Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Evolution of anisotropy of a partonic system from relativistic heavy-ion collisions

The evolution of anisotropy in momentum and coordinate space of the parton system produced in relativistic heavy-ion collisions is discussed within the free-streaming approximation. The momentum distribution evolves from the prolate shape (elongated along the beam) to the oblate one (squeezed along the beam). At the same time, the eccentricity in coordinate space, which occurs at finite values of impact parameter, decreases. It is argued that the parton system reaches local thermodynamic equilibrium before the momentum distribution becomes oblate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ejected Particle Size Distributions from Shocked Metal Surfaces

Here, we present size distributions for particles ejected from features machined onto the surface of shocked Sn targets. The functional form of the size distributions is assumed to be log-normal, and the characteristic parameters of the distribution are extracted from the measured angular distribution of light scattered from a laser beam incident on the ejected particles. We also found strong evidence for a bimodal distribution of particle sizes with smaller particles evolved from features machined into the target surface and larger particles being produced at the edges of these features.

36 MATERIALS SCIENCE↗

Enhancing the tensile properties of EBM as-built thin parts: Effect of HIP and chemical etching

Highlights: • The EBM process leads to important cross section variations in thin parts. • Stress calculation must be based on the average section in order to be relevant. • As-built state has a detrimental effect on every mechanical property. • Mechanical properties of machined samples are met with chemical etching. • HIP has a beneficial effect on the ductility. - Abstract: As-built Ti-6Al-4 V thin parts were manufactured using Electron Beam Melting (EBM) and characterized by optical microscopy and laboratory X-ray tomography in order to observe their microstructure, pore distribution and surface aspect. Chemical etching and HIP post-treatments were applied to as-built samples and their effect on the material and static mechanical properties were studied. Tensile tests were performed on both as-built and post-treated samples and their results compared to the ones reported in the literature for machined EBM samples. Because of the significant variations of the cross section observed along the gauge length, the calculation of the tensile stresses is not straightforward. Three simple sections were measured from the tomography scans. The average section along the gauge length was considered as the most suitable. The tensile mechanical properties of the as-built samples were studied and a detrimental effect of the surface state on the yield strength, ultimate tensile strength and elongation to failure was observed. Smoothing of the surface irregularities induced by chemical etching provoked an increase of those mechanical properties whereas the change of the microstructure generated by the HIP treatment leads to a decrease of the material strength that goes along with an increase of the ductility. Down scaling factors were proposed in order to take into account the sample state, as-built or post-treated.

36 MATERIALS SCIENCE↗

Tomographic phase-space mapping of intense particle beams using solenoids

Tomography based on quadrupole scans has been successfully applied to reconstruct the phase space of intense charged particle beams. This letter develops a tomographic technique based on solenoid scans, which is advantageous for solenoidal systems and injectors. The technique is generalized to the diagnosis of beams that are not axisymmetric, and validated through simulation. Solenoidal tomography is applied experimentally to a system with a nonequilibrium initial distribution, demonstrating its detailed evolution in phase space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incorporation model of N into GaInNAs alloys grown by radio-frequency plasma-assisted molecular beam epitaxy

We present a Maxwell-Boltzmann electron energy distribution based model for the incorporation rate of nitrogen into GaInNAs grown by molecular beam epitaxy (MBE) using a radio frequency plasma source. Nitrogen concentration is predicted as a function of radio-frequency system primary resistance, N flow, and RF power, and group III growth rate. The semi-empirical model is shown to be repeatable with a maximum error of 6%. The model was validated for two different MBE systems by growing GaInNAs on GaAs(100) with variable nitrogen composition of 0%–6%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of 6D Phase Space

A ‘Phase Space’ is a mathematical representation of all possible physical states of matter of a physical volume or system. Particle beams at Fermilab exist in a six-dimensional phase space: three position dimensions, and three momentum dimensions. To ‘reconstruct’ that space means to take measurement data from virtual detectors along those beams and map out where particles are and how they’re moving, using computational methods. In this experiment, we simulated a particle beam (Fig 1) and used the position distribution of each particle at each detector to map out the magnitude of the beam’s initial momentum.

Shirlee, Jermaine [DuPage Coll.]↗

Shear Lag in a Plywood Sheet-stringer Combination Used for the Chord Member of a Box Beam

Theoretical and experimental investigations were made of the distribution of strains in a plywood sheet-stringer combination used as the chord member of a box beam acted upon by bending loads. The theoretical solution was obtained with the help of the principle of minimum potential energy and certain simplifying assumptions. Strain measurements were made on a build-up box beam by means of electrical-resistance strain gages connected with strain indicators. A very satisfactory agreement between the theoretical and experimental strains was obtained.

LOADS - BEAMS, BOX↗

Beam-water Interaction System for PFAS Treatment

Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants that resist conventional water treatment due to the strength of their carbon fluorine bonds. Electron-beam irradiation has shown potential for PFAS degradation; however, its effectiveness is limited by shallow energy penetration, restricting treatment to the upper region of the water surface. This project addresses this limitation through the design of a compact mixing chamber and recirculation system to enhance surface renewal and improve treatment efficiency. The system, constrained to approximately 10 cm 20 cm 20 cm, was developed using computer-aided design, computational fluid dynamics (CFD), and MATLAB-based hydraulic analysis to evaluate flow behavior, head loss, and pump compatibility. A perforated-baffle geometry and controlled flow range of 1 3 GPM were implemented to promote uniform mixing while maintaining a stable free surface for electron-beam exposure. Modeling results indicate improved flow distribution and reduced dead zones, supporting more consistent interaction between contaminated water and the beam. The final design enhances hydrodynamic performance within system constraints, contributing to scalable electron-beam water treatment technologies for improved PFAS degradation.

Ramos, Gerardo [Northern Illinois U.]↗

Feasibility of a 90° electric sector energy analyzer for low energy ion beam characterization

A simple formula to calculate refocusing by locating the output slit at a specific distance away from the exit of 90° ion deflecting electric sector is given. Numerical analysis is also performed to calculate the ion beam trajectories for different values of the initial angular deviation of the beam. To validate the theory, a compact (90 mm × 5.5 mm × 32 mm) 90° sector ESA is fabricated which can fit through the inner diameter of a conflat 70 vacuum flange. Experimental results show that the dependence of resolution upon the distance between the sector exit and the Faraday cup agrees with the theory. The fabricated 90° sector electrostatic energy analyzer was then used to measure the space resolved ion energy distribution functions of an ion beam with the energy as low as 600 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast imaging of transient electronic plasmas produced in conditions of femtosecond waveguide writing in dielectrics

Femtosecond laser-induced plasmas in bulk dielectrics are imaged under waveguide writing conditions, for different polarizations, pulse durations, and processing depths, and their temporal evolution is measured using ultrafast pump-probe microscopy. The irradiation beam profile is elliptically shaped yielding a disklike focal volume. We demonstrate for doped phosphate glass that increasing the pulse duration improves the spatial distribution of deposited energy by minimizing beam filamentation and prefocal depletion effects. As a consequence, energy deposition in the desired volume is greatly enhanced. Our results identify key parameters for optimizing femtosecond laser processing of dielectrics and different strategies to minimize energy loss channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation pressure acceleration of corrugated thin foils by Gaussian and super-Gaussian beams

Rayleigh-Taylor instability of radiation pressure accelerated ultrathin foils by laser having Gaussian and super-Gaussian intensity distribution is investigated using a single fluid code. The foil is allowed to have ring shaped surface ripples. The radiation pressure force on such a foil is non-uniform with finite transverse component F{sub r}; F{sub r} varies periodically with r. Subsequently, the ripple grows as the foil moves ahead along z. With a Gaussian beam, the foil acquires an overall curvature due to non-uniformity in radiation pressure and gets thinner. In the process, the ripple perturbation is considerably washed off. With super-Gaussian beam, the ripple is found to be more strongly washed out. In order to avoid transmission of the laser through the thinning foil, a criterion on the foil thickness is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron maser emission mode coupling to the z-mode on a longitudinal density gradient in the context of solar type III bursts

A beam of super-thermal, hot electrons was injected into maxwellian plasma with a density gradient along a magnetic field line. 1.5D particle-in-cell simulations were carried out which established that the EM emission is produced by the perpendicular component of the beam injection momentum. The beam has a positive slope in the distribution function in perpendicular momentum phase space, which is the characteristic feature of a cyclotron maser. The cyclotron maser in the overdense plasma generates emission at the electron cyclotron frequency. The frequencies of generated waves were too low to propagate away from the injection region, hence the wavelet transform shows a pulsating wave generation and decay process. The intensity pulsation frequency is twice the relativistic cyclotron frequency. Eventually, a stable wave packet formed and could mode couple on the density gradient to reach frequencies of the order of the plasma frequency that allowed for propagation. The emitted wave is likely to be a z-mode wave. The total electromagnetic energy generated is of the order of 0.1% of the initial beam kinetic energy. The proposed mechanism is of relevance to solar type III radio bursts, as well as other situations, when the injected electron beam has a non-zero perpendicular momentum, e.g., magnetron.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aperture modulated, translating bed total body irradiation

Purpose: Total body irradiation (TBI) techniques aim to deliver a uniform radiation dose to a patient with an irregular body contour and a heterogeneous density distribution to within {+-}10% of the prescribed dose. In the current article, the authors present a novel, aperture modulated, translating bed TBI (AMTBI) technique that produces a high degree of dose uniformity throughout the entire patient. Methods: The radiation beam is dynamically shaped in two dimensions using a multileaf collimator (MLC). The irregular surface compensation algorithm in the Eclipse treatment planning system is used for fluence optimization, which is performed based on penetration depth and internal inhomogeneities. Two optimal fluence maps (AP and PA) are generated and beam apertures are created to deliver these optimal fluences. During treatment, the patient/phantom is translated on a motorized bed close to the floor (source to bed distance: 204.5 cm) under a stationary radiation beam with 0 deg. gantry angle. The bed motion and dynamic beam apertures are synchronized. Results: The AMTBI technique produces a more homogeneous dose distribution than fixed open beam translating bed TBI. In phantom studies, the dose deviation along the midline is reduced from 10% to less than 5% of the prescribed dose in the longitudinal direction. Dose to the lung is reduced by more than 15% compared to the unshielded fixed open beam technique. At the lateral body edges, the dose received from the open beam technique was 20% higher than that prescribed at umbilicus midplane. With AMTBI the dose deviation in this same region is reduced to less than 3% of the prescribed dose. Validation of the technique was performed using thermoluminescent dosimeters in a Rando phantom. Agreement between calculation and measurement was better than 3% in all cases. Conclusions: A novel, translating bed, aperture modulated TBI technique that employs dynamically shaped MLC defined beams is shown to improve dose uniformity in three dimensions. In comparison with the fixed open beam TBI technique, homogeneity of dose distribution is greatly improved.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structure Evolution and Distributions of Grain-Boundary Misorientainons in Submicrocrystalline Molybdenum Irradiated with a Pulsed Electron Beam

Using the methods of electron backscatter diffraction, electron microscopy and X-ray diffraction analysis, it is demonstrated that irradiation of the surface of a submicrocrystalline molybdenum specimen with a pulsed electron beam in a non-melt regime results in the formation of a gradient structure in its bulk. The irradiation temperature is shown to affect the density of defects, the value of stress, and the distributions of grain-boundary misorientations in the surface and bulk of the submicrocrystalline molybdenum specimens.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High angle annular dark field and electron energy loss spectroscopy study on the substitution and distribution of cobalt in ZnO by multilayer growth

Co-doped ZnO films were synthesized by ion beam sputtering using multilayer (ZnO/Co) growth. Both the distribution and the chemical states of Co in ZnO can be well controlled by varying the ratio of the nominal layer thickness of ZnO to Co. Transmission electron microscopy indicated that all of the as-deposited Zn{sub 1-x}(Co){sub x}O films were polycrystalline with a (0002) preferred orientation. The local microstructures and chemical states were identified by Z-contrast imaging and electron energy loss spectroscopy. In ZnO (1.5 nm)/Co (0.1 nm), homogeneous Co-doped ZnO was observed to have been formed through interdiffusion. However, decreasing or increasing the thickness of ZnO leads to the formation of Co clusters in the ZnO matrix or Zn{sub 1-x}(Co){sub x}O multilayers, respectively. For ZnO thickness{>=}1.5 nm, Co is substituted for Zn, and its valence state is 2{sup +}. All Co-doped ZnO films show room-temperature ferromagnetic behavior, which appears to depend strongly on the Co distribution.

36 MATERIALS SCIENCE↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

Analysis of H atoms in a negative ion source plasma with the non-equilibrium electron energy distribution function

In negative ion sources for the neutral beam injection, it is important to calculate H atom flux onto the plasma grid (PG) surface for the evaluation of H{sup -} production on the PG surface. We have developed a neutral (H{sub 2} molecules and H atoms) transport code. In the present study, the neutral transport code is applied to the analysis of the H{sub 2} and H transport in a NIFS-R and D ion source in order to calculate the flux onto the PG surface. Taking into account non-equilibrium feature of the electron energy distribution function (EEDF), i.e., the fast electron component, we have done the neutral transport simulation. The results suggest that the precise evaluation of the EEDF, especially in the energy range 15 eV < E < 30 eV is important for the dissociation rate of H{sub 2} molecules by the electron impact collision and the resultant H atom flux on the PG.

43 PARTICLE ACCELERATORS↗

Propagation of a laser beam in a time-varying waveguide

The propagation of an axisymmetric laser beam in a plasma column having a radially parabolic electron density distribution is reported. For the case of an axially uniform waveguide it is found that the basic characteristics of alternating focusing and defocusing beams are maintained. However, the intensity distribution is changed at the foci and outer-beam regions. The features of paraxial beam propagation are discussed with reference to axially varying waveguides. Laser plasma coupling is considered noting the case where laser heating produces a density distribution radially parabolic near the axis and the energy absorbed over the focal length of the plasma is small. It is found that: (1) beam-propagation stability is governed by the relative magnitude of the density fluctuations existing in the axial variation of the waveguides due to laser heating, and (2) for beam propagation in a time-varying waveguide, the global instability of the propagation is a function of the initial fluctuation growth rate as compared to the initial time rate of change in the radial curvature of the waveguide.

Chapman, J. M.↗