Search NASA⌕ Search

SEARCH · Search NASA

Results for “Activity detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Advanced plastic scintillators for fast neutron discrimination

The present work addresses the need for solid-state, fast neutron discriminating scintillators that possess higher light yields and faster decay kinetics than existing organic scintillators. These respective attributes are of critical importance for improving the gamma-rejection capabilities and increasing the neutron discrimination performance under high-rate conditions. Two key applications that will benefit from these improvements include large-volume passive detection scenarios as well as active interrogation search for special nuclear materials. Molecular design principles were employed throughout this work, resulting in synthetically tailored materials that possess the targeted scintillation properties.

36 MATERIALS SCIENCE↗

Responder Technology Alert Monthly (Oct-Nov 2014)

As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in the areas wearable technology. The content is organized by technology function including: Sensors – Devices that detect physiological, particle, and chemical activity; Displays – Heads-up and body-worn visual displays; Power – Wearable power systems including chargers, batteries, self-powering or harvesting technologies, and power supplies; Integrated Communications – Voice and data communications systems utilizing Bluetooth, wireless, hands-free, ergonomically optimized systems, noise-filtering digital speakers or microphones, etc.; Exoskeletons – Whole or partial body suit that enhances mobility and physical performance; Wearable Computers – Body-worn data processing devices; General – Miscellaneous technologies as well as emerging trends or recent advances in the field of wearables.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Development of Metallic Magnetic Calorimeters for Nuclear Safeguards Applications

Many nuclear safeguards applications could benefit from high-resolution gamma-ray spectroscopy achievable with metallic magnetic calorimeters. This dissertation covers the development of a system for these applications based on gamma-ray detectors developed at the University of Heidelberg. It demonstrates new calorimeters of this type, which achieved an energy resolution of 45.5 eV full-width at half-maximum at 59.54 keV, roughly ten times better than current state of the art high purity germanium detectors. This is the best energy resolution achieved with a gamma-ray metallic magnetic calorimeter at this energy to date. In addition to demonstrating a new benchmark in energy resolution, an experimental system for measuring samples with metallic magnetic calorimeters was constructed at Lawrence Livermore National Laboratory. This system achieved an energy resolution of 91.3 eV full-width at half-maximum at 59.54 keV under optimal conditions. Using this system it was possible to characterize the linearity of the response, the count-rate limitations, and the energy resolution as a function of temperature of the new calorimeter. With this characterization it was determined that it would be feasible to measure 242Pu in a mixed isotope plutonium sample. A measurement of a mixed isotope plutonium sample was performed over the course of 12 days with a single two-pixel metallic magnetic calorimeter. The relative concentration of 242Pu in comparison to other plutonium isotopes was determined by direct measurement to less than half a percent accuracy. This is comparable with the accuracy of the best-case scenario using traditional indirect methods. The ability to directly measure the relative concentration of 242Pu in a sample could enable more accurate accounting and detection of indications of undeclared activities in nuclear safeguards, a better constraint on source material in forensic samples containing plutonium, and improvements in verification in a future plutonium disposition treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

User Behavior Analytics

User Behaviour Analytics is the tracking, collecting and assessing of user data and activities. The goal is to detect misuse of user credentials by developing models for the normal behaviour of user credentials within a computer network and detect outliers with respect to their baseline.

99 GENERAL AND MISCELLANEOUS↗

Data Analytics for SAR

We assess the ability of variants of anomalous change detection (ACD) to identify human activity associated with large outdoor music festivals as they are seen from synthetic aperture radar (SAR) imagery collected by the Sentinel-1 satellite constellation. We found that, with appropriate feature vectors, ACD using random-forest machine learning was most effective at identifying changes associated with the human activity.

47 OTHER INSTRUMENTATION↗

Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2 F 2 and UO 2 (NO 3 ) 2 , U 3 O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2 F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Spent Fuel NDA Project: Data Authentication Considerations

The overall spent fuel nondestructive assay project seeks to develop improved measurement capability for the verification of spent nuclear fuel, especially before its disposal or movement to hard-to-access storage. Various systems are being considered, employing neutron and/or gamma radiation detection with either passive or active methods; their use scenarios are not yet well defined. In a practical deployment, the measurement system would likely need to operate in unattended mode. The output results may also need to be shared between multiple recipients with various interests. The data authentication task considers what issues are important in being able to trust the measurement results. By defining and analyzing a generic (3z(Bbaseline(3y (Bsystem scenario, we have identified five key factors needing specific attention: application use-case details, equipment tamper indication, supporting (ancillary) instruments, systems implementation, and instrument state-of-health reporting.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Introduction to the Consortium for Monitoring, Technology, and Verification (MTV) [Slides]

Our mission is to develop new technologies that detect and deter nuclear proliferation activities while training the next generation of nuclear professionals. The three technical thrust areas are: 1. Fundamentals of nuclear and particle physics, 2. Signals and source terms for nuclear nonproliferation, and 3. Nuclear explosion. There are opportunities for collaborations with university faculty, possible student and post-doc work, and posting job ads. Further, MTV hosts various workshops, symposiums.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Progress Report for the Pathfinder Project: A Laser-Based / Fiber Optic IAEA Seal That Implements Spectral Interferometry

This is the first progress report for the Laser / Fiber-Optic Based IAEA Seal. This seal implements spectral interferometry, which is crucial for its resilience to tampering. Indeed, based on our understanding of telecommunications-based fiber optic technology, it is essentially impossible to tamper with the fiber without detection either immediately (with an active system) or subsequently (with a passive system).

36 MATERIALS SCIENCE↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

Microbial Reduction of Chromate in the Presence of Nitrate by Three Nitrate Respiring Organisms

A major challenge for the bioremediation of toxic metals is the co-occurrence of nitrate, as it can inhibit metal transformation. Geobacter metallireducens, Desulfovibrio desulfuricans, and Sulfurospirillum barnesii are three soil bacteria that can reduce chromate [Cr(VI)] and nitrate, and may be beneficial for developing bioremediation strategies. All three organisms respire through dissimilatory nitrate reduction to ammonia (DNRA), employing different nitrate reductases but similar nitrite reductase (Nrf). G. metallireducens reduces nitrate to nitrite via the membrane bound nitrate reductase (Nar), while S. barnesii and D. desulfuricans strain 27774 have slightly different forms of periplasmic nitrate reductase (Nap). We investigated the effect of DNRA growth in the presence of Cr(VI) in these three organisms and the ability of each to reduce Cr(VI) to Cr(III), and found that each organisms responded differently. Growth of G. metallireducens on nitrate was completely inhibited by Cr(VI). Cultures of D. desulfuricans on nitrate media was initially delayed (48 h) in the presence of Cr(VI), but ultimately reached comparable cell yields to the non-treated control. This prolonged lag phase accompanied the transformation of Cr(VI) to Cr(III). Viable G. metallireducens cells could reduce Cr(VI), whereas Cr(VI) reduction by D. desulfuricans during growth, was mediated by a filterable and heat stable extracellular metabolite. S. barnesii growth on nitrate was not affected by Cr(VI), and Cr(VI) was reduced to Cr(III). However, Cr(VI) reduction activity in S. barnesii, was detected in both the cell free spent medium and cells, indicating both extracellular and cell associated mechanisms. Taken together, these results have demonstrated that Cr(VI) affects DNRA in the three organisms differently, and that each have a unique mechanism for Cr(VI) reduction.

59 BASIC BIOLOGICAL SCIENCES↗

Identification of z ≳ 2 Herschel 500 μm sources using color deconfusion

We present a new method to search for candidate z ≳ 2 Herschel 500 μm sources in the Great Observatories Origins Deep Survey-North field using a S{sub 500 μm}/S{sub 24 μm} “color deconfusion” technique. Potential high-z sources are selected against low-redshift ones from their large 500 to 24 μm flux density ratios. By effectively reducing the contribution from low-redshift populations to the observed 500 μm emission, we are able to identify counterparts to high-z 500 μm sources whose 24 μm fluxes are relatively faint. The recovery of known z ≳ 4 starbursts confirms the efficiency of this approach in selecting high-z Herschel sources. The resulting sample consists of 34 dusty star-forming galaxies at z ≳ 2. The inferred infrared luminosities are in the range 1.5 × 10{sup 12}–1.8 × 10{sup 13} L{sub ⊙}, corresponding to dust-obscured star formation rates (SFRs) of ∼260–3100 M{sub ⊙} yr{sup −1} for a Salpeter initial mass function. Comparison with previous SCUBA 850 μm-selected galaxy samples shows that our method is more efficient at selecting high-z dusty galaxies, with a median redshift of z=3.07±0.83 and with 10 of the sources at z ≳ 4. We find that at a fixed luminosity, the dust temperature is ∼5 K cooler than that expected from the T{sub d}−L{sub IR} relation at z ≲ 1, though different temperature selection effects should be taken into account. The radio-detected subsample (excluding three strong active galactic nucleus) follows the far-infrared (far-IR)/radio correlation at lower redshifts, and no evolution with redshift is observed out to z∼5, suggesting that the far-IR emission is star formation dominated. The contribution of the high-z Herschel 500 μm sources to the cosmic SFR density is comparable to that of (sub)millimeter galaxy populations at z∼2.5 and at least 40% of the extinction-corrected UV samples at z∼4. Further investigation into the nature of these high-z dusty galaxies will be crucial for our understanding of the star formation histories and the buildup of stellar mass at the earliest cosmic epochs.

79 ASTRONOMY AND ASTROPHYSICS↗

The 2015–2016 Outburst of the Classical EXor V1118 Ori

After a quiescence period of about 10 years, the classical EXor source V1118 Ori has undergone an accretion outburst in 2015 September. The maximum brightness (ΔV≳4 mag) was reached in 2015 December and was maintained for several months. Since 2016 September, the source is in a declining phase. Photometry and low/high-resolution spectroscopy were obtained with MODS and LUCI2 at the Large Binocular Telescope, with the facilities at the Asiago 1.22 and 1.82 m telescopes, and with GIANO at the Telescopio Nazionale Galileo. The spectra are dominated by emission lines of H i and neutral metallic species. From line and continuum analysis we derive the mass accretion rate and its evolution during the outburst. Considering that extinction may vary between 1.5 and 2.9 mag, we obtain M-dot {sub acc} = 0.3–2.0 10{sup −8} M {sub ⊙} yr{sup −1} in quiescence and M-dot {sub acc} = 0.2–1.9 10{sup −6} M {sub ⊙} yr{sup −1} at the outburst peak. The Balmer decrement shape has been interpreted by means of line excitation models, finding that from quiescence to outburst peak, the electron density has increased from ∼2 10{sup 9} cm{sup −3} to ∼4 10{sup 11} cm{sup −3}. The profiles of the metallic lines are symmetric and narrower than 100 km s{sup −1}, while H i and He i lines show prominent wings extending up to ±500 km s{sup −1}. The metallic lines likely originate at the base of the accretion columns, where neutrals are efficiently shielded against the ionizing photons, while faster ionized gas is closer to the star. Outflowing activity is testified by the detection of a variable P Cyg-like profile of the Hα and He i 1.08 μm lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Acoustic-emission signal-processing analog unit for locating flaws in large tanks

Technique monitors structural flaws in 105-in. diameter tanks. Tank surface is divided into many areas and each area is sectioned into 20 equilateral triangles that form icosahedron. Twelve transducers are equally positioned on tank surface at vertex of each triangle. Transducers monitor area for flaws by detecting any increase in acoustical activity.

Moskal, F. J.↗

Terrestrial kilometric radiation: 2: Emission from the magnetospheric cusp and dayside magnetosheath

Measurements of the location of sources of terrestrial kilometric radiation obtained with the lunar orbiting Radio Astronomy Explorer-2 satellite have revealed a class of emission associated with the cusp and dayside magnetosheath. At frequencies near 250 kHz this emission is observed at radial distances between 2 and 20 R sub E at magnetic latitudes of 75 deg to 80 deg and is most often detected during periods of auroral activity (AE or approximately = 250) and southward orientation of the interplanetary magnetic field vertical component. During very disturbed times, the emission at the lowest frequencies ( or approximately = 200 kHz) appears to come from the dayside magnetosheath at distances or approximately = 12 R sub E. Whenever the geomagnetic dipole is tilted significantly with respect to the ecliptic pole ( or approximately = 10 deg) the cusp emission is confined to the hemisphere containing the sub solar point. The measurements also suggest that the region of cusp emission is rather narrowly confined in longitude to within + or - a few hours of the noon meridian.

Alexander, J. K.↗

Terrestrial kilometric radiation. II - Emission from the magnetospheric cusp and dayside magnetosheath

Measurements of the location of sources of terrestrial kilometric radiation obtained with the lunar-orbiting Radio Astronomy Explorer 2 satellite have revealed a class of emission associated with the cusp and dayside magnetosheath. At frequencies near 250 kHz, this emission is observed at radial distances between 2 and 20 earth radii at magnetic latitudes of 75 to 80 deg and is most often detected during periods of auroral activity and southward orientation of the interplanetary magnetic-field vertical component. During very disturbed times, the emission at the lowest frequencies (below about 200 kHz) appears to come from the dayside magnetosheath at distances of at least 12 earth radii. Whenever the geomagnetic dipole is tilted significantly with respect to the ecliptic pole, the cusp emission is confined to the hemisphere containing the subsolar point. The measurements also suggest that the region of cusp emission is rather narrowly confined in longitude to within a few hours of the noon meridian.

Alexander, J. K.↗

Lonar crater glasses and high-magnesium australites - Trace element volatilization and meteoritic contamination

Radiochemical neutron activation analysis was used to detect six siderophile elements (Ni, Re, Os, Pd, Ir and Au) and three volatile elements (Zn, Se and Cd) in two basalts, a pumice and three impact glasses from Lonar crater, India, and in six high-magnesium australites. Significant depletions in Re and Se with respect to the parent basalts were found in the Lonar glasses. These depletions, apparently correlated with the degree of shock, are probably due to volatilization under the oxidizing conditions characteristic of earth. One of the australites is substantially enriched in siderophiles relative to the level of these elements in the other five tektites. The element patterns in the australites resemble those of the carbonaceous or cometary component of an Apollo 16 soil.

Morgan, J. W.↗

Quarantine and protocol

The purpose of the Orbiting Quarantine Facility is to provide maximum protection of the terrestrial biosphere by ensuring that the returned Martian samples are safe to bring to Earth. The protocol designed to detect the presence of biologically active agents in the Martian soil is described. The protocol determines one of two things about the sample: (1) that it is free from nonterrestrial life forms and can be sent to a terrestrial containment facility where extensive chemical, biochemical, geological, and physical investigations can be conducted; or (2) that it exhibits "biological effects" of the type that dictate second order testing. The quarantine protocol is designed to be conducted on a small portion of the returned sample, leaving the bulk of the sample undisturbed for study on Earth.

Source record↗