These tests and the subsequent failure analysis were performed at the laser sub-system level. Four identical prototypes were assembled and characterized. The performance of the units were evaluated by comparing a number of parameters including laser output energy, slope efficiency, beam divergence, spatial intensity profile, fiber injection and splitter-coupler transmission efficiency. Other factors evaluated were the ease of alignment, repeatability of the alignment process and the fabrication of the fiberoptical cables. The experimentally obtained results will be compared and contrasted to the performance of earlier prototypes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers

Purpose: The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images ofex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Methods: Five excised porcine bladders with a grid of 30–40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100–400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. Results: The authors found good structure accuracy without dependency on bladder volume difference for all but one algorithm, and with the best result for the structure-based algorithm. Spatial accuracy as assessed from marker errors was disappointing for all algorithms, especially for large volume differences, implying that the deformations described by the registration did not represent anatomically correct deformations. The structure-based algorithm performed the best in terms of marker error for the large volume difference (100–400 ml). In general, for the small volume difference (100–150 ml) the algorithms performed relatively similarly. The structure-based algorithm exhibited the best balance in performance between small and large volume differences, and among the intensity-based algorithms, the algorithm implemented in VelocityAI exhibited the best balance. Conclusions: Validation of multiple DIR algorithms on a novel physiological bladder phantom revealed that the structure accuracy was good for most algorithms, but that the spatial accuracy as assessed from markers was low for all algorithms, especially for large deformations. Hence, many of the available algorithms exhibit sufficient accuracy for contour propagation purposes, but possibly not for accurate dose accumulation.

60 APPLIED LIFE SCIENCES↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting CO 2 Plume Migration in Heterogeneous Formations Using Conditional Deep Convolutional Generative Adversarial Network

Numerical simulation of flow and transport in heterogeneous formations has long been studied, especially for uncertainty quantification and risk assessment. The high computational cost associated with running large-scale numerical simulations in a Monte Carlo sense has motivated the development of surrogate models, which aim to capture the important input-output relations of physics-based models but require only a fraction of the cost of full model runs. In this work, we formulate a conditional deep convolutional generative adversarial network (cDC-GAN) surrogate model to learn the dynamic functional mappings in multiphase models. The cDC-GAN belongs to a class of semisupervised learning methods that can be used to learn the data generation processes. Like the original GAN, a main strength of the cDC-GAN is that it includes a self-training scheme for improving the quality of generative modeling in a game theoretic framework, without requiring extensive statistical knowledge and assumptions on input data distributions. In particular, our cDC-GAN model is designed to learn cross-domain mappings between high-dimensional input (e.g., permeability) and output (e.g., phase saturations) pairs, with the ability to incorporate conditioning information (e.g., prediction time). As a use case, we demonstrate the performance of cDC-GAN for predicting the migration of carbon dioxide (CO 2 ) plume in heterogeneous carbon storage reservoirs, which has both numerical and practical significance because of the safe storage requirements now mandated in many countries. Results show that cDC-GAN achieves high accuracy in predicting the spatial and temporal evolution patterns of the injected CO 2 plume, as compared to the original results obtained using a compositional reservoir simulator. The performance of cDC-GAN models, trained using the same number of training samples, stays relatively robust when the level of spatial heterogeneity is increased. Our cDC-GAN is pattern based and is not limited by the underlying physics. Thus, it provides a general framework for developing surrogate models, and for conducting uncertainty analyses for a wide range of physics-based models used in both groundwater and subsurface energy exploration applications.

54 ENVIRONMENTAL SCIENCES↗

Impact of the strength and spatial distribution of adsorption sites on methane deliverable capacity in nanoporous materials

The methane deliverable capacity of adsorbent materials is a critical performance metric that will determine the viability of using adsorbed natural gas (ANG) technology in vehicular applications. ARPA-E recently set a target deliverable capacity of 315 cc(STP)/cc that a viable adsorbent material should achieve to yield a driving range competitive with incumbent fuels. However, recent computational screening of hundreds of thousands of materials suggests that the target is unattainable. In this work, we aim to determine whether the observed limits in deliverable capacity (similar to 200 cc(STP)/cc) are fundamental limits arising from thermodynamic or material design constraints. Our efforts focus on simulating methane adsorption isotherms in a large number of systems, resulting in a broad exploration of different combinations of spatial distributions and energetics of adsorption sites. All systems were classified into five adsorption scenarios with varying degrees of realism in the manner that adsorption sites are created and endowed with energetics. The scenarios range from methane adsorption on discrete idealized lattice sites to adsorption in metal-organic frameworks with coordinatively unsaturated sites (CUS) provided by metalated catechol groups. Our findings strongly suggest that the ARPA-E target is unattainable, although not due to thermodynamic constraints but due to material design constraints. On the other hand, we also find that the currently observed deliverable capacity limits may be moderately surpassed. For instance, incorporation of CUS in IRMOF-10 is predicted to yield a 217 cc(STP)/cc deliverable capacity. The modified material has a similar to 0.85 void fraction and a heat of adsorption of similar to 15 kJ/mol. This suggests that similar, moderate improvements over existing materials could be achieved as long as CUS incorporation still maintains a relatively large void fraction. Nonetheless, we conclude that more significant improvements in deliverable capacity will require changes in the currently proposed operation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging performance of a hybrid x-ray computed tomography-fluorescence molecular tomography system using priors

Purpose: The performance is studied of two newly introduced and previously suggested methods that incorporate priors into inversion schemes associated with data from a recently developed hybrid x-ray computed tomography and fluorescence molecular tomography system, the latter based on CCD camera photon detection. The unique data set studied attains accurately registered data of high spatially sampled photon fields propagating through tissue along 360 deg. projections. Methods: Approaches that incorporate structural prior information were included in the inverse problem by adding a penalty term to the minimization function utilized for image reconstructions. Results were compared as to their performance with simulated and experimental data from a lung inflammation animal model and against the inversions achieved when not using priors. Results: The importance of using priors over stand-alone inversions is also showcased with high spatial sampling simulated and experimental data. The approach of optimal performance in resolving fluorescent biodistribution in small animals is also discussed. Conclusions: Inclusion of prior information from x-ray CT data in the reconstruction of the fluorescence biodistribution leads to improved agreement between the reconstruction and validation images for both simulated and experimental data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporally and spatially resolved characterization of microwave induced argon plasmas: Experiment and modeling

Experiments and modeling of the plasma-microwave interaction have been performed in a coaxial microwave plasma source at a field frequency of 2.45 GHz generating argon plasmas at pressures of 20 and 40 millibars and a ratio of flow rate to pressure of 0.125 sccm/Pa. The incident microwave power between 100 W and 300 W is supplied in a regime of a pulse-width modulation with cycle duration of 110 ms and a power-on time of 23 ms. The experiments are based on heterodyne reflectometry and microwave interferometry at 45.75 GHz. They provide the temporal behaviour of the complex reflection coefficient, the microwave power in the plasma, as well as the electron density in the afterglow zone of the discharge. The self-consistent spatially two-dimensional and time-dependent modeling complements the analysis of the plasma-microwave interaction delivering the plasma and electromagnetic field parameters. The consolidating experimental observations and model predictions allow further characterizing the plasma source. The generated plasma has a core occupying the region close to the end of the inner electrode, where maximum electron densities above 10{sup 20} m{sup −3} and electron temperatures of about 1 eV are observed. Due to a longer outer electrode of the coaxial structure, the plasma region is extended and fills the volume comprised by the outer electrode. The electron density reaches values of the order of 10{sup 19} m{sup −3}. The heating of the gas occurs in its great part due to elastic collisions with the plasma electrons. However, the contribution of the convective heating is important especially in the extended plasma region, where the gas temperature reaches its maximum values up to approximately 1400 K. The temporally and spatially resolved modeling enables a thorough investigation of the plasma-microwave interaction which clearly shows that the power in-coupling occurs in the region of the highest electron density during the early stage of the discharge. In the steady state phase, however, the power in-coupling occurs close to the source walls where the electron density is significantly lower than on the discharge axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗